Displaying publications 121 - 140 of 169 in total

Abstract:
Sort:
  1. Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T
    Injury, 2012 Jun;43(6):898-902.
    PMID: 22204773 DOI: 10.1016/j.injury.2011.12.006
    The use of open wedge high tibial osteotomy (HTO) to correct varus deformity of the knee is well established. However, the stability of the various implants used in this procedure has not been previously demonstrated. In this study, the two most common types of plates were analysed (1) the Puddu plates that use the dynamic compression plate (DCP) concept, and (2) the Tomofix plate that uses the locking compression plate (LCP) concept. Three dimensional model of the tibia was reconstructed from computed tomography images obtained from the Medical Implant Technology Group datasets. Osteotomy and fixation models were simulated through computational processing. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect during single limb stance. The model was fixed distally in all degrees of freedom. Simulated data generated from the micromotions, displacement and, implant stress were captured. At the prescribed loads, a higher displacement of 3.25 mm was observed for the Puddu plate model (p<0.001). Coincidentally the amount of stresses subjected to this plate, 24.7 MPa, was also significantly lower (p<0.001). There was significant negative correlation (p<0.001) between implant stresses to that of the amount of fracture displacement which signifies a less stable fixation using Puddu plates. In conclusion, this study demonstrates that the Tomofix plate produces superior stability for bony fixation in HTO procedures.
    Matched MeSH terms: Imaging, Three-Dimensional
  2. Banabilh SM, Suzina AH, Dinsuhaimi S, Samsudin AR, Singh GD
    Sleep Breath, 2009 Mar;13(1):19-24.
    PMID: 18763003 DOI: 10.1007/s11325-008-0211-9
    INTRODUCTION: Obstructive sleep apnea (OSA) and obesity are serious, widespread public health issues.

    OBJECTIVE: To localize and quantify geometric morphometric differences in facial soft tissue morphology in adults with and without OSA.

    MATERIALS AND METHODS: Eighty adult Malays, consisting of 40 patients with OSA and 40 non-OSA controls, were studied. Both groups were evaluated by the attending physician and through ambulatory sleep studies. 3-D stereophotogrammetry was used to capture facial soft tissues of both groups. The 3-D mean OSA and control facial configurations were computed and subjected to principal components analysis (PCA) and finite-element morphometry (FEM).

    RESULTS: The body mass index was significantly greater for the OSA group (32.3 kg/m(2) compared to 24.8 kg/m(2), p < 0.001). The neck circumference was greater for the OSA group (42.7 cm compared to 37.1 cm, p < 0.001). Using PCA, significant differences were found in facial shape between the two groups using the first two principal components, which accounted for 50% of the total shape change (p < 0.05). Using FEM, these differences were localized in the bucco-submandibular regions of the face predominantly, indicating an increase in volume of 7-22% (p < 0.05) for the OSA group.

    CONCLUSION: Craniofacial obesity in the bucco-submandibular regions is associated with OSA and may provide valuable screening information for the identification of patients with undiagnosed OSA.

