Displaying publications 81 - 100 of 1043 in total

Abstract:
Sort:
  1. Ng TKW
    Med J Malaysia, 1984 Mar;39(1):28-34.
    PMID: 6439983
    Correlation analysis of mid-arm circumference (MAC), weight-for-age and weight-for-height obtained from 807 Malay preschool children aged 12-71 months show that MAC had a relatively low correlation with weight-for-age (r = 0.59, P <0.001) and weight-for-height (r = 0.63, P<0.001). MAC percentiles and sensitivity-specificity analysis indicate that when weight-for-age and weight-for-height were used separately to define 'true' malnutrition, MAC was not sensitive enough to detect Malaysian children with only mild to moderate protein-energy malnutrition (PEM). The value of MAC as a screening measure in malnutrition is only limited to identifying the more severe forms of PEM in young children and the present study indicates that a MAC of 13.0-13.7 cm may be used for identifying moderate to severe PEM and under 13.0 cm for severe PEM.
    Matched MeSH terms: Sensitivity and Specificity
  2. Ashley J, Shukor Y, Tothill IE
    Analyst, 2016 Nov 14;141(23):6463-6470.
    PMID: 27813538
    The development of molecularly imprinted polymer nanoparticles (MIP-NPs), which specifically bind biomolecules, is of great interest in the area of biosensors, sample purification, therapeutic agents and biotechnology. Polymerisation techniques such as precipitation polymerisation, solid phase synthesis and core shell surface imprinting have allowed for significant improvements to be made in developing MIP-NPs which specifically recognise proteins. However, the development of MIP-NPs for protein templates (targets) still require lengthy optimisation and characterisation using different ratios of monomers in order to control their size, binding affinity and specificity. In this work we successfully demonstrated that differential scanning fluorimetry (DSF) can be used to rapidly determine the optimum imprinting conditions and monomer composition required for MIP-NP design and polymerisation. This is based on the stability of the protein template and shift in apparent melting points (Tm) upon interaction with different functional acrylic monomers. The method allows for the characterisation of molecularly imprinted nanoparticles (MIP-NPs) due to the observed differences in melting point profiles between, protein-MIP-NPs complexes, pre-polymerisation mixtures and non-imprinted nanoparticles (NIP-NPs) without the need for prior purification. The technique is simple, rapid and can be carried out on most quantitative polymerase chain reaction (qPCR) thermal cyclers which have the required filters for SYPRO
    Matched MeSH terms: Sensitivity and Specificity
  3. Samad SA, Rahman HA
    Singapore Med J, 1999 Aug;40(8):513-8.
    PMID: 10572490
    The purpose of this study was to retrospectively detect Aspergillus antigens in sera obtained from immunocompromised host using an in-house modified double antibody sandwich ELISA.
    Matched MeSH terms: Sensitivity and Specificity
  4. Maheswaran M, Adnan WA, Ahmad R, Ab Rahman NH, Naing NN, Abdullah J
    PMID: 18613557
    Non-traumatic Altered States of Consciousness (ASC) are a non-specific consequence of various etiologies, and are normally monitored by Glasgow Coma Scale (GCS). The GCS gives varriable results among untrained emergency medicine personel in developing countries where English is not the first language. An In House Scoring System (IHSS) scale was made by the first author for the purpose of triaging so as to quickly asses patients when seen by medical personel. This IHSS scale was compared to the GCS to determine it's specificity and sensitivity in the accident and emergency department (ED) of Hospital University Sains Malaysia (HUSM). All patients with non-traumatic ASC were selected by purposive sampling according to pre-determined criteria. Patients were evaluated by the two systems, IHSS and GCS, by emergency physicians who were on call. Patient demographics, clinical features, investigations, treatment given and outcomes were collected and followed for a period of 14 days. A total of 221 patients with non-traumatic ASC were studied, 54.3% were males. The mean age of the patients was 56 years old. The mean overall GCS score on presentation to the ED was 10.3. The mean duration of ASC was 11.6 hours. One hundred thirty patients (58.8%) experienced ASC secondary to general or focal cerebral disorders. The mortality rate was 40.3% 2 weeks after the ED visit. Fifty-four point three percent of the patients were awake and considered to have good outcomes while 45.7% of the patients had poor outcomes (comatose or dead) 2 weeks after the ED visit. The mean overall GCS score, verbal and motor subscores as well as the IHSS had significantly decreased (worsened) after treatment in the ED. A poor IHSS scale, hypertension, current smoking, abnormal pupillary reflexes and acidosis were associated with a worse 2-week outcome. The mean age and WBC count was lower and the mean overall GCS score and eye, verbal and motor subscores were higher as well as those having a lower IHSS scale for the good outcome category. Multivariate analysis revealed that smokers and hypertensives were at higher risk for a poor outcome. Higher eye scores on the GCS were associated fewer poor outcomes. There was significant agreement between the IHSS scale and GCS scores in the assessment of non-traumatic ASC. The sensitivity and specificity of the IHSS score versus GCS were 71.9% and 100.0%, respectively.
    Matched MeSH terms: Sensitivity and Specificity
