Displaying publications 141 - 160 of 340 in total

Abstract:
Sort:
  1. Lee AV, Pang HC, Linus Lojikip S, Wong KW, Goh KW, Chan FS
    Med J Malaysia, 2020 03;75(2):152-157.
    PMID: 32281597
    OBJECTIVES: To explore the epidemiological and histopathological patterns of glomerular diseases in Sabah.

    METHODS: A state-wide cross-sectional study was conducted. There were 336 native renal biopsies in 296 eligible patients from 1st January 2013 to 30th June 2016. All patients aged ≥12 years with sufficient sampling (≥8 glomeruli) for histopathological assessment were included. Graft kidney biopsies, protocol-based biopsies and patients with uncertain demographics were excluded. Demographics of patients, clinical data, laboratory parameters prior to biopsy, and histology findings of renal biopsies were collected from local unit database and recorded into a standardised data collection form. Descriptive statistical analyses were employed and factors associated with Lupus nephritis (LN) were explored using logistic regression.

    RESULTS: The mean age during biopsy was 34.53 years (Standard Deviation 0.759). Primary glomerulonephritis (PGN) accounted for 42.6% (126) of all native renal biopsies. The commonest cause of PGN was minimal change disease (38.9%, 49) followed by focal segmental glomerulosclerosis (33.3%, 42) and IgA nephropathy (14.3%, 18). LN is the leading cause for secondary glomerulonephritis (SGN) (87.2%, 136). Younger age (Odds Ratio, OR 0.978; 95% Confidence Interval, 95%CI 0.960, 0.996); female gender (OR 17.53; p<0.001); significant proteinuria (OR 132.0; p<0.001); creatinine level at biopsy (OR 11.26; p=0.004); positive antinuclear antibody (ANA) (OR 46.7; p<0.001); and ANA patterns (OR 8.038; p=0.018) were significant in predicting the odds of having LN.

    CONCLUSION: This is the first epidemiology study of glomerular diseases in Sabah. The predominance of LN suggests lower threshold for renal biopsy in patients with suspected glomerular disorders. We have identified significant predictors for early detection and treatment of LN.

    Matched MeSH terms: Reference Standards
  2. Gan KML, Oei JL, Quah-Smith I, Kamar AA, Lordudass AAD, Liem KD, et al.
    Front Pediatr, 2020;8:615008.
    PMID: 33425820 DOI: 10.3389/fped.2020.615008
    Background: Eye exam for Retinopathy of prematurity (ROP) is a painful procedure and pharmacological analgesia might be ineffective. We hypothesized that magnetic auricular acupuncture (MAA) compared to placebo will decrease pain during ROP exam in preterm infants. Methods: Multicentre randomized controlled trial conducted in three hospitals (Australia, Canada, and Malaysia). Eligibility: >32 weeks, ROP exam, not sedated, and parental consent. A total of 100 infants were randomized (1:1) to MAA (n = 50) or placebo (n = 50). MAA stickers or placebo were placed on both ears by an unblinded investigator. Pain was assessed using the Premature Infant Pain Profile. Primary analyses were by intention-to-treat. ClinicalTrials.gov:NCT03650621. Findings: The mean (standard deviation, SD) gestation, birthweight, and postnatal age were (MAA 28(3) vs. placebo 28(2) weeks; MAA 1,057(455) vs. placebo 952(273) g; MAA 7(3) vs. placebo 7(3) weeks. Placebo infants had significantly higher PIPP scores during [mean difference 1.6 points (95%CI 0.1-3.1)] and 1 h mean difference 1.5 points (95%CI 0.7-2.2) after the procedure (p < 0.03). Heart rate was lower (173(22) vs. 184(18)/min) and oxygen saturations were higher (93.8(6.2) vs. 91.7(6.1)%, p = 0.05) in MAA infants. No adverse effects. Interpretation: MAA may reduce physiological pain responses during and after ROP exam in preterm infants. Assessment of long-term effects are warranted. Clinical trial registration: www.ClinicalTrials.gov, identifier: NCT03650621.
