Displaying all 20 publications

Abstract:
Sort:
  1. Kamil N, Hisham AN, Abdullah M, Khairullah A
    Med J Malaysia, 1993 Sep;48(3):373-6.
    PMID: 8183157
    Fracture of the penis is not an uncommon urological emergency. Six patients with this injury, treated at the Institute of Urology, General Hospital, Kuala Lumpur, since 1988, were reviewed. Their ages ranged from 21 to 30 years old (mean 25). Four cases were self-inflicted by abnormal bending and 2 cases occurred during sexual intercourse. A sudden "cracking sound", violent pain, rapid flaccidity and deformity of the penis were documented. Duration of injury at presentation ranged from 12 to 90 hours (mean 35 hours). Primary repair of the tunica albuginea with absorbable suture was performed in all cases. The results of surgery was excellent, with restoration of normal function in 4 patients (2 patients defaulted follow-up). We advocate immediate surgical repair for this injury.
    Matched MeSH terms: Fractures, Bone/surgery*
  2. Afshar R, Fong TS, Latifi MH, Kanthan SR, Kamarul T
    J Hand Surg Eur Vol, 2012 Jun;37(5):396-401.
    PMID: 22019989 DOI: 10.1177/1753193411424557
    The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse midshaft osteotomies were created in 20 metacarpals harvested from three cadavers. Fractures were stabilised using 2.0 mm mini fragment plates fixed with either bicortical or unicortical screw fixation. These fixations were tested to failure with a three-point bending cyclic loading protocol using an electromechanical microtester and a 1 kN load cell. The mean load to failure was 370 N (SD 116) for unicortical fixation and 450 N (SD 135) for bicortical fixation. Significant differences between these two constructs were observed. A biomechanical advantage was found when using bicortical screws in metacarpal fracture plating.
    Matched MeSH terms: Fractures, Bone/surgery*
  3. Abdul-Rahman MR, Seong NK, Hee TG, Aljada ME, Reda TA, Sumin JO, et al.
    Heart Surg Forum, 2009 Jun;12(3):E184-6.
    PMID: 19546075 DOI: 10.1532/HSF98.20091016
    Various techniques of sternal stabilization via either metal plates or wires have been described. We describe an alternative technique of simple median sternotomy followed by reduction and wire fixation of the sternal fracture. The 2 patients described in this report had traumatic comminuted and displaced sternal fractures. Even though wire repair was deemed to be tedious and achieved poor approximation of the bone, we performed median sternotomy and achieved simple wire fixation with an excellent result.
    Matched MeSH terms: Fractures, Bone/surgery*
  4. Loke WP, Shukur MH, Yeap JK
    Med J Malaysia, 2006 Feb;61 Suppl A:40-4.
    PMID: 17042228
    Displaced humeral condyle fractures in children are traditionally fixed with smooth Kirschner wire at the expense of a risk of secondary displacement following removal of wire. Screw fixation of such fractures has recently been advocated as it provides stable fixation. We have been using screw osteosynthesis for treatment of displaced lateral humeral condyle fractures in children in our institution since the turn of this century. This study provides a midterm review of treatment of such injuries with special regards to growth disturbances after screw osteosynthesis and to assess rate of union with a view to formulate guidelines for screw removal. We review the outcomes of screw osteosynthesis for displaced lateral condyle fracture of the humerus (19 Milch type-1 and 15 Milch type-II) in 34 children treated in our institution from January 2000 to March 2004. The average age of the patients was 6.1 years. The average follow up was 24.5 months. Screw osteosynthesis led to union (average 6.9 weeks) in all patients with excellent results in 28 patients. Growth disturbances in the form of lateral condyle overgrowth (2 patients), valgus deformity secondary to lateral condyle avascular necrosis (2 patients) and fishtail deformity ((3 patients) were recognized. The implants should not be removed until fracture union is established. Screw osteosynthesis of the lateral humeral condyle fracture prevents secondary fracture redisplacement and lateral condyle overgrowth is probably related to hyperemic response to metaphyseal fixation and early removal of implant before radiological union.