    Matched MeSH terms: Imaging, Three-Dimensional
  3. Wan Ab Naim WN, Ganesan P, Al Abed A, Lim E
    PMID: 23365977 DOI: 10.1109/EMBC.2012.6346016
    The effects of curvature and tapering on the flow progression in the aorta were studied using numerical simulations on a realistic geometrical model of the aorta and three different versions of the ideal aorta models. The results showed that tapering increases velocity magnitude and wall shear stress while local curvatures affect the skewness of the velocity profile, the thickness of the boundary layer as well as the recirculation regions. Wall shear stress distribution in the aorta serves as an important determinant in the progression of arterial disease.
    Matched MeSH terms: Imaging, Three-Dimensional
  4. Shyam Sunder R, Eswaran C, Sriraam N
    Comput Biol Med, 2006 Sep;36(9):958-73.
    PMID: 16026779
    In this paper, 3-D discrete Hartley transform is applied for the compression of two medical modalities, namely, magnetic resonance images and X-ray angiograms and the performance results are compared with those of 3-D discrete cosine and Fourier transforms using the parameters such as PSNR and bit rate. It is shown that the 3-D discrete Hartley transform is better than the other two transforms for magnetic resonance brain images whereas for the X-ray angiograms, the 3-D discrete cosine transform is found to be superior.
    Matched MeSH terms: Imaging, Three-Dimensional
  5. Damas S, Wilkinson C, Kahana T, Veselovskaya E, Abramov A, Jankauskas R, et al.
    Forensic Sci Int, 2015 Dec;257:504-508.
    PMID: 26482539 DOI: 10.1016/j.forsciint.2015.07.045
    Craniofacial superimposition, although existing for one century, is still a controversial technique within the scientific community. Objective and unbiased validation studies over a significant number of cases are required to establish a more solid picture on the reliability. However, there is lack of protocols and standards in the application of the technique leading to contradictory information concerning reliability. Instead of following a uniform methodology, every expert tends to apply his own approach to the problem, based on the available technology and deep knowledge on human craniofacial anatomy, soft tissues, and their relationships. The aim of this study was to assess the reliability of different craniofacial superimposition methodologies and the corresponding technical approaches to this type of identification. With all the data generated, some of the most representative experts in craniofacial identification joined in a discussion intended to identify and agree on the most important issues that have to be considered to properly employ the craniofacial superimposition technique. As a consequence, the consortium has produced the current manuscript, which can be considered the first standard in the field; including good and bad practices, sources of error and uncertainties, technological requirements and desirable features, and finally a common scale for the craniofacial matching evaluation. Such a document is intended to be part of a more complete framework for craniofacial superimposition, to be developed during the FP7-founded project MEPROCS, which will favour and standardize its proper application.
    Matched MeSH terms: Imaging, Three-Dimensional
  6. Ibáñez O, Vicente R, Navega DS, Wilkinson C, Jayaprakash PT, Huete MI, et al.
    Forensic Sci Int, 2015 Dec;257:496-503.
    PMID: 26060056 DOI: 10.1016/j.forsciint.2015.05.030
    As part of the scientific tasks coordinated throughout The 'New Methodologies and Protocols of Forensic Identification by Craniofacial Superimposition (MEPROCS)' project, the current study aims to analyse the performance of a diverse set of CFS methodologies and the corresponding technical approaches when dealing with a common dataset of real-world cases. Thus, a multiple-lab study on craniofacial superimposition has been carried out for the first time. In particular, 26 participants from 17 different institutions in 13 countries were asked to deal with 14 identification scenarios, some of them involving the comparison of multiple candidates and unknown skulls. In total, 60 craniofacial superimposition problems divided in two set of females and males. Each participant follow her/his own methodology and employed her/his particular technological means. For each single case they were asked to report the final identification decision (either positive or negative) along with the rationale supporting the decision and at least one image illustrating the overlay/superimposition outcome. This study is expected to provide important insights to better understand the most convenient characteristics of every method included in this study.
    Matched MeSH terms: Imaging, Three-Dimensional
  7. Chong JA, Syed Mohamed AMF, Marizan Nor M, Pau A
    J Forensic Sci, 2020 Nov;65(6):2000-2007.
    PMID: 32692413 DOI: 10.1111/1556-4029.14507
    Although there is clinical applicability of the palatal rugae as an identification tool in forensic odontology, controversy exists whether the palatal rugae patterns are stable or variable. The greater the genetic component, the higher the probability that palatal rugae patterns are stable. The aim of this study was to compare the palatal rugae morphology between full siblings and the proportion of variability due to genetic component. This cross-sectional study was conducted on digital models of 162 siblings aged 15-30 years old. The palatal rugae patterns were assessed with Thomas and Kotze (1983) classification using Geomagic Studio software (3D Systems, Rock Hill, SC). The palatal rugae morphology between siblings showed significantly similar characteristics for total number of left rugae (p = 0.001), left primary rugae (p = 0.017), secondary rugae for right (p = 0.024) and left sides (p = 0.001), right straight rugae (p = 0.010), and right convergent rugae (p = 0.005) accounting for at least 6.25%-12.8% of the variability due to heredity. Despite the similarities found, the palatal rugae patterns showed significant differences between siblings of at least 46.9% (p = 0.001). Zero heritability was found in 9 of the 14 rugae patterns. Meanwhile, total number of rugae, primary, backward, and convergent rugae showed moderate heritability (h2  > 0.3) and total number of secondary rugae showed high heritability (h2  > 0.6). In conclusion, despite the individuality characteristics, an appreciable hereditary component is observed with significant similarities found between sibling pairs and the palatal rugae patterns were both environmentally and genetically influenced.
    Matched MeSH terms: Imaging, Three-Dimensional
  8. Song MH, Kamisan N, Lim C, Shin CH, Yoo WJ, Song HR, et al.
    J Pediatr Orthop, 2021 Mar 01;41(3):e285-e290.
    PMID: 33534367 DOI: 10.1097/BPO.0000000000001739
    BACKGROUND: Osteogenesis imperfecta (OI) can develop a protrusio acetabuli deformity. However, the authors observed a pseudo-protrusio-type acetabular deformity (PPAD) on 3-dimensional computed tomography (3D-CT). Hence, we systematically reviewed 3D-CT and pelvis radiographs of OI patients and report the incidence and patterns of acetabular deformity in OI patients and the associated radiographic signs.

