Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Patil PG, Nimbalkar-Patil S
    Contemp Clin Dent, 2015 Jul-Sep;6(3):318-20.
    PMID: 26321828 DOI: 10.4103/0976-237X.161869
    Recording of the maxillomandibular relationship (MMR) in implant complete arch restorations usually necessitates removal of the healing abutments to attach the record bases, which makes the procedures tedious and time-consuming.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  2. Abdelrehim A, Etajuri EA, Sulaiman E, Sofian H, Salleh NM
    J Prosthet Dent, 2024 Sep;132(3):528-535.
    PMID: 36357194 DOI: 10.1016/j.prosdent.2022.09.010
    STATEMENT OF PROBLEM: Attaining a passive fit in implant restorations is desirable but clinically difficult to achieve, especially in screw-retained prostheses. At a certain magnitude, this misfit will not cause mechanical and biological complications, but the exact level has yet to be determined.

    PURPOSE: The purpose of this systematic review was to gather, compare, and appraise studies that attempted to determine the biological and mechanical tolerance of misfits.

    MATERIAL AND METHODS: The review protocol was published in the Prospective Register for Systematic Reviews (PROSPERO; registration no. CRD42021268399) and follows the Preferred Reporting for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. An electronic search was conducted through PubMed, Ebscohost, and Web of Science followed by a manual search up to December 2021.

    RESULTS: A total of 413 manuscripts were identified by electronic and manual search. After removing duplicates, nonrelevant titles, and abstract screening, 62 manuscripts were eligible for full-text assessment. Finally, a total of 13 articles (1 cross-sectional study, 1 retrospective and prospective, 7 in vitro studies, and 4 animal studies) met the eligibility criteria and were included in this review. A wide range of tolerable misfits were reported. Vertical misfit up to 1 mm and horizontal misfit up to 345 μm were associated with no adverse outcomes.

    CONCLUSIONS: The current literature provides inadequate data to determine a clinical threshold of an acceptable misfit. However, this review demonstrated that the mechanical response to misfit is more critical than the biological response.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  3. Khuder T, Yunus N, Sulaiman E, Dabbagh A
    J Mech Behav Biomed Mater, 2017 11;75:97-104.
    PMID: 28709037 DOI: 10.1016/j.jmbbm.2017.06.039
    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  4. Kamar Affendi NH, Ahmad R, Tong Wah L, Abdul Hamid NF, Abdul Hakim AY
    Dent Med Probl, 2024;61(2):257-268.
    PMID: 38686968 DOI: 10.17219/dmp/155811
    BACKGROUND: The screw-retrievable cement-retained (SRCR) design combines the benefits of both screwand cement-retained implant-supported restorations. This concept has sparked interest in implant dentistry. However, there is a lack of research on fracture behaviors and clinical performance of such restorations.

    OBJECTIVES: The aim of the present article was to review the current literature on the fracture loads and fracture modes of SRCR implant restorations - in vitro studies, and also studies demonstrating the clinical performance of such design.

    MATERIAL AND METHODS: A literature search was conducted from January 2000 to June 2022, using 6 databases to identify studies on fracture load and clinical performance that fulfilled the eligibility criteria. Thirty-eight studies met the inclusion criteria (22 in vitro and16 in vivo). The in vivo studies comprised case reports/series/letters (9), clinical techniques (2), retrospective/prospective studies (3), and randomized controlled trials (RCTs) (2).

    RESULTS: The reviewed articles reported the effects of the SRCR design on the fracture risk if screw access channels were filled or unfilled, with regard to their diameter, and the preparation before or after glazing. The effect of the type of material used in the construction on the fracture modes SRCR restorations was also reported. The long-term clinical data was mainly retrospective and referred to metal-ceramic constructions. Limited long-term clinical data was available for all-ceramic materials and high-performance polymers (HPPs).

    CONCLUSIONS: Screw-retrievable cement-retained implant restorations appear to have potential in the monolithic design. If the SRCR construction is metal-ceramic or made of a veneered material, special design and abutment selection should be considered. High-performance polymers may be recommended as a substitute for posterior implant restoration.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  5. Mahat NS, Shetty NY, Kohli S, Jamayet NB, Patil P
    Evid Based Dent, 2023 Sep;24(3):142.
    PMID: 37369705 DOI: 10.1038/s41432-023-00904-5
    OBJECTIVE: To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.

    MATERIALS AND METHODS: The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.

    RESULTS: A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).

