Displaying publications 121 - 139 of 139 in total

Abstract:
Sort:
  1. Seow LL, Toh CG, Fok AS, Wilson NH
    Am J Dent, 2008 Oct;21(5):331-6.
    PMID: 19024261
    PURPOSE: To investigate the level and distribution of stresses in endodontically treated maxillary premolar teeth restored using various cavity designs of bonded all-ceramic restorations. The hypothesis tested was that the various all-ceramic approaches, including incorporating a pulp chamber extension in the restoration, had no influence on the stresses in the restored tooth unit.
    METHODS: Finite element packages Patran and Abaqus were used for the stress analysis. The cavity designs investigated include: (1) inlay (I); (2) inlay with palatal cusp coverage (IPC); (3) onlay (O); (4) inlay with pulp chamber extension (IPE); (5) inlay with palatal cusp coverage and pulp chamber extension (IPCPE); and (6) onlay with pulp chamber extension (OPE).
    RESULTS: In each case, tensile stresses were found to be concentrated subjacent to the occlusal fossa. Peak tensile stress and peak shear stress values along the tooth/restoration interface for IPC, O IPCPE and OPE cavity designs were found to be associated with the axiogingival line angle. Overall, the order of the various forms of restoration investigated in terms of the maximum principal stress (from greatest to lowest) was as follows: IPE > IPCPE > OPE > I > IPC > O.
    Matched MeSH terms: Finite Element Analysis
  2. Moo EK, Osman NA, Pingguan-Murphy B, Abas WA, Spence WD, Solomonidis SE
    Acta Bioeng Biomech, 2009;11(4):37-43.
    PMID: 20405814
    Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.
    Matched MeSH terms: Finite Element Analysis
  3. Banabilh SM, Suzina AH, Dinsuhaimi S, Singh GD
    Aust Orthod J, 2007 Nov;23(2):89-95.
    PMID: 18200785
    Obstructive sleep apnoea (OSA) has been described as a public health problem comparable to smoking in its impacts upon society.
    Matched MeSH terms: Finite Element Analysis
  4. Banabilh SM, Rajion ZA, Samsudin R, Singh GD
    Aust Orthod J, 2006 Nov;22(2):99-103.
    PMID: 17203572
    To quantify and localise differences in Class I and Class II dental arches in Malay schoolchildren.
    Matched MeSH terms: Finite Element Analysis
  5. Bajuri MN, Isaksson H, Eliasson P, Thompson MS
    Biomech Model Mechanobiol, 2016 12;15(6):1457-1466.
    PMID: 26951049
    The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties, and in some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. Computational mechanobiology methods employed extensively to model bone healing have achieved high fidelity. This study aimed to investigate whether an established hyperelastic fibre-reinforced continuum model introduced by Gasser, Ogden and Holzapfel (GOH) can be used to capture the mechanical behaviour of the Achilles tendon under loading during discrete timepoints of the healing process and to assess the model's sensitivity to its microstructural parameters. Curve fitting of the GOH model against experimental tensile testing data of rat Achilles tendons at four timepoints during the tendon repair was used and achieved excellent fits ([Formula: see text]). A parametric sensitivity study using a three-level central composite design, which is a fractional factorial design method, showed that the collagen-fibre-related parameters in the GOH model-[Formula: see text] and [Formula: see text]-had almost equal influence on the fitting. This study demonstrates that the GOH hyperelastic fibre-reinforced model is capable of describing the mechanical behaviour of healing tendons and that further experiments should focus on establishing the structural and material parameters of collagen fibres in the healing tissue.
    Matched MeSH terms: Finite Element Analysis
  6. Kosalishkwaran G, Parasuraman S, Singh DKJ, Natarajan E, Elamvazuthi I, George J
    Med Biol Eng Comput, 2019 Oct;57(10):2305-2318.
    PMID: 31444622 DOI: 10.1007/s11517-019-02026-6
