Displaying all 10 publications

Abstract:
Sort:
  1. Fadzil FM, Choon D, Arumugam K
    Aust Fam Physician, 2010 Apr;39(4):237-9.
    PMID: 20372685
    This study assessed the concordance of the temperatures of the digital, liquid crystal forehead and digital infrared tympanic thermometers with the mercury in glass thermometer.
    Matched MeSH terms: Thermometers/standards*
  2. Teng CL, Ng CJ, Hanafi NS, Zailinawati AH, Tong SF
    J Trop Pediatr, 2008 Feb;54(1):70-3.
    PMID: 18039678 DOI: 10.1093/tropej/fmm077
    Universally, mothers often use touching to detect fever in their children. We perform a systematic review of published diagnostic studies evaluating the ability of mothers to detect fever in their children by touching. We found 10 studies satisfying our inclusion criteria. The meta-analysis revealed a summary sensitivity of 89.2% and summary specificity of 50%-maternal touch is perhaps more useful to exclude fever rather than to 'rule in' fever. However, due to significant heterogeneity in the included studies, interpretation of the summary data is difficult.
    Matched MeSH terms: Thermometers
  3. Brandon-Mong GJ, Gan HM, Sing KW, Lee PS, Lim PE, Wilson JJ
    Bull. Entomol. Res., 2015 Dec;105(6):717-27.
    PMID: 26344799 DOI: 10.1017/S0007485315000681
    Metabarcoding, the coupling of DNA-based species identification and high-throughput sequencing, offers enormous promise for arthropod biodiversity studies but factors such as cost, speed and ease-of-use of bioinformatic pipelines, crucial for making the leapt from demonstration studies to a real-world application, have not yet been adequately addressed. Here, four published and one newly designed primer sets were tested across a diverse set of 80 arthropod species, representing 11 orders, to establish optimal protocols for Illumina-based metabarcoding of tropical Malaise trap samples. Two primer sets which showed the highest amplification success with individual specimen polymerase chain reaction (PCR, 98%) were used for bulk PCR and Illumina MiSeq sequencing. The sequencing outputs were subjected to both manual and simple metagenomics quality control and filtering pipelines. We obtained acceptable detection rates after bulk PCR and high-throughput sequencing (80-90% of input species) but analyses were complicated by putative heteroplasmic sequences and contamination. The manual pipeline produced similar or better outputs to the simple metagenomics pipeline (1.4 compared with 0.5 expected:unexpected Operational Taxonomic Units). Our study suggests that metabarcoding is slowly becoming as cheap, fast and easy as conventional DNA barcoding, and that Malaise trap metabarcoding may soon fulfill its potential, providing a thermometer for biodiversity.
    Matched MeSH terms: Thermometers
  4. Mondal H, Mondal S
    Malays Fam Physician, 2021 Mar 25;16(1):8-14.
    PMID: 33948137 DOI: 10.51866/rv1097
    Home health monitoring devices are consumer-grade devices that help to monitor the health of individuals at home. These devices are usually low-cost and easily procurable, and they can be operated by patients or their caretakers with minimal training. However, improper usage of these devices may provide erroneous results, which can lead to an unnecessary hospital visit or teleconsultation. In this article, we discuss the basic technology and proper usage of some of these devices, namely automatic blood pressure monitors, blood glucose monitors, body fat monitors, pulse oximeters, electrocardiographs, digital thermometers, and infrared thermometers. This brief document intends to help primary health care professionals and their patients use these devices.
    Matched MeSH terms: Thermometers
  5. Soon JM, Wahab IRA, Hamdan RH, Jamaludin MH
    PLoS One, 2020;15(7):e0235870.
    PMID: 32639978 DOI: 10.1371/journal.pone.0235870
    Factors contributing to foodborne illnesses in Malaysia were identified as insanitary food handling procedures and lack of hygiene in food preparation area. Food safety at home is a critical point as consumers represent the final step in food preparation and prevention of foodborne diseases. This study aims to investigate the food safety knowledge, attitude and self-reported practices among consumers in Malaysia. An online survey was conducted, and data were analysed using descriptive statistics and exploratory factor analysis. A model linking food safety knowledge and attitude and their direct effects on practices were confirmed using structural equation modelling (SEM). The proposed model fulfilled the goodness of fit indices and is deemed acceptable. Respondents demonstrate good level of food safety knowledge and positive attitudes and self-reported practices. Food safety knowledge has a negative and insignificant relationship with food safety practices (β1 = -0.284, p>0.05) while attitude significantly affects food safety practices (β1 = 0.534, p<0.05). The findings clearly indicate that food safety knowledge does not directly affect food safety practices This is also the first study to provide new empirical findings on thermometer usage among consumers in Malaysia. This study establishes an important point of reference where consumers use visual appearances to determine if food is thoroughly cooked and practice washing raw chicken prior to cooking. Food safety practices at home play a critical role in protecting consumers in reducing risks of foodborne illnesses.