    CONCLUSION: Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  6. Zhong J, Guazzato M, Chen J, Zhang Z, Sun G, Huo X, et al.
    J Mech Behav Biomed Mater, 2020 02;102:103490.
    PMID: 31877512 DOI: 10.1016/j.jmbbm.2019.103490
    Mechanical failure of zirconia-based full-arch implant-supported fixed dental prostheses (FAFDPs) remains a critical issue in prosthetic dentistry. The option of full-arch implant treatment and the biomechanical behaviour within a sophisticated screw-retained prosthetic structure have stimulated considerable interest in fundamental and clinical research. This study aimed to analyse the biomechanical responses of zirconia-based FAFDPs with different implant configurations (numbers and distributions), thereby predicting the possible failure sites and the optimum configuration from biomechanical aspect by using finite element method (FEM). Five 3D finite element (FE) models were constructed with patient-specific heterogeneous material properties of mandibular bone. The results were reported using volume-averaged von-Mises stresses (σVMVA) to eliminate numerical singularities. It was found that wider placement of multi-unit copings was preferred as it reduces the cantilever effect on denture. Within the limited areas of implant insertion, the adoption of angled multi-unit abutments allowed the insertion of oblique implants in the bone and wider distribution of the multi-unit copings in the prosthesis, leading to lower stress concentration on both mandibular bone and prosthetic components. Increasing the number of supporting implants in a FAFDPs reduced loading on each implant, although it may not necessarily reduce the stress concentration in the most posterior locations significantly. Overall, the 6-implant configuration was a preferable configuration as it provided the most balanced mechanical performance in this patient-specific case.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  7. Siar CH, Pua CK, Toh CG, Romanos G, Ng KH
    Oral Surg Oral Med Oral Pathol Oral Radiol, 2012 Nov;114(5 Suppl):S46-53.
    PMID: 23083955 DOI: 10.1016/j.tripleo.2011.07.049
    The objective of this study was to investigate the cementum status in natural teeth opposing implant-supported bridgework.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/adverse effects*
  8. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH
    Eur J Prosthodont Restor Dent, 2012 Mar;20(1):35-9.
    PMID: 22474935
    This paper aims to evaluate the effect of splinting during implant impression. A master model with two fixtures at the sites of 45 and 47 was used. 20 impressions were made for all four techniques: (A) indirect; (B) direct, unsplinted; (C) direct, splinted; and (D) direct, splinted, sectioned, and re-splinted. Splinting was undertaken with autopolymerizing acrylic resin (AAR). Horizontal distance between fixtures was compared using a digital caliper. The difference in distance were analysed with one-way ANOVA. Group A showed a significantly lowest accuracy among all techniques (p < or = 0.05). There was no significant difference of accuracy among the groups using direct techniques (p > or = 0.05). Group D was more accurate compared to group B and C. We conclude that splinting of impression copings would be beneficial to obtain an accurate impression.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  9. Rajan G, Baig MR, Nesan J, Subramanian J
    Indian J Dent Res, 2010 Jan-Mar;21(1):125-8.
    PMID: 20427922 DOI: 10.4103/0970-9290.62801
    Treatment of patients with aggressive periodontitis has always been a challenge to the clinician. Both young and old are known to be affected by this progressive destructive condition of the supporting dental structures. Although dental implants have been offered as a viable treatment alternative for such patients, additional procedures (like bone grafting) and delayed protocols have limited their usage. This case report describes the treatment of a young patient with aggressive periodontitis using a graftless implant solution. Zygoma implants in conjunction with conventional implants were used with immediate loading.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  10. Taiyeb-Ali TB, Toh CG, Siar CH, Seiz D, Ong ST
    Implant Dent, 2009 Oct;18(5):438-46.
    PMID: 22129962 DOI: 10.1097/ID.0b013e3181ad8e7a
    To compare the clinical soft tissue responses around implant tooth-supported 3-unit bridges using tapered abutments with those using butt-joint abutments.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  11. Rahman RA, Ngeow WC, Chai WL, Ramli R
    Singapore Dent J, 2006 Dec;28(1):7-10.
    PMID: 17378335
    Head and neck cancer is becoming a more recognizable pathology to the general population and dentists. The modes of treatment include surgery and/or radiation therapy. Pretreatment dental assessment should be provided for these patients before they undergo radiation therapy. There are occasions, however, whereby head and neck cancer patients are not prepared optimally and, as a result, they succumb to complicated oral adverse effects after radiation therapy. The management of radiation-induced caries, a sequelae of xerostomia has been reviewed in Part II of this series. In this article, the management of difficulty with dentures, another sequelae of xerostomia following radiation therapy is reviewed.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/methods*
  12. Shankargouda SB, Sidhu P, Kardalkar S, Desai PM
    J Prosthodont, 2017 Feb;26(2):168-171.
    PMID: 26479878 DOI: 10.1111/jopr.12385
    Residual ridge resorption is a rapid, progressive, irreversible, and inevitable process of bone resorption. Long-standing teeth and implants have been shown to have maintained the bone around them without resorption. Thus, overdenture therapy has been proven to be beneficial in situations where few remaining teeth are present. In addition to the various advantages seen with tooth-supported telescopic overdentures, a few shortcomings can also be expected, including unseating of the overdenture, increased bulk of the prosthesis, secondary caries, etc. The precise transfer of the secondary telescopic copings to maintain the spatial relationship, without any micromovement, remains the most critical step in ensuring the success of the tooth-supported telescopic prosthesis. Thus, a simple and innovative technique of splinting the secondary copings was devised to prevent distortion and micromovement and maintain its spatial relationship.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported/methods*
  13. Patil PG, Seow LL
    J Prosthet Dent, 2020 May;123(5):710-716.
    PMID: 31558274 DOI: 10.1016/j.prosdent.2019.07.015
    STATEMENT OF PROBLEM: Single-implant-retained overdentures are an alternative treatment option for an edentulous mandible. However, evaluation of their clinical performance with an immediate loading protocol is lacking.