  5. Teh LK, Lee TY, Tan JA, Lai MI, George E
    Int J Lab Hematol, 2015 Feb;37(1):79-89.
    PMID: 24725998 DOI: 10.1111/ijlh.12240
    In Malaysia, β-thalassaemia is a common inherited blood disorder in haemoglobin synthesis with a carrier rate of 4.5%. Currently, PCR-incorporating techniques such as amplification refractory mutation system (ARMS) or reverse dot blot hybridization (RDBH) are used in β-thalassaemia mutation detection. ARMS allows single-mutation identification using two reactions, one for wild type and another for mutant alleles. RDBH requires probe immobilization and optimization of hybridization and washing temperatures which is time consuming. The aim of our study was to investigate whether β-thalassaemia mutations can be identified in samples with low DNA concentrations.
    Matched MeSH terms: Sensitivity and Specificity
  6. Hashim S, Bradley DA, Saripan MI, Ramli AT, Wagiran H
    Appl Radiat Isot, 2010 Apr-May;68(4-5):700-3.
    PMID: 19892557 DOI: 10.1016/j.apradiso.2009.10.027
    This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being made to entirely enclose the fibres). The neutron irradiations were performed for exposure times of 1-, 2-, 3-, 5- and 7-days in a neutron tank filled with water. In this study, use was also made of the Monte Carlo N-particle (MCNP) code version 5 (V5) to simulate the neutron irradiations experiment. It was found that the commercially available Ge-doped and Al-doped optical fibres show a linear dose response subjected to fast neutrons from (241)AmBe source up to seven days of irradiations. The simulation performed using MCNP5 also exhibits a similar pattern, albeit differing in sensitivity. The TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre, the total absorption cross section for Ge in both the fast and thermal neutrons region being some ten times greater than that of Al.
    Matched MeSH terms: Sensitivity and Specificity
  7. Alawiah A, Bauk S, Marashdeh MW, Nazura MZ, Abdul-Rashid HA, Yusoff Z, et al.
    Appl Radiat Isot, 2015 Oct;104:197-202.
    PMID: 26188687 DOI: 10.1016/j.apradiso.2015.07.011
    In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF.
    Matched MeSH terms: Sensitivity and Specificity
  8. Ahmad Fuad Abdul Rahim, Mohd Jamil Yaacob, Muhamad Saiful Bahri Yusoff
    ASEAN Journal of Psychiatry, 2010;11(1):36-43.
    MyJurnal
    Objective: To determine the sensitivity, specificity and internal consistency of the Malay version GHQ-12 among medical student population. This study determined the appropriate GHQ-12 score to detect distressed medical students. Methods: The Malay version of GHQ-12 was derived based on two sources which were the original version GHQ-12 and the validated Malay version 30-items GHQ. The GHQ-12 and the Malay version Beck Depression Inventory-II (BDI-II) were administered to a total of 141 medical students. Distress diagnoses were made based on the Malay version BDI-II. ROC curve analysis was applied to determine the sensitivity and specificity of the GHQ-12 by testing against the BDI-II. Reliability analysis (Cronbach’s alpha and item total correlation) was applied to test internal consistency of the
    GHQ-12. The analysis was done using SPSS version 12.Results: The GHQ-12 sensitivity and specificity at cut-off point of 3/4 was 81.3% and 75.3% respectively with positive predictive value (PPV) of 62.9% as well as area under ROC curve more than 0.7. The Cronbach’s alpha value of the GHQ-12 was 0.85.Conclusion: This study showed the Malay version GHQ-12 is a valid and reliable screening tool in detecting distressed medical students. The
    GHQ-12 score equal to or more than 4 was considered as significant distress.
    Matched MeSH terms: Sensitivity and Specificity
  9. Yusoff MSB
    MyJurnal
    Objective: To determine the sensitivity, specificity and internal consistency of the Malay version GHQ-30 among medical student population. This study also determined the level of agreement between GHQ-30 and M-BDI.
    Methods: The Malay version GHQ-30 and Malay version Beck Depression Inventory (M-BDI) were administered to 190 medical students. ROC curve analysis was applied to determine the sensitivity and specificity of the GHQ-30 by testing against the M-BDI diagnoses. Reliability and Kappa analysis were applied to test internal consistency of the GHQ and to determine the level of agreement between GHQ-30 and M-BDI respectively.
    Results: 141 (74.2%) medical students participated in this study. The GHQ-30 sensitivity and specificity at cut-off point of 5/6 was 87.5% and 80.6% respectively with positive predictive value (PPV) of 70% as well as area under ROC curve was 0.84. The Cronbach’s alpha value of the GHQ-30 was 0.93. The Kappa coefficient was 0.64 (p<0.001).
    Conclusion: This study showed the Malay version GHQ-30 is a valid and reliable screening tool in detecting distressed medical students. The GHQ-30 score equal to or more than 6 was considered as significant distress. The GHQ-30 showed a good level of agreement with M-BDI in detecting distressed medical students.
    Keywords: Kelantan; Malaysia; medical student
    Matched MeSH terms: Sensitivity and Specificity
  10. Norzailin AB, Noor Azman S, Mohd Helmee MN, Khairul Anuar Z
    Med J Malaysia, 2016 02;71(1):1-7.
    PMID: 27130735
    OBJECTIVE: The purpose of the study was to determine the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of post mortem computed tomography (PMCT) in detecting liver and splenic injuries due to road traffic accidents.

