Displaying publications 61 - 80 of 1043 in total

Abstract:
Sort:
  1. Lee YK, Bister M, Salleh YM, Blanchfield P
    PMID: 19163841 DOI: 10.1109/IEMBS.2008.4650338
    Software technology enables computerized analysis to offer second opinion in various screening and diagnostic tasks to assist the clinicians. Yet, the performance of these computerized methods for medical images is questioned by experts in CAD research, owing to the use of different databases and criteria for evaluating the computer results for comparison. This paper intends to substantiate this statement by illustrating the effects of such issues with the use of 1D physiologic data and multiple databases. For this purpose, the detection of desaturation events in Sp02 and spike events in EEG are used. This is the first time that comparison between different algorithms on a common basis is carried out on an individual effort. The appraisal for all the algorithms is made on the same databases and criteria. It is surprising to find that issues for 2/3D images concur with those found in 1D data here. In evaluating the accuracy of a new algorithm, a single independent database gives results fast. This paper reveals weaknesses of such an approach. It is hoped that the supportive evidence shown here is enough for researchers to innovate a better platform for credibility in reporting performance comparison of computerized analysis algorithms.
    Matched MeSH terms: Sensitivity and Specificity
  2. Wong KI, Ho MM
    PMID: 19162703 DOI: 10.1109/IEMBS.2008.4649200
    Extended patient monitoring has become increasingly important for detection of cardiac conditions, such as irregularities in the rhythms of the heart, while patient is practicing normal daily activity. This paper presents a design of a single lead wireless cardiac rhythm interpretive instrument that capable of capture the electrocardiogram (ECG) in digital format and transmitted to a remote base-station (i.e. PC) for storage and further interpretation. The design has achieved high quality of ECG and free of interference in the presence of motion.
    Matched MeSH terms: Sensitivity and Specificity
  3. Ihtatho D, Fadzil MH, Affandi AM, Hussein SH
    PMID: 18002738
    Psoriasis is a skin disorder which is caused by genetic fault. There is no cure for psoriasis, however, there are many treatment modalities to help control the disease. To evaluate treatment efficacy, PASI (Psoriasis Area and Severity Index) which is the current gold standard method is used to measure psoriasis severity by evaluating the area, erythema, scaliness and thickness of the plaques. However, the calculation of PASI can be tedious and subjective. In this work, we develop a computer vision method that determines one of the PASI parameter, the lesion area. The method isolates healthy (or healed) skin areas from lesion areas by analyzing the hue and chroma information in the CIE L*a*b* colour space. Centroids of healthy skin and psoriasis in the hue-chroma space are determined from selected sample. Euclidean distance of all pixels from each centroid is calculated. Each pixel is assigned to the class with minimum Euclidean distance. The study involves patients from three different ethnic origins having different skin tones. Results obtained show that the proposed method is comparable to the dermatologist visual approach.
    Matched MeSH terms: Sensitivity and Specificity
  4. Nugroho H, Fadzil MH, Yap VV, Norashikin S, Suraiya HH
    PMID: 18002737
    In this paper, we describe an image processing scheme to analyze and determine areas of skin that have undergone repigmentation in particular, during the treatment of vitiligo. In vitiligo cases, areas of skin become pale or white due to the lack of skin pigment called melanin. Vitiligo treatment causes skin repigmentation resulting in a normal skin color. However, it is difficult to determine and quantify the amount of repigmentation visually during treatment because the repigmentation progress is slow and moreover changes in skin color can only be discerned over a longer time frame typically 6 months. Here, we develop a digital image analysis scheme that can identify and determine vitiligo skin areas and repigmentation progression on a shorter time period. The technique is based on principal component analysis and independent component analysis which converts the RGB skin image into a skin image that represent skin areas due to melanin and haemoglobin only, followed by segmentation process. Vitiligo skin lesions are identified as skin areas that lack melanin (non-melanin areas). In the initial studies of 4 patients, the method has been able to quantify repigmentation in vitiligo lesion. Hence it is now possible to determine repigmentation progression objectively and treatment efficacy on a shorter time cycle.
    Matched MeSH terms: Sensitivity and Specificity
  5. Zain JM, Fauzi AR
    PMID: 18003297