    Degenerative disc disease (DDD) is a common condition in elderly population that can be painful and can significantly affect individual's quality of life. Diagnosis of DDD allows prompt corrective actions but it is challenging due to the absence of any symptoms at early stages. In studying disc degeneration, measurement of the range of motion (RoM) and loads acting on the spine are crucial factors. However, direct measurement of RoM involves increased instrumentation and risk. In this paper, an innovative method is proposed for calculating RoM, emphasizing repeatability and reliability by considering the posterior thickness of the spine. This is achieved by offsetting the position of markers in relation to the actual vertebral loci. Three geometrically identical finite element models of L3-L4 are developed from a CT scan with different types of elements, and thereafter, mesh element-related metrics are provided for the assessment of the quality of models. The model with the best mesh quality is used for further analysis, where RoM are within ranges as reported in literature and in vivo experiment results. Various kinds of stresses acting on individual components including facet joints are analysed for normal and abnormal loading conditions. The results showed that the stresses in abnormal load conditions for all components including cortical (76.67 MPa), cancellous (69.18 MPa), annulus (6.30 MPa) and nucleus (0.343 MPa) are significantly greater as compared to normal loads (49.96 MPa, 44.2 MPa, 4.28 MPa and 0.23 MPa respectively). However, stress levels for both conditions are within safe limits (167-215 MPa for cortical, 46 MPa for the annulus and 3 MPa for facets). The results obtained could be used as a baseline motion and stresses of healthy subjects based on their respective lifestyles, which could benefit clinicians to suggest corrective actions for those affected by DDD.
    Matched MeSH terms: Finite Element Analysis
  7. Masni-Azian, Tanaka M
    Comput Biol Med, 2018 07 01;98:26-38.
    PMID: 29758454 DOI: 10.1016/j.compbiomed.2018.05.010
    Intervertebral disc degeneration involves changes in its material properties that affect the mechanical functions of the spinal system. However, the alteration of the biomechanics of a spinal segment through specific material degradation in a specific region is poorly understood. In this study, the influence of the constitutive material degeneration of disc tissues on the mechanics of a lower lumbar spinal unit was examined using a three-dimensional nonlinear finite element model of the L4-L5 functional spinal unit. Different grades of disc degeneration were simulated by introducing a degeneration factor to the corresponding material properties to represent fibrous nucleus, increased fibre and ground substance laxity, increased fibre stiffness and total annular fracture along posterior and posterolateral regions. The model was loaded with an axial compression of 500 N and pure moments of up to 10 Nm to simulate extension, flexion, lateral bending and axial rotation. To validate the model, the spinal motion and intradiscal pressure of healthy and degenerated discs with existing in vitro data were compared. The disc with a fibrous nucleus and the presence of intradiscal pressure increase the spinal instability during flexion and axial rotation, and the absence of intradiscal pressure increases the spinal instability in all directions. Bulging displacement and shear strains in the disc with total fracture and ground substance laxity are high in all of the loading cases. Our study could provide useful information to enhance our understanding of the influence of each constitutive component of the intervertebral disc on the mechanics of the spinal segment.
    Matched MeSH terms: Finite Element Analysis
  8. Alsrouji MS, Ahmad R, Abdul Razak NH, Shuib S, Kuntjoro W, Baba NZ
    J Prosthodont, 2019 Feb;28(2):e764-e770.
    PMID: 30044033 DOI: 10.1111/jopr.12954
    PURPOSE: To relate the principal stress, strain, and total deformation in the premaxilla region beneath a complete denture to the pattern of premaxilla bone resorption when opposed by a conventional complete denture (CD) or by a two-implant-retained overdenture (IOD) using finite element analysis (FEA).