    Matched MeSH terms: Reference Standards
  3. Quek YS, Ling MJN, Hassan JB
    Int J Surg Case Rep, 2020;73:235-238.
    PMID: 32721883 DOI: 10.1016/j.ijscr.2020.07.028
    INTRODUCTION: Diastasis recti abdominis (DRA) is characterized by the separation of the two rectus abdominis muscle along the linea alba. A newly modified undermined suture rectus muscle technique at cesarean delivery is created with improved post-operative outcome.

    PRESENTATION OF CASE: A 30-year-old woman, who had a previous cesarean delivery, opted for another cesarean section (CS) during this pregnancy. She claimed that her tummy was lax after her first experience of CS even with regular exercise. A standard CS procedure was carried out along with the new modified undermined suture technique for rectus muscle re-approximation. Post-operatively, the pain score was 2/10 without any evidence of hematoma, seromas or infection and the patient ambulates well. The patient did not complain of any pain or complications upon follow up after 2 weeks and 2 months post-operation. She claims that her abdomen is firmer, flatter and more stable compared to her previous operation experience.

    DISCUSSION: This newly modified method prevents any defect or weakness on the anterior abdominal wall even if the rectus muscles fail to oppose itself during the healing process. It also mimics the function of the linea alba and avoid interrupting the contraction or injuring the muscle in order to avoid pain. Adhesion of the anterior uterine wall and the rectus sheath can be prevented by closure of the rectus muscle and burying the suture material within the muscle.

    CONCLUSION: The newly modified undermined suture rectus muscle technique at cesarean delivery has the potential to improved patient's post-operative satisfaction.

    Matched MeSH terms: Reference Standards
  4. Arulappen AL, Danial M, Haron N, Hau LC, Khan AH
    Front Pharmacol, 2020;11:565818.
    PMID: 33664664 DOI: 10.3389/fphar.2020.565818
    Antimicrobial stewardship (AMS) program promotes the judicious use of antimicrobials. Hence, this study was conducted to analyze the impact of stewardship on the prescribing pattern of cefuroxime injection among the surgeons as perioperative antimicrobial prophylaxis (PAP). This study was conducted retrospectively in Malaysia. Various outcomes were measured including cefuroxime usage, compliance with the guidelines, surgical site infections, and cost savings. A total of 1,601 patients were recruited in the study. In terms of usage, the total defined daily dose (DDD) prior to the intervention was 202 DDD/100 procedures compared to that after intervention which was 144 DDD/100 procedures (p < 0.05). On the other hand, the excessively long administration of PAP dropped from 94.4 to 30.3% (p < 0.001). Focusing on the compliance with the newly developed local guidelines, it has increased from 53 to 94.3% after the interventions were made (p < 0.001), whereas the rate of surgical site infections was reduced from 17.0 to 9.0%. The cost of antibiotic being used has significantly reduced after the study intervention (p = 0.007). The quality of PAP directly impacts the antimicrobial usage, the surgical site infections, and the total cost involved. Thus, it is crucial to maintain the standard of PAP at all times in healthcare settings.
    Matched MeSH terms: Reference Standards
  5. Tengku Fazrina Tengku Mohd Arif, Farah Farhana Muhamad Hanafi, Nur Wardah Hanis Abdul Razak, Narissaporn Chaiprakit, Hazmyr Abdul Wahab
    ESTEEM Academic Journal, 2020;16(2):11-20.
