Displaying all 14 publications

Abstract:
Sort:
  1. Loke WP, Shukur MH, Yeap JK
    Med J Malaysia, 2006 Feb;61 Suppl A:40-4.
    PMID: 17042228
    Displaced humeral condyle fractures in children are traditionally fixed with smooth Kirschner wire at the expense of a risk of secondary displacement following removal of wire. Screw fixation of such fractures has recently been advocated as it provides stable fixation. We have been using screw osteosynthesis for treatment of displaced lateral humeral condyle fractures in children in our institution since the turn of this century. This study provides a midterm review of treatment of such injuries with special regards to growth disturbances after screw osteosynthesis and to assess rate of union with a view to formulate guidelines for screw removal. We review the outcomes of screw osteosynthesis for displaced lateral condyle fracture of the humerus (19 Milch type-1 and 15 Milch type-II) in 34 children treated in our institution from January 2000 to March 2004. The average age of the patients was 6.1 years. The average follow up was 24.5 months. Screw osteosynthesis led to union (average 6.9 weeks) in all patients with excellent results in 28 patients. Growth disturbances in the form of lateral condyle overgrowth (2 patients), valgus deformity secondary to lateral condyle avascular necrosis (2 patients) and fishtail deformity ((3 patients) were recognized. The implants should not be removed until fracture union is established. Screw osteosynthesis of the lateral humeral condyle fracture prevents secondary fracture redisplacement and lateral condyle overgrowth is probably related to hyperemic response to metaphyseal fixation and early removal of implant before radiological union.
  2. Pan KL, Shukur MH, Ghani MA
    Injury, 1994 Dec;25(10):655-7.
    PMID: 7829188
    Ten patients with complex non-union of the tibia were treated by locked intramedullary nailing. These patients had scarred skin as a result of initial severe open fractures, multiple debridement or fasciotomies with external fixators and skin grafts applied. Seven of the patients also had previous osteomyelitis or pin track infections. Fully pain-free walking was achieved in all patients and radiological union in nine patients without the need for a bone graft. Four patients developed infection after nailing, of which three resolved with treatment.
  3. Shukur MH, Noor MA, Moses T
    J Trauma, 1995 Jun;38(6):944-6.
    PMID: 7602642
    A severe form of an extremely unusual injury, ipsilateral fracture dislocation of the radial shaft head associated with elbow dislocation, is described. Radial shaft fracture was irreducible even after the radial head and the elbow were reduced. Open reduction and internal fixation are viable options.
  4. Ahmad S, Mahidon R, Shukur MH, Hamdan A, Kasmin M
    J Orthop Surg (Hong Kong), 2014 Dec;22(3):325-8.
    PMID: 25550011
    To evaluate the outcome of reconstruction for chronic grade-II posterior cruciate ligament (PCL) deficiency in Malaysian military personnel.
  5. Adnan A, Bajuri MY, Shukur MH, Subanesh S, Das S
    Clin Ter, 2014;165(1):41-5.
    PMID: 24589950 DOI: 10.7471/CT.2014.1660
    We report a case in a 62-year-old female who presented with a year history of dull aching pain of the left big toe, which was aggravated by pressure on the nail and relieved by analgesia. Tissue biopsy confirmed the diagnosis of malignant melanoma. There was a black colour swelling about 3x8 mm in size over the medial side of the dorsum of left big toe with a scar of previous operation. Histopathological examination showed on gross section of 2 blackish area one infiltrate the bone the other the tumour not infiltrate the proximal interphalangial joint with another satellite lesion 20mm from main tumour area was found. Malignant cells were large with abundant cytoplasm, hyperchromatic nuclei and some prominent eosinophilic nucleoli. Melanin pigment was markedly seen. The big toe was amputated. We here highlight a case where the patient was diagnosed and managed as having ingrown nail of the left big toe while in actual fact she had a subungual amelanotic melanoma.
  6. Radhi AM, Masbah O, Shukur MH, Shahril Y, Taiman K
    Med J Malaysia, 2006 Feb;61 Suppl A:50-2.
    PMID: 17042230
    Orthopaedic procedures especially dynamic hip screw (DHS) fixation, interlocking nailing (ILN) of the tibia and femur require fluoroscopic assistance. Frequent exposure to radiation is a major concern to members of the orthopaedic surgical team. This study was undertaken to measure shallow (skin) dose to the operating team personnel and deep (whole body) dose to the surgeon during such procedures in view to provide guidelines to the operating team members regarding the number of procedures allowable for them to perform or assist annually. Skin dose for the operating personnel and whole body dose for the operating surgeon during 25 procedures; ten cases of DHS, seven and six cases of ILN of the tibia and femur respectively, was measured using Thermoluminescent Dosimeter (TLD) chips. The shallow radiation dose for theatre personnel ranged from 0.19 mSy to 0.61 per case while the deep dose for the surgeon was 0.28, 0.55 and 0.81 mSy for seven cases of tibial ILN, ten cases of DHS and six cases of femur ILN respectively. The surgeon has the highest radiation exposure than other theatre personnel and the whole body exposure for DHS was higher than that of for ILN. However, the estimated cumulative dose was still far below the permissible annual dose limit.