    PURPOSE: The purpose of this prospective randomized controlled clinical study was to evaluate crest bone-level changes and patient satisfaction with mandibular overdentures retained by 1 or 2 titanium-zirconium (Ti-Zr) implants with immediate loading protocols after 1 year.

    MATERIAL AND METHODS: Thirty-six Ti-Zr implants were placed in 24 participants (single central implant in 12 participants and 2 interforaminal implants in 11 participants) by a single operator. LOCATOR attachments were used to retain the mandibular overdentures with an immediate loading protocol, and observations were made at 1 month and 1 year. Changes to the crestal bone level were evaluated with digital periapical radiographs. A 100-mm visual analog scale (VAS) was used to evaluate patient satisfaction. The Mann-Whitney U test was used to analyze the data.

    RESULTS: At 1 month, the mean crestal bone loss was 0.23 mm in the 2-implant group (n=22) and 0.39 mm (P=.181) in the single-implant group (n=11). At 1 year, the bone loss was 0.67 mm in the 2-implant group and 0.88 mm (P=.248) in the single-implant group. The mean VAS score for patient satisfaction level increased from 38.3% to 49.7% for single-implant participants and from 40.5% to 54.8% for 2-implant participants 1 month after implant placement (P=.250) and from 38.3% to 54.5% for single-implant participants and from 40.5% to 58.9% for 2-implant participants after 1 year (P=.341).

    CONCLUSIONS: Single-implant-retained mandibular overdentures with an immediate loading protocol may represent a viable treatment option considering crestal bone-level changes and patient satisfaction compared with 2-implant-retained mandibular overdentures after 1 year of follow-up.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  14. Alsrouji MS, Ahmad R, Abdul Razak NH, Shuib S, Kuntjoro W, Baba NZ
    J Prosthodont, 2019 Feb;28(2):e764-e770.
    PMID: 30044033 DOI: 10.1111/jopr.12954
    PURPOSE: To relate the principal stress, strain, and total deformation in the premaxilla region beneath a complete denture to the pattern of premaxilla bone resorption when opposed by a conventional complete denture (CD) or by a two-implant-retained overdenture (IOD) using finite element analysis (FEA).

    MATERIALS AND METHODS: Three-dimensional solid models of the maxilla, mucosa, and denture of a selected edentulous patient were created using Mimics and CATIA software. The FEA model was created and duplicated in ANSYS 16.0 to perform two simulations for the IOD and the CD models. The values of maximum stress and strain and total deformation were obtained and compared to the outcomes of premaxilla resorption from a parallel clinical study.

    RESULTS: The maximum principal stress in the premaxilla in the IOD model ranged from 0.019 to 0.336 MPa, while it ranged from 0.011 to 0.193 MPa in the CD model. The maximum principal strain in the IOD model was 1.75 times greater than that in the CD model. Total deformation was 1.8 times higher in the IOD model. Greater bone resorption was observed in regions of higher stress, which were on the occlusal and buccal sides of the premaxilla residual ridge.