    MyJurnal
    Anthropometric analysis provides the most reliable comparison of the body forms by using specific landmarks determined in respect of anatomical prominences. The knowledge of unique shape, anatomy and dimensions of the nose is very useful for surgeon undertaking its repair and reconstruction. Prosthetic rehabilitation also requires the ability to imagine the position and dimension of the nose within the facial proximity. Therefore, the access to nasal data for each
    population are advantageous. The aims were to measure parameters of external nose of a Malay population and to determine the significant difference in nose value parameters between gender and age group. The direct anthropometric measurements were carried out in 86 Malay subjects within the age range of 18 to 55 years old who attended UiTM dental clinic. Nasal landmarks were
    identified, and the nose parameters were measured using digital calliper. The values were expressed as mean, standard deviation and range. Nasal height, width and length of the nasal bridge were higher in male. The intercanthal width and philtrum length were statistically not significant for both genders. There were significant differences in nasal width, philtrum length, intercanthal width and outer intercommisural mouth width between the three age groups. However, the height of the nose, length of the nasal bridge and nasal index between age group were statistically not significant. The male population and the 41-55 years age group have higher nose value parameters. The most common type of nose was platyrrhine: broad. This study also suggested that Malay population have medium broad nose as the nasal index for both genders was ≤ 84.90.
    Matched MeSH terms: Reference Standards
  6. Muhammad Naim Mazani, Shuzlina Abdul-Rahman, Sofianita Mutalib
    ESTEEM Academic Journal, 2020;16(1):74-85.
    MyJurnal
    This study presents pre-processing methods for detecting lane detection using camera and Light Detection and Ranging (LiDAR) sensor technologies. Standard image processing methods are not suitable for complicated roads with various sign on the ground. Thus, determining the right techniques for pre-processing such data would be a challenge. The objectives of this study are to pre-process the scanned images and apply the image recognition algorithm for lane detection. The study employed Canny Edge Detection and Hough Transform algorithms on several sets of images. A different region of interest was experimented to find the optimal one. The experimental results showed that the proposed algorithms could be practical in terms of effectively detecting road lines and generate lane detection.
    Matched MeSH terms: Reference Standards
  7. Muhamad Imran Abdulah, Ikmal Abdul Hakim, Rosni Amin, Rosliza Parumo, Ma, Bee Chai, Noraziyah Abdul Aziz, et al.
    Q Bulletin, 2020;1(29):16-27.
    MyJurnal
    The Department of Oral & Maxillofacial Surgery at Hospital Sultanah Aminah, Johor Bahru started managing patients who lost their eyeballs with ocular prosthesis in 2013. Unfortunately, there was an increasing trend of failed ocular prosthesis from 2013-2015. The failure rate went from 28.6% in 2013 to 40% in 2014 and increased to 44.4% in 2015. Failed ocular prosthesis not only leads to dissatisfied patients but also an increase in cost due to redoing of prosthesis. The objective of this project was to reduce the incidence rate of failed ocular prosthesis. A failed case is when the prosthesis does not pass the issue stage and has to be redone from the beginning. The standard failure rate is 0%, as the average number of cases per year is only about 10 cases. We determined the contributing factors of failed ocular prosthesis by analysing retrospective data from patients’ dental and lab records. This was followed by a self-administered questionnaire on reasons for failed cases which was distributed among the dentists and lab technicians in our department. The contributing factors that were identified included insufficient knowledge or skill of dentist and lab technicians in the construction of the ocular prosthesis, as well as improper screening of new cases which was the main factor of all the failed cases. The strategies for change included improving the process of care by creating a checklist for proper screening of new patients, mentoring of new staff, and continuous training on construction of ocular prosthesis, Fabricated Iris Mould innovation technique and early referral for insertion of eye conformer. The interventions that were implemented reduced the failure rate to 20% in 2016 followed by 0% in 2017, 2018 and 2019. Ongoing efforts are being done to replicate this project in other Oral & Maxillofacial Surgery clinics in Johor.
    Matched MeSH terms: Reference Standards
  8. Lukman Nul Hakim Md Khairi, Farah Syakirah Ahmad, Aimi Shazana Muhammad Anuar, Nurul Ain Wan Omar, Nurul Najmi Muhammad, Nurulhayati Abd. Jamal, et al.
    Q Bulletin, 2020;1(29):28-35.
