Displaying all 9 publications

Abstract:
Sort:
  1. Yap SP, Yuen KH
    Int J Pharm, 2004 Aug 20;281(1-2):67-78.
    PMID: 15288344
    A single dose comparative bioavailability study was conducted to evaluate the bioavailability of tocotrienols from two self-emulsifying formulations, one of which produced an emulsion that readily lipolysed under in vitro condition (SES-A), while the other produced a finer dispersion with negligible lipolysis (SES-B) in comparison with that of a non-self-emulsifying formulation in soya oil. The study was conducted according to a three-way crossover design using six healthy human volunteers. Statistically significant differences were observed between the logarithmic transformed peak plasma concentration (Cmax) and total area under the plasma concentration-time curve (AUC(0-infinity)) values of both SES-A and -B compared to NSES-C indicating that SES-A and -B achieved a higher extent of absorption compared to NSES-C. Moreover, the 90% confidence interval of the AUC(0-infinity) values of both SES-A and -B over those of NSES-C were between 2-3 suggesting an increase in bioavailability of about two-three times compared to NSES-C. Both SES-A and -B also achieved a faster onset of absorption. However, both SES-A and -B had comparable bioavailability, despite the fact that SES-B was able to form emulsions with smaller droplet size. Thus, it appeared that both droplet sizes as well as the rate and extent of lipolysis of the emulsion products formed were important for enhancing the bioavailability of the tocotrienols from the self-emulsifying systems.
  2. Yap SP, Yuen KH, Lim AB
    J Pharm Pharmacol, 2003 Jan;55(1):53-8.
    PMID: 12625867
    A study was conducted to evaluate the bioavailability of alpha-, gamma- and delta-tocotrienols administered via oral, intravenous, intramuscular and intraperitoneal routes in rats. Three separate experiments, each conducted according to a two-way crossover design, were carried out to compare intravenous and oral, intramuscular and oral, and intraperitoneal and oral administration. Oral absorption of all three tocotrienols was found to be incomplete. Of the three tocotrienols, alpha-tocotrienol had the highest oral bioavailability, at about 27.7+/-9.2%, compared with gamma- and delta-tocotrienols, which had values of 9.1+/-2.4% and 8.5+/-3.5%, respectively. Such biodiscrimination was also observed in their total clearance rates (estimated from the intravenous data). alpha-Tocotrienol showed the lowest clearance rate at about 0.16 L kg(-1) h(-1), whereas that of delta- and gamma-tocotrienols was quite similar, with values of 0.24 and 0.23 L kg(-1) h(-1), respectively. Interestingly, all three tocotrienols were found to be negligibly absorbed when administered intraperitoneally and intramuscularly. Thus, these two routes of administration should be avoided when evaluating the biological activities of the tocotrienols in whole animal experiments.
  3. Yap SP, Yuen KH, Wong JW
    J Pharm Pharmacol, 2001 Jan;53(1):67-71.
    PMID: 11206194
    We have investigated the pharmacokinetics and bioavailability of alpha-, gamma- and delta-tocotrienols under fed and fasted conditions in eight healthy volunteers. The volunteers were administered a single oral dose of mixed tocotrienols (300 mg) under fed or fasted conditions. The bioavailability of tocotrienols under the two conditions was compared using the parameters peak plasma concentration (Cmax), time to reach peak plasma concentration (Tmax) and total area under the plasma concentration-time curve (AUC(o-infinity)). A statistically significant difference was observed between the fed and fasted logarithmic transformed values of Cmax (P < 0.01) and AUC(0-infinity) (P < 0.01) for all three tocotrienols. In addition, the 90% confidence intervals for the ratio of the logarithmic transformed AUC(0-infinity) values of alpha-, gamma- and delta-tocotrienols under the fed state over those of the fasted state were found to lie between 2.24-3.40, 2.05-4.09 and 1.59-3.81, respectively, while those of the Cmax were between 2.28-4.39, 2.31-5.87 and 1.52-4.05, respectively. However, no statistically significant difference was observed between the fed and fasted Tmax values of the three homologues. The mean apparent elimination half-life (t(1/2)) of alpha-, gamma- and delta-tocotrienols was estimated to be 4.4, 4.3 and 2.3 h, respectively, being between 4.5- to 8.7-fold shorter than that reported for alpha-tocopherol. No statistically significant difference was observed between the fed and fasted t(1/2) values. The mean apparent volume of distribution (Vd/f) values under the fed state were significantly smaller than those of the fasted state, which could be attributed to increased absorption of the tocotrienols in the fed state.
  4. Yuen KH, Wong JW, Yap SP, Billa N
    Int J Clin Pharmacol Ther, 2001 Jan;39(1):37-40.
    PMID: 11204936
    OBJECTIVE: The aim of the present communication is to provide information regarding the intrasubject coefficent of variation obtained from 30 bioequivalence studies covering 16 drugs which can be used for estimation of sample size. Additionally, an attempt was also made to estimate the test power of each of the studies conducted.

