Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Alwi HA, Carey JR, Smith BV
    J Acoust Soc Am, 2000 Mar;107(3):1363-73.
    PMID: 10738791
    The chirp response of a thickness-drive tunable transducer for wide range time-bandwidth and sweep rates chirp signals is demonstrated experimentally and computationally. The computational evaluation uses recursive digital-filter model based on the z-transform method. The model is limited to simple lossless structure with no front and backing layers. The model and experimental results show that there is no limit on the maximum sweep rate of the chirp signal but practically the limit is determined by the limitation of the circuit that generates the control voltage that simulates a variable electric load.
    Matched MeSH terms: Transducers
  2. Ahmad KA, Rahman MFA, Zain KAM, Haron MN, Manaf AA
    Sensors (Basel), 2021 Aug 19;21(16).
    PMID: 34451023 DOI: 10.3390/s21165582
    In acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine-tuned to suit specific applications. The ability to design a PMUT with high receiving sensitivity and a wide bandwidth is crucial to allow a wide spectrum of transmitted frequencies to be efficiently received. This paper presents a novel structure involving a double flexural membrane with a fluidic backing layer based on an in-plane polarization mode to optimize both the receiving sensitivity and frequency bandwidth for medium-range underwater acoustic applications. In this structure, the membrane material and electrode configuration are optimized to produce good receiving sensitivity. Simultaneously, a fluidic backing layer is introduced into the double flexural membrane to increase the bandwidth. Several piezoelectric membrane materials and various electrode dimensions were simulated using finite element analysis (FEA) techniques to study the receiving performance of the proposed structure. The final structure was then fabricated based on the findings from the simulation work. The pulse-echo experimental method was used to characterize and verify the performance of the proposed device. The proposed structure was found to have an improved bandwidth of 56.6% with a receiving sensitivity of -1.8864 dB rel 1 V µPa. For the proposed device, the resonance frequency and center frequency were 600 and 662.5 kHz, respectively, indicating its suitability for the targeted frequency range.
    Matched MeSH terms: Transducers*
  3. Hanif M, Jeoti V, Ahmad MR, Aslam MZ, Qureshi S, Stojanovic G
    Sensors (Basel), 2021 Nov 26;21(23).
    PMID: 34883867 DOI: 10.3390/s21237863
    Lately, wearable applications featuring photonic on-chip sensors are on the rise. Among many ways of controlling and/or modulating, the acousto-optic technique is seen to be a popular technique. This paper undertakes the study of different multilayer structures that can be fabricated for realizing an acousto-optic device, the objective being to obtain a high acousto-optic figure of merit (AOFM). By varying the thicknesses of the layers of these materials, several properties are discussed. The study shows that the multilayer thin film structure-based devices can give a high value of electromechanical coupling coefficient (k2) and a high AOFM as compared to the bulk piezoelectric/optical materials. The study is conducted to find the optimal normalised thickness of the multilayer structures with a material possessing the best optical and piezoelectric properties for fabricating acousto-optic devices. Based on simulations and studies of SAW propagation characteristics such as the electromechanical coupling coefficient (k2) and phase velocity (v), the acousto-optic figure of merit is calculated. The maximum value of the acousto-optic figure of merit achieved is higher than the AOFM of all the individual materials used in these layer structures. The suggested SAW device has potential application in wearable and small footprint acousto-optic devices and gives better results than those made with bulk piezoelectric materials.
    Matched MeSH terms: Transducers*
  4. MohdIsa W, Hunt A, HosseinNia SH
    Sensors (Basel), 2019 Sep 14;19(18).
    PMID: 31540032 DOI: 10.3390/s19183967
    Ionic polymer-metal composites (IPMC) are smart material transducers that bend in response to low-voltage stimuli and generate voltage in response to bending. IPMCs are mechanically compliant, simple in construction, and easy to cut into desired shape. This allows the designing of novel sensing and actuation systems, e.g., for soft and bio-inspired robotics. IPMC sensing can be implemented in multiple ways, resulting in significantly different sensing characteristics. This paper will review the methods and research efforts to use IPMCs as deformation sensors. We will address efforts to model the IPMC sensing phenomenon, and implementation and characteristics of different IPMC sensing methods. Proposed sensing methods are divided into active sensing, passive sensing, and self-sensing actuation (SSA), whereas the active sensing methods measure one of IPMC-generated voltage, charge, or current; passive methods measure variations in IPMC impedances, or use it in capacitive sensor element circuit, and SSA methods implement simultaneous sensing and actuation on the same IPMC sample. Frequency ranges for reliable sensing vary among the methods, and no single method has been demonstrated to be effective for sensing in the full spectrum of IPMC actuation capabilities, i.e., from DC to ∼100 Hz. However, this limitation can be overcome by combining several sensing methods.