    Matched MeSH terms: Thermometers
  6. Nadia, H.I., Raha, A.R.
    MyJurnal
    Intraoperative active warming in daycare surgery may be least popular compared to major elective surgeries due to the lesser risk of perioperative hypothermia. This prospective, single blind, randomized, controlled trial in daycare breast lumpectomy was done to evaluate the routine use of intraoperative forced-air warmer in the presence of other warming modalities in prevention of perioperative hypothermia. Fifty patients were randomized into two groups; Group 1 received forced-air warmer and Group 2 received a standard cotton thermal blanket. Both groups received circulating-water mattress. Intraoperatively, all patients received pre-warmed intravenous fluid with an in-line warmer. Ear and ambient temperature was recorded using infrared ear thermometer and digital thermo-hygrometer respectively. Measurement was done before induction, every 15 minutes intraoperatively, upon arrival in recovery room and 30 mins later, postoperatively. All patients were normothermic prior to induction of anaesthesia. During the initial half an hour post-induction, both groups mean core temperature decreased at approximately 0 ̊.C5 . Both showed no statistical difference in mean core temperature (0.04 ̊C) within the initial half an hour. The next half an hour, both groups had approximately 0 ̊.C2 decrement but this time, Group 2 had a slightly higher mean core temperature than Group 1 which maintained until the end of surgery. Overall, within the initial one hour post- induction of GA, there was a drop of 0.7 ̊C and 0.6°C in Group 1 and Group 2 respectively, however the difference in final mean core temperature between the two groups was 0.05°C and it was not statistically significant (p value < 0.05). None of the patients experienced intraoperative hypothermia (< 36 ̊C) and all remained in the normothermic range with no shivering or sense of feeling cold, postoperatively. The results of the present study found no significant difference in the changes of final core temperature with or without the usage of intraoperative forced-air warmer in the presence of other warming measures in daycare breast lumpectomy.
    Matched MeSH terms: Thermometers
  7. Leman, A.M., Che Wan Izzudin, Md Zin Ibrahim, Dafit Feriyanto
    MyJurnal
    Brake pad apparatus is designed for help student and instructor in teaching and learning application. The objective
    of this research is to differentiate the pressure effect and braking temperature condition of different pad. This apparatus
    also aimed for learning the safety car and motorcycle braking system. This apparatus can to compare with theoretical
    calculation in order to approve that this apparatus is useful. The main concept in this apparatus is thermocouple use
    to detect the temperature gain while braking process. Speed motor controller used for set the angular velocity of the
    motor in braking process. Pressure applied at brake pedal detected by pressure gauge and data logger function as a
    connector. This apparatus also designed based on valid data for average of teenager in Malaysia which made on a
    sample university student. Result show that the apparatus can function effectively by defines the different temperature
    when applied the different pressure and different pad. Pad C shows the 880C for thermocouple 1 and 790C for
    thermocouple 2 at the 20 psi and infrared thermometer show 1130C for pad C. Graph from calculation shows that the
    pad A have 216.480C at 1000 rpm which have low temperature than pad B, C and D. high efficiency of friction and
    pressure applied will cause more heat generate than low coefficient of friction and pressure applied.
    Matched MeSH terms: Thermometers
  8. Nehdi IA, Sbihi HM, Blidi LE, Rashid U, Tan CP, Al-Resayes SI
    Protein Pept Lett, 2018;25(2):164-170.
    PMID: 28240158 DOI: 10.2174/0929866524666170223150839
    BACKGROUND: Biodiesel is a green fuel consisting of long chain fatty acid monoalkyl esters, which can be blended with diesel or used alone which is usually produced from vegetable oils/fats by either lipasecatalyzed transesterification. In this investigation, an enzyme (Novozym 435) catalyzed process was optimized to prepare methyl esters from crude Citrullus colocynthis oil (CCO) by transesterification of CCO with methanol. However, as per our knowledge, lipase-catalyzed transesterification have not been used for biodiesel production from Citrullus colocynthis.