    MyJurnal
    Therapeutic drug monitoring (TDM) is a valuable clinical tool in optimisation of drug regimens. However, improper utilisation of TDM may lead to significant resource wastage and expose patients to avoidable trauma, toxicity, therapeutic failure and prolonged hospitalisation. This study aimed to reduce the percentage of inappropriate TDM sampling to our proposed standard of less than 20% within a four-month intervention period. A cross-sectional study was undertaken from January to December 2015 at the inpatient setting of Hospital Sultanah Nur Zahirah. Gentamicin and Vancomycin analytes were studied because these analytes accounted for 69.2% of total samples received in 2014. TDM Monitoring Form was used to collect sampling and dosage information to assess sampling appropriateness. A closed-ended self-administered questionnaire was distributed to a group of medical doctors to assess their knowledge on appropriate Gentamicin and Vancomycin TDM sampling method pre- and post-intervention. Prior to the intervention phase in October to December 2014, 79.4% of TDM were inappropriately sampled. The main contributing factors were inadequate knowledge among medical doctors, lack of sampling reminders for new TDM requests, and misunderstanding on sampling information for repeated TDM requests. 60-minute face-to-face educational sessions on TDM sampling method were conducted specifically for staff at the General Medical and Paediatric Departments, and two continuing medical education (CME) slots were held at the hospital level. Guidelines on TDM sampling was initiated and laminated copies were distributed to all wards. Implementation of TDM Alert System which consisted of digital reminders and physical stickers was also introduced. The interventions were able to reduce the inappropriate sampling percentage from 79.4% to 41.8% post-intervention, and to 19.1% in the recent monitoring phase of January until June 2019. Continuous close monitoring and sustainable implementation of the measures are vital as TDM sampling appropriateness may affect clinical interpretation of the results.
    Matched MeSH terms: Reference Standards
  9. Lukman Nul Hakim Md Khairi, Farah Syakirah Ahmad, Nur Liyana Mohd Fozi, Aimi Shazana Muhammad Anuar, Wan Najiah W. Mokhtar @ W. Moxtor, Maznuraini Zainuddin
    Q Bulletin, 2020;1(29):36-44.
    MyJurnal
    Bedside dispensing (BD) is one of the clinical services offered by the Pharmacy Department to patients prior to their hospital discharge. Increment in number of BD may improve the patients’ discharge process, patients’ satisfaction and their medication knowledge. This project aimed at increasing the percentage of BD in adult medical wards of Hospital Sultanah Nur Zahirah (HSNZ). The proposed standard of BD percentage was at least 30% within four months of intervention. The project was conducted from November 2016 to December 2019. The monthly report of pharmacy BD record was analysed to assess the achievement of BD. A pre-interventional retrospective BD data review of discharge prescriptions received throughout 2016 showed that only 8.1% of discharge prescriptions were dispensed at the bedside. A closed-ended questionnaire to evaluate knowledge, experience and perceived contributing factors to the low percentage of BD was distributed to nurses, inpatient pharmacists and ward pharmacists. The main contributing factors identified included time constraint, poor understanding of BD workflow, inadequate staff awareness and lack of cooperation among healthcare providers. Institutional BD workflow was implemented involving the introduction of discharge prescriptions pick-up points at medical wards, and a scheduled timing for prescriptions collection and dispensing during office hours. Three face-to-face educational sessions on overview of BD and its latest workflow were given to staff nurses, inpatient pharmacists at discharge pharmacy unit and ward pharmacists. In 2017, the percentage of BD increased from 8.1% to 28.0% after the implementation of interventions, and subsequently to 60.0% in the latest maintenance phase of January until December 2019. The sustainable implementation of this BD program could be shared and implemented at other facilities with inpatient discharge services to improve healthcare delivery.
