Displaying publications 61 - 80 of 279 in total

Abstract:
Sort:
  1. Khachatryan V, Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, et al.
    Phys Rev Lett, 2017 Jan 13;118(2):021802.
    PMID: 28128610 DOI: 10.1103/PhysRevLett.118.021802
    A first search for pair production of dark matter candidates through vector boson fusion in proton-proton collisions at sqrt[s]=8  TeV is performed with the CMS detector. The vector boson fusion topology enhances missing transverse momentum, providing a way to probe supersymmetry, even in the case of a compressed mass spectrum. The data sample corresponds to an integrated luminosity of 18.5  fb^{-1}, recorded by the CMS experiment. The observed dijet mass spectrum is consistent with the standard model expectation. In an effective field theory, dark matter masses are explored as a function of contact interaction strength. The most stringent limit on bottom squark production with mass below 315 GeV is also reported, assuming a 5 GeV mass difference with respect to the lightest neutralino.
    Matched MeSH terms: Motion
  2. Khachatryan V, Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, et al.
    Phys Rev Lett, 2016 Apr 29;116(17):172302.
    PMID: 27176516 DOI: 10.1103/PhysRevLett.116.172302
    Results on two-particle angular correlations for charged particles produced in pp collisions at a center-of-mass energy of 13 TeV are presented. The data were taken with the CMS detector at the LHC and correspond to an integrated luminosity of about 270  nb^{-1}. The correlations are studied over a broad range of pseudorapidity (|η|<2.4) and over the full azimuth (ϕ) as a function of charged particle multiplicity and transverse momentum (p_{T}). In high-multiplicity events, a long-range (|Δη|>2.0), near-side (Δϕ≈0) structure emerges in the two-particle Δη-Δϕ correlation functions. The magnitude of the correlation exhibits a pronounced maximum in the range 1.0
    Matched MeSH terms: Motion
  3. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Asilar E, Bergauer T, et al.
    Phys Rev Lett, 2018 Feb 23;120(8):081801.
    PMID: 29542998 DOI: 10.1103/PhysRevLett.120.081801
    The first observation of electroweak production of same-sign W boson pairs in proton-proton collisions is reported. The data sample corresponds to an integrated luminosity of 35.9    fb^{-1} collected at a center-of-mass energy of 13 TeV with the CMS detector at the LHC. Events are selected by requiring exactly two leptons (electrons or muons) of the same charge, moderate missing transverse momentum, and two jets with a large rapidity separation and a large dijet mass. The observed significance of the signal is 5.5 standard deviations, where a significance of 5.7 standard deviations is expected based on the standard model. The ratio of measured event yields to that expected from the standard model at leading order is 0.90±0.22. A cross section measurement in a fiducial region is reported. Bounds are given on the structure of quartic vector boson interactions in the framework of dimension-8 effective field theory operators and on the production of doubly charged Higgs bosons.
    Matched MeSH terms: Motion
  4. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Asilar E, Bergauer T, et al.
    Phys Rev Lett, 2018 Feb 16;120(7):071802.
    PMID: 29542941 DOI: 10.1103/PhysRevLett.120.071802
    An inclusive search for the standard model Higgs boson (H) produced with large transverse momentum (p_{T}) and decaying to a bottom quark-antiquark pair (bb[over ¯]) is performed using a data set of pp collisions at sqrt[s]=13  TeV collected with the CMS experiment at the LHC. The data sample corresponds to an integrated luminosity of 35.9  fb^{-1}. A highly Lorentz-boosted Higgs boson decaying to bb[over ¯] is reconstructed as a single, large radius jet, and it is identified using jet substructure and dedicated b tagging techniques. The method is validated with Z→bb[over ¯] decays. The Z→bb[over ¯] process is observed for the first time in the single-jet topology with a local significance of 5.1 standard deviations (5.8 expected). For a Higgs boson mass of 125 GeV, an excess of events above the expected background is observed (expected) with a local significance of 1.5 (0.7) standard deviations. The measured cross section times branching fraction for production via gluon fusion of H→bb[over ¯] with reconstructed p_{T}>450  GeV and in the pseudorapidity range -2.5
    Matched MeSH terms: Motion
  5. Alsabery AI, Tayebi T, Kadhim HT, Ghalambaz M, Hashim I, Chamkha AJ
    J Adv Res, 2021 May;30:63-74.
    PMID: 34026287 DOI: 10.1016/j.jare.2020.09.008
    Introduction: Mixed convection flow and heat transfer within various cavities including lid-driven walls has many engineering applications. Investigation of such a problem is important in enhancing the performance of the cooling of electric, electronic and nuclear devices and controlling the fluid flow and heat exchange of the solar thermal operations and thermal storage.