    OBJECTIVE: The purpose of this work was to transesterify the CCO in the presence of Candida antarctica lipase as catalyst and methanol. Additionally, the physicochemical parameters/fuel properties of the Citrullus colocynthis methyl ester (CCME) were assessed and compared.

    METHODS: Lipase-catalyzed reactions were carried out in three necked flask (50 mL) attached with reflux condenser and thermometer, immersed in oil bath at constant stirring speed (400 rpm). The reaction mixture was consisted of CCO and varying the calculated amount of methanol, tert-butyl alcohol, and Novozym 435. The experimental parameters reaction time, methanol/oil molar ratio, reaction temperature, tert-butanol content, Novozym 435 content and water content were optimized for the transesterification reaction. The CCME yield was measured using gas chromatograph. The fuel properties of the produced CCME were determined as per American Society for Testing and Materials (ASTM) and European (EN) biodiesel standard methods.

    RESULTS: In this study, an enzymatic catalyst was employed to synthesize the CCME from CCO via transesterification. Several variables affecting the CCME yield were optimized as lipase quantity (4%), water content (0.5%), methanol/oil molar ratio (5:1), reaction temperature (43 °C), reaction medium composition (80% tertbutanol/ oil), and reaction time (3.7 h). A CCME yield of 97.8% was achieved using enzyme catalyzed transesterification of CCO under optimal conditions. The significant biodiesel fuel properties of CCME, i.e. cloud point (0.70 °C); cetane number (49.07); kinematic viscosity (2.27 mm2/s); flash point (143 °C); sulfur content (2 ppm) density (880 kg/m3) and acid value (0.076 mg KOH/g) were appraised. CCME also exhibited long-term storage stability (4.80 h) and all the biodiesel fuel properties were within the range of standards (ASTM D6751 and EN 14214).

    CONCLUSION: The lipase-catalyzed transesterification produced better conversion than the base-catalyzed reaction. The fuel properties of CCME were within the limits of the ASTM D6751 and EN14214 standards. Furthermore, CCME showed good oxidative stability and a long shelf life due its high natural antioxidant content. CCME showed better fuel properties and long-term storage stability due to which it can be used as a potential alternative fuel.

    Matched MeSH terms: Thermometers
  9. Aminnudin AN, Doss JG, Ismail SM, Chai MB, Abidin MZ, Basri CSJM, et al.
    Ecancermedicalscience, 2020;14:1118.
    PMID: 33209109 DOI: 10.3332/ecancer.2020.1118
    Background: Oral cancer and its treatment impact patients' post-treatment outcomes, challenging clinicians to manage them optimally. Addressing patients' concerns is central to holistic patient-centred care.

    Objectives: This study aimed to determine post-treatment oral cancer patients' concerns and its relationship with patients' clinical characteristics, health-related quality of life (HRQoL), psychological distress and patient satisfaction with the follow-up consultation.