    METHODS: The study included 590 hips of 295 OI patients, who were older than 5 years, and did not have a pelvic fracture. The incidence of a deformed acetabulum (center-edge angle >40 degrees) and its correlation with disease severity were investigated. In 40 hips for which 3D-CT was available, 3-dimensional morphology of the acetabular deformity was analyzed to delineate PPAD. On plain radiographs, PPAD-related signs were determined, focusing on the contour of ilioischial line, iliopectineal line, acetabular line, and their relationship. These radiographic signs were also evaluated in the remaining hips with deformed acetabula that did not have 3D-CT.

    RESULTS: One hundred twenty-three hips of 590 hips (21%) showed deformed acetabula. The incidence of deformed acetabula was significantly associated with disease severity (P<0.001). Three-dimensional analysis showed that 10 hips had protrusio acetabuli, whereas 17 had PPAD, which showed that the hemipelvis was crumpled, the acetabular roof was rotated upwardly and medially, and the hip center migrated superiorly, uncovering the anterior femoral head. Among the PPAD-related signs, superomedial bulging of the iliopectineal line was the most predictive radiographic sign (73% sensitivity and 100% specificity). This sign was also observed in almost one third of deformed acetabula of those investigated only with plain radiographs.

    CONCLUSIONS: This study showed that acetabular deformity is common in OI patients and is associated with disease severity. A substantial number of hips showed PPAD, which may not cause femoroacetabular impingement but result in anterior uncovering of the hip joint. Superomedial bulging of the iliopectineal line suggests this pattern of acetabular deformity.

    LEVEL OF EVIDENCE: Lever IV-prognostic studies.

    Matched MeSH terms: Imaging, Three-Dimensional
  9. Sim GS, Wong JH, Ng KH
    J Appl Clin Med Phys, 2013 Jul 08;14(4):4182.
    PMID: 23835383 DOI: 10.1120/jacmp.v14i4.4182
    Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.
    Matched MeSH terms: Imaging, Three-Dimensional
  10. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Imaging, Three-Dimensional
  11. Iranpour F, Merican AM, Teo SH, Cobb JP, Amis AA
    Knee, 2017 Jun;24(3):555-563.
    PMID: 28330756 DOI: 10.1016/j.knee.2017.01.011
    BACKGROUND: Patellofemoral instability is a major cause of anterior knee pain. The aim of this study was to examine how the medial and lateral stability of the patellofemoral joint in the normal knee changes with knee flexion and measure its relationship to differences in femoral trochlear geometry.

    METHODS: Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum.

    RESULTS: The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, p<0.0001).

    CONCLUSIONS: These results provide objective evidence relating the changes of femoral profile geometry with knee flexion to patellofemoral stability.