    This paper will study and evaluate watermarking technique by Zain and Fauzi [1]. Recommendations will then be made to enhance the technique especially in the aspect of recovery or reconstruction rate for medical images. A proposal will also be made for a better distribution of watermark to minimize the distortion of the Region of Interest (ROI). The final proposal will enhance AW-TDR in three aspects; firstly the image quality in the ROI will be improved as the maximum change is only 2 bits in every 4 pixels, or embedding rate of 0.5 bits/pixel. Secondly the recovery rate will also be better since the recovery bits are located outside the region of interest. The disadvantage in this is that, only manipulation done in the ROI will be detected. Thirdly the quality of the reconstructed image will be enhanced since the average of 2 x 2 pixels would be used to reconstruct the tampered image.
    Matched MeSH terms: Sensitivity and Specificity
  6. Hani AF, Prakasa E, Nugroho H, Affandi AM, Hussein SH
    PMID: 23366902 DOI: 10.1109/EMBC.2012.6346941
    Psoriasis is a common skin disorder with a prevalence of 0.6 - 4.8% around the world. The most common is plaques psoriasis and it appears as red scaling plaques. Psoriasis is incurable but treatable in a long term treatment. Although PASI (Psoriasis Area and Severity Index) scoring is recognised as gold standard for psoriasis assessment, this method is still influenced by inter and intra-rater variation. An imaging and analysis system called α-PASI is developed to perform PASI scoring objectively. Percentage of lesion area to the body surface area is one of PASI parameter. In this paper, enhanced imaging methods are developed to improve the determination of body surface area (BSA) and lesion area. BSA determination method has been validated on medical mannequin. BSA accuracies obtained at four body regions are 97.80% (lower limb), 92.41% (trunk), 87.72% (upper limb), and 83.82% (head). By applying fuzzy c-means clustering algorithm, the membership functions of lesions area for PASI area scoring have been determined. Performance of scoring result has been tested with double assessment by α-PASI area algorithm on body region images from 46 patients. Kappa coefficients for α-PASI system are greater than or equal to 0.72 for all body regions (Head - 0.76, Upper limb - 0.81, Trunk - 0.85, Lower limb - 0.72). The overall kappa coefficient for the α-PASI area is 0.80 that can be categorised as substantial agreement. This shows that the α-PASI area system has a high reliability and can be used in psoriasis area assessment.
    Matched MeSH terms: Sensitivity and Specificity
  7. Wai-Hoe L, Wing-Seng L, Ismail Z, Lay-Harn G
    Appl Biochem Biotechnol, 2009 Oct;159(1):221-32.
    PMID: 19145410 DOI: 10.1007/s12010-008-8503-x
    Renal calculi disease or known as kidney stone disease is the most common urological disorder in both men and women, although it is more prevalent in men. The lifetime chance for an individual to develop renal calculi is approximately 10% whereas the risk of recurrence in a 10-year period is 74%. Therefore, a diagnostic tool for screening or detecting renal calculi is greatly needed. In this study, we analyze urinary protein profiles from patients with renal calculi for the first time (RC), healthy subjects (HS), and patients with recurrent renal calculi (RRC) to identify a biomarker for detecting the disease. Urinary proteins were isolated by salt precipitation and the proteins resolved by SDS-PAGE. Target proteins were analyzed with LC/MS/MS. Thirty-two proteins were identified from healthy subjects and patients. Uromodulin was the most abundant urinary protein in HS but was a very faint band if detected at all from those that formed renal calculi for the first time (p < 0.05). Yet the excreted levels of urinary uromodulin in RRC were similar to those of the HS suggesting that uromodulin is a reliable biomarker for only RC. In addition, a few immunoglobulins that were commonly found in the urine of both RC and RRC, which include Ig alpha heavy chain 1, Ig gamma-2 c region, Ig gamma-3 heavy chain disease protein, Ig heavy chain variable region, Ig heavy constant region gamma 4, and Ig heavy chain. Ig heavy chain Fab frag and antibody a5b7 chain B may serve as potential biomarkers for renal calculi disease.
    Matched MeSH terms: Sensitivity and Specificity
  8. Lim KK, Yoon SY, Mohd Taib NA, Shabaruddin FH, Dahlui M, Woo YL, et al.
    Appl Health Econ Health Policy, 2018 06;16(3):395-406.
    PMID: 29572724 DOI: 10.1007/s40258-018-0384-8
    OBJECTIVE: Previous studies showed that offering BRCA mutation testing to population subgroups at high risk of harbouring the mutation may be cost effective, yet no evidence is available for low- or middle-income countries (LMIC) and in Asia. We estimated the cost effectiveness of BRCA mutation testing in early-stage breast cancer patients with high pre-test probability of harbouring the mutation in Malaysia, an LMIC in Asia.

