Displaying publications 81 - 100 of 681 in total

Abstract:
Sort:
  1. Hwong CS, Leong KH, Aziz AA, Kong KW
    Chem Biodivers, 2023 Jul;20(7):e202300215.
    PMID: 37278124 DOI: 10.1002/cbdv.202300215
    This study aimed to fractionate Alternanthera sessilis Red (ASR) crude extracts and determine their antioxidant activities as well as the related active components in the whole plant. ASR was extracted with water and ethanol, and further separated using a Sephadex LH-20 column. Following the assessments of the polyphenolic contents and antioxidant activities of crude extracts (H2 OASR and EtOHASR ) and fractions, a HPLC-QToF analysis was performed on the crude extracts and selected fractions (H2 OASR FII and EtOHASR FII). Three water fractions (H2 OASR FI, FII and FIII) and four ethanolic fractions (EtOHASR FI, FII, FIII and FIV) were derived from their crude extracts, respectively. EtOHASR FII exhibited the greatest total phenolic content (120.41 mg GAE/g fraction), total flavonoid content (223.07 mg RE/g fraction), and antioxidant activities (DPPH IC50 =159.43 μg/mL; FRAP=1.93 mmol Fe2+ /g fraction; TEAC=0.90 mmol TE/g fraction). Correlation analysis showed significant (p<0.01) positive correlations between both TPC (r=0.748-0.970) and TFC (r=0.686-0.949) with antioxidant activities in the crude extracts and fractions. Flavonoids were the major compounds in the four selected samples tentatively identified using HPLC-QToF-MS/MS, with the highest number of 30 polyphenol compounds detected in the most active fraction, EtOHASR FII.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  2. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2012 May;24(5):356-67.
    PMID: 22517322 DOI: 10.1002/chir.22019
    Because chiral liquid chromatography (LC) could become a powerful tool to estimate racemic atenolol quantity, excellent enantiomeric separation should be produced during data acquisition for satisfactory observation of atenolol concentrations throughout the racemic resolution processes. Selection of chiral LC column and analytical protocol that fulfill demands of the ultra fast LC analysis is essential. This article describes the characteristics of atenolol chromatographic separation that resulted from different resolution media and analytical protocols with the use of a Chiralcel® OD column. The chromatograms showed quite different characteristics of the separation process. The single enantiomer and racemic atenolol could be recognized by the Chiralcel® OD column in less than 20 min. Symmetrical peaks were obtained; however, several protocols produced peaks with wide bases and slanted baselines. Observations showed that efficient enantioresolution of racemic atenolol was obtained at slow mobile phase flow rate, decreased concentration of amine-type modifier but increased alcohol content in mobile phase and highest ultraviolet detection wavelength were required. The optimal ultra fast LC protocol enables to reduce and eliminate the peaks of either the atenolol solvent or the buffers and provided the highest peak intensities of both atenolol enantiomers.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  3. Chin SF, Osman J, Jamal R
    Clin Chim Acta, 2018 Oct;485:60-66.
    PMID: 29935177 DOI: 10.1016/j.cca.2018.06.024
    A simple and economical method has been developed for simultaneous determination of human serum 25-hydroxyvitamin D2 (25OHD2) and 25-hydroxyvitamin D3 (25OHD3) using Ultra Performance Liquid Chromatography (UPLC). Non-human matrix of 4% BSA was used to construct the calibration curve and in quality control samples' preparation to avoid interference of the endogenous 25-hydroxyvitamin D (25OHD) present in the human serum. 25OHD2, 25OHD3 and dodecanophenone (internal standard, IS) were separated on a CORTECS solid-core particle column and monitored by photodiode array detector at wavelength of 265 nm within five min run time. The relationship between 25OHD concentration and peak area ratio (25OHD:IS) was linear over the range of 12.5 - 200 nM with mean correlation coefficients (r2) >0.998. The limit of detection (LOD) for 25OHD2 and 25OHD3 was 3.00 nM and 3.79 nM, while the lower limit of quantification (LLOQ) was 9.11 nM and 11.48 nM, respectively. High repeatability was obtained for both isomers with intra-day CV% <5.6% and <5.3% for inter-day assay. This method was further tested with a commercial lyophilized serum control with an accuracy of 92.87-108.31% and applied on 214 human serum samples. In summary, this validated method with BSA can be reliably applied for routine quantification of 25OHD in adults.
    Matched MeSH terms: Chromatography, High Pressure Liquid/economics
  4. Thevarajah M, Nadzimah MN, Chew YY
    Clin Biochem, 2009 Mar;42(4-5):430-4.
    PMID: 19026622 DOI: 10.1016/j.clinbiochem.2008.10.015
    Glycated hemoglobin, measured as HbA1c is used as an index of mean glycemia in diabetic patients over the preceding 2-3 months. Various assay methods are used to measure HbA1c and many factors may interfere with its measurement according to assay method used, causing falsely high or low results.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Liem LK, Choong LH, Woo KT
    Clin Biochem, 2002 May;35(3):181-7.
    PMID: 12074825
    OBJECTIVE: Dihydropyrimidine dehydrogenase (DPD) catalyzes the degradation of thymine, uracil, and the chemotherapeutic drug 5-Fluorouracil. In general reverse-phase high pressure liquid chromatography is the standard method for separating 5-[2-(14)C]Fluorouracil and 5-[2-(14)C]Fluoro-5,6-dihydrouracil. However, the use of 100% aqueous solution (as HPLC mobile phase) may collapse the C-18 bonded phase and result in a retention time shift. The aim of this study is to develop a rapid, reproducible, sensitive method for screening partial DPD deficiency in healthy volunteers.