    Matched MeSH terms: Imaging, Three-Dimensional
  12. Paka C, Kamisan Atan I, Rios R, Dietz HP
    Female Pelvic Med Reconstr Surg, 2016 10 27;23(4):238-243.
    PMID: 27782978 DOI: 10.1097/SPV.0000000000000350
    OBJECTIVE: The aim of this study was to investigate the association of the anatomic integrity of the external anal sphincter (EAS) detected on transperineal ultrasound (TPUS) with symptoms of anal incontinence (AI) as measured by St Mark's Incontinence Score (SMIS) and the visual analog scale (VAS).

    METHODS: This is an observational, cross-sectional analysis of 486 women who presented to a tertiary urogynecological center between May 2013 and August 2014. They underwent a standardized interview and an examination that involved 3-dimensional/4-dimensional TPUS. The SMIS and VAS were administered if they answered positively to a question on AI. The association between defects of the EAS and symptoms of AI was evaluated using bivariate tests, as well as adjusting for pertinent covariates using multiple linear regression modeling.

    RESULTS: Of the included patients, 17.1% reported AI, and 15.2% had significant EAS defects (≥4 slices) on TPUS imaging. A significant sonographic defect was diagnosed in 23% of women with AI versus 14% of those without (P = 0.033). Women with symptoms of AI were more likely to have a significant defect on TPUS (odds ratio, 1.878; 95% confidence interval, 1.05-3.37). No significant findings were seen when analyzing SMIS, its components, and VAS against sonographic EAS defects.

    CONCLUSIONS: The symptom of AI is associated with significant EAS defects detected on TPUS. However, this study failed to show an association between significant EAS defects and the SMIS and VAS.