    Matched MeSH terms: Fractures, Bone/surgery
  5. Shanmugam R, Ernst M, Stoffel K, Fischer MF, Wahl D, Richards RG, et al.
    Clin Biomech (Bristol, Avon), 2015 Jun;30(5):405-10.
    PMID: 25846324 DOI: 10.1016/j.clinbiomech.2015.03.019
    Dorsal plating is commonly used in proximal phalanx fractures but it bears the risk of interfering with the extensor apparatus. In this study, dorsal and lateral plating fixation methods are compared to assess biomechanical differences using conventional 1.5mm non-locking plates and novel 1.3mm lateral locking plates.
    Matched MeSH terms: Fractures, Bone/surgery*
  6. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2001 Jun;56 Suppl C:73-5.
    PMID: 11814255
    A case of late reconstruction of the patellar tendon is reported. Besides partial loss of the tendon, the patient also had loss of the distal third of the patella. A rolled strip of fascia lata was used to reconstruct the tendon with tunnels through the patella. At the tenth month of follow-up, the result was deemed successful.
    Matched MeSH terms: Fractures, Bone/surgery*
  7. Tee SS, Hyzan Y, Razak M
    Med J Malaysia, 2000 Sep;55 Suppl C:49-58.
    PMID: 11200045
    Between January 1996 and August 1998, 15 patients with pelvic ring injuries were treated by open reduction and internal fixation. Fractures types included Tile A1 (7%), B1 (33%), C1 (53%) and C3 (7%). The patients were observed for an average of 1 year (range: 5 to 21 months). Thirteen patients (87%) who were operated within 3 weeks after injury had their pelvic disruption healed. One patient with Tile C1 and non-union of the fracture dislocation of sacroiliac joint was operated 11 months after injury and developed implant failure and non-union of the fracture dislocation of sacroiliac joint. Another patient with Tile C1 injury with transforamina sacral fracture was fixed anteriorly only and developed non-union of the sacral fracture and redisplacement of pelvic disruption. Both of them had a poor functional outcome. A 40 points pelvic outcome grading scale (Cole et al 1996) based on physical examination, pain, radiographic analysis and activity/work status was used. Six patients (40%) (1 Tile A1, 5 Tile B1) had an excellent functional outcome. Seven patients (47%) (6 Tile C1, 1 Tile C3) had a good functional outcome.
    Matched MeSH terms: Fractures, Bone/surgery*
  8. Devnani AS
    PMID: 15685053
    In children with delayed presentation of displaced supracondylar fractures, closed or open reduction with K-wire fixation risks complications. Gradually reducing the fracture with traction potentially reduces these risks. An unacceptable deformity can be corrected later by an osteotomy. This concept was used for 28 children, with an average age of 7 years 6 months, who presented after an average delay of 5.6 days. Their stay in the hospital was 14 days on average. At followup (average, 24 months), five children (18%) who had cubitus varus greater than 10 degrees had corrective osteotomy. There were no additional neurovascular injuries after treatment. The results are comparable with other methods of treatment.
    Matched MeSH terms: Fractures, Bone/surgery*
  9. Park KS, Chan CK, Lee GW, Ahn HW, Yoon TR
    Injury, 2017 Feb;48(2):388-393.
    PMID: 27914663 DOI: 10.1016/j.injury.2016.11.029
    INTRODUCTION: Anatomical reduction of displaced acetabular fracture is not without its' limitations and complications. This study is conducted to assess clinical and radiological outcomes as well as complications of treating displaced acetabular fractures with emphasis on anatomical reduction in weight-bearing area, mainly the posterior column, and imperfect reduction of the anterior column is acceptable. However, stability of both columns is mandatory.