    DESIGN AND METHODS: The activity of DPD was measured using 5-[2- (14)C]Fluorouracil (5-[2-(14)C]FUra) followed by separation of substrate and product 5-[2-(14)C]FUraH(2) with a 15 x 4.6 mm I.D., 5 microm particle size (d(p)) porous graphitic carbon (PGC) column (Hypercarb(R)) and HPLC with online detection of the radioactivity. This was standardized using the protein concentration of the cytosol (NanoOrange(R) Protein Quantitation).

    RESULTS: Complete baseline separation of 5-[2-(14)C]Fluorouracil (5-[2-(14)C]FUra) and 5-[2-(14)C]Fluoro-5,6-dihydrouracil (5-[2-(14)C]FUraH(2)) was achieved using a porous graphitic carbon (PGC) column. The detection limit for 5-[2-(14)C]FUraH(2) was 0.4 pmol.

    CONCLUSIONS: By using linear gradient separation (0.1% Trifluoroacetic acid [TFA] in water to 100% Methanol) protocols in concert with PGC columns (Hypercarb(R)), we have demonstrated that a PGC column has a distinct advantage over C-18 reverse phase columns in terms of column stability (pH 1-14). This method provides an improvement on the specific assay for DPD enzyme activity. It is rapid, reproducible and sensitive and can be used for routine screening for healthy and cancer patients for partial and profound DPD deficiency before treatment with 5- FUra.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Chik Z, Basu RC, Pendek R, Lee TC, Mohamed Z
    Clin Ther, 2010 Sep;32(10):1822-31.
    PMID: 21194606 DOI: 10.1016/j.clinthera.2010.09.006
    Rifampicin is a semisynthetic antibiotic derivative of rifamycin used worldwide for the treatment of various forms of tuberculosis.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  7. Kong WM, Chik Z, Mohamed Z, Alshawsh MA
    PMID: 29076424 DOI: 10.2174/1386207320666171026121820
    AIM AND OBJECTIVE: Mitragynine, a major active alkaloid of Mitragyna speciosa, acts as an agonist on µ-opioid receptors, producing effects similar to morphine and other opioids. It has been traditionally utilized to alleviate opiate withdrawal symptoms. Besides consideration about potency and selectivity, a good drug must possess a suitable pharmacokinetic profile, with suitable absorption, distribution, metabolism, excretion and toxicity (ADME-Tox) profile, in order to have a high chance of success in clinical trials.