    Matched MeSH terms: Transducers
  5. Siti Nur Masturah Abdul Malek, Sayed Inayatullah Shah
    MyJurnal
    In ultrasound imaging there is compromise between the penetration of signal at certain depths into the object and image resolution as the ultrasound probe only can transmit single frequency signals in one transmission. Using curvilinear ultrasound probe with 2 to 5 MHz frequency bandwidth, this study investigated the use of multi-frequency imaging to enhance the quality of phantom images.
    Methods: Siemen Acuson X150 with curvilinear ultrasound transducer was used to scan the organs of interest (kidney, gallbladder and pancreas) of the ultrasound abdominal phantom. Different images at the different selected frequencies (2.5, 3.6 and 5.0 MHz) were created by fixing the position and the orientation of the transducer in each of the scanning process. Different-frequency images were generated and combined to produce composite (multi-frequency) image. Results: In this study, the quality of the composite image was evaluated based on signal-to noise ratio (SNR) and the obtained results were compared with the single frequency images. Besides, the comparison was also made in terms of overall image quality (noise and sharpness of organ outline) through perceived image quality analysis. Based on calculated SNR, the composite image of the kidney, gallbladder and pancreas recorded higher SNR value as compared to the single frequency images. However, through perceived image quality, most of the observers viewed that the quality of the composite image of the kidney, gallbladder and pancreas is poor as compared to the single frequency image. Conclusions: Image quality of ultrasound imaging is improved by combining multiple ultrasound frequency images into a single composite image. This is achieved as high SNR is obtained in the composite image. However, through perceived image quality, the overall image quality of the composite image was poor.
    Matched MeSH terms: Transducers
  6. Zakaria MN, Ensin EG, Awang MA, Salim R, Nik Othman NA, Rashid MFN
    Med J Malaysia, 2023 Dec;78(7):901-906.
    PMID: 38159926
    INTRODUCTION: The sensorineural acuity level (SAL) test was developed as an alternative assessment to estimate bone conduction (BC) thresholds in cases where masking problems occur in pure tone audiometry (PTA). Nevertheless, prior to its clinical application, the respective SAL normative data must be made available. As such, the present study was carried out to establish SAL normative data using an insert earphone and two different commercially available bone transducers. Additionally, to determine the effect of earphone type on SAL test results, it was also of interest to compare the present study's findings with those of a previous study (that used a headphone to derive SAL normative data).

    MATERIALS AND METHODS: In this repeated-measures study, 40 Malaysian adults (aged 19-26 years) with normal hearing bilaterally (based on PTA results) were enrolled. They then underwent the SAL test based on the recommended protocol by Jerger and Tillman (1960). The SAL normative data for each ear were obtained by calculating the differences between air conduction (AC) thresholds in quiet and AC thresholds in noise by means of insert earphone, B71 and B81 bone vibrators.

    RESULTS: The SAL normative values were comparable between the ears (p > 0.05), and the data were pooled for subsequent analyses (n = 80 ears). Relative to B81 bone transducer, B71 bone vibrator produced statistically higher SAL normative data at all frequencies (p < 0.05). The SAL normative values established by the present study were statistically lower than those of the previous study (that utilised headphones) at most of frequencies tested (p < 0.05).

    CONCLUSIONS: The SAL normative data produced by the two bone vibrators were significantly different. The SAL normative values were also affected by the type of earphone used. While conducting the SAL test on Malaysian patients, the information provided by this study can be useful to guide the respective clinicians in choosing the appropriate normative data.

    Matched MeSH terms: Transducers
  7. Farahani H, Wagiran R, Hamidon MN
    Sensors (Basel), 2014 Apr 30;14(5):7881-939.
    PMID: 24784036 DOI: 10.3390/s140507881
    Humidity measurement is one of the most significant issues in various areas of applications such as instrumentation, automated systems, agriculture, climatology and GIS. Numerous sorts of humidity sensors fabricated and developed for industrial and laboratory applications are reviewed and presented in this article. The survey frequently concentrates on the RH sensors based upon their organic and inorganic functional materials, e.g., porous ceramics (semiconductors), polymers, ceramic/polymer and electrolytes, as well as conduction mechanism and fabrication technologies. A significant aim of this review is to provide a distinct categorization pursuant to state of the art humidity sensor types, principles of work, sensing substances, transduction mechanisms, and production technologies. Furthermore, performance characteristics of the different humidity sensors such as electrical and statistical data will be detailed and gives an added value to the report. By comparison of overall prospects of the sensors it was revealed that there are still drawbacks as to efficiency of sensing elements and conduction values. The flexibility offered by thick film and thin film processes either in the preparation of materials or in the choice of shape and size of the sensor structure provides advantages over other technologies. These ceramic sensors show faster response than other types.