    Objectives: The main aim of this fundamental investigation is to examine the influence of a two-phase hybrid nanofluid approach on mixed convection characteristics including the consequences of varying Richardson number, number of oscillations, nanoparticle volume fraction, and dimensionless length and dimensionless position of the solid obstacle.

    Methods: The migration of composite hybrid nanoparticles due to the nano-scale forces of the Brownian motion and thermophoresis was taken into account. There is an inner block near the middle of the enclosure, which contributes toward the flow, heat, and mass transfer. The top lid cover wall of the enclosure is allowed to move which induces a mixed convection flow. The impact of the migration of hybrid nanoparticles with regard to heat transfer is also conveyed in the conservation of energy. The governing equations are molded into the non-dimensional pattern and then explained using the finite element technique. The effect of various non-dimensional parameters such as the volume fraction of nanoparticles, the wave number of walls, and the Richardson number on the heat transfer and the concentration distribution of nanoparticles are examined. Various case studies for Al2O3-Cu/water hybrid nanofluids are performed.

    Results: The results reveal that the temperature gradient could induce a notable concentration variation in the enclosure.

    Conclusion: The location of the solid block and undulation of surfaces are valuable in the control of the heat transfer and the concentration distribution of the composite nanoparticles.

    Matched MeSH terms: Motion
  6. Wan Hassan WN, Abu Kassim NL, Jhawar A, Shurkri NM, Kamarul Baharin NA, Chan CS
    Am J Orthod Dentofacial Orthop, 2016 Apr;149(4):567-78.
    PMID: 27021461 DOI: 10.1016/j.ajodo.2015.10.018
    In this article, we present an evaluation of user acceptance of our innovative hand-gesture-based touchless sterile system for interaction with and control of a set of 3-dimensional digitized orthodontic study models using the Kinect motion-capture sensor (Microsoft, Redmond, Wash).
    Matched MeSH terms: Motion
  7. Collin P, Hervé A, Walch G, Boileau P, Muniandy M, Chelli M
    J Shoulder Elbow Surg, 2019 Oct;28(10):2023-2030.
    PMID: 31405717 DOI: 10.1016/j.jse.2019.03.002
    BACKGROUND: Results of anatomic shoulder arthroplasty for glenohumeral osteoarthritis with severe glenoid retroversion are unpredictable with a high rate of glenoid loosening. Reverse shoulder arthroplasty (RSA) has been suggested as an alternative, with good early results. We sought to confirm this at longer follow-up (minimum 5 years). The study hypothesis was that early results would endure over time.

    METHODS: We retrospectively reviewed all RSAs performed in 7 centers from 1998 to 2010. The inclusion criteria were primary glenohumeral osteoarthritis with B1, B2, B3, or C glenoid. Forty-nine shoulders in 45 patients fulfilled the criteria. Bone grafting was performed in 16 cases. Clinical outcomes were evaluated with the Constant score (CS) and shoulder range of motion.

    RESULTS: The mean total CS increased from 30 preoperatively to 68 points (P < .001) with significant improvements in all the subsections of the CS and range of motion. Scapular notching was observed in 20 shoulders (43%), grade 1 in 5 (11%), grade 2 in 7 (15%), grade 3 in 5 (11%), and grade 4 in 3 (6%). The glenoid bone graft healed in all the shoulders. Partial inferior lysis of the bone graft was present in 8 cases (50%). Scapular notching and glenoid bone graft resorption had no influence on the CS (P = .147 and P = .798).