    MATERIALS AND METHODS: Three-dimensional solid models of the maxilla, mucosa, and denture of a selected edentulous patient were created using Mimics and CATIA software. The FEA model was created and duplicated in ANSYS 16.0 to perform two simulations for the IOD and the CD models. The values of maximum stress and strain and total deformation were obtained and compared to the outcomes of premaxilla resorption from a parallel clinical study.

    RESULTS: The maximum principal stress in the premaxilla in the IOD model ranged from 0.019 to 0.336 MPa, while it ranged from 0.011 to 0.193 MPa in the CD model. The maximum principal strain in the IOD model was 1.75 times greater than that in the CD model. Total deformation was 1.8 times higher in the IOD model. Greater bone resorption was observed in regions of higher stress, which were on the occlusal and buccal sides of the premaxilla residual ridge.

    CONCLUSION: Stress, strain, and total deformation values present in the premaxilla area beneath a CD were approximately two times greater in a comparison between an opposing mandibular two-IOD and an opposing mandibular CD. The results were consistent with a parallel clinical study in which the rate of premaxilla bone resorption was almost three times greater in the IOD group.

    Matched MeSH terms: Finite Element Analysis
  9. Wahab AHA, Saad APM, Syahrom A, Kadir MRA
    Comput Methods Biomech Biomed Engin, 2020 Apr;23(5):182-190.
    PMID: 31910663 DOI: 10.1080/10255842.2019.1709828
    Glenoid perforation is not the intended consequence of the surgery and must be avoided. The analysis on biomechanical aspect of glenoid vault perforation remains unknown. The purpose of this study is to determine the impact of glenoid perforation towards stress distribution and micromotion at the interfaces. Eight glenoid implant models had been constructed with various size, number and type of fixation. A load of 750 N was applied to centre, superior-anterior and superior-posterior area. Implant perforation had minimal impact on stress distribution and micromotion at the interfaces. However, cement survival rate for implant without perforation was the highest with a difference of up to 37% compared to other perforated models. Besides that, implant fixation and high stresses at the implant had more of an impact on implant instability than implant perforation. As a conclusion, glenoid perforation did not influence the stress distribution and micromotion, but, it reduced cement survival rate and increase the stress critical volume.
    Matched MeSH terms: Finite Element Analysis
  10. Razali MF, Mahmud AS, Mokhtar N
    J Mech Behav Biomed Mater, 2018 Jan;77:234-241.
    PMID: 28954242 DOI: 10.1016/j.jmbbm.2017.09.021
    NiTi arch wires are used widely in orthodontic treatment due to its superelastic and biocompatibility properties. In brackets configuration, the force released from the arch wire is influenced by the sliding resistances developed on the arch wire-bracket contact. This study investigated the evolution of the forces released by a rectangular NiTi arch wire towards possible intraoral temperature and deflection changes. A three dimensional finite element model was developed to measure the force-deflection behavior of superelastic arch wire. Finite element analysis was used to distinguish the martensite fraction and phase state of arch wire microstructure in relation to the magnitude of wire deflection. The predicted tensile and bending results from the numerical model showed a good agreement with the experimental results. As contact developed between the wire and bracket, binding influenced the force-deflection curve by changing the martensitic transformation plateau into a slope. The arch wire recovered from greater magnitude of deflection released lower force than one recovered from smaller deflection. In contrast, it was observed that the plateau slope increased from 0.66N/mm to 1.1N/mm when the temperature was increased from 26°C to 46°C.
    Matched MeSH terms: Finite Element Analysis
  11. Chen J, Ahmad R, Suenaga H, Li W, Swain M, Li Q
    J Biomech, 2015 Feb 5;48(3):512-9.
    PMID: 25560272 DOI: 10.1016/j.jbiomech.2014.11.043
    Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an in-silico approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6kPa and 39.9kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4kPa). Hydrostatic pressure in the mucosa signifies a critical indicator and can be correlated with clinically measured bone resorption, pointing to severer mandibular ridge resorption posteriorly with implant-retained overdentures. This study provides a biomechanical basis for denture treatment planning to improve long-term outcomes with minimal residual ridge resorption.
    Matched MeSH terms: Finite Element Analysis
  12. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Finite Element Analysis
  13. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Finite Element Analysis
  14. Banabilh SM, Suzina AH, Dinsuhaimi S, Samsudin AR, Singh GD
    J Oral Rehabil, 2009 Mar;36(3):184-92.
    PMID: 19207445 DOI: 10.1111/j.1365-2842.2008.01915.x