    Matched MeSH terms: Transducers*
  8. Islam MM, Islam MT, Faruque MR
    ScientificWorldJournal, 2013;2013:378420.
    PMID: 24385878 DOI: 10.1155/2013/378420
    The dual-band operation of a microstrip patch antenna on a Duroid 5870 substrate for Ku- and K-bands is presented. The fabrication of the proposed antenna is performed with slots and a Duroid 5870 dielectric substrate and is excited by a 50 Ω microstrip transmission line. A high-frequency structural simulator (HFSS) is used which is based on the finite element method (FEM) in this research. The measured impedance bandwidth (2 : 1 VSWR) achieved is 1.07 GHz (15.93 GHz-14.86 GHz) on the lower band and 0.94 GHz (20.67-19.73 GHz) on the upper band. A stable omnidirectional radiation pattern is observed in the operating frequency band. The proposed prototype antenna behavior is discussed in terms of the comparisons of the measured and simulated results.
    Matched MeSH terms: Transducers*
  9. Kamarudin MA, Sahamir SR, Datta RS, Long BD, Mohd Sabri MF, Mohd Said S
    ScientificWorldJournal, 2013;2013:713640.
    PMID: 24324378 DOI: 10.1155/2013/713640
    Thermoelectricity, by converting heat energy directly into useable electricity, offers a promising technology to convert heat from solar energy and to recover waste heat from industrial sectors and automobile exhausts. In recent years, most of the efforts have been done on improving the thermoelectric efficiency using different approaches, that is, nanostructuring, doping, molecular rattling, and nanocomposite formation. The applications of thermoelectric polymers at low temperatures, especially conducting polymers, have shown various advantages such as easy and low cost of fabrication, light weight, and flexibility. In this review, we will focus on exploring new types of polymers and the effects of different structures, concentrations, and molecular weight on thermoelectric properties. Various strategies to improve the performance of thermoelectric materials will be discussed. In addition, a discussion on the fabrication of thermoelectric devices, especially suited to polymers, will also be given. Finally, we provide the challenge and the future of thermoelectric polymers, especially thermoelectric hybrid model.
    Matched MeSH terms: Transducers*
  10. Alashrah S, Kandaiya S, Lum LS, Cheng SK
    Z Med Phys, 2013 Dec;23(4):270-8.
    PMID: 24113373 DOI: 10.1016/j.zemedi.2013.09.001
    One of the factors which influence the spatial resolution of a 2D detector array is the size of the single detector, another the transport of the secondary electrons from the walls into the measuring volume. In this study, the single ion chamber dose response function of an I'mRT MatriXX array was determined by comparison between slit beam dose profiles measured with the array and with EBT2 radiochromic film in a solid water-equivalent phantom at a shallow depth of 0.5cm and at a depth of 5cm beyond the depth dose maximum for a 6 MV photon beam. The dose response functions were obtained using two methods, the best fit method and the deconvolution method. At the shallow depth, a Lorentz function and at 5cm depth a Gaussian function, both with the same FWHM of 7.4mm within limits of uncertainty, were identified as the best suited dose response functions of the 4.5mm diameter single array chamber. These dose response functions were then tested on various dose profiles whose true shape had been determined with EBT2 film and with the IC03 ionization chamber. By convolving these with the Lorentz kernel (at shallow depth) and the Gaussian kernel (at 5cm depth) the signal profiles measured with the I'mRT MatriXX array were closely approximated. Thus, the convolution of TPS-calculated dose profiles with these dose response functions can minimize the differences between calculation and measurement which occur due to the limited spatial resolution of the I'mRT MatriXX detector.
    Matched MeSH terms: Transducers*
  11. Azlan CA, Ng KH, Anandan S, Nizam MS
    Australas Phys Eng Sci Med, 2006 Sep;29(3):278-80.
    PMID: 17058591
    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
    Matched MeSH terms: Transducers*
  12. Pua CH, Ahmad H, Harun SW, De La Rue RM
    Appl Opt, 2012 May 20;51(15):2772-7.