    METHODS: It was a retrospective study carried out in a Level 1 arthroplasty and trauma centre. 23 patients (17 males, 6 females) with average age of 50.1 years (range, 36-68 years) with displaced acetabular fracture treated with combined incisions and plate-cable systems were included. There were 3 elementary and 18 associated fractures according to Letournel classification. Average follow-up was 23.5 months (range, 12-38.7 months). Mean operation time was 160min (range: 75-320min). Functional scores were evaluated using Harris Hip Score (HHS) whilst reduction was assessed by Matta criteria. Any displacement of reduction, osteoarthritis, heterotopic ossification, and other complications was recorded.

    RESULT: 65.2% (15/23) of the patients obtained excellent HHS and 21.7% (5/23) had good HHS. There were 12 anatomical, 6 imperfect, and 5 poor reductions. No displacement was recorded in final follow-up. Complications documented: three lateral femoral cutaneous nerve injuries, two conversions to total hip arthroplasty, three Brooker stage 1 heterotrophic ossification, one pulmonary embolism and one screw irritation. No incidence of wound breakdown, infection and radiological osteoarthritis was reported.

    CONCLUSIONS: Imperfect reduction of the anterior column provided clinical outcomes that are as good as total anatomical reduction. This approach minimizes soft tissue damage and reduces perioperative morbidities.

    Matched MeSH terms: Fractures, Bone/surgery*
  10. Shanmugam R, Jian CYCCS, Haseeb A, Aik S
    J Orthop Surg (Hong Kong), 2018 10 3;26(3):2309499018802511.
    PMID: 30270746 DOI: 10.1177/2309499018802511
    PURPOSE: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion.

    METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.

    RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.

    CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.

    Matched MeSH terms: Fractures, Bone/surgery*
  11. Bajuri MY, Johan RR, Shukur H
    BMJ Case Rep, 2013;2013.
    PMID: 23576653 DOI: 10.1136/bcr-2013-008631
    Fat embolism syndrome (FES) is a continuum of fat emboli. Variants of FES: acute fulminant form and classic FES are postulated to represent two different pathomechanisms. Acute fulminant FES occurs during the first 24 h. It is attributed to massive mechanical blockage pulmonary vasculature by the fat emboli. The classic FES typically has a latency period of 24-36 h manifestation of respiratory failure and other signs of fat embolism. Progression of asymptomatic fat embolism with FES frequently represents inadequate treatment of hypovolaemic shock. We present a rare case of two variants of FES evolving in a patient with multiple fractures to emphasis the importance of adequate and appropriate treatment of shock in preventing the development of FES. Since supportive therapy which is a ventilatory support remains as the treatment of FES, it is appropriate to treat FES in the intensive care unit setting.
    Matched MeSH terms: Fractures, Bone/surgery
  12. Bajuri MY, Johan RR, Bahari SI
    BMJ Case Rep, 2013;2013.
    PMID: 23329712 DOI: 10.1136/bcr-2012-007697
    Chronic neglected subtalar dislocation associated with a non-union talar neck fracture is rare and never documented before. The lack of information from the literature on the optimal management prompted us to describe our experience in the management of this condition. We reported a case of a 57-year-old women presented with this injury. A satisfactory outcome was obtained using a tibio-talo-calcaneal arthrodesis through a plantar approach.
    Matched MeSH terms: Fractures, Bone/surgery
  13. Labens R, Khairuddin NH, Murray M, Jermyn K, Ahmad RS
    Vet Surg, 2019 Jan;48(1):96-104.
    PMID: 30403407 DOI: 10.1111/vsu.13123
    OBJECTIVE: To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

    STUDY DESIGN: Experimental.

    SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.

    METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

    RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear  = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded  = .003; Ploaded  

