Displaying all 12 publications

Abstract:
Sort:
  1. Ong P, Yeh CW, Tsai IL, Lee WJ, Wang YJ, Chuang YK
    PMID: 37531681 DOI: 10.1016/j.saa.2023.123214
    Consumption of agricultural products with pesticide residue is risky and can negatively affect health. This study proposed a nondestructive method of detecting pesticide residues in chili pepper based on the combination of visible and near-infrared (VIS/NIR) spectroscopy (400-2498 nm) and deep learning modeling. The obtained spectra of chili peppers with two types of pesticide residues (acetamiprid and imidacloprid) were analyzed using a one-dimensional convolutional neural network (1D-CNN). Compared with the commonly used partial least squares regression model, the 1D-CNN approach yielded higher prediction accuracy, with a root mean square error of calibration of 0.23 and 0.28 mg/kg and a root mean square error of prediction of 0.55 and 0.49 mg/kg for the acetamiprid and imidacloprid data sets, respectively. Overall, the results indicate that the combination of the 1D-CNN model and VIS/NIR spectroscopy is a promising nondestructive method of identifying pesticide residues in chili pepper.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods
  2. Omar AF, MatJafri MZ
    Sensors (Basel), 2013;13(4):4876-83.
    PMID: 23584118 DOI: 10.3390/s130404876
    This study presents a novel application of near infrared (NIR) spectral linearisation for measuring the soluble solids content (SSC) of carambola fruits. NIR spectra were measured using reflectance and interactance methods. In this study, only the interactance measurement technique successfully generated a reliable measurement result with a coefficient of determination of (R2) = 0.724 and a root mean square error of prediction for (RMSEP) = 0.461° Brix. The results from this technique produced a highly accurate and stable prediction model compared with multiple linear regression techniques.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  3. Husain SF, Chiang SK, Vasu AA, Goh CP, McIntyre RS, Tang TB, et al.
    J Atten Disord, 2023 Nov;27(13):1448-1459.
    PMID: 37341192 DOI: 10.1177/10870547231180111
    OBJECTIVE: Functional near-infrared spectroscopy (fNIRS) provides direct and quantitative assessment of cortical hemodynamic response. It has been used to identify neurophysiological alterations in medication-naïve adults with attention-deficit/hyperactivity disorder (ADHD). Hence, this study aimed to distinguish both medication-naïve and medicated adults with ADHD from healthy controls (HC).

    METHOD: 75 HCs, 75 medication-naïve, and 45 medicated patients took part in this study. fNIRS signals during a verbal fluency task (VFT) were acquired using a 52-channel system and relative oxy-hemoglobin changes in the prefrontal cortex were quantified.

    RESULTS: Prefrontal cortex hemodynamic response was lower in patients than HCs (p ≤ ≤.001). Medication-naïve and medicated patients did not differ in hemodynamic response or symptom severity (p > .05). fNIRS measurements were not associated with any clinical variables (p > .05). 75.8% patients and 76% HCs were correctly classified using hemodynamic response.

    CONCLUSION: fNIRS may be a potential diagnostic tool for adult ADHD. These findings need to be replicated in larger validation studies.