    METHODS: We developed a decision analytic model to estimate the lifetime costs and quality-adjusted life-years (QALYs) accrued through BRCA mutation testing or routine clinical surveillance (RCS) for a hypothetical cohort of 1000 early-stage breast cancer patients aged 40 years. In the model, patients would decide whether to accept testing and to undertake risk-reducing mastectomy, oophorectomy, tamoxifen, combinations or neither. We calculated the incremental cost-effectiveness ratio (ICER) from the health system perspective. A series of sensitivity analyses were performed.

    RESULTS: In the base case, testing generated 11.2 QALYs over the lifetime and cost US$4815 per patient whereas RCS generated 11.1 QALYs and cost US$4574 per patient. The ICER of US$2725/QALY was below the cost-effective thresholds. The ICER was sensitive to the discounting of cost, cost of BRCA mutation testing and utility of being risk-free, but the ICERs remained below the thresholds. Probabilistic sensitivity analysis showed that at a threshold of US$9500/QALY, 99.9% of simulations favoured BRCA mutation testing over RCS.

    CONCLUSIONS: Offering BRCA mutation testing to early-stage breast cancer patients identified using a locally-validated risk-assessment tool may be cost effective compared to RCS in Malaysia.

    Matched MeSH terms: Sensitivity and Specificity
  9. Yeong CH, Ng KH, Abdullah BJJ, Chung LY, Goh KL, Perkins AC
    Appl Radiat Isot, 2014 Dec;94:216-220.
    PMID: 25222875 DOI: 10.1016/j.apradiso.2014.08.009
    Radionuclide imaging using (111)In, (99m)Tc and (153)Sm is commonly undertaken for the clinical investigation of gastric emptying, intestinal motility and whole gut transit. However the documented evidence concerning internal radiation dosimetry for such studies is not readily available. This communication documents the internal radiation dosimetry for whole gastrointestinal transit studies using (111)In, (99m)Tc and (153)Sm labeled formulations. The findings were compared to the diagnostic reference levels recommended by the United Kingdom Administration of Radioactive Substances Advisory Committee, for gastrointestinal transit studies.
    Matched MeSH terms: Sensitivity and Specificity
  10. Hashim S, Bradley DA, Saripan MI, Ramli AT, Wagiran H
    Appl Radiat Isot, 2010 Apr-May;68(4-5):700-3.
    PMID: 19892557 DOI: 10.1016/j.apradiso.2009.10.027
    This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being made to entirely enclose the fibres). The neutron irradiations were performed for exposure times of 1-, 2-, 3-, 5- and 7-days in a neutron tank filled with water. In this study, use was also made of the Monte Carlo N-particle (MCNP) code version 5 (V5) to simulate the neutron irradiations experiment. It was found that the commercially available Ge-doped and Al-doped optical fibres show a linear dose response subjected to fast neutrons from (241)AmBe source up to seven days of irradiations. The simulation performed using MCNP5 also exhibits a similar pattern, albeit differing in sensitivity. The TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre, the total absorption cross section for Ge in both the fast and thermal neutrons region being some ten times greater than that of Al.
    Matched MeSH terms: Sensitivity and Specificity
  11. Alanazi A, Alkhorayef M, Alzimami K, Jurewicz I, Abuhadi N, Dalton A, et al.
    Appl Radiat Isot, 2016 Nov;117:106-110.
    PMID: 26777569 DOI: 10.1016/j.apradiso.2016.01.001