    CONCLUSION: RSA for the treatment of primary glenohumeral osteoarthritis in patients with posterior glenoid deficiency and humeral subluxation without rotator cuff insufficiency resulted in excellent clinical outcomes at a minimum of 5 years of follow-up.

    Matched MeSH terms: Range of Motion, Articular
  8. Yong CY, Sudirman R, Chew KM
    Sains Malaysiana, 2015;44(12):1661-1669.
    A scalable tracking human model was proposed for recognizing human jogging and walking activities. The model aims to detect and track a particular subject by using wearable sensor. Data collected are in accelerometer readings in three axes and gyroscope readings in three axes. The development of proposed human model is based on the moderating effects on human movements. Two moderators were proposed as the moderating factors of human motion and they are angular velocity and elevation angle. Linear regression is used to investigate the relationship among inputs, moderators and outputs of the model. The result of this study showed that the angular velocity and elevation angle moderators are affecting the relation of research output. Acceleration in x-axis (Ax) and angular velocity in y-axis (Gy) are the two main components in directing
    a motion. Classification between jogging and walking motions was done by measuring the magnitude of angular velocity and elevation angle. Jogging motion was classified and identified with larger angular velocity and elevation angle. The two proposed hypotheses were supported and proved by research output. The result is expected to be beneficial and able to assist researcher in investigating human motions.
    Matched MeSH terms: Motion
  9. Muhamad Effendi F, Nam Y, Shin CH, Cho TJ, Yoo WJ, Cheon JE, et al.
    J Pediatr Orthop B, 2018 Sep;27(5):407-411.
    PMID: 28704300 DOI: 10.1097/BPB.0000000000000477
    Heterotopic ossification in soft tissue or muscle is rare in the pediatric and adolescent age group. Most cases are associated with musculoskeletal injury and trauma to the central nervous system. Here, we describe an adolescent patient without a history of trauma or lesions in the central nervous system who presented with a painful limp with limited motion of the left hip. Investigations indicated unusually large heterotopic ossification extending from the inner aspect of the ilium down to the anterior part of the hip, highly likely to have developed after an unrecognized periacetabular pyomyositis primarily involving the iliacus muscle. Surgical excision was performed successfully without perioperative complications. No recurrence was detected at the final follow-up.
    Matched MeSH terms: Range of Motion, Articular
  10. Boo HC, Yeo SJ, Chong HC
    Malays Orthop J, 2020 Mar;14(1):55-60.
    PMID: 32296483 DOI: 10.5704/MOJ.2003.009
    Introduction: Stiffness after Total Knee Arthroplasty (TKA) is a complication that decreases patient satisfaction. Patients in an Asian population have potentially different requirements of knee range of motion. The authors have encountered patients who complain of subjective stiffness post TKA who do not have a severely restricting range of motion (ROM). Some patients have persistent subjective stiffness and undergone Manipulation Under Anaesthesia (MUA). We look at their functional outcomes post MUA.

    Materials and Methods: This is a retrospective study, including 48 patients from a single institution who underwent MUA for stiffness, separated into objective and subjective knee stiffness. Patients with subjective knee stiffness who underwent MUA had failed conservative management. ROM, Oxford Knee Scores (OKS), Knee Society Scores (KSS) and Short Form 36 (SF36) scores were compared at two years post MUA.

    Results: The demographics of the two patient groups were similar. The time interval between index TKA and MUA was higher in the subjective knee stiffness group. Pre-MUA OKS, KS Function Score, KSS and SF36 scores were similar in both patient subgroups. There was no significant difference in the OKS, KSS or SF36 at two year follow-up. The proportion of patients in each group who achieved the Minimum Clinically Important Difference (MCID) improvement in the scores was also similar.