    Matched MeSH terms: Reference Standards
  10. Nur Aliaa, Eusni Rahayu Mohd Tohit, Nik Hafidzah Nik Mustapha, Malina Osman
    MyJurnal
    Introduction: Increased monocyte percentage and monocyte anisocytosis were suggested as new markers for den- gue fever detection. This study aims to investigate and evaluate monocyte volume standard deviation (MoV-SD) and monocyte percentage (Mono %) parameters using Coulter automated haematology analyser as screening parameters in discriminating between dengue infection and other febrile illness. Methods: A cross-sectional laboratory analysis using suspected dengue fever patients were included in this study. The study was conducted in the Department of Pathology, Hospital Tuanku Jaafar Seremban from June 2016 until June 2017. Patients were classified into dengue positive and dengue negative based on dengue IgM and NS1 result. The diagnostic performance of MoV-SD and Mono % was analysed by receiver operating characteristic (ROC) curve analysis. The cut-off value of the MoV-SD and Mono % was determined and evaluated with the validation group. Chi-square test was used to assess the as- sociation between the parameters. Results: 88 (48.4%) from 182 samples were confirmed to have dengue infection. ROC curve analysis showed Mono % at cut off value of 10.5 % with area under the curve (AUC) of 0.869 with 84.1% sensitivity and 84% specificity (95% CI: 0.812-0.925) and MoV-SD cut off value at 22.2 (AUC 0.776, 80.7% sensitivity, 61.7% specificity, 95% CI: 0.709-0.843) are an excellent parameters in separating dengue positive and dengue-negative patients. A cut-off value of 10.5 of Mono % and 22.2 of MoV-SD were applied to the validation group showed 83.1%, 66.4% sensitivity and 84.9%, 77.3% specificity respectively. Conclusion: MoV-SD and Mono
    % parameters are a potential parameter for the screening of dengue infection in acute febrile illness patients with good specificity and sensitivity.
    Matched MeSH terms: Reference Standards
  11. Muhammad Danial Abu Hasan, Zair Asrar Ahmad, Mohd Salman Leong, Lim, Meng Hee
    MyJurnal
    The present paper deals with the novel approach for clustering using the image feature of stabilization diagram for automated operational modal analysis in parametric model which is stochastic subspace identification (SSI)-COV. The evolution of automated operational modal analysis (OMA) is not an easy task, since traditional methods of modal analysis require a large amount of intervention by an expert user. The stabilization diagram and clustering tools are introduced to autonomously distinguish physical poles from noise (spurious) poles which can neglect any user interaction. However, the existing clustering algorithms require at least one user-defined parameter, the maximum within-cluster distance between representations of the same physical mode from different system orders and the supplementary adaptive approaches have to be employed to optimize the selection of cluster validation criteria which will lead to high demanding computational effort. The developed image clustering process is based on the input image of the stabilization diagram that has been generated and displayed separately into a certain interval frequency. and standardized image features in MATLAB was applied to extract the image features of each generated image of stabilisation diagrams. Then, the generated image feature extraction of stabilization diagrams was used to plot image clustering diagram and fixed defined threshold was set for the physical modes classification. The application of image clustering has proven to provide a reliable output results which can effectively identify physical modes in stabilization diagrams using image feature extraction even for closely spaced modes without the need of any calibration or user-defined parameter at start up and any supplementary adaptive approach for cluster validation criteria.
    Matched MeSH terms: Reference Standards
  12. Safa’a Ahmad Al Masri, Siti Musliha Mat Rasid
    MyJurnal
    In the current study, a total of 86 soccer’s players with mean age of 14 years drawn from Terengganu soccer academy were tested in performing 10 parameters aiming at determining the performance of those players based on assessing the contribution of each activity and its corresponding significant level. The 10 performance related parameters involved anthropometry (BMI), fitness test (agility, coordination, muscular endurance (push and sit up), power, YoYo level), and football skill test (dribbling with ball, dribbling without ball and juggling). All the parameters testing is carried out based on international standard and performed by well-trained staff. The Pearson correlation analysis was used to achieve the objective in this study. Result shows a positive correlation between the two types of muscular parameters; the power is influenced by BMI and coordination; the specific football tests are highly impacted by the power and agility. The coefficient of determination R^2 and the significance level p-values show that the parameters that can be significantly considered are the anthropometric BMI (0.020), agility (0.025), muscular endurance (0.039 and 0.043), power (0.039), special football test without the ball (0.041), and juggling (0.046). The coordination, YoYo, football special test with the ball were not found to be significantly accounted for preparing the young players to achieve the required performance. Based on the results of the coefficient of determination and the significance p-values of the parameters, a model was proposed to determine the highest and lowest parameters that play important roles in the selection of young players.