    MATERIAL AND METHOD: The purity of mitragynine in a Mitragyna speciosa alkaloid extract (MSAE) was determined using Ultra-Fast Liquid Chromatography (UFLC). In vitro high throughput ADMETox studies such as aqueous solubility, plasma protein binding, metabolic stability, permeability and cytotoxicity tests were carried out to analyze the physicochemical properties of MSAE and mitragynine. The UFLC quantification revealed that the purity of mitragynine in the MSAE was 40.9%.

    RESULTS: MSAE and mitragynine are highly soluble in aqueous solution at pH 4.0 but less soluble at pH 7.4. A parallel artificial membrane permeability assay demonstrated that it is extensively absorbed through the semi-permeable membrane at pH 7.4 but very poorly at pH 4.0. Both are relatively highly bound to plasma proteins (> 85 % bound) and are metabolically stable to liver microsomes (> 84 % remained unchanged). In comparison to MSAE, mitragynine showed higher cytotoxicity against WRL 68, HepG2 and Clone 9 hepatocytes after 72 h treatment.

    CONCLUSION: The obtained ADME and cytotoxicity data demonstrated that both MSAE and mitragynine have poor bioavailability and have the potential to be significantly cytotoxic.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  8. Tan NH
    PMID: 19770070 DOI: 10.1016/j.cbpc.2009.09.002
    A thrombin-like enzyme, purpurase, was purified from the Cryptelytrops purpureomaculatus (mangrove pit viper) venom using high performance ion-exchange and gel filtration chromatography. The purified sample (termed purpurase) yielded a homogeneous band in SDS-polyacrylamide gel electrophoresis with a molecular weight of 35,000. The N-terminal sequence of purpurase was determined to be VVGGDECNINDHRSLVRIF and is homologous to many other venom thrombin-like enzymes. Purpurase exhibits both arginine ester hydrolase and amidase activities. Kinetic studies using tripeptide chromogenic anilide substrates showed that purpurase is not fastidious towards its substrate. The clotting times of fibrinogen by purpurase were concentration dependent, with optimum clotting activity at 3mg fibronogen/mL. The clotting activity by purpurase was in the following decreasing order: cat fibrinogen>human fibrinogen>dog fibrinogen>goat fibrinogen>rabbit fibrinogen. Reversed-phase HPLC analysis of the products of action of purpurase on bovine fibrinogen showed that only fibrinopeptide A was released. Indirect ELISA studies showed that anti-purpurase cross-reacted strongly with venoms of most crotalid venoms, indicating the snake venom thrombin-like enzymes generally possess similar epitopes. In the more specific double-sandwich ELISA, however, anti-purpurase cross-reacted only with venoms of certain species of the Trimeresurus complex, and the results support the recent proposed taxonomy changes concerning the Trimeresurus complex.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  9. Rahmani A, Jinap S, Soleimany F
    Compr Rev Food Sci Food Saf, 2009 Jul;8(3):202-251.
    PMID: 33467794 DOI: 10.1111/j.1541-4337.2009.00079.x
      Mycotoxin toxicity occurs at very low concentrations, therefore sensitive and reliable methods for their detection are required. Consequently, sampling and analysis of mycotoxins is of critical importance because failure to achieve a suitable verified analysis can lead to unacceptable consignments being accepted or satisfactory shipments unnecessarily rejected. The general mycotoxin analyses carried out in laboratories are still based on physicochemical methods, which are continually improved. Further research in mycotoxin analysis has been established in such techniques as screening methods with TLC, GC, HPLC, and LC-MS. In some areas of mycotoxin method development, immunoaffinity columns and multifunctional columns are good choices as cleanup methods. They are appropriate to displace conventional liquid-liquid partitioning or column chromatography cleanup. On the other hand, the need for rapid yes/no decisions for exported or imported products has led to a number of new screening methods, mainly, rapid and easy-to-use test kits based on immuno-analytical principles. In view of the fact that analytical methods for detecting mycotoxins have become more prevalent, sensitive, and specific, surveillance of foods for mycotoxin contamination has become more commonplace. Reliability of methods and well-defined performance characteristics are essential for method validation. This article covers some of the latest activities and progress in qualitative and quantitative mycotoxin analysis.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  10. Hui BY, Raoov M, Zain NNM, Mohamad S, Osman H
    Crit Rev Anal Chem, 2017 Sep 03;47(5):454-467.
    PMID: 28453309 DOI: 10.1080/10408347.2017.1320936
