Methods: This was a prospective cohort study involving newly diagnosed PDR patients. All patients underwent specular microscopy examination (CCT, ECD and endothelial cell area CoV) both pre-PRP and at 1-week and 6-weeks after the final PRP session (post-PRP). A Carl Zeiss Visulas Argon laser (532 nm) was used to perform PRP.
Results: A total of 33 newly diagnosed PDR patients were included in this study. There were no significant differences in mean CCT, ECD, and endothelial cell area CoV at 1-week and 6-weeks following PRP compared to pre-treatment baseline (p > 0.05). Further, there were no significant correlations between laser energy delivered and CCT, ECD and endothelial cell area CoV at either post-PRP examination time.
Conclusion: Argon laser (523 nm) energy delivered within recommended ranges for PRP had no adverse effects on corneal structure.
METHODS: A cross-sectional study was conducted in Hospital Universiti Sains Malaysia, Kelantan from November 2013 till May 2016 among Type 2 DM patients (DM with no DR and DM with NPDR). The patients were evaluated for anterior ocular segment biometry [central corneal thickness (CCT), anterior chamber width (ACW), angle opening distance (AOD) and anterior chamber angle (ACA)] by using Anterior Segment Optical Coherence Tomography (AS-OCT). Three ml venous blood was taken for the measurement of HbA1c.
RESULTS: A total of 150 patients were included in this study (DM with no DR: 50 patients, DM with NPDR: 50 patients, non DM: 50 patients as a control group). The mean CCT and ACW showed significant difference among the three groups (p < 0.001 and p = 0.015 respectively). Based on post hoc result, there were significant mean difference of CCT between non DM and DM with NPDR (mean difference 36.14 μm, p < 0.001) and also between non DM and DM with no DR (mean difference 31.48 μm, p = 0.003). The ACW was significantly narrower in DM with NPDR (11.39 mm SD 0.62) compared to DM with no DR (11.76 mm SD 0.53) (p = 0.012). There were no significant correlation between HbA1c and all the anterior ocular segment biometry.
CONCLUSION: Diabetic patients have significantly thicker CCT regardless of retinopathy status whereas ACW was significantly narrower in DM with NPDR group compared to DM with no DR. There was no significant correlations between HbA1c and all anterior ocular segment biometry in diabetic patients regardless of DR status.
METHODS: This comparative pilot study consists of 40 diabetic patients with diabetic macular oedema. The patients were randomized into two groups using envelope technique sampling procedure. Treatment for diabetic macular oedema was based on the printed envelope technique selected for every patient. Twenty patients were assigned for IVTA group (one injection of IVTA) and another 20 patients for LASER group (one laser session). Main outcome measures were mean BCVA and mean MEI at three months post treatment. The MEI was quantified using Heidelberg Retinal Tomography II.
RESULTS: The mean difference for BCVA at baseline [IVTA: 0.935 (0.223), LASER: 0.795 (0.315)] and at three months post treatment [IVTA: 0.405 (0.224), LASER: 0.525 (0.289)] between IVTA and LASER group was not statistically significant (p = 0.113 and p = 0.151 respectively). The mean difference for MEI at baseline [IVTA: 2.539 (0.914), LASER: 2.139 (0.577)] and at three months post treatment [IVTA: 1.753 (0.614), LASER: 1.711 (0.472)] between IVTA and LASER group was also not statistically significant (p = 0.106 and p = 0.811 respectively).
CONCLUSIONS: IVTA demonstrates good outcome comparable to laser photocoagulation as a primary treatment for diabetic macular oedema at three months post treatment.
TRIAL REGISTRATION: ISRCTN05040192 (http://www.controlled-trial.com).