    Matched MeSH terms: Reference Standards
  13. Sathasivam, Saratha, Mustafa Mamat, Mohd Shareduwan Mohd Kasihmuddin, Mohd. Asyraf Mansor
    MyJurnal
    Clonal selection algorithm and discrete Hopfield neural network are extensively employed for solving higher-order optimization problems ranging from the constraint satisfaction problem to complex pattern recognition. The modified clonal selection algorithm is a comprehensive and less iterative immune-inspired searching algorithm, utilized to search for the correct combination of instances for Very large-scale integrated (VLSI) circuit structure. In this research, the VLSI circuit framework consists of Boolean 3-Satisfiability instances with the different complexities and number of transistors are considered. Hence, a hybrid modified clonal selection algorithm with discrete Hopfield neural network is well developed to optimize the configuration of VLSI circuits with different number of electronic components such as transistors as the instances. Therefore, the performance of the developed hybrid model was assessed experimentally with the standard models, HNNVLSI-3SATES and HNNVLSI-3SATGA in term of circuit accuracy, sensitivity, robustness and runtime to complete the verification process. The results have demonstrated the developed model, HNNVLSI-3SATCSA produced a minimum error (consistently approaching 0), better accuracy (more than 80%) and faster computational time (less than 125 seconds) against changes in the complexity in term of the number of transistors. Furthermore, the developed hybrid model is able to minimize the computational burden and configurational noises for the variant of VLSI circuits.
    Matched MeSH terms: Reference Standards
  14. Mohd Rivaie, Fuziyah Ishak, Nur Idalisa, Nurul Hafawati Fadhilah
    MATEMATIKA, 2020;36(3):197-207.
    MyJurnal
    Conjugate Gradient (CG) methods have an important role in solving large
    scale unconstrained optimization problems. Nowadays, the Three-Term CG method has
    become a research trend of the CG methods. However, the existing Three-Term CG
    methods could only be used with the inexact line search. When the exact line search
    is applied, this Three-Term CG method will be reduced to the standard CG method.
    Hence in this paper, a new Three-Term CG method that could be used with the exact
    line search is proposed. This new Three-Term CG method satisfies the descent condition
    using the exact line search. Performance profile based on numerical results show that
    this proposed method outperforms the well-known classical CG method and some related
    hybrid methods. In addition, the proposed method is also robust in term of number of
    iterations and CPU time.
    Matched MeSH terms: Reference Standards
  15. Thuhairah Rahman, Radzi Ahmad, Suhaila Muid, Tengku Saifudin Tengku Ismail, Buravkova, Ludmila B., Hapizah Nawawi
    MyJurnal
    Inflammation and endothelial dysfunction are key components in atherogenesis. Should the status of these pro-atherogenesis factors be enhanced during prolonged confined space travel, specific countermeasures need to be instituted to prevent these processes to ensure safe outcome for astronauts during space expeditions. Six crew members were exposed to prolonged, confined isolation for 520 days. Standard exercise and diet regime were instituted throughout isolation phase. Age and gender-matched healthy, free living controls were recruited in parallel. Serial serum and whole blood were analysed for biomarkers of inflammation (hsCRP and IL-6) and endothelial activation (sICAM-1, sVCAM-1 and E-selectin). Flow-mediated dilatation (FMD) of the artery was performed following the standard protocols set by the International Brachial Artery Reactivity Task Force by trained personnel. There was decreased sVCAM-1 concentration in crew members compared to baseline. However, there was significant decrease in percentage dilatation from baseline in FMD of the brachial artery in the crew members. Percent change increment was observed in hsCRP while percent change reduction was seen in sVCAM-1. The enhanced inflammation and reduced endothelial function could possibly be attributed to the rigorous exercise instituted throughout the confinement period. Furthermore, possible haemoconcentration as a result of psychosocial stress and/ or exercise-induced physiological response could further explain elevations in hsCRP, and unlikely pathological. Furthermore, endothelial activation was attenuated during isolation, suggesting that the diet and exercise program instated throughout the period improved endothelial function.