    The growth in driving force and popularity of cyclodextrin (CDs) and ionic liquids (ILs) as promising materials in the field of analytical chemistry has resulted in an exponentially increase of their exploitation and production in analytical chemistry field. CDs belong to the family of cyclic oligosaccharides composing of α-(1,4) linked glucopyranose subunits and possess a cage-like supramolecular structure. This structure enables chemical reactions to proceed between interacting ions, radical or molecules in the absence of covalent bonds. Conversely, ILs are an ionic fluids comprising of only cation and anion often with immeasurable vapor pressure making them as green or designer solvent. The cooperative effect between CD and IL due to their fascinating properties, have nowadays contributed their footprints for a better development in analytical chemistry nowadays. This comprehensive review serves to give an overview on some of the recent studies and provides an analytical trend for the application of CDs with the combination of ILs that possess beneficial and remarkable effects in analytical chemistry including their use in various sample preparation techniques such as solid phase extraction, magnetic solid phase extraction, cloud point extraction, microextraction, and separation techniques which includes gas chromatography, high-performance liquid chromatography, capillary electrophoresis as well as applications of electrochemical sensors as electrode modifiers with references to recent applications. This review will highlight the nature of interactions and synergic effects between CDs, ILs, and analytes. It is hoped that this review will stimulate further research in analytical chemistry.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  11. Mozar FS, Chowdhury EH
    Curr Drug Deliv, 2015;12(3):333-41.
    PMID: 25600981
    Substantial amount of research has been done in recent decades for the development of nanoparticle systems to selectively deliver drugs to cancer cells for concurrently enhancing and reducing anti-cancer and off-target effects, respectively. pH-sensitive carbonate apatite (CA) was originally developed for efficient and targeted delivery of DNA, siRNA and proteins to various cancer cell lines. Recently, the CA particles were employed to deliver anti-cancer drugs, cyclophosphamide, doxorubicin and methotrexate to cancer cells. Here, we report on the fabrication and characterization of gemcitabine- loaded CA particles, followed by the evaluation of their roles in enhancement of cytotoxicity in two human and one murine breast cancer cell lines. HPLC was performed to measure binding efficiency of the drug to the apatite particles whereas particle size and zeta potential were evaluated to characterize drug/apatite complex. Depending on the initial doses of the drug, its bind binding affinity towards the particles varied from 3.85% to 4.45%. The particle size was found to surprisingly decrease with an increase of the initial drug concentration. In vitro chemosensitivity assay revealed that apatite/drug nanoparticle complexes presented significantly higher cytotoxicity to breast cancer cells compared to free drugs, which could be correlated with the enhanced cellular uptake of the small size drug-loaded particles through endocytosis compared to the passive diffusion of the free drug.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  12. Zamram QAZM, Mohsin HF, Mohamad MM, Nor Hazalin NAM, Hamid KA
    Curr Drug Deliv, 2021 Apr 18.
    PMID: 33874872 DOI: 10.2174/1567201818666210419114809
    AIM: Formulating topical products for skin delivery has always been a challenge for pharmaceutical scientists to fulfil good formulation criteria. Despite the challenges, gel-based drug delivery offers some advantages such that it is non-invasive, painless, avoidance of the first-pass metabolism and has satisfactory patient compliance.

    OBJECTIVES: In this study, Chromolaena odorata gel and quercetin gel (bioactive flavonoid compound) were successfully formulated and compared with placebo and conventional wound aid gel. The chromatographic profilling was conducted to screen the presence of phytoconstituents. Subsequently, all formulated gels were subjected to physical characteristic and stability study.

    METHODS: Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) of C.odorata methanolic leaves extract shows a distinct compound separation at retention time 8.4min to 34.8 min at 254nm. All gels were characterised by evaluating their rheological properties including storage modulus, loss modulus and plastic viscosity. Besides, texture analysis was performed to measure the gels' firmness, consistency, cohesiveness, and viscosity index.