    Graphite ion chambers and semiconductor diode detectors have been used to make measurements in phantoms but these active devices represent a clear disadvantage when considered for in vivo dosimetry. In such circumstance, dosimeters with atomic number similar to human tissue are needed. Carbon nanotubes have properties that potentially meet the demand, requiring low voltage in active devices and an atomic number similar to adipose tissue. In this study, single-wall carbon nanotubes (SWCNTs) buckypaper has been used to measure the beta particle dose deposited from a strontium-90 source, the medium displaying thermoluminescence at potentially useful sensitivity. As an example, the samples show a clear response for a dose of 2Gy. This finding suggests that carbon nanotubes can be used as a passive dosimeter specifically for the high levels of radiation exposures used in radiation therapy. Furthermore, the finding points towards further potential applications such as for space radiation measurements, not least because the medium satisfies a demand for light but strong materials of minimal capacitance.
    Matched MeSH terms: Sensitivity and Specificity
  12. Alawiah A, Bauk S, Marashdeh MW, Nazura MZ, Abdul-Rashid HA, Yusoff Z, et al.
    Appl Radiat Isot, 2015 Oct;104:197-202.
    PMID: 26188687 DOI: 10.1016/j.apradiso.2015.07.011
    In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF.
    Matched MeSH terms: Sensitivity and Specificity
  13. Amrani D, Tahtat M
    Appl Radiat Isot, 2001 Apr;54(4):687-9.
    PMID: 11225705
    Samples of natural and manufactured building materials collected from Algiers have been analysed for 226Ra, 232Th and 40K using a high-resolution HPGe gamma-spectrometry system. The specific concentrations for 226Ra, 232Th and 40K, from the selected building materials, ranged from (12-65 Bq kg(-1)), (7-51 B qkg(-1)) and (36-675 Bq kg(-1)), respectively. The measured activity concentrations for these natural radionuclides were compared with the reported data of other countries and with the world average activity of soil. Radium-equivalent activities were calculated for the measured samples to assess the radiation hazards arising from using those materials in the construction of dwellings. All building materials showed Ra(eq) activities lower than the limit set in the OECD report (370 Bq kg(-1)), equivalent to external gamma-dose of 1.5 mSv yr(-1).
    Matched MeSH terms: Sensitivity and Specificity
  14. Hamzan NI, Ab Rahman N, Suraiya S, Mohamad I, George Kalarakkal T, Mohamad S
    Arch Oral Biol, 2021 Apr;124:105051.
    PMID: 33581498 DOI: 10.1016/j.archoralbio.2021.105051
    OBJECTIVE: The present study established a real-time loop-mediated isothermal amplification (qLAMP) for rapid detection of human papillomavirus subtype 16 (HPV-16) in oral squamous cell carcinoma (OSCC).

    METHODS: The qLAMP assay was optimized targeting the HPV-16 E7 gene. The analytical sensitivity and specificity of the assay were determined using HPV-18 (ATCC® 45152D™), HPV-35 (ATCC® 40330™), HPV-43 (ATCC® 40338™) and HPV-56 (ATCC® 40549™) viral strains and oral bacteria. HPV-16 standard curve was constructed for determination of HPV-16 viral load. The diagnostic performance of the assay was evaluated from 63 OSCC patients comprising 63 tissue, 13 saliva and 49 blood samples, in comparison with p16 immunohistochemistry (IHC), in-house PCR and nested PCR assays.

    RESULTS: The detection limit of developed LAMP and PCR assays was 4.68 × 101 and 4.68 × 103 copies/μl, respectively. qLAMP assay enabled detection of positive results as early as 23 min at 67 °C. This assay can detect HPV-16 positivity in 23 % (3/13) saliva and 4.8 % (3/63) tissue samples with the viral load ranging from 4.68 × 101 to 4.68 × 104 copies/μl. HPV-16 positivity was not detected in all the blood samples. The sensitivity and specificity of qLAMP were 100 % in comparison with that of p16 IHC and nested PCR.

    CONCLUSION: This study reports for the first time on the use of qLAMP assay for detection of HPV-16 in OSCC in both tissue and saliva as the sample matrix which holds promise in improving the diagnostic application owing to its rapidity, simplicity, high sensitivity and specificity.