    Matched MeSH terms: Reference Standards
  16. Ali AQ, Md Sultan AB, Abd Ghani AA, Zulzalil H
    PeerJ Comput Sci, 2020;6:e294.
    PMID: 33816945 DOI: 10.7717/peerj-cs.294
    Despite the benefits of standardization, the customization of Software as a Service (SaaS) application is also essential because of the many unique requirements of customers. This study, therefore, focuses on the development of a valid and reliable software customization model for SaaS quality that consists of (1) generic software customization types and a list of common practices for each customization type in the SaaS multi-tenant context, and (2) key quality attributes of SaaS applications associated with customization. The study was divided into three phases: the conceptualization of the model, analysis of its validity using SaaS academic-derived expertise, and evaluation of its reliability by submitting it to an internal consistency reliability test conducted by software-engineer researchers. The model was initially devised based on six customization approaches, 46 customization practices, and 13 quality attributes in the SaaS multi-tenant context. Subsequently, its content was validated over two rounds of testing after which one approach and 14 practices were removed and 20 practices were reformulated. The internal consistency reliability study was thereafter conducted by 34 software engineer researchers. All constructs of the content-validated model were found to be reliable in this study. The final version of the model consists of 6 constructs and 44 items. These six constructs and their associated items are as follows: (1) Configuration (eight items), (2) Composition (four items), (3) Extension (six items), 4) Integration (eight items), (5) Modification (five items), and (6) SaaS quality (13 items). The results of the study may contribute to enhancing the capability of empirically analyzing the impact of software customization on SaaS quality by benefiting from all resultant constructs and items.
    Matched MeSH terms: Reference Standards
  17. Rehman A, Hassan MF, Yew KH, Paputungan I, Tran DC
    PeerJ Comput Sci, 2020;6:e334.
    PMID: 33816982 DOI: 10.7717/peerj-cs.334
    In the near future, the Internet of Vehicles (IoV) is foreseen to become an inviolable part of smart cities. The integration of vehicular ad hoc networks (VANETs) into the IoV is being driven by the advent of the Internet of Things (IoT) and high-speed communication. However, both the technological and non-technical elements of IoV need to be standardized prior to deployment on the road. This study focuses on trust management (TM) in the IoV/VANETs/ITS (intelligent transport system). Trust has always been important in vehicular networks to ensure safety. A variety of techniques for TM and evaluation have been proposed over the years, yet few comprehensive studies that lay the foundation for the development of a "standard" for TM in IoV have been reported. The motivation behind this study is to examine all the TM models available for vehicular networks to bring together all the techniques from previous studies in this review. The study was carried out using a systematic method in which 31 papers out of 256 research publications were screened. An in-depth analysis of all the TM models was conducted and the strengths and weaknesses of each are highlighted. Considering that solutions based on AI are necessary to meet the requirements of a smart city, our second objective is to analyze the implications of incorporating an AI method based on "context awareness" in a vehicular network. It is evident from mobile ad hoc networks (MANETs) that there is potential for context awareness in ad hoc networks. The findings are expected to contribute significantly to the future formulation of IoVITS standards. In addition, gray areas and open questions for new research dimensions are highlighted.