    PMID: 22614578 DOI: 10.1364/AO.51.002772
    The idea of applying a simple Fabry-Perot fiber laser (FPFL) set-up in a free-running condition as an acoustic sensing medium is proposed. Conventional optical microphone requires a stringently aligned diaphragm to mediate the acoustic impedance mismatch between air and silica fiber. Motivated by the difficulty of optical sensing of airborne acoustic waves, a new sensing method is proposed to sense acoustic waves without the assistance of a diaphragm as transducer. By studying the output power fluctuation of the FPFL, the operating bandwidth and sensitivity of the proposed sensing method are determined. The tunability of the resonant frequency from 5 kHz to 85 kHz allows sensing of acoustic waves in the range of 100 Hz to 100 kHz. Tuning of the resonant frequency can be performed by changing the optical pumping power from as low as 10 mW to 68.5 mW or higher.
    Matched MeSH terms: Transducers
  13. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH, Ahmed NM
    Appl Radiat Isot, 2021 Apr;170:109622.
    PMID: 33592486 DOI: 10.1016/j.apradiso.2021.109622
    This study compares the real-time dosimetric performance of a bpw34 photodiode (PD) and cold white light-emitting diodes (LEDs) based on diagnostic X-ray-induced signals. Signals were extracted when both the transducers were under identical exposure settings, including source-to-detector distance (SDD), tube voltage (kVp), and current-time product (mAs). The transducers were in a photovoltaic configuration, and black vinyl tape was applied on transducer active areas as a form of optical shielding. X-ray beam spectra and energies were simulated using Matlab-based Spektr functions. Transducer performance analysis was based on signal linearity to mAs and air kerma, and sensitivity dependence on absorbed dose, energy, and dose rate. Bpw34 PD and cold white LED output signals were 84.8% and 85.5% precise, respectively. PD signals were 94.7% linear to mAs, whereas LED signals were 91.9%. PD and LED signal linearity to dose coefficients were 0.9397 and 0.9128, respectively. Both transducers exhibited similar dose and energy dependence. However, cold white LEDs were 0.73% less dose rate dependent than the bpw34 PD. Cold white LEDs demonstrated potential in detecting diagnostic X-rays because their performance was similar to that of the bpw34 PD. Moreover, the cold white LED array's dosimetric response was independent of the heel effect. Although cold white LED signals were lower than bpw34 PD signals, they were quantifiable and electronically amplifiable.
    Matched MeSH terms: Transducers
  14. Rifai D, Abdalla AN, Razali R, Ali K, Faraj MA
    Sensors (Basel), 2017 Mar 13;17(3).
    PMID: 28335399 DOI: 10.3390/s17030579
    The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient.
    Matched MeSH terms: Transducers
  15. Ahmad M, Roy RA, Kamarudin AG
    Int Endod J, 1994 Jan;27(1):26-31.
    PMID: 7806408
    The present study was undertaken to see if there was any variability in the power output of Piezon-Master 400 ultrasonic files when driven using different generators, tranducers and file holders. The displacement amplitude of the oscillating tip of the file in air was used as a measure of the power output. The results showed that there was considerable variability in the power output of Piezon-Master 400 ultrasonic files of similar size and length when driven using different generators, transducers and file holders. In consideration of this, it is recommended that a calibration device be incorporated in the ultrasonic unit so that the operator will have some knowledge of when the unit is working at its maximum efficiency.
    Matched MeSH terms: Transducers
  16. Ahmad M, Roy RA, Kamarudin AG, Safar M
    Int Endod J, 1993 Mar;26(2):120-4.
    PMID: 8330934
    The pattern of oscillation of a Piezon-Master 400 ultrasonic file driven by a piezoelectric transducer was studied in air and on water. In addition, the displacement amplitudes of the files were measured. The findings were compared with those observed with the Cavi-Endo unit reported in another study (Ahmad 1969). It was observed that the file vibrated such that a standing wave was formed on the file and it exhibited points of maximum deflection (antinode) and points of minimum deflection (node) with the largest deflection occurring at the apical end. This pattern of oscillation was similar to that exhibited by the Cavi-Endo file which employed a magnetostrictive transducer. However, the displacement amplitudes were very much higher than those exhibited by the Cavi-Endo. It is considered that the 120 degrees angle of the file holder inherent in the Piezon-Master 400 unit and the more effective power transmission with the piezoelectric transducer may have contributed to the large amplitudes.