    Matched MeSH terms: Imaging, Three-Dimensional
  13. Masni-Azian, Tanaka M
    Comput Biol Med, 2018 07 01;98:26-38.
    PMID: 29758454 DOI: 10.1016/j.compbiomed.2018.05.010
    Intervertebral disc degeneration involves changes in its material properties that affect the mechanical functions of the spinal system. However, the alteration of the biomechanics of a spinal segment through specific material degradation in a specific region is poorly understood. In this study, the influence of the constitutive material degeneration of disc tissues on the mechanics of a lower lumbar spinal unit was examined using a three-dimensional nonlinear finite element model of the L4-L5 functional spinal unit. Different grades of disc degeneration were simulated by introducing a degeneration factor to the corresponding material properties to represent fibrous nucleus, increased fibre and ground substance laxity, increased fibre stiffness and total annular fracture along posterior and posterolateral regions. The model was loaded with an axial compression of 500 N and pure moments of up to 10 Nm to simulate extension, flexion, lateral bending and axial rotation. To validate the model, the spinal motion and intradiscal pressure of healthy and degenerated discs with existing in vitro data were compared. The disc with a fibrous nucleus and the presence of intradiscal pressure increase the spinal instability during flexion and axial rotation, and the absence of intradiscal pressure increases the spinal instability in all directions. Bulging displacement and shear strains in the disc with total fracture and ground substance laxity are high in all of the loading cases. Our study could provide useful information to enhance our understanding of the influence of each constitutive component of the intervertebral disc on the mechanics of the spinal segment.
    Matched MeSH terms: Imaging, Three-Dimensional
  14. Jayaprakash PT
    Forensic Sci Int, 2017 Sep;278:411.e1-411.e8.
    PMID: 28754256 DOI: 10.1016/j.forsciint.2017.04.021
    Often cited reliability test on video superimposition method integrated scaling face-images in relation to skull-images, tragus-auditory meatus relationship in addition to exocanthion-Whitnall's tubercle relationship when orientating the skull-image and wipe mode imaging in addition to mix mode imaging when obtaining skull-face image overlay and evaluating the goodness of match. However, a report that found higher false positive matches in computer assisted superimposition method transited from the above foundational concepts and relied on images of unspecified sizes that are lesser than 'life-size', frontal plane landmarks in the skull- and face- images alone for orientating the skull-image and mix images alone for evaluating the goodness of match. Recently, arguing the use of 'life-size' images as 'archaic', the authors who tested the reliability in the computer assisted superimposition method have denied any method transition. This article describes that the use of images of unspecified sizes at lesser than 'life-size' eliminates the only possibility to quantify parameters during superimposition which alone enables dynamic skull orientation when overlaying a skull-image with a face-image in an anatomically acceptable orientation. The dynamic skull orientation process mandatorily requires aligning the tragus in the 2D face-image with the auditory meatus in the 3D skull-image for anatomically orientating the skull-image in relation to the posture in the face-image, a step not mentioned by the authors describing the computer assisted superimposition method. Furthermore, mere reliance on mix type images during image overlay eliminates the possibility to assess the relationship between the leading edges of the skull- and face-image outlines as also specific area match among the corresponding craniofacial organs during superimposition. Indicating the possibility of increased false positive matches as a consequence of the above method transitions, the need for testing the reliability in the superimposition method adopting concepts that are considered safe is stressed.
    Matched MeSH terms: Imaging, Three-Dimensional
  15. Marroquin Penaloza TY, Karkhanis S, Kvaal SI, Nurul F, Kanagasingam S, Franklin D, et al.
    J Forensic Leg Med, 2016 Nov;44:178-182.
    PMID: 27821308 DOI: 10.1016/j.jflm.2016.10.013
    Different non-invasive methods have been proposed for dental age estimation in adults, with the Kvaal et al. method as one of the more frequently tested in different populations. The purpose of this study was to apply the Kvaal et al. method for dental age estimation on modern volumetric data from 3D digital systems. To this end, 101 CBCT images from a Malaysian population were used. Fifty-five per cent were female (n = 55), and forty-five percent were male (n = 46), with a median age of 31 years for both sexes. As tomographs allow the observer to obtain a sagittal and coronal view of the teeth, the Kvaal pulp/root width measurements and ratios were calculated in the bucco-lingual and mesio-distal aspects of the tooth. From these data different linear regression models and formulae were built. The most accurate models for estimating age were obtained from a diverse combination of measurements (SEE ±10.58 years), and for the mesio-distal measurements of the central incisor at level A (SEE ±12.84 years). This accuracy, however is outside an acceptable range in for forensic application (SEE ±10.00 years), and is also more time consuming than the original approach based on dental radiographs.
    Matched MeSH terms: Imaging, Three-Dimensional
  16. Ibrahim RW, Hasan AM, Jalab HA
    Comput Methods Programs Biomed, 2018 Sep;163:21-28.
    PMID: 30119853 DOI: 10.1016/j.cmpb.2018.05.031
    BACKGROUND AND OBJECTIVES: The MRI brain tumors segmentation is challenging due to variations in terms of size, shape, location and features' intensity of the tumor. Active contour has been applied in MRI scan image segmentation due to its ability to produce regions with boundaries. The main difficulty that encounters the active contour segmentation is the boundary tracking which is controlled by minimization of energy function for segmentation. Hence, this study proposes a novel fractional Wright function (FWF) as a minimization of energy technique to improve the performance of active contour without edge method.

    METHOD: In this study, we implement FWF as an energy minimization function to replace the standard gradient-descent method as minimization function in Chan-Vese segmentation technique. The proposed FWF is used to find the boundaries of an object by controlling the inside and outside values of the contour. In this study, the objective evaluation is used to distinguish the differences between the processed segmented images and ground truth using a set of statistical parameters; true positive, true negative, false positive, and false negative.

    RESULTS: The FWF as a minimization of energy was successfully implemented on BRATS 2013 image dataset. The achieved overall average sensitivity score of the brain tumors segmentation was 94.8 ± 4.7%.

    CONCLUSIONS: The results demonstrate that the proposed FWF method minimized the energy function more than the gradient-decent method that was used in the original three-dimensional active contour without edge (3DACWE) method.