    The association between dental arch morphology and the aetiology of obstructive sleep apnoea (OSA) is not clear. To compare dental arch morphology in 108 Asian adults with and without ''OSA, overnight'' hospital polysomnography was performed, and sleep reports were obtained for all subjects. Standardized digital photographs were also taken of the subjects' upper and lower study models. Using 25 homologous landmarks, mean OSA and control dental arch configurations were computed, and subjected to finite-element morphometry (FEM), t-tests and principal components analysis (PCA). Mean upper and lower OSA dental arch morphologies were statistically different from respective Control upper and lower arch morphologies (P < 0.05). FEM of the upper arch indicated that the mean OSA configuration was 7-11% narrower in the transverse plane in the incisor and canine regions when compared with the control configuration, and inter-landmark analysis (ILA) confirmed this finding. FEM for the lower arch indicated that the mean OSA configuration was 10-11% narrower in the antero-posterior plane in the pre-molar and molar regions, and confirmed by ILA. Using PCA, significant differences were also found between the two groups in the lower arch using the first two eigenvalues, which accounted for 90% of the total shape change (P < 0.001). Supporting their role as aetiological factors, size and shape differences in dental arch morphology are found in patients with OSA.
    Matched MeSH terms: Finite Element Analysis
  15. Mehboob H, Tarlochan F, Mehboob A, Chang SH, Ramesh S, Harun WSW, et al.
    J Mater Sci Mater Med, 2020 Aug 20;31(9):78.
    PMID: 32816091 DOI: 10.1007/s10856-020-06420-7
    The current study is proposing a design envelope for porous Ti-6Al-4V alloy femoral stems to survive under fatigue loads. Numerical computational analysis of these stems with a body-centered-cube (BCC) structure is conducted in ABAQUS. Femoral stems without shell and with various outer dense shell thicknesses (0.5, 1.0, 1.5, and 2 mm) and inner cores (porosities of 90, 77, 63, 47, 30, and 18%) are analyzed. A design space (envelope) is derived by using stem stiffnesses close to that of the femur bone, maximum fatigue stresses of 0.3σys in the porous part, and endurance limits of the dense part of the stems. The Soderberg approach is successfully employed to compute the factor of safety Nf > 1.1. Fully porous stems without dense shells are concluded to fail under fatigue load. It is thus safe to use the porous stems with a shell thickness of 1.5 and 2 mm for all porosities (18-90%), 1 mm shell with 18 and 30% porosities, and 0.5 mm shell with 18% porosity. The reduction in stress shielding was achieved by 28%. Porous stems incorporated BCC structures with dense shells and beads were successfully printed.
    Matched MeSH terms: Finite Element Analysis
  16. Yusoff N, Abu Osman NA, Pingguan-Murphy B
    Med Eng Phys, 2011 Jul;33(6):782-8.
    PMID: 21356602 DOI: 10.1016/j.medengphy.2011.01.013
    A mechanical-conditioning bioreactor has been developed to provide bi-axial loading to three-dimensional (3D) tissue constructs within a highly controlled environment. The computer-controlled bioreactor is capable of applying axial compressive and shear deformations, individually or simultaneously at various regimes of strain and frequency. The reliability and reproducibility of the system were verified through validation of the spatial and temporal accuracy of platen movement, which was maintained over the operating length of the system. In the presence of actual specimens, the system was verified to be able to deliver precise bi-axial load to the specimens, in which the deformation of every specimen was observed to be relatively homogeneous. The primary use of the bioreactor is in the culture of chondrocytes seeded within an agarose hydrogel while subjected to physiological compressive and shear deformation. The system has been designed specifically to permit the repeatable quantification and characterisation of the biosynthetic activity of cells in response to a wide range of short and long term multi-dimensional loading regimes.
    Matched MeSH terms: Finite Element Analysis
  17. Banabilh SM, Suzina AH, Mohamad H, Dinsuhaimi S, Samsudin AR, Singh GD
    Clin Oral Investig, 2010 Oct;14(5):491-8.
    PMID: 19806371 DOI: 10.1007/s00784-009-0342-9
    The aim of the present study is to investigate nasal airway morphology in Asian adults with and without obstructive sleep apnea (OSA) using acoustic rhinometry (AR), principal components analysis (PCA), and 3-D finite-element analysis (FEA). One hundred eight adult Malays aged 18-65 years (mean ± SD, 33.2 ± 13.31) underwent clinical examination and limited channel polysomnography, providing 54 patients with OSA and 54 non-OSA controls. The mean minimal cross section area 1 (MCA1) and the mean minimal cross sectional area 2 (MCA2) were obtained from AR for all subjects and subjected to t tests. The OSA and control nasal airways were reconstructed in 3-D and subjected to PCA and FEA. The mean MCA1 and MCA2 using AR were found to be significantly smaller in the OSA group than in the control group (p < 0.001). Comparing the 3-D OSA and control nasal airways using PCA, the first two eigenvalues accounted for 94% of the total shape change, and statistical differences were found (p < 0.05). Similarly, comparing the nasal airways using FEA, the 3-D mean OSA nasal airway was significantly narrower in the OSA group compared to the control group. Specifically, decreases in size of approx. 10-22% were found in the nasal valve/head of inferior turbinate area. In conclusion, differences in nasal airway morphology are present when comparing patients with OSA to controls. These differences need to be recognized as they can improve our understanding of the etiological basis of obstructive sleep apnea and facilitate its subsequent management.
    Matched MeSH terms: Finite Element Analysis
  18. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Finite Element Analysis
  19. Mustafa AA, Matinlinna JP, Saidin S, Kadir MR
    J Prosthet Dent, 2014 Dec;112(6):1498-506.
    PMID: 24993375 DOI: 10.1016/j.prosdent.2014.05.011
    STATEMENT OF PROBLEM: The inconsistency of dentin bonding affects retention and microleakage.