    Conclusions: Patients with subjective knee stiffness can achieve similar functional outcome improvements in Oxford and Knee Society Scores with MUA at two years follow-up.

    Matched MeSH terms: Range of Motion, Articular
  11. Yap YT, Gouwanda D, Gopalai AA, Chong YZ
    Med Biol Eng Comput, 2021 Mar;59(3):711-720.
    PMID: 33625670 DOI: 10.1007/s11517-021-02337-7
    Asymmetrical stiff knee gait is a mechanical pathology that can disrupt lower extremity muscle coordination. A better understanding of this condition can help identify potential complications. This study proposes the use of dynamic musculoskeletal modelling simulation to investigate the effect of induced mechanical perturbation on the kneeand to examine the muscle behaviour without invasive technique. Thirty-eight healthy participants were recruited. Asymmetrical gait was simulated using knee brace. Knee joint angle, joint moment and knee flexor and extensor muscle forces were computed using OpenSim. Differences inmuscle force between normal and abnormal conditions were investigated using ANOVA and Tukey-Kramer multiple comparison test.The results revealed that braced knee experienced limited range of motion with smaller flexion moment occuring at late swing phase. Significant differences were found in all flexormuscle forces and in several extensor muscle forces (p<0.05). Normal knee produced larger flexor muscle force than braced knee. Braced knee generated the largest extensor muscle force at early swing phase. In summary, musculoskeletal modelling simulation can be a computational tool to map and detect the differences between normal and asymmetrical gaits.
    Matched MeSH terms: Range of Motion, Articular
  12. Then JW, Shivdas S, Tunku Ahmad Yahaya TS, Ab Razak NI, Choo PT
    J Hand Ther, 2020 05 16;33(2):235-242.
    PMID: 32430167 DOI: 10.1016/j.jht.2020.03.029
    STUDY DESIGN: This is a two-group randomized controlled trial.

    INTRODUCTION: Finger stiffness after treatment for metacarpal fractures often occurs due to poor compliance to the conventional rehabilitation programs. Gamification has shown success in improving adherence to and effectiveness of various therapies.

    PURPOSE OF THE STUDY: The purpose of this study was to evaluate whether gamification, using cost-effective devices was comparable with conventional physiotherapy in improving hand functions and adherence to rehabilitation in metacarpal fractures.

    METHODS: A 2-group randomized controlled trial involving 19 patients was conducted. Participants were randomized to a control (conventional physiotherapy, n = 10) or interventional group (gamification, n = 9). The grips strength and composite finger range of motion were measured at the baseline and each follow-up together with Patient-Rated Wrist and Hand Evaluation scores and compliance.

    RESULTS: There were no significant differences on improvements of grip strength (means difference 24.38 vs 20.44, P = .289) and composite finger range of motion (means difference 50.50 vs 51.11, P = .886). However, the gamification group showed better results in Patient-Rated Wrist and Hand Evaluation (mean 0.44 vs 8.45, P = .038) and compliance (P 