    MATERIAL & METHOD: 61 road traffic accidental death cases underwent both PMCT and conventional autopsy. The imaging findings were compared to the conventional autopsy findings.

    RESULT: The sensitivity, specificity, PPV and NPV for liver injuries in PMCT was 71%, 82%, 68% and 85% while that of splenic injuries was 73%, 80%, 55% and 90% respectively. The accuracy of PMCT scan was 79% for both liver and splenic injuries. There is strong association between lower left ribs fracture and splenic injury (p=0.005) and significant association between positive liver and splenic PMCT finding and intraabdominal fatal injury (p=0.037).

    CONCLUSION: In conclusion PMCT has high specificity and NPV for liver and splenic injuries; however the sensitivity and PPV are low. The overall accuracy is not high enough to enable PMCT to be used as a replacement for conventional autopsy; however it is a useful complementary examination and has potential to be used as decision making tool for selective internal autopsy.

    Matched MeSH terms: Sensitivity and Specificity
  11. Quek KF, Low WY, Razack AH, Chua CB, Loh CS
    Med J Malaysia, 2003 Aug;58(3):356-64.
    PMID: 14750375
    This study aimed to assess the sensitivity of the Malay version of the Brief Manual Sexual Function Inventory (BMSFI) on patients with and without urinary symptoms in Malaysian population. Validity and reliability were studied in patients with lower urinary tract symptoms (LUTS) and patients without LUTS. Reliability and validity was evaluated by using the test-retest method while internal consistency was assessed by Cronbach's alpha. Sensitivity to change was expressed as the effect size in the pre-intervention versus post-intervention score in patients who underwent transurethral resection of the prostate (TURP). Internal consistency was excellent. A high degree of internal consistency was observed for each of the 11 items and 5 domains (Cronbach's alpha value = 0.67 and higher and 0.73 and higher respectively). Test-retest correlation coefficient for the 11 items scores was highly significant. Intraclass correlation coefficient was high (ICC = 0.68 and above). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significant level between baseline and post-treatment scores were observed across 3 domains in the treatment corresponds cohort but not in the control group. The Mal-BMSFI is a suitable, reliable, valid and sensitive to clinical change in the Malaysian population.
    Matched MeSH terms: Sensitivity and Specificity
  12. Tan NH, Abu M, Woo JL, Tahir HM
    Aust N Z J Obstet Gynaecol, 1995 Feb;35(1):42-5.
    PMID: 7771998 DOI: 10.1111/j.1479-828x.1995.tb01828.x
    Transvaginal sonography was performed in 70 patients diagnosed to have placenta praevia by transabdominal sonography. The diagnosis was confirmed either by digital examination in theatre at term or operative finding at delivery. Forty-nine cases (70%) were correctly diagnosed to have placenta praevia by both modes of sonography. Transvaginal sonography ruled out placenta praevia in 12 cases (17%) thought to be placenta praevia by transabdominal ultrasound. Both transabdominal and transvaginal sonography demonstrated 'placental migration' in 4 cases (6%) which were no longer praevia at delivery. Five patients (7%) were erroneously believed to have placenta praevia by both sonographic techniques. Overall, the diagnostic accuracy of transvaginal sonography was 92.8% compared with 75.7% for transabdominal sonography. None of the subjects experienced any exacerbation of bleeding or other complications. The results suggest that transvaginal sonographic localization of the placenta is safe and superior to the transabdominal route.
    Matched MeSH terms: Sensitivity and Specificity
  13. Zairul-Nizam ZF, Hyzan MY, Gobinder S, Razak MA
    Med J Malaysia, 2000 Dec;55(4):433-8.
    PMID: 11221154
    We attempted to compare the accuracy of our clinical examination and the usage of magnetic resonance imaging (MRI) in evaluating patients suspected of having internal derangement of the knee who were seen in our Orthopaedic clinic. This was done using the findings of arthroscopy as the 'gold standard'. The accuracy of MRI in detecting cruciate ligament tears was between 80-96% against 82-93% for clinical examination. MRI accuracy for meniscus injuries was 80-84% compared to 48-65% for clinical examination. We thus propose that MRI examination is an effective first-line investigation for patients with suspected internal knee derangement, especially menisci injuries; allowing arthroscopy to be reserved for patients in whom surgery is truly indicated.