    METHODS: The intrasubject coefficient of variation was estimated from the residual mean square error obtained from analysis of variance of the parameters AUC0-infinity, Cmax and Cmax/AUC0-infinity after logarithmic transformation. The test power in the analyses of the above parameters was subsequently estimated using nomograms provided by Diletti et al. [1991].

    RESULTS AND CONCLUSION: Thirty products covering 16 drugs were studied in which 22 were immediate-release (including one dispersible tablet) and 8 were sustained-release formulations. The intrasubject coefficient of variation for the parameter AUC0-infinity was smaller than Cmax, and hence considerably more studies were able to attain a power of greater than 80% using 12 volunteers for the AUC0-infinity, compared to the Cmax. However, the variability in the Cmax could be reduced by using the parameter Cmax/ AUC0-infinity, and thus, provide a more realistic estimation of sample size, since the latter reflects only the rate of absorption and not both the rate and extent as in the case of Cmax [Endrenyi et al. 1991].

  5. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
  6. Loganathan L, Yap SP, Lau BF, Nagapan M
    Environ Sci Pollut Res Int, 2023 Jun;30(26):69176-69191.
    PMID: 37133663 DOI: 10.1007/s11356-023-27256-y
    Replacing conventional fine aggregates with spent mushroom substrate (SMS) is aimed at developing a sustainable lightweight masonry mortar. It is also an alternative solution for the current improper mushroom waste disposals. Density, workability, compressive strength, specific strength, flexural strength, ultrasonic pulse velocity, water absorption, sorptivity, and equivalent CO2 emission in relation to sand reduction in mortars containing 2.5-15.0% (by volume) SMS passing through a 4.75-mm sieve were investigated. As the percentages of replacement increased from 2.5 to 15.0%, the density of the SMS mortar reduced up to 34.8%, with corresponding compressive strengths of 24.96 to 3.37 MPa. Mixes with up to 12.5% SMS met the minimum compressive and flexural strengths as stated in the ASTM C129 standard. In addition, the equivalent CO2 emission of the mixes reduced 15.09% as the SMS content increased while cost-effectiveness increases up to 98.15% until 7.5% SMS replacement. In conclusion, the use of SMS as fine aggregates up to 12.5% is a viable mix design strategy for producing sustainable lightweight mortar with a lower carbon emission.
  7. Loon YH, Wong JW, Yap SP, Yuen KH
    PMID: 15664346
    A simple liquid chromatographic method was developed for the simultaneous determination of flavonoids from Orthosiphon stamineus Benth, namely sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, in plasma. Prior to analysis, the flavonoids and the internal standard (naproxen) were extracted from plasma samples using a 1:1 mixture of ethyl acetate and chloroform. The detection and quantification limits for the three flavonoids were similar being 3 and 5 ng/ml, respectively. The within-day and between-day accuracy values, expressed as percentage of true values, for the three flavonoids were between 95 and 107%, while the corresponding precision, expressed as coefficients of variation, for the three flavonoids were less than 14%. In addition, the mean recovery values of the extraction procedure for all the flavonoids were between 92 and 114%. The calibration curves were linear over a concentration range of 5-4000 ng/ml. The present method was applied to analyse plasma samples obtained from a pilot study using rats in which the mean absolute oral bioavailability values for sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone was 9.4, 1.0 and 1.5%, respectively.
  8. Yuen KH, Choy WP, Tan HY, Wong JW, Yap SP
    J Pharm Biomed Anal, 2001 Feb;24(4):715-9.
    PMID: 11272330
    A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
  9. Khan S, Yap SP, Tan CG, Ganasan R, Sherif MM, El-Shafie A
    Materials (Basel), 2021 Sep 20;14(18).
    PMID: 34576670 DOI: 10.3390/ma14185446
    Palm oil clinker (POC) aggregates is a viable alternative to the naturally occurring sand and gravel in the manufacturing of concrete. The usage of POC aggregates assists in the reduction of solid waste and preserves the consumption of natural resources. Although researchers investigated the mechanical response of POC-containing concrete, limited research is available for its torsional behavior. In general, the torsional strength depends on the tensile strength of concrete. This research investigates the compressive, tensile, and torsional response of concrete with various ratios of POC-aggregates. Five batches of concrete were casted with POC-aggregate replacing granite at ratios of 0, 20, 40, 60, and 100%. The selection for the mixture proportions for the various batches was based on the design of experiments (DOE) methodology. The hard density, compressive strength, splitting tensile strength, and flexural strength of concrete with a 100% replacement of granite with POC-aggregates reduced by 8.80, 37.25, 30.94, and 14.31%, respectively. Furthermore, a reduction in initial and ultimate torque was observed. While cracks increased with the increase in POC-aggregates. Finally, the cracking of concrete subjected to torsional loads was monitored and characterized by acoustic emissions (AE). The results illustrate a sudden rise in AE activities during the initiation of cracks and as the ultimate cracks were developed. This was accompanied by a sudden drop in the torque/twist curve.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links