    Matched MeSH terms: Range of Motion, Articular
  13. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Range of Motion, Articular/physiology
  14. Arif M, Makundala V, Choon DSK
    Med J Malaysia, 2005 Jul;60 Suppl C:99-103.
    PMID: 16381292 MyJurnal
    We report on our early experiences with the Press Fit Condylar Rotating Platform (PFC-RP) total knee replacement prosthesis at University Malaya Medical Centre. This new prosthesis was introduced to Malaysia in 2001. It combines the rotating platform technology of Low Contact Stress (LCS) and the modularity of Press Fit Condylar (PFC) system. We performed 18 knee replacements using cruciate retaining prosthesis without patellar resurfacing in 10 patients and followed them up over a period of 16-month. A new operative strategy was developed to match the flexion and extension gaps. The pre- and post-operative assessments were made according to the American Knee Society Scores (AKSS). Post-operative pain relief, range of motion, knee score and functional score showed promising early results. The average knee rating improved from 28 to 91 (range 75-94). Average functional assessment improved from 26 to 82 (range 75-90). The radiographic assessments show correction of an average pre-operative varus of 140 to post-operative valgus of 50 (range 4-70). Early infection occurred in two knees. Both responded to aggressive debridement and antibiotics. Stiffness was encountered in one patient. There were no spinouts of the insert. We are satisfied that the implants are performing well at the one-year mark and will continue monitor this cohort.
    Matched MeSH terms: Range of Motion, Articular
  15. Tai, C.C., Abbas, A.A., Varaprasad, M., Choon, S.K.
    Malays Orthop J, 2007;1(1):22-25.
    MyJurnal
    We report on the medium term outcome of five patients (ten hips) who underwent one stage bilateral total hip arthroplasty. Both Harris Hip Scores and Oxford Hip Scores improved postoperatively as did range of motion. There was no radiographic evidence of loosening in any hip arthroplasty involved in this study, however one revision surgery was needed due to periprosthetic fracture. There were no increased medical complications. Based on our limited experience, we believe that one stage bilateral total hip arthroplasty is safe in selected patients.
    Matched MeSH terms: Range of Motion, Articular
  16. Khachatryan V, Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, et al.
    Eur Phys J C Part Fields, 2016;76(8):439.
    PMID: 28303081 DOI: 10.1140/epjc/s10052-016-4261-z
    A search for new physics is performed using events with two isolated same-sign leptons, two or more jets, and missing transverse momentum. The results are based on a sample of proton-proton collisions at a center-of-mass energy of 13[Formula: see text] recorded with the CMS detector at the LHC, corresponding to an integrated luminosity of 2.3 [Formula: see text]. Multiple search regions are defined by classifying events in terms of missing transverse momentum, the scalar sum of jet transverse momenta, the transverse mass associated with a [Formula: see text] boson candidate, the number of jets, the number of [Formula: see text] quark jets, and the transverse momenta of the leptons in the event. The analysis is sensitive to a wide variety of possible signals beyond the standard model. No excess above the standard model background expectation is observed. Constraints are set on various supersymmetric models, with gluinos and bottom squarks excluded for masses up to 1300 and 680[Formula: see text], respectively, at the 95 % confidence level. Upper limits on the cross sections for the production of two top quark-antiquark pairs (119[Formula: see text]) and two same-sign top quarks (1.7[Formula: see text]) are also obtained. Selection efficiencies and model independent limits are provided to allow further interpretations of the results.
    Matched MeSH terms: Motion
  17. Sheykhi-Dolagh R, Saeedi H, Farahmand B, Kamyab M, Kamali M, Gholizadeh H, et al.
    Prosthet Orthot Int, 2015 Jun;39(3):190-6.
    PMID: 24604086 DOI: 10.1177/0309364614521652
    BACKGROUND: Flexible flat foot is described as a reduction in the height of the medial longitudinal arch and may occur from abnormal foot pronation. A foot orthosis is thought to modify and control excessive pronation and improve arch height.
    OBJECTIVE: To compare the immediate effect of three types of orthoses on foot mobility and the arch height index in subjects with flexible flat feet.
    STUDY DESIGN: A quasi-experimental study.
    METHOD: The dorsal arch height, midfoot width, foot mobility and arch height index were assessed in 20 participants with flexible flat feet (mean age = 23.2 ± 3 years) for three different foot orthosis conditions: soft, semi-rigid and rigid University of California Biomechanics Laboratory (UCBL).
    RESULTS: Maximum midfoot width at 90% with arch mobility in the coronal plane was shown in the semi-rigid orthosis condition. The semi-rigid orthosis resulted in the highest mean foot mobility in 90% of weight bearing, and the rigid orthosis (UCBL) had the lowest mean foot mobility. The soft orthosis resulted in foot mobility between that of the rigid and the semi-rigid orthosis. UCBL orthosis showed the highest arch height index, and the semi-rigid orthosis showed the lowest mean arch height index.
    CONCLUSION: Due to its rigid structure and long medial-lateral walls, the UCBL orthosis appears to limit foot mobility. Therefore, it is necessary to make an orthosis that facilitates foot mobility in the normal range of the foot arch. Future studies should address the dynamic mobility of the foot with using various types of foot orthoses.
    CLINICAL RELEVANCE: Although there are many studies focussed on flat foot and the use of foot orthoses, the mechanism of action is still unclear. This study explored foot mobility and the influence of foot orthoses and showed that a more rigid foot orthosis should be selected based on foot mobility.
    KEYWORDS: Foot orthosis; arch height index; foot mobility magnitude
    Matched MeSH terms: Range of Motion, Articular/physiology*
  18. Shamsir MS, Dalby AR
    Biophys J, 2007 Mar 15;92(6):2080-9.
    PMID: 17172295
    Previous molecular dynamic simulations have reported elongation of the existing beta-sheet in prion proteins. Detailed examination has shown that these elongations do not extend beyond the proline residues flanking these beta-sheets. In addition, proline has also been suggested to possess a possible structural role in preserving protein interaction sites by preventing invasion of neighboring secondary structures. In this work, we have studied the possible structural role of the flanking proline residues by simulating mutant structures with alternate substitution of the proline residues with valine. Simulations showed a directional inhibition of elongation, with the elongation progressing in the direction of valine including evident inhibition of elongation by existing proline residues. This suggests that the flanking proline residues in prion proteins may have a containment role and would confine the beta-sheet within a specific length.
    Matched MeSH terms: Motion
  19. Shariat A, Lam ET, Kargarfard M, Tamrin SB, Danaee M
    Work, 2017;56(3):421-428.
    PMID: 28269804 DOI: 10.3233/WOR-172508
    BACKGROUND: Previous research support the claim that people who work in offices and sit for a long time are particularly prone to musculoskeletal disorders.

