MATRIALS AND METHODS: The conventional protocol and three microwave protocols of tissue processing were used in this study. A pilot study was done prior to the real run to determine the baseline timing for microwave protocol. The baseline timing was fixed at 2 minutes,30 minutes,5 minutes and 25 minutes. The processing time of the microwave protocol was adjusted from 62 minutes to 70 minutes to 77 minutes by increasing the dehydration and wax impregnation time while the time for tissue fixation and clearing remain the same throughout all the microwave protocols.
RESULTS: The group 2 microwave protocol produced the sections that is closely comparable to group 1 conventional protocol. The morphological quality of histopathology slides is best observed when the processing time of microwave protocol is 62 minutes.
CONCLUSION: The most appropriate microwave protocol for tissue processing is group 2 as the morphological quality of histopathology slides are more superior than that of group 1 with an overall percentage of 80% of satisfactory slides in group 2 and 76.68% in group 1.
METHODS: This was a prospective single center study which recruited 217 asymptomatic adult male participants in a coronavirus disease 2019 (COVID-19) quarantine center who had tested positive for SARS-CoV-2 8-10 days prior to isolation. Paired NPS and saliva specimens were collected and processed within 5 hours of sample collection. Real time reverse transcription polymerase chain reaction (RT-PCR) targeting Envelope (E) and RNA-dependent RNA polymerase (RdRp) genes was performed and the results were compared.
RESULTS: Overall, 160 of the 217 (74%) participants tested positive for COVID-19 based on saliva, NPS, or both testing methods. The detection rate for SARS-CoV-2 was higher in saliva compared to NPS testing (93.1%, 149/160 vs 52.5%, 84/160, P < .001). The concordance between the 2 tests was 45.6% (virus was detected in both saliva and NPS in 73/160), whereas 47.5% were discordant (87/160 tested positive for 1 whereas negative for the other). The cycle threshold (Ct) values for E and RdRp genes were significantly lower in saliva specimens compared to NP swab specimens.
CONCLUSIONS: Our findings demonstrate that saliva is a better alternative specimen for detection of SARS-CoV-2. Taking into consideration, the simplicity of specimen collection, shortage of PPE and the transmissibility of the virus, saliva could enable self-collection for an accurate SARS-CoV-2 surveillance testing.
MATERIALS AND METHODS: This is a cross-sectional study where women aged between 20-80 years were recruited via convenient sampling from villages in Long Banga, Sarawak over a five-day outreach programme. Cervicovaginal selfsamples were obtained and screened for the presence of high-risk human papillomavirus DNA (HR-HPV) using the careHPVTM Test. A self-administered questionnaire was also administered to determine the sociodemographic and perception towards the self-sampling method.
RESULTS: The 55 women recruited consist of ethnic backgrounds of Penan (58.18%), Kenyah (25.45%), Iban (5.45%), Saban (3.64%), Kelabit (3.64%), Malay (1.82%) and Chinese (1.82%). The prevalence of HR-HPV was 1.85% (n=1/55). Nearly 80% of the women were unemployed, and more than half have had attended primary education. Nine (16.4%) have heard about HPV, and seven (13%) knew HPV infection could cause cervical cancer. Three of them had HPV vaccination, and only one (1.85%) knew the brand of the HPV vaccine. Although 40% preferred self-sampling over clinician-collection, only ten (18.2%) women have completed the self-collection perception questionnaire.
CONCLUSION: Primary HPV DNA screening using the selfsampling method can be carried out in the remote areas during the COVID-19 pandemic without compromising mobility restriction.
OBJECTIVE: Several European and international consensus statements concerning faecal microbiota transplantation have been issued. While these documents provide overall guidance, we aim to provide a detailed description of all processes that relate to the collection, handling and clinical application of human donor stool in this document.
METHODS: Collaborative subgroups of experts on stool banking drafted concepts for all domains pertaining to stool banking. During a working group meeting in the United European Gastroenterology Week 2019 in Barcelona, these concepts were discussed and finalised to be included in our overall guidance document about faecal microbiota transplantation.