    CONCLUSION: Stress, strain, and total deformation values present in the premaxilla area beneath a CD were approximately two times greater in a comparison between an opposing mandibular two-IOD and an opposing mandibular CD. The results were consistent with a parallel clinical study in which the rate of premaxilla bone resorption was almost three times greater in the IOD group.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported/adverse effects*
  15. Alsrouji MS, Ahmad R, Rajali A, Mustafa NWNA, Ibrahim N, Baba NZ
    J Prosthodont, 2019 Feb;28(2):131-137.
    PMID: 30427557 DOI: 10.1111/jopr.12999
    PURPOSE: To compare the residual ridge resorption (RRR) of the anterior maxillary bone beneath complete dentures when opposed by mandibular complete dentures (CD) and implant-retained overdentures (IRO).

    MATERIALS AND METHODS: 18 patients were rehabilitated with maxillary CD opposing mandibular IRO, and 4 patients were prescribed with conventional CD. Cone beam computed tomography (CBCT) scans of the maxilla were acquired before and 1 year post-treatment and converted into 3D models using Mimics research software. RRR was quantified by measuring the changes in bone volume following superimpositioning and sectioning of these models at the anterior maxillary region. Subsequently, the sectioned 3D models of the anterior maxilla were exported to 3-Matic software to reveal the predominant region and depth of RRR.

    RESULTS: The mean reduction in bone volume of the anterior maxilla in the CD group was 2.60% (SD = 1.71%, range = -4.89 % to -0.92%, median = -2.30%), while the mean reduction in the IRO group was almost three times higher at 7.25% (SD = 3.16%, range = -13.25 to -1.50, median = -7.15%). The predominant areas of RRR were on the buccal and occlusal ridge of the anterior maxilla.

    CONCLUSION: Within the limits of this study, it may be concluded that an IRO caused significantly higher RRR of the anterior maxilla than a CD.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported/adverse effects*
  16. Ong JEX
    Br Dent J, 2024 Nov;237(10):773-777.
    PMID: 39572811 DOI: 10.1038/s41415-024-7842-5
    This clinical report demonstrates how a two-implant mandibular implant-supported overdenture is planned and executed. The following steps feature the dual scan technique as part of implant planning and a radiographic-turned-surgical stent to guide a freehand, two-stage surgical placement of two implant fixtures on the bilateral canine positions of the mandibular arch.
    Matched MeSH terms: Dental Prosthesis, Implant-Supported*
  17. Patil PG, Seow LL, Uddanwadikar R, Ukey PD
    J Prosthet Dent, 2021 Jan;125(1):138.e1-138.e8.
    PMID: 33393474 DOI: 10.1016/j.prosdent.2020.09.015
    STATEMENT OF PROBLEM: Mini implants (<3 mm in diameter) are being used as an alternative to standard implants for implant-retained mandibular overdentures; however, they may exhibit higher stresses at the crestal level.

    PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical behavior (stress distribution pattern) in the mandibular overdenture, mucosa, bone, and implants when retained with 2 standard implants or 2 mini implants under unilateral or bilateral loading conditions.

    MATERIAL AND METHODS: A patient with edentulous mandible and his denture was scanned with cone beam computed tomography (CBCT), and a 3D mandibular model was created in the Mimics software program by using the CBCT digital imaging and communications in medicine (DICOM) images. The model was transferred to the 3Matics software program to form a 2-mm-thick mucosal layer and to assemble the denture DICOM file. A 12-mm-long standard implant (Ø3.5 mm) and a mini dental implant (Ø2.5 mm) along with the LOCATOR male attachments (height 4 mm) were designed by using the SOLIDWORKS software program. Two standard or 2 mini implants in the canine region were embedded separately in the 3D assembled model. The base of the mandible was fixed, and vertical compressive loads of 100 N were applied unilaterally and bilaterally in the first molar region. The material properties for acrylic resin (denture), titanium (implants), mucosa (tissue), and bone (mandible) were allocated. Maximum von Mises stress and strain values were obtained and analyzed.

    RESULTS: Maximum stresses of 9.78 MPa (bilaterally) and 11.98 MPa (unilaterally) were observed in 2 mini implants as compared with 3.12 MPa (bilaterally) and 3.81 MPa (unilaterally) in 2 standard implants. The stress values in the mandible were observed to be almost double the mini implants as compared with the standard implants. The stresses in the denture were in the range of 3.21 MPa and 3.83 MPa and in the mucosa of 0.68 MPa and 0.7 MPa for 2 implants under unilateral and bilateral loading conditions. The strain values shown similar trends with both implant types under bilateral and unilateral loading.