    Matched MeSH terms: Transducers
  17. Tan MK, Siddiqi A, Yeo LY
    Sci Rep, 2017 07 27;7(1):6652.
    PMID: 28751783 DOI: 10.1038/s41598-017-07025-x
    The Miniaturised Lab-on-a-Disc (miniLOAD) platform, which utilises surface acoustic waves (SAWs) to drive the rotation of thin millimeter-scale discs on which microchannels can be fabricated and hence microfluidic operations can be performed, offers the possibility of miniaturising its larger counterpart, the Lab-on-a-CD, for true portability in point-of-care applications. A significant limitation of the original miniLOAD concept, however, is that it does not allow for flexible control over the disc rotation direction and speed without manual adjustment of the disc's position, or the use of multiple devices to alter the SAW frequency. In this work, we demonstrate the possibility of achieving such control with the use of tapered interdigitated transducers to confine a SAW beam such that the localised acoustic streaming it generates imparts a force, through hydrodynamic shear, at a specific location on the disc. Varying the torque that arises as a consequence by altering the input frequency to the transducers then allows the rotational velocity and direction of the disc to be controlled with ease. We derive a simple predictive model to illustrate the principle by which this occurs, which we find agrees well with the experimental measurements.
    Matched MeSH terms: Transducers
  18. Sayed, Inayatullah Shah
    MyJurnal
    Allah (s.w.t) has created innumerable distinct creatures and mentioned to us about their special qualities through His revelation. The Qur’an is the ultimate source of guidance for its followers for all aspects of life including science. If one is to study nature scientifically there are countless observable facts that are parallel to the teachings of Islam. One of these facts is echolocation found in bats and dolphins. These animals generate ultrasonic signals and detect the echoes reflected back to them to map out their environment and catch prey. Modern health sciences have already adopted this phenomenon in the form of ultrasound imaging for diagnosis of certain diseases. However, there is room for improvement in the overall performance of this technique. This article highlights the technological developments directly inspired by nature i.e., crawfish/crayfish and relates echolocation characteristics of bats and dolphins with basic principles of ultrasound imaging. In-depth studies on the echolocation properties of these creatures can lead to further improvement in the current ultrasound imaging technique. Such as; the construction of a transducer which simultaneously generates multi-frequency ultrasound signals and development of new interpreting software. Moreover, reading verses of the Holy Qur’an heartily and enthusiastically will lead to the development of innovative ideas that can be translated into reality and applied for the betterment of humankind.
    Matched MeSH terms: Transducers
  19. Ahsan MR, Islam MT, Habib Ullah M, Mahadi WN, Latef TA
    ScientificWorldJournal, 2014;2014:909854.
    PMID: 25165750 DOI: 10.1155/2014/909854
    This paper presents a compact sized inset-fed rectangular microstrip patch antenna embedded with double-P slots. The proposed antenna has been designed and fabricated on ceramic-PTFE composite material substrate of high dielectric constant value. The measurement results from the fabricated prototype of the antenna show -10 dB reflection coefficient bandwidths of 200 MHz and 300 MHz with center resonant frequency of 1.5 GHz and 4 GHz, respectively. The fabricated antenna has attained gains of 3.52 dBi with 81% radiation efficiency and 5.72 dBi with 87% radiation efficiency for lower band and upper band, respectively. The measured E- and H-plane radiation patterns are also presented for better understanding. Good agreement between the simulation and measurement results and consistent radiation patterns make the proposed antenna suitable for GPS and C-band applications.
    Matched MeSH terms: Transducers*
  20. Islam NN, Hannan MA, Shareef H, Mohamed A, Salam MA
    ScientificWorldJournal, 2014;2014:549094.
    PMID: 24977210 DOI: 10.1155/2014/549094
    Power oscillation damping controller is designed in linearized model with heuristic optimization techniques. Selection of the objective function is very crucial for damping controller design by optimization algorithms. In this research, comparative analysis has been carried out to evaluate the effectiveness of popular objective functions used in power system oscillation damping. Two-stage lead-lag damping controller by means of power system stabilizers is optimized using differential search algorithm for different objective functions. Linearized model simulations are performed to compare the dominant mode's performance and then the nonlinear model is continued to evaluate the damping performance over power system oscillations. All the simulations are conducted in two-area four-machine power system to bring a detailed analysis. Investigated results proved that multiobjective D-shaped function is an effective objective function in terms of moving unstable and lightly damped electromechanical modes into stable region. Thus, D-shape function ultimately improves overall system damping and concurrently enhances power system reliability.
    Matched MeSH terms: Transducers*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links