    RESULTS: From the observation, C. odorata gel demonstrated better spreadability as compared to the other gels, which acquired less work and favourable to be applied onto the skin. Moreover, C. odorata gel showed no changes in organoleptic properties and proven to be stable after 30 days of accelerated stability study at 40°C ± 2°C with relative humidity (RH) of 75%± 5%.

    CONCLUSION: C. odorata gel has shown to be stable, reflecting the combination of materials used in the formulation, which did not degrade throughout the study. This work suggests the potential of this gel as a vehicle to deliver the active ingredients of C. odorata to the skin, which can be further explored as a topical application in antimicrobial wound management or other skin diseases study.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  13. Jaafar MHM, Hamid KA
    Curr Drug Deliv, 2019;16(7):672-686.
    PMID: 31250754 DOI: 10.2174/1567201816666190620110748
    BACKGROUND: In this study, four nanoparticle formulations (F1 to F4) comprising varying ratios of alginate, Pluronic F-68 and calcium chloride with a constant amount of insulin and chitosan as a coating material were prepared using polyelectrolyte complexation and ionotropic gelation methods to protect insulin against enzymatic degradation.

    METHODS: This study describes the formulation design, optimisation, characterisation and evaluation of insulin concentration via oral delivery in rats. A reversed-phase high-performance liquid chromatography (HPLC) method was developed and validated to quantify insulin concentration in rat plasma. The proposed method produced a linear response over the concentration range of 0.39 to 50 µg/ml.

    RESULTS: In vitro release study showed that dissolution of insulin in simulated gastric juice of pH 1.2 was prevented by alginate core and chitosan coating but rapidly released in simulated intestinal fluid (pH 6.8). Additionally, Formulation 3 (F3) has a particle size of 340.40 ± 2.39 nm with narrow uniformity exhibiting encapsulation efficiency (EE) of 72.78 ± 1.25 % produced highest absorption profile of insulin with a bioavailability of 40.23 ±1.29% and reduced blood glucose after its oral administration in rats.

    CONCLUSION: In conclusion, insulin oral delivery system containing alginate and chitosan as a coating material has the ability to protect the insulin from enzymatic degradation thus enhance its absorption in the intestine. However, more work should be done for instance to involve human study to materialise this delivery system for human use.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  14. Corrie L, Gulati M, Kaur J, Awasthi A, Vishwas S, Ramanunny AK, et al.
    Curr Drug Res Rev, 2023;15(3):272-285.
    PMID: 36683365 DOI: 10.2174/2589977515666230120140543
    BACKGROUND: Curcumin (CRM) is known to possess various therapeutic properties, such as anti-inflammatory and antidiabetic properties, and is, therefore, considered to be an effective therapeutic.

    OBJECTIVE: A sensitive method for the estimation of CRM in plasma, as well as fecal matter-based solid self-nano emulsifying drug delivery system (S-SNEDDS), has been reported for the first time.

    METHODS: A bioanalytical method was optimized using Box-Behnken Design having 13 runs and 3 responses. The optimized method was developed using methanol and water (70:30 v/v) with a flow rate of 1 mL/min. Quercetin was used as an internal standard. A specificity test was also performed for the developed CRM solid self-nano emulsifying drug delivery system.

    RESULTS: The retention time of CRM was found to be 14.18 minutes. The developed method was validated and found to be linear in the range of 50-250 ng/mL with an R2 of 0.999. Accuracy studies indicated that CRM had a percentage recovery of less than 105% and more than 95%, respectively. Precision studies were carried out for inter, intraday, and inter-analyst precision, and the %RSD was found to be less than 2%. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 3.37 ng/mL and 10.23 ng/mL, respectively. Stability studies for shortterm, long term and freeze-thaw cycles showed a %RSD of less than 2%, indicating the stability of CRM in the plasma matrix. Moreover, the blank fecal microbiota extract slurry did not show any peak at the retention time of CRM in a CRM-loaded solid nanoemulsifying drug delivery system containing fecal microbiota extract indicating its specificity.