    Matched MeSH terms: Sensitivity and Specificity
  15. Subramaniam S, Chan CY, Soelaiman IN, Mohamed N, Muhammad N, Ahmad F, et al.
    Arch Osteoporos, 2019 11 28;14(1):117.
    PMID: 31781876 DOI: 10.1007/s11657-019-0666-2
    The concordance between osteoporosis self-assessment tool for Asians (OSTA) and dual-energy X-ray absorptiometry (DXA) was fair in the study. Modification of OSTA cutoff values improved its sensitivity to identify subjects at risk for suboptimal bone health (osteopenia/osteoporosis) and osteoporosis.

    PURPOSE: Osteoporosis self-assessment tool for Asians (OSTA) is a convenient screening algorithm used widely to identify patients at risk of osteoporosis. Currently, the number of studies validating OSTA in Malaysian population is limited. This study aimed to validate the performance of OSTA in identifying subjects with osteoporosis determined with DXA.

    METHODS: This cross-sectional study recruited 786 Malaysians in Klang Valley, Malaysia. Their bone health status was assessed by DXA and OSTA. The association and agreement between OSTA and bone mineral density assessment by DXA were determined by Pearson's correlation and Cohen's kappa, respectively. Receiver operating characteristics (ROC) curves were used to determine the sensitivity, specificity, and area under the curve (AUC) for OSTA.

    RESULTS: OSTA and DXA showed a fair association in the study (r = 0.382, κ = 0.159, p 