    OBJECTIVE: The main objective of this paper is to introduce an exercise training program designed to decrease muscle stiffness and pain that can be performed in the office setting.

    METHODS: Forty healthy office workers (age: 28±5.3 years old; body mass: 87.2±10.2 kg; height: 1.79±0.15 m) apart from suffering from any sub-clinical symptoms of muscle and joint stiffness, and who had at least two years of experience in office work were chosen and randomly assigned to either an experimental group (n = 20) or a control group (n = 20). The experimental group performed the exercise training program three times a week for 11 weeks. The Cornell Musculoskeletal Discomfort Questionnaire was used to measure the pain levels in the neck, shoulders, and lower back areas. The Borg CR-10 Scale was used to measure their perceived exertion when doing the exercises, and a goniometer was used to measure the changes in range of motion (ROM) of the neck, hips, knees, and shoulders.

    RESULTS: The overall results indicated that the exercise program could significantly (p 

    Matched MeSH terms: Range of Motion, Articular
  20. Dhar SA, Mir NA, Dar TA
    Malays Orthop J, 2020 Nov;14(3):161-165.
    PMID: 33403078 DOI: 10.5704/MOJ.2011.025
    Introduction: The purpose of the study was to assess the efficacy of the dorsal closing wedge osteotomy for the treatment of Freiburg's infraction.

    Material and Methods: Twenty patients with Freiburg's infraction were admitted at our hospital over a period of six years. Patients with a normal plantar contour of the metatarsal head were included. All patients underwent a dorsal closing wedge osteotomy of the metatarsal.

    Results: The mean Leeds Movement Performance Index (LMPI) score was 84 (range 70-86). The mean metatarsal shortening was 2mm. the passive flexion restriction was 16° and extension restriction was 10°. Also, a strong negative correlation was found between Smillie classification and American Orthopaedic Foot and Ankle Score (AOFAS) final score (r's = -0.85, P < .001).

    Conclusion: The dorsal closing wedge osteotomy is an efficient and reproducible method for the management of Freiburg's infraction.

    Matched MeSH terms: Range of Motion, Articular
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links