    Matched MeSH terms: Spectroscopy, Near-Infrared/methods
  4. Chia KS, Abdul Rahim H, Abdul Rahim R
    J Zhejiang Univ Sci B, 2012 Feb;13(2):145-51.
    PMID: 22302428 DOI: 10.1631/jzus.B11c0150
    Visible and near infrared spectroscopy is a non-destructive, green, and rapid technology that can be utilized to estimate the components of interest without conditioning it, as compared with classical analytical methods. The objective of this paper is to compare the performance of artificial neural network (ANN) (a nonlinear model) and principal component regression (PCR) (a linear model) based on visible and shortwave near infrared (VIS-SWNIR) (400-1000 nm) spectra in the non-destructive soluble solids content measurement of an apple. First, we used multiplicative scattering correction to pre-process the spectral data. Second, PCR was applied to estimate the optimal number of input variables. Third, the input variables with an optimal amount were used as the inputs of both multiple linear regression and ANN models. The initial weights and the number of hidden neurons were adjusted to optimize the performance of ANN. Findings suggest that the predictive performance of ANN with two hidden neurons outperforms that of PCR.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  5. Raypah ME, Omar AF, Muncan J, Zulkurnain M, Abdul Najib AR
    Molecules, 2022 Apr 03;27(7).
    PMID: 35408723 DOI: 10.3390/molecules27072324
    Honey is a natural product that is considered globally one of the most widely important foods. Various studies on authenticity detection of honey have been fulfilled using visible and near-infrared (Vis-NIR) spectroscopy techniques. However, there are limited studies on stingless bee honey (SBH) despite the increase of market demand for this food product. The objective of this work was to present the potential of Vis-NIR absorbance spectroscopy for profiling, classifying, and quantifying the adulterated SBH. The SBH sample was mixed with various percentages (10−90%) of adulterants, including distilled water, apple cider vinegar, and high fructose syrup. The results showed that the region at 400−1100 nm that is related to the color and water properties of the samples was effective to discriminate and quantify the adulterated SBH. By applying the principal component analysis (PCA) on adulterants and honey samples, the PCA score plot revealed the classification of the adulterants and adulterated SBHs. A partial least squares regression (PLSR) model was developed to quantify the contamination level in the SBH samples. The general PLSR model with the highest coefficient of determination and lowest root means square error of cross-validation (RCV2=0.96 and RMSECV=5.88 %) was acquired. The aquaphotomics analysis of adulteration in SBH with the three adulterants utilizing the short-wavelength NIR region (800−1100 nm) was presented. The structural changes of SBH due to adulteration were described in terms of the changes in the water molecular matrix, and the aquagrams were used to visualize the results. It was revealed that the integration of NIR spectroscopy with aquaphotomics could be used to detect the water molecular structures in the adulterated SBH.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods
  6. Ghani KA, Sudik S, Omar AF, Mail MH, Seeni A
    PMID: 31216502 DOI: 10.1016/j.saa.2019.117241
    Cancer is increasing in incidence and the leading cause of death worldwide. Controlling and reducing cancer requires early detection and technique to accurately detect and quantify predictive biomarkers. Optical spectroscopy has shown promising non-destructive ability to display distinctive spectral characteristics between cancerous and normal tissues from different part of human organ. Nonetheless, not many information is available on spectroscopic properties of cancer cell lines. In this research, the visible-near infrared (VIS-NIR) absorbance spectroscopy measurement of cultured cervical cancer (HeLa) and prostate cancer cells (DU145) lines has been performed to develop spectral signature of cancer cells and to generate algorithm to quantify cancer cells. Spectroscopic measurement on mouse skin fibroblast (L929) was also taken for comparative purposes. In visible region, the raw cells' spectra do not produce any noticeable peak absorbance that provides information on color because the medium used for cells is colorless and transparent. NIR wavelength between 950 and 975 nm exhibit significant peak due to water absorbance by the medium. Development of spectral signature for the cells through the application of regression technique significantly enhances the diverse characteristics between L929, HeLa and DU145. The application of multiple linear regression allows high measurement accuracy of the cells with coefficient of determination above 0.94.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  7. Basri KN, Hussain MN, Bakar J, Sharif Z, Khir MFA, Zoolfakar AS
    Spectrochim Acta A Mol Biomol Spectrosc, 2017 Feb 15;173:335-342.
    PMID: 27685001 DOI: 10.1016/j.saa.2016.09.028
    Short wave near infrared spectroscopy (NIR) method was used to detect the presence of lard adulteration in palm oil. MicroNIR was set up in two different scan modes to study the effect of path length to the performance of spectral measurement. Pure and adulterated palm oil sample were classified using soft independent modeling class analogy (SIMCA) algorithm with model accuracy more than 0.95 reported for both transflectance and transmission modes. Additionally, by employing partial least square (PLS) regression, the coefficient of determination (R2) of transflectance and transmission were 0.9987 and 0.9994 with root mean square error of calibration (RMSEC) of 0.5931 and 0.6703 respectively. In order to remove the uninformative variables, variable selection using cumulative adaptive reweighted sampling (CARS) has been performed. The result of R2 and RMSEC after variable selection for transflectance and transmission were improved significantly. Based on the result of classification and quantification analysis, the transmission mode has yield better prediction model compared to the transflectance mode to distinguish the pure and adulterated palm oil.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  8. Said MM, Gibbons S, Moffat AC, Zloh M
    Int J Pharm, 2011 Aug 30;415(1-2):102-9.
    PMID: 21645600 DOI: 10.1016/j.ijpharm.2011.05.057