  7. Roohi SA, Naicker AS, Shukur MH, Mohammad AR
    Med J Malaysia, 2006 Feb;61 Suppl A:30-5.
    PMID: 17042226
    The incidence of spinal injuries in Malaysia is on the rise following similar trend of rapid development and increasing number of building constructions sites, and motor vehicles. This epidemiological study was aimed at compiling local data with a view to identifying target areas for preventive measures as well as improvement strategies in the management of these potentially devastating injuries. Seventy eight patients admitted with spine trauma in 1998 in a level-one trauma centre were retrospectively reviewed. All records were traced from the admission and discharge books of the orthopaedic wards, accident and emergency wards, operative registration book, spinal rehabilitation ward and orthopaedic registration data of the Department of Orthopaedics, Hospital Kuala Lumpur. Details on pre-treatment neurological and radiological level of injury and post-treatment outcomes were recorded according to the American Spinal Injury Association (ASIA) impairment scale. Most patients (61.5%) were in the productive ages of less than 34 years with a 4:1 male to female ratio. Majority were due to motor vehicle accidents (57.7%) and fall from a height (28.3%). The thoraco-lumbar junction was the most common site of injury followed by the lower cervical region with 62.5% of which associated with neurological deficit. Neurological deficits: 11 ASIA-A, 1 ASIA-B, 6 ASIA-C, and 3 ASIA-D were detected in 21 (27%) patients with fall from height (50%) particularly landing on the feet (50%) and recreational sports (100%) were the risk factors. Less than 10% of patients were treated surgically and this explains an average 39.4 days of hospitalization (5 times longer in patients treated non-operatively). On discharge, four patients with incomplete neurology recovered to ASIA-E status and the remaining improved to ASIA-C and -D in one and five patients respectively. Only one patient with complete neurology improved to ASIA-B status following surgical treatment. The demographic profiles of our patients were comparable to other series in the literature but still inadequate to provide enough epidemiological data. A multicenter study to provide a larger pool of patients is needed.
  8. Aminudin CA, Suhail A, Shukur MH, Yeap JK
    Med J Malaysia, 2006 Feb;61 Suppl A:94-6.
    PMID: 17042240
    Acute traumatic transphyseal fracture of the capital femoral epiphysis is a rare but serious injury. The injury is typically inflicted by a severe trauma. Because of the vulnerability and predisposed anatomy of the femoral epiphysis in relation to its blood supply, the fracture has been designated to have poor prognosis with inevitable osteonecrosis and eventual deformity of the hip. We report a case of such fracture in a 13-year-old child in view to highlight some of the anticipated problems in the management of such injury.
  9. Samsudin O, Leong KK, Shukur MH, Tan KK, Ismail S
    Med J Malaysia, 2004 Dec;59 Suppl F:54-6.
    PMID: 15941164
    Pigmented villonodular synovitis (PVNS) is a distinct but rare clinical entity often presents late with a diagnostic difficulty. Its non-specific manifestations require exclusion of several chronic inflammatory disorders and other humorous lesions but all investigations including highly predictive magnetic resonance imaging (MRI) and arthroscopic examination are non-diagnostic demanding confirmatory tissue biopsy. A typical case of such lesion is presented to highlight some potential difficulties.
  10. Imma II, Nizlan NM, Ezamin AR, Yusoff S, Shukur MH
    Malays Orthop J, 2017 Jul;11(2):30-35.
    PMID: 29021876 MyJurnal DOI: 10.5704/MOJ.1707.012
    Introduction: The aims of this study are to define the coracoid process anatomy in a Malaysian population, carried out on patients in Hospital Serdang with specific emphasis on the dimension of the base of coracoid process which is important in coraco-acromial (CC) ligament reconstruction, to define the average amount of bone available for use in coracoid transfer, and to compare the size of coracoid process based on gender and race, and with findings in previous studies. Materials and Methods: Fifteen pairs of computed tomography (CT) based 3-dimensional models of shoulders of patients aged between 20 to 60 years old were examined. The mean dimensions of coracoid were measured and compared with regards to gender and race. The data were also compared to previously published studies. Results: The mean length of the coracoid process was 37.94 ± 4.30 mm. Male subjects were found to have larger-sized coracoids in all dimensions as compared to female subjects. The mean tip of coracoid dimension overall was 19.99 + 1.93mm length × 10.03 + 1.48mm height × 11.63 + 2.12mm width. The mean base of coracoid dimension was 18.96 + 3.71mm length × 13.84 + 1.76mm width. No significant differences were observed with regards to racial denomination. The overall coracoid size measurements were found to be smaller compared to previous studies done on the Western population. Conclusion: This study may suggest that Malaysians have smaller coracoid dimension compared to Caucasians. The findings further suggest that the incidence of coracoid fracture and implants pull out in Malaysian subjects may be higher.