RESULTS: A guidance document for all domains pertaining to stool banking was created. This document includes standard operating manuals for several processes involved with stool banking, such as handling of donor material, storage and donor screening.
CONCLUSION: The implementation of faecal microbiota transplantation by stool banks in concordance with our guidance document will enable quality assurance and guarantee the availability of donor faeces preparations for patients.
METHODS: We recruited 81 travelers and 15 non-travelers (including ten controls) prospectively within a mean of 3·22 days of RT-PCR confirmed COVID-19. Each study participant provided 2 mls of early morning fresh drooled whole saliva separately into a sterile plastic container and GeneFiX™ saliva collection kit. The saliva specimens were processed within 4 h and tested for SARS-CoV-2 genes (E, RdRP, and N2) and the results compared to paired NPS RT-PCR for diagnostic accuracy.
RESULTS: Majority of travellers were asymptomatic (75·0%) with a mean age of 34·26 years. 77 travelers were RT-PCR positive at the time of hospitalization whilst three travelers had positive contacts. In this group, the detection rate for SARS-CoV-2 with NPS, whole saliva, and GeneFiX™ were comparable (89·3%, 50/56; 87·8%, 43/49; 89·6%, 43/48). Both saliva collection methods were in good agreement (Kappa = 0·69). There was no statistical difference between the detection rates of saliva and NPS (p > 0·05). Detection was highest for the N2 gene whilst the E gene provided the highest viral load (mean = 27·96 to 30·10, SD = 3·14 to 3·85). Saliva specimens have high sensitivity (80·4%) and specificity (90·0%) with a high positive predictive value of 91·8% for SARS-CoV-2 diagnosis.
CONCLUSION: Saliva for SARS-CoV-2 screening is a simple accurate technique comparable with NPS RT-PCR.
OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).
STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.
RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).
CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.
METHODS: Twelve relevant manuscripts were sourced from a total of 7288 search results obtained using PubMed, Medline and Google Scholar. The search keywords used were COVID-19, nasopharyngeal, oropharyngeal, swabs, SARS and CoV2. Original manuscripts were obtained and analysed by all authors. The review included manuscripts which have not undergone rigorous peer-review process in view of the magnitude of the topic discussed.
RESULTS: The viral load of SARS-CoV-2 RNA in the upper respiratory tract was significantly higher during the first week and peaked at 4-6 days after onset of symptoms, during which it can be potentially sampled. Nasopharyngeal swab has demonstrated higher viral load than oropharyngeal swab, where the difference in paired samples is best seen at 0-9 days after the onset of illness. Sensitivity of nasopharyngeal swab was higher than oropharyngeal swabs in COVID-19 patients. Patient self-collected throat washing has been shown to contain higher viral load than nasopharyngeal or oropharyngeal swab, with significantly higher sensitivity when compared with paired nasopharyngeal swab.
RECOMMENDATIONS: Routine nasopharyngeal swab of suspected COVID-19 infection should take anatomy of the nasal cavity into consideration to increase patient comfort and diagnostic yield. Routine oropharyngeal swab should be replaced by throat washing which has demonstrated better diagnostic accuracy, and it is safe towards others.
METHODS: A total of 322 samples of mainly human origin were analysed using eight protocols, applying a wide variety of laboratory components. Several samples (60% of human specimens) were processed using different protocols. In total, 712 sequencing libraries were investigated for viral sequence contamination.
RESULTS: Among sequences showing similarity to viruses, 493 were significantly associated with the use of laboratory components. Each of these viral sequences had sporadic appearance, only being identified in a subset of the samples treated with the linked laboratory component, and some were not identified in the non-template control samples. Remarkably, more than 65% of all viral sequences identified were within viral clusters linked to the use of laboratory components.
CONCLUSIONS: We show that high prevalence of contaminating viral sequences can be expected in HTS-based virome data and provide an extensive list of novel contaminating viral sequences that can be used for evaluation of viral findings in future virome and metagenome studies. Moreover, we show that detection can be problematic due to stochastic appearance and limited non-template controls. Although the exact origin of these viral sequences requires further research, our results support laboratory-component-linked viral sequence contamination of both biological and synthetic origin.