    Study site: Orthopedic clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM)
    Matched MeSH terms: Sensitivity and Specificity
  14. Chang TC, Cheng HH
    Med J Malaysia, 1994 Dec;49(4):351-4.
    PMID: 7545778
    The use of maternal age alone to identify pregnant mothers at risk of a fetus with Down's syndrome has recently been supplemented by maternal serum screening using biochemical markers such as alpha-protein, human chorionic gonadotrophin and oestriol. These tests have been reported to increase the sensitivity of antenatal detection of such fetuses from 35% to 67% with a false positive rate of 5%. However, these maternal serum markers may be affected by maternal weight, the smoking history of mothers and diabetes mellitus. Furthermore, such sensitivities are achieved only when gestational age is assessed accurately by ultrasound. Many further studies need to be carried out before the introduction of maternal serum screening into routine obstetric practice in Singapore. These include studies on the incidence of Down's syndrome in the local population, studies on the distribution of these serum markers in the second trimester of pregnancy, sensitivities and positive predictive values of such a test in the local population as well as the socio-economic implications of implementing such a screening test in the local obstetric population.
    Matched MeSH terms: Sensitivity and Specificity
  15. Chong WL, Sahabudin RM, Teh GC, Woo SYY, Lim TC, Khairullah A
    Med J Malaysia, 2001 Jun;56(2):167-73.
    PMID: 11771076
    DRE has been used as a diagnostic and screening tool for prostate cancer for decades. However these are based on Western data and its local applicability has yet to be verified. We held a Prostate Health Awareness Week in August 1998 and a total of 2086 men were screened. All men aged 50 years old and above were included for the study. The subjects were evaluated on DRE findings, PSA levels and if indicated a TRUS-guided biopsy results. We concluded that DRE per se might have limited role in the screening of prostate cancer in Malaysia. Screening using DRE and PSA combined are still recognized as the most cost-effective means. Neither DRE nor PSA alone has high enough specificity for diagnosis of prostate cancer cases. Combining DRE and PSA will definitely increase the specificity significantly.

    Study site: e Urology
    Clinic of Kuala Lumpur Hospital
    Matched MeSH terms: Sensitivity and Specificity
  16. Lai FM, Paramsothy M, George J, Yip CH
    Singapore Med J, 1996 Jun;37(3):261-3.
    PMID: 8942223
    This paper illustrates the role of 99m-Technetium(Tc) diethyl-iminodiacetic acid (EHIDA) hepatobiliary scintigraphy in a patient who developed obstructive jaundice as a result of afferent loop syndrome, which is a rare occurrence. The computed tomographic (CT) and ultrasonographic findings are also described.
    Matched MeSH terms: Sensitivity and Specificity
  17. Lai FM, Liam CK, Paramsothy M, George J
    Int J Tuberc Lung Dis, 1997 Dec;1(6):563-9.
    PMID: 9487455
    University Hospital, Kuala Lumpur, Malaysia.
    Matched MeSH terms: Sensitivity and Specificity
  18. Ding CH, Ismail Z, Sulong A, Wahab AA, Gan B, Mustakim S, et al.
    Malays J Pathol, 2020 Dec;42(3):401-407.
    PMID: 33361721
    INTRODUCTION: Rifampicin is a key first-line antimycobacterial agent employed for the treatment of pulmonary tuberculosis (PTB). This study sought to obtain prevalence data on rifampicin-resistant Mycobacterium tuberculosis among smear-positive PTB patients in the Klang District of Malaysia.