    PURPOSE: The purpose of this laboratory and finite element analysis study was to investigate the effects on the formation of a hybrid layer of an experimental silane coupling agent containing primer solutions composed of different percentages of hydroxyethyl methacrylate.

    MATERIAL AND METHODS: A total of 125 sound human premolars were restored in vitro. Simple class I cavities were formed on each tooth, followed by the application of different compositions of experimental silane primers (0%, 5%, 25%, and 50% of hydroxyethyl methacrylate), bonding agents, and dental composite resins. Bond strength tests and scanning electron microscopy analyses were performed. The laboratory experimental results were validated with finite element analysis to determine the pattern of stress distribution. Simulations were conducted by placing the restorative composite resin in a premolar tooth by imitating simple class I cavities. The laboratory and finite element analysis data were significantly different from each other, as determined by 1-way ANOVA. A post hoc analysis was conducted on the bond strength data to further clarify the effects of silane primers.

    RESULTS: The strongest bond of hybrid layer (16.96 MPa) was found in the primer with 25% hydroxyethyl methacrylate, suggesting a barely visible hybrid layer barrier. The control specimens without the application of the primer and the primer specimens with no hydroxyethyl methacrylate exhibited the lowest strength values (8.30 MPa and 11.78 MPa) with intermittent and low visibility of the hybrid layer. These results were supported by finite element analysis that suggested an evenly distributed stress on the model with 25% hydroxyethyl methacrylate.

    CONCLUSIONS: Different compositions of experimental silane primers affected the formation of the hybrid layer and its resulting bond strength.

    Matched MeSH terms: Finite Element Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links