    Methods: A total of 85 oral cancer patients were recruited from a three-armed pragmatic RCT study on the patient concerns inventory for head and neck cancer (PCI-H&N), which was conducted at six hospital-based oral maxillofacial specialist clinics throughout Malaysia. Malaysians aged 18 years and above and on follow-ups from 1 month to 5 years or more were eligible. Patients completed the PCI-H&N, functional assessment of cancer therapy -H&N v4.0 and Distress Thermometer at pre-consultation and satisfaction questionnaire at post-consultation. The data were analysed descriptively; multiple linear regression and multivariate logistic regression analyses were used to determine possible predictors of patients' HRQoL and psychological distress.

    Results: 'Recurrence or fear of cancer coming back' (31.8%) was most frequently selected. 43.5% of patients selected ≥4 concerns. A significantly high number of concerns were associated with patients of '1-month to 1-year post-treatment' (n = 84%; p = 0.001). A significant association existed between 'time after treatment completed' and patients' concerns of 'chewing/eating', 'mouth opening', 'swelling', 'weight', 'ability to perform', 'cancer treatment' and 'supplement/diet-related'. 'Chewing/eating' was predicted for low HRQoL (p < 0.0001) followed by 'appearance' and 'ability to perform recreation activities' (personal functions domain). Patients with high psychological distress levels were 14 times more likely to select 'ability to perform recreation activities' and seven times more likely to select 'feeling depressed'. No significant association was identified between patients' concerns and patients' satisfaction with the consultation.

    Conclusion: Routine follow-up consultations should incorporate the PCI-H&N prompt list to enhance patient-centred care approach as the type and number of patients' concerns are shown to reflect their HRQoL and psychological distress.TRIAL REGISTRATION: NMRR-18-3624-45010 (IIR).

    Matched MeSH terms: Thermometers
  10. Goh See Ben, Zailina Hashim, Rosnan Hamzah
    MyJurnal
    A cross sectional study to determine the exposure of heat and its biological effects on the workers in a plastic factory located in the Shah Alam Industrial Estate, Selangor, Malaysia. Forty five respondents from the polymer section in the factory were selected as the respondents. Variables measured were the environmental temperature (WBGTin), air velocity, relative humidity, body temperature, average heart and recovery heart rate. QUESTEMP°34 Area Heat Stress Monitor was used to measure the environmental temperature in °C (WBGTin) and relative humidity (%). Velocicheck Model TSI 8830 was used to measure the air velocity in meter per second (m/s) while the OMRON Blood Pressure Monitor Model T3, was used to measure average heart rate and recovery heart rate. Body temperature (°C) was measured by the Instant Ear Thermometer-OMRON Gentle Temperature Model MC509. Interviews using questionnaires were used to determine respondents’ socioeconomic background, previous risk factors on heat exposure and other information related to heat stress. Results showed that the mean environmental temperature for the exposed group was 28.75°C, the mean air velocity was 0.15 m/s and the mean relative humidity was 58.1%. These production workers were exposed occasionally to heat when loading plastic powder into the molds as well as demolding the finished plastic products from the molds. The average time of monitoring was 2 hours for intermittent exposure and 8 hours duration for overall exposure. Maximum demand for work load was measured 1 minute after work activities were stopped at the demolding section. There was a significant difference between body temperature and average heart rate before work, after 2 hours of work and after 8 hours of work ( p < 0.001). The mean recovery heart rate after 1 min was 88.0 ± 12.0 beat per min. (bpm), indicating that there is no excessive physiological demand. Body temperature (36.8 ± 0.40°C) and average heart rate after 8 hours (78 ± 12 bpm) indicated a good body control of heat exposure. Five out of six workplaces monitored had temperatures of greater than 28°C (ACGIH TLV). The workers were exposed to moderate heat stress during the study period, however, body temperature and average heart rate measurement did not reach unacceptable level of physiologic strain.
    Matched MeSH terms: Thermometers