    Matched MeSH terms: Reference Standards
  18. Muhammad Danial Abu Hasan, Zair Asrar Ahmad, Mohd Salman Leong, Lim, Meng Hee
    MyJurnal
    This paper presents parameters analysis for the estimated modal damping ratio using a new version of the automated enhanced frequency domain decomposition (AEFDD). The purpose of this study is to provide a better choice of a maximum number of points of time segments and modal assurance criterion (MAC) index number regarding to the variable level of system damping (low and high damped structure) and degree of freedom of the system. According current literature, frequency domain (FD) methods seem to have the problem with providing a correct identification of the modal damping ratio, since the correct estimate of modal damping is still an open problem and often leads to biased estimates. This technique is capable of providing consistent modal parameters estimation, particularly for modal frequencies and mode shapes. As a necessary fundamental condition, the algorithm has been assessed first from computed numerical responses according to random white noise, acting on different shear-type frame structures and corrupted with noise. Results indicate that reducing the value of natural frequencies and modal damping ratios of the modes under analysis demands longer time segments and a high value of the maximum number of points for adequate information on the decaying correlation functions when computing a modal damping ratio. In addition, the results also prove that the MAC index does not significantly affect the results for the low damped system. However, the use of a high MAC index value for the high damped system significantly introduces large error bound and it becomes worse, particularly for the higher modes, as the standard deviation of percentage error increases gradually. Furthermore, the use of a MAC index for a high number of points of time segments significantly increases the standard deviation of the percentage error.
    Matched MeSH terms: Reference Standards
  19. Mohd Shahrol Abd Wahil, Wong, Chin Mun, Abdullah Aliff Abdul Wahab, Hasni Ja’afar
    MyJurnal
    Malaysia is the world’s third largest exporter of liquified natural gas and the second largest oil and natural gas producer in Southeast Asia, following Indonesia. The potential air pollutants released from the industry may affect the health of the population. The primary objective of this study was to determine the potential health risk among the population in the zone of impact. This was a comparative case study between controlled and uncontrolled emissions based on the air dispersion modelling. Hazard quotient (HQ) was used to assess non-carcinogenic risk, while lifetime cancer risk (LCR) was used to assess carcinogenic risk. All ambient air pollutant levels were within permissible levels and adhered to the standard. The HQ for hydrogen sulphide and benzene was less than one in all scenarios. The LCR for benzene was acceptable in all scenarios. Advanced pollution prevention equipment should be installed within the gas emission system to treat the final emission to meet prescribed permissible limits. Continuous ambient air monitoring and effective control measures should be practiced to ensure the sustainability of clean air. The health risk assessment showed no risk of developing malignancy and non-cancer disorder among the workers and general population living surround the petrochemical plants. This allows the development of the petroleum refinery plants to be continued.
    Matched MeSH terms: Reference Standards
  20. Johdi NA, Sukor NF
    Front Immunol, 2020;11:1624.
    PMID: 33042104 DOI: 10.3389/fimmu.2020.01624
    Colorectal cancer is the third most common cancer in the world with increasing incidence and mortality rates globally. Standard treatments for colorectal cancer have always been surgery, chemotherapy and radiotherapy which may be used in combination to treat patients. However, these treatments have many side effects due to their non-specificity and cytotoxicity toward any cells including normal cells that are growing and dividing. Furthermore, many patients succumb to relapse even after a series of treatments. Thus, it is crucial to have more alternative and effective treatments to treat CRC patients. Immunotherapy is one of the new alternatives in cancer treatment. The strategy is to utilize patients' own immune systems in combating the cancer cells. Cancer immunotherapy overcomes the issue of specificity which is the major problem in chemotherapy and radiotherapy. The normal cells with no cancer antigens are not affected. The outcomes of some cancer immunotherapy have been astonishing in some cases, but some which rely on the status of patients' own immune systems are not. Those patients who responded well to cancer immunotherapy have a better prognostic and better quality of life.
    Matched MeSH terms: Reference Standards
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links