    CONCLUSION: Hence, the developed method can have clinical implications as it helps estimate CRM in blood samples and also provides a simple and sensitive method for the estimation of plant-based flavonoids along with fecal microbiota extract formulations.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  15. Daood U, Tsoi JKH, Neelakantan P, Matinlinna JP, Omar HAK, Al-Nabulsi M, et al.
    Dent Mater, 2018 08;34(8):1175-1187.
    PMID: 29779627 DOI: 10.1016/j.dental.2018.05.005
    OBJECTIVE: Collagen fibrils aid in anchoring resin composite restorations to the dentine substrate. The aim of the study was to investigate effect of non-enzymatic glycation on bond strength and durability of demineralized dentine specimens in a modified two-step etch-and-rinse dentine adhesive.

    METHODS: Dentine surfaces were etched with 37% phosphoric acid, bonded with respective in vitro ethanol and acetone adhesives modified with (m/m, 0, 1%, 2% and 3% ribose), restored with restorative composite-resin, and sectioned into resin-dentine slabs and beams to be stored for 24h or 12 months in artificial saliva. Bond-strength testing was performed with bond failure analysis. Pentosidine assay was performed on demineralized ribose modified dentine specimens with HPLC sensitive fluorescent detection. The structural variations of ribose-modified dentine were analysed using TEM and human dental pulpal cells were used for cell viability. Three-point bending test of ribose-modified dentine beams were performed and depth of penetration of adhesives evaluated with micro-Raman spectroscopy. The MMP-2 and cathepsin K activities in ribose-treated dentine powder were also quantified using ELISA. Bond strength data was expressed using two-way ANOVA followed by Tukey's test. Paired T tests were used to analyse the specimens for pentosidine crosslinks. The modulus of elasticity and dentinal MMP-2 and cathepsin K concentrations was separately analyzed using one-way ANOVA.

    RESULTS: The incorporation of RB in the experimental two-step etch-and-rinse adhesive at 1% improved the adhesive bond strength without adversely affecting the degree of polymerisation. The newly developed adhesive increases the resistance of dentine collagen to degradation by inhibiting endogenous matrix metalloproteinases and cysteine cathepsins. The application of RB to acid-etched dentine helps maintain the mechanical properties.

    SIGNIFICANCE: The incorporation of 1%RB can be considered as a potential candidate stabilizing resin dentine bond.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  16. Akowuah GA, Zhari I
    Pharmazie, 2008 Nov;63(11):788-90.
    PMID: 19069237
    A simple high-performance liquid chromatography (HPLC) method to determine the content of betulinic acid (BA) in rat plasma collected at different times (0-8 h) after oral administration of Orthosiphon stamineus leaf extract was developed. The features of the assay include protein precipitation using acetonitrile and isocratic elution using reverse phase C-18 column with ultraviolet (UV) detection. The recovery of BA from plasma varied from 98.4 to 102.5%. The R.S.D of intra- and inter-day precision from rat plasma ranged from 4.2 to 9.8%. The maximum concentration of BA in the plasma was 1.2 +/- 0.3 microg/ml at 1 h after oral administration of the extract.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  17. Abdul Murad NA, Othman Z, Khalid M, Abdul Razak Z, Hussain R, Nadesan S, et al.
    Dig Dis Sci, 2012 Nov;57(11):2863-72.
    PMID: 22669205 DOI: 10.1007/s10620-012-2240-2
    BACKGROUND: Colorectal cancer (CRC) is the third most common cancer worldwide with approximately 1 million cases diagnosed annually. In Malaysia, CRC is the second most common cancer in women and ranked first in men. The underlying cause of CRC remains unknown.

    AIMS: The aim of this study was to analyze the mutations in genes involved in CRC including MLH1, MSH2, KRAS, and APC genes.

    METHODS: A total of 76 patients were recruited. We used the polymerase chain reaction-denaturing high-performance liquid chromatography for the detection of mutations in the mismatch repair (MMR) and APC genes and the PCR single-strand conformation polymorphism for screening of the KRAS gene mutations.

    RESULTS: We identified 17 types of missense mutations in 38 out of 76 patients in our patients. Nine mutations were identified in the APC gene, five mutations were detected in the KRAS gene, and two mutations were identified in the MSH2 gene. Only one mutation was identified in MLH1. Out of these 17 mutations, eight mutations (47 %) were predicted to be pathogenic. Seven patients were identified with multiple mutations (3: MSH2 and KRAS, 1: KRAS and APC, 1: MLH1 and APC, 2: APC and APC).

