OBJECTIVE: The aim of the present study was to determine the effects of type of visual image and gender on subjective visual horizontal (SVH) perception among healthy adults.
MATERIALS AND METHODS: In this comparative study, 50 healthy young adults were enrolled. While in an upright body position, they were required to report their perception of horizontality for two types of visual images (solid line and arrow pattern) using a computerized SVH device.
RESULTS: The arrow pattern produced significantly bigger SVH angles than the solid line (p < .001). In contrast, no significant influence of gender was found on SVH results (p = .743), Based on the statistical outcomes, the preliminary normative data for SVH were established.
CONCLUSIONS AND SIGNIFICANCE: The arrow pattern (a more complex visual image) produced bigger SVH deviations than the simple solid line image. In contrast, the horizontality perception does not appear to be affected by gender. The preliminary normative SVH data gathered from the present study can be beneficial for clinical and future research applications.
METHODS: This observational study was conducted at the Emergency Department of Sulaymaniyah General Teaching Hospital and Shar Hospital from September 1st, 2014 to August 31st, 2015. Fifty patients who developed acute spontaneous hypertensive intracerebral hemorrhage (ICH) and 50 patients who developed acute non-traumatic subarachnoid hemorrhage (SAH) were included in the study. All patients underwent resting 12-lead ECG within half an hour of admission. The QTc interval was calculated and analyzed in those 100 patients.
RESULTS: Females (62%) outnumbered males (38%) with a female to male ratio of 1.6:1. Forty percent of the patients were between 60-69 years of age. Hypertension was seen in 82% of patients while left ventricular hypertrophy was documented in 40% of patients. The QTc was prolonged in 38 patients (17 patients in the ICH group and 21 patients in the SAH group). In both groups, males demonstrated QTc prolongation more than females. However, there were no statistically significant gender difference between both groups and within the same group. There was a statistically significant association between SAH and QTc prolongation (p-value<0.001); the ICH group did not demonstrate any significant relationship with QTc prolongation.
CONCLUSION: Prolongation in the QTc interval was "statistically" associated with acute SAH only. No gender difference was noted; whether this observation is clinically significant or not, it needs further analytic studies.
Method: Participants of this cross-sectional study included 99 full-term neonates (165 ears) with mean chronological age of 46.7 hrs (SD = 26.3 hrs). Of the 99 neonates, 58 were Malay, 28 were Indian, and 13 were Chinese. The neonates who passed high-frequency (1 kHz) tympanometry, acoustic stapedial reflex, and distortion product otoacoustic emission screening tests were assessed using a pressurized WBA test (wideband tympanometry). To reduce the number of measurement points, the WBA responses were averaged to 16 one-third octave frequency bands from 0.25 to 8 kHz. A mixed-model analysis of variance was applied to the data to investigate the effects of frequency, ear, gender, and ethnicity on WBA. The analysis of variance was also used to compare between WBA measured at TPP and 0 daPa. An interclass correlation coefficient test was applied at each of the 16 frequency bands to measure the test-retest reliability of WBA at TPP and 0 daPa.
Results: Both WBA measurements at TPP and 0 daPa exhibited a multipeaked pattern with 2 maxima at 1.25-1.6 kHz and 6.3 kHz and 2 minima at 0.5 and 4 kHz. The mean WBA measured at TPP was significantly higher than that measured at 0 daPa at 0.25, 0.4, 0.5, 1.25, and 1.6 kHz only. A normative data set was developed for absorbance at TPP and at 0 daPa. There was no significant effect of ethnicity, gender, and ear on both measurements of WBA. The test-retest reliability of WBA at TPP and 0 daPa was high with the interclass correlation coefficient ranging from 0.77 to 0.97 across the frequencies.
Conclusions: Normative data of WBA measured at TPP and 0 daPa for neonates were provided in the present study. Although WBA at TPP was slightly higher than the WBA measured at 0 daPa at some frequencies below 2 kHz, the WBA patterns of the 2 measurements were nearly identical. Moreover, the test-retest reliability of both WBA measurements was high.
METHODS: This study involved 307 adults aged 60 years and older. Participants had their hearing and cognition measured using pure tone audiometry and Mini Mental State Examination (MMSE), respectively.
RESULTS: Pure tone average (low) accounted for significant but minimal amount of variance in measure of MMSE. Multiple regression analyses were also performed on normal and impaired hearing cohorts and cohorts with younger (60-69 years) and older (≥70 years) groups. The results revealed a significant relationship between PTA (low) and MMSE only in the younger age group. In contrast, no significant relationship was found between PTA (high) and cognition in any of the cohorts.
CONCLUSION: Pure tone average (low) is significantly but minimally related to measure of general cognitive status. Similar relationship is not observed between high-frequency hearing and cognition. Further research using a more comprehensive cognitive test battery is needed to confirm the lack of association between high-frequency hearing and cognition.