    MATERIALS AND METHODS: A total of 103 patients from the Chest Clinic of Hospital Tengku Ampuan Rahimah with sputum smears positive for acid-fast bacilli were included in this cross-sectional study. All sputa were tested using Xpert MTB/RIF to confirm the presence of M. tuberculosis complex and detect rifampicin resistance. Sputa were also sent to a respiratory medicine institute for mycobacterial culture. Positive cultures were then submitted to a reference laboratory, where isolates identified as M. tuberculosis complex underwent drug susceptibility testing (DST).

    RESULTS: A total of 58 (56.3%) patients were newly diagnosed and 45 (43.7%) patients were previously treated. Xpert MTB/RIF was able to detect rifampicin resistance with a sensitivity and specificity of 87.5% and 98.9%, respectively. Assuming that a single resistant result from Xpert MTB/RIF or any DST method was sufficient to denote resistance, a total of 8/103 patients had rifampicinresistant M. tuberculosis. All eight patients were previously treated for PTB (p<0.05). The overall prevalence of rifampicin resistance among smear-positive PTB patients was 7.8%, although it was 17.8% among the previously treated ones.

    CONCLUSION: The local prevalence of rifampicin-resistant M. tuberculosis was particularly high among previously treated patients. Xpert MTB/RIF can be employed in urban district health facilities not only to diagnose PTB in smear-positive patients, but also to detect rifampicin resistance with good sensitivity and specificity.

    Matched MeSH terms: Sensitivity and Specificity
  19. Mohamed, F.A., Ong, L.Y., Ng, C.G.
    MyJurnal
    Positive emotion is often neglected in the depressed patients due to the lack of assessment tool. Positive Emotion Rating Scale (PERS) is a newly invented self-report questionnaire, nevertheless has an impressive psychometric properties.
    Objective: The aim of this study was to study the psychometric properties of the Malay version PERS (PERS-M), in order to facilitate its use in the local setting.
    Method: In this cross-sectional study convenient sampling, total of 43 depressed subjects and 85 non-depressed subjects who were presented to the outpatient clinic of HBUK were recruited. Both groups were assessed with PERS-M, original PERS, Dispositional Positive Emotion Scale (DPES), Malay version of Snaith-Hamilton Pleasure Scale (SHAPS-M) and Malay version of Center for Epidemiological Studies Depression CESDM).
    Results: PERS-M displayed good internal consistency (Cronbach’s α = 0.89), parallel reliability (intraclasss coefficient = 0.95, p<0.001) and concurrent validity with the DPES (r=0.32, p<0.05) and SHAPS-M (r=0.77, p<0.01). The PERS-M was negatively correlated with CESD-M (r= -0.61, p<0.01). The optimal cut-off value was 32, with sensitivity = 0.68 and specificity = 0.63, positive predictive value of 0.49 and negative predictive value of 0.79. The area under the curve (AUC) for receiver operating characteristic (ROC) was 0.71 (95% CI = 0.604 - 0.813).
    Conclusion: the PERS-M is a brief and easy to administer tool to measure positive emotion in depressed subjects, with demonstrable satisfactory psychometric properties.
    Keywords: Positive Emotion, Depression, Psychometric Properties, Instrument
    Study site: Psychiatric clinic, Hospital Bahagia Ulu Kinta, Perak, Malaysia
    Matched MeSH terms: Sensitivity and Specificity
  20. Low GKK, Gan SC, Zainal N, Naidu KD, Amin-Nordin S, Khoo CS, et al.
    Pathog Glob Health, 2018 09;112(6):334-341.
    PMID: 30246621 DOI: 10.1080/20477724.2018.1516417
    This study aimed to evaluate vascular endothelial growth factor (VEGF) and pentraxin 3 (PTX-3) as predictive and diagnostic markers in differentiating severe dengue from non-severe dengue. The study was conducted in Ampang Health Clinic, Ampang Hospital and Serdang Hospital. The plasma levels of VEGF and PTX-3 were compared between severe dengue and non-severe dengue by ELISA from the day of presentation until discharged. Multiple logistic regression was used to develop predictive and diagnostic models by incorporating other clinical parameters. The receiver operating characteristics (ROC) analysis was used to assess the accuracy of the biomarkers and the developed models. Eighty-two patients were recruited, 29 with severe dengue and four died. The Area Under the Curve (AUC) was statistically significant in VEGF as diagnostic marker at Day 2 and 3 of illness with sensitivity of 80.00%-100.00% and specificity of 76.47%-80.00%. The predictive model with AUC of 0.84 (p 
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links