    CONCLUSIONS: We have established the PCR-DHPLC and PCR-SSCP for screening of mutations in CRC patients. This study has given a snapshot of the spectrum of mutations in the four genes that were analyzed. Mutation screening in patients and their family members will help in the early detection of CRC and hence will reduce mortality due to CRC.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  18. Baskaran G, Salvamani S, Ahmad SA, Shaharuddin NA, Pattiram PD, Shukor MY
    Drug Des Devel Ther, 2015;9:509-17.
    PMID: 25609924 DOI: 10.2147/DDDT.S75056
    The enzyme 3-hydroxy-3-methyl-glutaryl-coenzyme A (HMG-CoA) reductase is the key enzyme of the mevalonate pathway that produces cholesterol. Inhibition of HMG-CoA reductase reduces cholesterol biosynthesis in the liver. Synthetic drugs, statins, are commonly used for the treatment of hypercholesterolemia. Due to the side effects of statins, natural HMG-CoA reductase inhibitors of plant origin are needed. In this study, 25 medicinal plant methanol extracts were screened for anti-HMG-CoA reductase activity. Basella alba leaf extract showed the highest inhibitory effect at about 74%. Thus, B. alba was examined in order to investigate its phytochemical components. Gas chromatography with tandem mass spectrometry and reversed phase high-performance liquid chromatography analysis revealed the presence of phenol 2,6-bis(1,1-dimethylethyl), 1-heptatriacotanol, oleic acid, eicosyl ester, naringin, apigenin, luteolin, ascorbic acid, and α-tocopherol, which have been reported to possess antihypercholesterolemic effects. Further investigation of in vivo models should be performed in order to confirm its potential as an alternative treatment for hypercholesterolemia and related cardiovascular diseases.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  19. Saifullah B, El Zowalaty ME, Arulselvan P, Fakurazi S, Webster TJ, Geilich BM, et al.
    Drug Des Devel Ther, 2014;8:1029-36.
    PMID: 25114509 DOI: 10.2147/DDDT.S63753
    The treatment of tuberculosis by chemotherapy is complicated due to multiple drug prescriptions, long treatment duration, and adverse side effects. We report here for the first time an in vitro therapeutic effect of nanocomposites based on para-aminosalicylic acid with zinc layered hydroxide (PAS-ZLH) and zinc-aluminum layered double hydroxides (PAS-Zn/Al LDH), against mycobacteria, Gram-positive bacteria, and Gram-negative bacteria. The nanocomposites demonstrated good antimycobacterial activity and were found to be effective in killing Gram-positive and Gram-negative bacteria. A biocompatibility study revealed good biocompatibility of the PAS-ZLH nanocomposites against normal human MRC-5 lung cells. The para-aminosalicylic acid loading was quantified with high-performance liquid chromatography analysis. In summary, the present preliminary in vitro studies are highly encouraging for further in vivo studies of PAS-ZLH and PAS-Zn/Al LDH nanocomposites to treat tuberculosis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  20. Yuen KH, Peh KK, Billa N, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Feb;24(2):193-6.
    PMID: 15605452
    The bioavailability of a generic preparation of acyclovir (Avorax) was compared with the innovator product, Zovirax. Twelve healthy volunteers participated in the study, conducted according to a randomized, two-way crossover design. The preparations were compared using the parameters area under the plasma concentration time curve (AUC(0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the Tmax or the logarithmic transformed AUC(0-infinity) and C(max) values of the two preparations. In addition, the 90% confidence interval for the ratio of the logarithmic transformed AUC(0-infinity) values of Avorax over those of Zovirax was found to lie between 0.85 and 1.06, while that of the logarithmic transformed Cmax values was between 0.95 and 1.25, being within the bioequivalence limit of 0.80-1.25. Moreover, the elimination rate constant (k(e)), elimination half-life (t(1/2)), and apparent volume of distribution (Vd) values obtained with the two preparations were comparable and not significantly different statistically.
    Matched MeSH terms: Chromatography, High Pressure Liquid
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links