    Matched MeSH terms: Sensitivity and Specificity
  16. Rasool NB, Larralde G, Gorziglia MI
    Arch Virol, 1993;133(3-4):275-82.
    PMID: 8257289
    The VP4 genetic groups of 151 field strains of human rotaviruses obtained from infants and young children with diarrhea from four locations in Malaysia were analyzed. The strains were adapted to growth in tissue culture and studied further by molecular hybridization of northern blotted RNA to PCR-generated cDNA probes representing amino acids 84-180 of the KU strain VP4, 83-181 of the DS-1 strain VP4, and 83-180 of either the 1076 or K8 strain VP4, representing VP4 genetic groups 1-4 (P1A, P1B, P2, and P3), respectively. The majority (79% of the field strains hybridized with the KU VP4 genetic group 1 probe and were associated with G1, G3, G4, untypable, or mixed G serotypes. VP4 genetic group 1 (P1A) strains were the most common in all locations in Malaysia between 1978-1988. Three strains which exhibited G3 and subgroup I specificity hybridized with the K8 VP4 genetic group 4 probe. These three VP4 genetic group 4 (P3) strains were detected in two different years and locations, extending the initial detection of this VP4 genetic group (the K8 strain) in Japan to a larger geographical area of Asia.
    Matched MeSH terms: Sensitivity and Specificity
  17. Golder V, Kandane-Rathnayake R, Hoi AY, Huq M, Louthrenoo W, An Y, et al.
    Arthritis Res Ther, 2017 03 20;19(1):62.
    PMID: 28320433 DOI: 10.1186/s13075-017-1256-6
    BACKGROUND: Systemic lupus erythematosus (SLE) is associated with significant impairment of health-related quality of life (HR-QoL). Recently, meeting a definition of a lupus low disease activity state (LLDAS), analogous to low disease activity in rheumatoid arthritis, was preliminarily validated as associated with protection from damage accrual. The LLDAS definition has not been previously evaluated for association with patient-reported outcomes. The objective of this study was to determine whether LLDAS is associated with better HR-QoL, and examine predictors of HR-QoL, in a large multiethnic, multinational cohort of patients with SLE.
    METHODS: HR-QoL was measured using the Medical Outcomes Study 36-item short form health survey (SF-36v2) in a prospective study of 1422 patients. Disease status was measured using the SLE disease activity index (SLEDAI-2 K), physician global assessment (PGA) and LLDAS.
    RESULTS: Significant differences in SF-36 domain scores were found between patients stratified by ethnic group, education level and damage score, and with the presence of active musculoskeletal or cutaneous manifestations. In multiple linear regression analysis, Asian ethnicity (p 
    Matched MeSH terms: Sensitivity and Specificity
  18. Abdul Kadir A, Nordin R, Ismail SB, Yaacob MJ, Wan Mustapha WMR
    Asia Pac Fam Med, 2004;3(1&2):9-18.
    Aim. Validation of the Malay version of the Edinburgh Postnatal Depression Scale (EPDS)
    Methods. A validation study was done involving 52 mothers who were at 4-12 weeks post-delivery. The women completed the Malay versions of EPDS and the 30-item General Health Questionnaire (GHQ). They were then assessed with the Hamilton Depression Rating Scale (HDRS) and Clinical Interview Schedule (CIS). Psychiatric diagnoses were made based on ICD-10 criteria. The validity of EPDS was tested against this clinical diagnosis and the concurrent validity against the Malay version of 30-item GHQ and HDRS scores was also evaluated.
    Results. The best cut-off score of the Malay version of EPDS was 11.5 with the sensitivity of 72.7% and specificity of 92.6 %.
    Conclusion. The Malay version of EPDS is a valid and reliable screening tool for PND.
    Matched MeSH terms: Sensitivity and Specificity
  19. Othman S, Chia YC, Ng CJ
    Asia Pac Fam Med, 2003;2(4):206-212.
    Aim: To determine the accuracy of urinalysis in the detection of urinary tract infection (UTI) in symptomatic patients at primary care level. Methods: A cross sectional study was undertaken on 100 patients with symptoms of UTI presenting at the Primary Care Clinic of University Malaya Medical Center, Kuala Lumpur, Malaysia during the months of August to November 1999. Their urine samples were tested simultaneously using urine dipstick, urine microscopy and urine culture. Urine culture was used as the gold standard and UTI was diagnosed when the urine culture showed a bacteria count of >= 105 organisms per mL. The sensitivity and specificity of each test was calculated. Results: The prevalence of UTI was 25% in symptomatic patients. The urine dipstick for leukocyte esterase, nitrite and red blood cell had sensitivities of 76, 56 and 76%, respectively. Their specificities were 60, 81 and 61%, respectively. Urine microscopy for leukocytes, red blood cells and bacterial count had sensitivities of 80, 52 and 84%, while their specificities were 76, 80 and 54%, respectively. Conclusion: The prevalence of UTI in the present study was low despite reported symptoms of UTI. Urinalysis is needed to support the diagnosis of UTI. In the present study, while there is accuracy in the urinalysis (as the sensitivities and specificities of various tests are comparable with other studies); lack of precision in each test because of the wide range of 95% confidence interval make it less reliable. Caution should be made in interpreting each test.
    Matched MeSH terms: Sensitivity and Specificity
  20. Khatoon R, Khoo EM
    Asia Pac Fam Med, 2007;6(1).
    Aims: To determine whether the Edinburgh Claudication Questionnaire (ECQ) can be used as a screening tool for detecting peripheral arterial disease in patients with diabetes mellitus. 
    Methods: A cross-sectional study of 200 patients with diabetes over 18 years of age who attended a primary care clinic at a teaching hospital in Kuala Lumpur, Malaysia. Face-to-face interviews were conducted using the ECQ for the presence of intermittent claudication. Blood pressure and peripheral neuropathy were assessed. Ankle brachial pressure index (ABPI) was measured and used as a gold standard for the diagnosis of eripheral arterial disease (PAD), which was defined as an ABPI of < 0.9 on either leg. 
    Results: The overall prevalence of PAD was found to be 16% among patients with diabetes based on ABPI. Among these 32 patients with PAD, eight (25%) had symptoms of intermittent claudication based on the ECQ. The ECQ was found to have a low sensitivity (25%) but a high specificity (99.4%), with a positive predictive value of 88.9% and a negative predictive value of 88% for diagnosing PAD in patients with diabetes. 
    Conclusions: The ECQ is not a good screening tool for detection of PAD among patients with diabetes due to its low sensitivity. Key words: ankle brachial pressure, diabetes mellitus, Edinburgh Claudication Questionnaires, intermittent claudication, peripheral arterial disease.
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links