  11. Mirzasadeghi A, Narayanan SS, Ng MH, Sanaei R, Cheng CH, Bajuri MY, et al.
    Biomed Mater Eng, 2014;24(6):2177-86.
    PMID: 25226916 DOI: 10.3233/BME-141029
    The application of bone substitutes and cements has a long standing history in augmenting fractures as a complement to routine fracture fixation techniques. Nevertheless, such use is almost always in conjunction with definite means of fracture fixation such as intramedullary pins or bone plates. The idea of using biomaterials as the primary fixation bears the possibility of simultaneous fixation and bone enhancement. Intramedullary recruitment of bone cements is suggested in this study to achieve this goal. However, as the method needs primary testings in animal models before human implementation, and since the degree of ambulation is not predictable in animals, this pilot study only evaluates the outcomes regarding the feasibility and safety of this method in the presence of primary bone fixators. A number of two sheep were used in this study. Tibial transverse osteotomies were performed in both animals followed by external skeletal fixation. The medullary canals, which have already been prepared by removing the marrow through proximal and distal drill holes, were then injected with calcium phosphate cement (CPC). The outcomes were evaluated postoperatively by standard survey radiographs, morphology, histology and biomechanical testings. Healing processes appeared uncomplicated until week four where one bone fracture recurred due to external fixator failure. The results showed 56% and 48% cortical thickening, compared to the opposite site, in the fracture site and proximal and distal diaphyses respectively. This bone augmentative effect resulted in 264% increase in bending strength of the fracture site and 148% increase of the same value in the adjacent areas of diaphyses. In conclusion, IMCO, using CPC in tibia of sheep, is safe and biocompatible with bone physiology and healing. It possibly can carry the osteopromotive effect of the CPCs to provide a sustained source of bone augmentation throughout the diaphysis. Although the results must be considered preliminary, this method has possible advantages over conventional methods of bone fixation at least in bones with compromised quality (i.e. osteoporosis and bone cysts), where rigid metal implants may jeopardize eggshell cortices.
  12. Ariffin HM, Mahdi NM, Rhani SA, Baharudin A, Shukur MH
    Strategies Trauma Limb Reconstr, 2011 Apr;6(1):21-6.
    PMID: 21589678 DOI: 10.1007/s11751-011-0105-4
    High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of motion and correction of any mal-alignment. With this technique, soft tissue complications particularly surgical site infections are expected to be significantly reduced. This prospective study aims to determine the effectiveness of a modified hybrid external fixator in the management of high-energy tibial plateau fractures. Thirty-three patients with high-energy Schatzker V and VI tibial plateau fracture with severe soft tissue injury precluding formal open reduction were enrolled into the study. The fixator was a construct combining the Ilizarov ring with a monolateral external fixator. The results-bony union, range of motion, and associated complications of the treatment-were assessed. All fractures united within an average time of 14 weeks. Neither loss of reduction nor surgical site wound breakdown/osteomyelitis was noted. Eight patients developed superficial pin track infection and one septic arthritis of the knee joint. Hybrid external fixation is a safe option for complex high-energy tibial plateau fractures by simultaneously providing adequate fracture stabilization and protection of soft tissue healing to achieve bony union. The complication is mainly related to pin tract infection.
  13. Diong TW, Haflah NHM, Kassim AYM, Habshi SMIA, Shukur MH
    J Hand Surg Asian Pac Vol, 2018 Mar;23(1):26-32.
    PMID: 29409409 DOI: 10.1142/S2424835518500030
    BACKGROUND: The use of volar locking plate in distal radius fracture can lead to extensor tendon rupture due to dorsal screw penetration. The aim of our study was to investigate the occurrence of dorsal and intra-articular screw penetration using CT scan after volar distal radius osteosynthesis for distal radius fractures.

    METHODS: Thirty patients who underwent distal volar locking plate for distal radius fracture were included in a retrospective study. In all 30 patients no dorsal and intra-articular screw penetration were detected on standard AP and lateral views of a plain radiograph. CT scan of the operated wrist was performed to determine the number of intra-articular and dorsal screw penetrations. Clinical examination was performed to determine the wrist functions in comparison to the normal wrist.

    RESULTS: Nineteen wrists were noted to have screw penetration either dorsally or intraarticularly. The highest incidence is in the 2nd extensor compartment where 13 screws had penetrated with a mean of 2.46 mm. Six screws penetrated into the distal radial ulnar joint and five screws into the wrist joint with a mean of 2.83 mm and 2.6 mm, respectively. However, there was no incidence of tendon irritation or rupture.

    CONCLUSIONS: This study demonstrated a high incidence of dorsal and intra-articular screw penetration detected by CT scan which was not apparent in plain radiograph. We recommend that surgeons adhere to the principle of only near cortex fixation and downsizing the locking screw length by 2 mm.