    The influx of medicines from different sources into healthcare systems of developing countries presents a challenge to monitor their origin and quality. The absence of a repository of reference samples or spectra prevents the analysis of tablets by direct comparison. A set of paracetamol tablets purchased in Malaysian pharmacies were compared to a similar set of sample purchased in the UK using near-infrared spectroscopy (NIRS). Additional samples of products containing ibuprofen or paracetamol in combination with other actives were added to the study as negative controls. NIR spectra of the samples were acquired and compared by using multivariate modeling and classification algorithms (PCA/SIMCA) and stored in a spectral database. All analysed paracetamol samples contained the purported active ingredient with only 1 out of 20 batches excluded from the 95% confidence interval, while the negative controls were clearly classified as outliers of the set. Although the substandard products were not detected in the purchased sample set, our results indicated variability in the quality of the Malaysian tablets. A database of spectra was created and search methods were evaluated for correct identification of tablets. The approach presented here can be further developed as a method for identifying substandard pharmaceutical products.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  9. Husain SF, Yu R, Tang TB, Tam WW, Tran B, Quek TT, et al.
    Sci Rep, 2020 06 16;10(1):9740.
    PMID: 32546704 DOI: 10.1038/s41598-020-66784-2
    Reduced haemodynamic response in the frontotemporal cortices of patients with major depressive disorder (MDD) has been demonstrated using functional near-infrared spectroscopy (fNIRS). Most notably, changes in cortical oxy-haemoglobin during a Japanese phonetic fluency task can differentiate psychiatric patients from healthy controls (HC). However, this paradigm has not been validated in the English language. Therefore, the present work aimed to distinguish patients with MDD from HCs, using haemodynamic response measured during an English letter fluency task. One hundred and five HCs and 105 patients with MDD took part in this study. NIRS signals during the verbal fluency task (VFT) was acquired using a 52-channel system, and changes in oxy-haemoglobin in the frontal and temporal regions were quantified. Depression severity, psychosocial functioning, pharmacotherapy and psychiatric history were noted. Patients with MDD had smaller changes in oxy-haemoglobin in the frontal and temporal cortices than HCs. In both regions of interest, oxy-haemoglobin was not associated with any of the clinical variables studied. 75.2% and 76.5% of patients with MDD were correctly classified using frontal and temporal region oxy-haemoglobin, respectively. Haemodynamic response measured by fNIRS during an English letter fluency task is a promising biomarker for MDD.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
  10. Hasnan N, Mohamad Saadon NS, Hamzaid NA, Teoh MX, Ahmadi S, Davis GM
    Medicine (Baltimore), 2018 Oct;97(43):e12922.
    PMID: 30412097 DOI: 10.1097/MD.0000000000012922
    This study compared muscle oxygenation (StO2) during arm cranking (ACE), functional electrical stimulation-evoked leg cycling (FES-LCE), and hybrid (ACE+FES-LCE) exercise in spinal cord injury individuals. Eight subjects with C7-T12 lesions performed exercises at 3 submaximal intensities. StO2 was measured during rest and exercise at 40%, 60%, and 80% of subjects' oxygen uptake (VO2) peak using near-infrared spectroscopy. StO2 of ACE showed a decrease whereas in ACE+FES-LCE, the arm muscles demonstrated increasing StO2 from rest in all of VO2) peak respectively. StO2 of FES-LCE displayed a decrease at 40% VO2 peak and steady increase for 60% and 80%, whereas ACE+FES-LCE revealed a steady increase from rest at all VO2 peak. ACE+FES-LCE elicited greater StO2 in both limbs which suggested that during this exercise, upper- and lower-limb muscles have higher blood flow and improved oxygenation compared to ACE or FES-LCE performed alone.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods
  11. Poh AH, Adikan FRM, Moghavvemi M
    Med Biol Eng Comput, 2020 Jun;58(6):1159-1175.
    PMID: 32319030 DOI: 10.1007/s11517-019-02077-9
    The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a closer look into applications potentially for detecting or monitoring diseases. One of the challenges in this field is in establishing a reference for applications which correspond to certain bandwidths. This article reviews the scope on past research on skin spectroscopy, and the clinical aspects which have or may have applications on disease detection or enhancing diagnostics. A summary is supplied on the technicalities surrounding the measurements reported in literature, focused towards the wavelength-dependent applications in themes central to the respective research. Analytics on the topology of the papers' data cited in this work is also provided for a statistical perspective. In short, this paper strives to immediately inform the reader with possible applications via the spectroscopic devices at hand. Graphical Abstract .
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods
  12. Citartan M, Gopinath SC, Tominaga J, Chen Y, Tang TH
    Talanta, 2014 Aug;126:103-9.
    PMID: 24881539 DOI: 10.1016/j.talanta.2014.03.043
    Label-free-based detection is pivotal for real-time monitoring of biomolecular interactions and to eliminate the need for labeling with tags that can occupy important binding sites of biomolecules. One simplest form of label-free-based detection is ultraviolet-visible-near-infrared (UV-vis-NIR) spectroscopy, which measure changes in reflectivity as a means to monitor immobilization and interaction of biomolecules with their corresponding partners. In biosensor development, the platform used for the biomolecular interaction should be suitable for different molecular recognition elements. In this study, gold (Au)-coated polycarbonate was used as a platform and as a proof-of-concept, erythropoietin (EPO), a doping substance widely abused by the athletes was used as the target. The interaction of EPO with its corresponding molecular recognition elements (anti-EPO monoclonal antibody and anti-EPO DNA aptamer) is monitored by UV-vis-NIR spectroscopy. Prior to this, to show that UV-vis-NIR spectroscopy is a suitable method for measuring biomolecular interaction, the interaction between biotin and streptavidin was demonstrated via this strategy and reflectivity of this interaction decreased by 25%. Subsequent to this, interaction of the EPO with anti-EPO monoclonal antibody and anti-EPO DNA aptamer resulted in the decrease of reflectivity by 5% and 10%, respectively. The results indicated that Au-coated polycarbonate could be an ideal biosensor platform for monitoring biomolecular interactions using UV-vis-NIR spectroscopy. A smaller version of the Au-coated polycarbonate substrates can be derived from the recent set-up, to be applied towards detecting EPO abuse among atheletes.
    Matched MeSH terms: Spectroscopy, Near-Infrared/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links