    Matched MeSH terms: Imaging, Three-Dimensional
  17. Alsrouji MS, Ahmad R, Rajali A, Mustafa NWNA, Ibrahim N, Baba NZ
    J Prosthodont, 2019 Feb;28(2):131-137.
    PMID: 30427557 DOI: 10.1111/jopr.12999
    PURPOSE: To compare the residual ridge resorption (RRR) of the anterior maxillary bone beneath complete dentures when opposed by mandibular complete dentures (CD) and implant-retained overdentures (IRO).

    MATERIALS AND METHODS: 18 patients were rehabilitated with maxillary CD opposing mandibular IRO, and 4 patients were prescribed with conventional CD. Cone beam computed tomography (CBCT) scans of the maxilla were acquired before and 1 year post-treatment and converted into 3D models using Mimics research software. RRR was quantified by measuring the changes in bone volume following superimpositioning and sectioning of these models at the anterior maxillary region. Subsequently, the sectioned 3D models of the anterior maxilla were exported to 3-Matic software to reveal the predominant region and depth of RRR.

    RESULTS: The mean reduction in bone volume of the anterior maxilla in the CD group was 2.60% (SD = 1.71%, range = -4.89 % to -0.92%, median = -2.30%), while the mean reduction in the IRO group was almost three times higher at 7.25% (SD = 3.16%, range = -13.25 to -1.50, median = -7.15%). The predominant areas of RRR were on the buccal and occlusal ridge of the anterior maxilla.

    CONCLUSION: Within the limits of this study, it may be concluded that an IRO caused significantly higher RRR of the anterior maxilla than a CD.

    Matched MeSH terms: Imaging, Three-Dimensional
  18. Alias A, Ibrahim A, Abu Bakar SN, Swarhib Shafie M, Das S, Abdullah N, et al.
    Clin Ter, 2018 11 6;169(5):e217-e223.
    PMID: 30393808 DOI: 10.7417/CT.2018.2082
    INTRODUCTION: The first step in the forensic identification is sex determination followed by age and stature estimation, as both are sex-dependent. The mandible is the largest, strongest and most durable bone in the face. Mandible is important for sex confirmation in absence of a complete pelvis and skull.

    AIM: The aim of the present study was to determine sex of human mandible from morphology, morphometric measurements as well as discriminant function analysis from the CT scan.

    MATERIALS AND METHODS: The present retrospective study comprised 79 subjects (48 males, 31 females), with age group between 18 and 74 years, and were obtained from the post mortem computed tomography data in the Hospital Kuala Lumpur. The parameters were divided into three morphologic and nine morphometric parameters, which were measured by using Osirix MD Software 3D Volume Rendering.

    RESULTS: The Chi-square test showed that men were significantly association with square-shaped chin (92%), prominent muscle marking (85%) and everted gonial glare, whereas women had pointed chin (84%), less prominent muscle marking (90%) and inverted gonial glare (80%). All parameter measurements showed significantly greater values in males than in females by independent t-test (p< 0.01). By discriminant analysis, the classification accuracy was 78.5%, the sensitivity was 79.2% and the specificity was 77.4%. The discriminant function equation was formulated based on bigonial breath and condylar height, which were the best predictors.

    CONCLUSION: In conclusion, the mandible could be distinguished according to the sex. The results of the study can be used for identification of damaged and/or unknown mandible in the Malaysian population.

    Matched MeSH terms: Imaging, Three-Dimensional
  19. Wee LK, Chai HY, Samsury SR, Mujamil NF, Supriyanto E
    An Acad Bras Cienc, 2012 Dec;84(4):1157-68.
    PMID: 23207710
    Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
    Matched MeSH terms: Imaging, Three-Dimensional
  20. Kamangar S, Badruddin IA, Badarudin A, Nik-Ghazali N, Govindaraju K, Salman Ahmed NJ, et al.
    Comput Methods Biomech Biomed Engin, 2017 Mar;20(4):365-372.
    PMID: 27612619 DOI: 10.1080/10255842.2016.1233402
    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.
    Matched MeSH terms: Imaging, Three-Dimensional
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links