    CONCLUSIONS: Two mini implants generated an average of 68.15% more stress than standard implants. The 2 standard implant-retained overdenture showed less stress concentration in and around implants than mini implant-retained overdentures.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  18. Kher U, Patil PG, Tunkiwala A, Advani P
    J Prosthet Dent, 2020 08;124(2):248-249.
    PMID: 31810615 DOI: 10.1016/j.prosdent.2019.09.020
    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  19. Khalid T, Yunus N, Ibrahim N, Saleh NBM, Goode D, Masood M
    J Prosthet Dent, 2020 Dec;124(6):674-681.
    PMID: 31952858 DOI: 10.1016/j.prosdent.2019.08.005
    STATEMENT OF PROBLEM: Wearers of mandibular complete dentures (CDs) often complain of retention and stability problems resulting in poor masticatory function. Evidence suggests that a mandibular overdenture (MOD) stabilized by 2 implants represents the treatment of choice to improve stability and masticatory function. Measurements are needed of the improvement in masticatory function after providing mandibular implant-stabilized overdentures.

    PURPOSE: The purpose of this prospective clinical study was to evaluate the changes in masticatory function from baseline (T0) to 3 months (T1) and 3 years (T2) in participants with MODs and to assess the effect of baseline mandibular bone height and volume on masticatory function after 3 years.

    MATERIAL AND METHODS: Participants were assessed for masticatory function by using masticatory performance involving paraffin wax cubes as an objective measure and by using masticatory ability involving a questionnaire as a subjective measure. Edentulous individuals presenting for replacement dentures were provided with conventional mucosa-supported prostheses and evaluated for masticatory function after a 3-month settling-in period (baseline measure). Before implant placement, baseline measures of bone height and volume were recorded from cone beam computed tomography (CBCT) images. The prostheses were then converted to implant-stabilized mandibular overdentures while any maxillary prostheses remained supported by the mucosa. Masticatory function was reassessed at 3 months and 3 years after insertion of the mandibular overdentures, and the mean changes from baseline were analyzed with the Wilcoxon signed-rank test. The effect of variables on masticatory function was determined by using multivariate linear regression analyses.

    RESULTS: A total of 23 participants were included in the study, with only 1 participant not completing the 3-year assessment. Significant improvement was observed in the masticatory performance (mixing ability index) (Pimplant-stabilized mandibular overdenture.

    CONCLUSIONS: Masticatory function significantly improved after 3 months and was maintained over 3 years in participants with implant-stabilized mandibular overdentures. However, baseline bone height and volume had no significant effect on these changes in masticatory function after 3 years.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
  20. Alsrouji MS, Ahmad R, Ibrahim N, Kuntjoro W, Al-Harbi FA, Baba NZ
    J Prosthodont, 2019 Apr;28(4):373-378.
    PMID: 30875139 DOI: 10.1111/jopr.13047
    PURPOSE: Blood flow disturbance from functional pressure may lead to ischemia and accumulation of metabolites leading to residual ridge resorption (RRR) underneath complete dentures. The purposes of this study were to determine the effect of mandibular complete denture (CD) and implant-retained overdenture (IRO) on blood flow disturbance in the opposing denture bearing-mucosa of maxillary CD and to compare the blood flow disturbance to RRR of the anterior maxilla.

    MATERIALS AND METHODS: The test group included 9 participants rehabilitated by maxillary CD opposing mandibular IRO, while the control group consisted of 4 participants with CDs. Blood flow was measured by laser Doppler flowmetry (LDF) after denture removal for 0, 30, 60, and 90 minutes. RRR was quantified as reduction in bone volume a year post-treatment. The measurement of blood flow was then compared to the quantification of RRR.

    RESULTS: The mean blood flow measure for the IRO group was significantly lower than CD after immediate denture removal and 30 minutes later. After 60 minutes, the mean difference was not significant between groups, and at 90 minutes, the mean blood flow of both groups equalized to reach a steady state of 377 BPU. The mandibular IRO had reduced the initial blood flow measure in the opposing anterior maxilla mucosa to almost a quarter (103 BPU) of the steady state value (377 BPU) compared to the CD, which reduced it to only about one half (183 BPU), suggesting greater blood flow disturbance in the IRO group. This result is in tandem with the greater reduction of bone volume observed in the IRO group, which was 7.3 ± 1.3% after a year, almost three times higher than CD group at 2.6 ± 1.7%.

    CONCLUSION: IRO may cause significantly higher blood flow disturbance than CD and may have contributed to greater RRR in the anterior maxilla.

    Matched MeSH terms: Dental Prosthesis, Implant-Supported
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links