    Matched MeSH terms: Fractures, Bone/surgery
  14. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Fractures, Bone/surgery
  15. Miswan MF, Singh VA, Yasin NF
    Ulus Travma Acil Cerrahi Derg, 2011 Nov;17(6):504-8.
    PMID: 22290002 DOI: 10.5505/tjtes.2011.04809
    We reviewed cases with Lisfranc injuries who presented to our center in order to study the adequacy of the treatment method and their final functional outcome.
    Matched MeSH terms: Fractures, Bone/surgery
  16. Wan Hazmy CH, Maizuliana SH, Mastura MT, Norazlina M
    Med J Malaysia, 2006 Feb;61 Suppl A:45-9.
    PMID: 17042229
    Adequate pain relief is a requisite for a successful closed manipulative reduction (CMR) of fractures and dislocations. This prospective study was undertaken to assess the mode and adequacy of pain relief given to patients undergoing such procedures at Seremban Hospital from the 1st April to the 31st May 2001. All patients with fractures and dislocations scheduled to undergo CMR were included in this study. The type of sedative agents and analgesia administered were recorded. Demographic data and the type of fracture or dislocation of the selected patients were documented. A visual analogue scale (VAS) for pain perception was given to both to the patients and the medical personnel who performed the procedure. All data were collected manually before entered into computerized database for analysis. Of 72 patients included in this study, 47% were Malay, 26% Indian, 21% Chinese and 6% others. There was male predominance and the patients' age ranged between 9 to 79 years (average 27.4 years). Upper limb injuries (79%) were mainly fractures of the radius and ulna (29%) and isolated fracture radius (21%). For the lower limb injuries (21%), combined tibia and fibula fractures constituted 10% of the total cases followed by isolated tibia fractures (10%) and hip dislocation (1%). The most common pain relieving agents given during the CMR were intravenous pethidine alone (43%) followed by combination of intravenous pethidine and valium (36%), intramuscular pethidine (17%) and intramuscular tramal (4%). The Visual Analogue Score (VAS) for pain perception revealed that 61% of the patients had moderate pain while 21% had severe pain during the course of the procedures. Suboptimal pain relief administered during CMR should prompt positive actions to ensure that the patient is not subjected to undue pain just for the sake of an acceptable fracture reduction.
    Matched MeSH terms: Fractures, Bone/surgery*
  17. Saw A, Chan CK, Penafort R, Sengupta S
    Med J Malaysia, 2006 Feb;61 Suppl A:62-5.
    PMID: 17042233
    Patients treated with external fixation for limb reconsturciton or fracture stabilization equire regular and prolongedperiod of pin-tract care involving frequent visits to clinic and dressing traditionally carried out by trained nurses or medical assistants. A simple method of do-it-yourself dressing was introduced in our institution and this study was undertaken to evaluate the effectiveness of the protocol. Sixty patients (40 trauma-related problems and 20 congenital or developmental disorders) were enrolled into the study. Following application of external fixation, the patients and/or their caretakers were taught on how to do pin-site dressing using normal saline or drinking water as cleansing solution on daily basis. Patients were discharged on the second or third post-operative day and were followed-up every two weeks for an average 182 days (range 66 to 379 days) with special attention on identifying pin-tract infection. A simple grading system for pin-tract infections was proposed. Of 40 patients with trauma-related problems. 65% were post-traumatic infections. There were 788 metal-skin interfaces (239 half-pin fixations and 549 tensioned wire fixations. A total 143 metal-skin interface infections (18.1%) involving half-pin sites (41.3%) and tensioned wire sites (58.7%) was noted. Majority were grade I infections (79.7%), 18.8% grade II and only 1.4% grade III. Most infections (81%)were caused by Staphylococcus aureus. Grade I infections were successfully treated with frequent dressing, grade II by adjunctive oral antibiotic but grade III infections required removal of fixator. All eventually healed. Do yourself non-sterile dressing of metal-skin interfaces is a cost-effective method of pin-site care with a low infection rate. The infections were sucessfully treated using guidelines according to the proposed classification of pin-tract infections.
    Matched MeSH terms: Fractures, Bone/surgery*
  18. Ahmad AA, Ubaidah Mustapa Kamal MA, Ruslan SR, Abdullah S, Ahmad AR
    J Shoulder Elbow Surg, 2020 Nov;29(11):2319-2325.
    PMID: 32499198 DOI: 10.1016/j.jse.2020.03.003
    BACKGROUND: Fixation of clavicle fractures has now become a more popular option as it provides better outcome compared with conservative management. Wide-awake local anesthesia no tourniquet (WALANT) has been effectively used in plating of distal radius and olecranon fractures. This paper expands the usage of WALANT into the shoulder girdle, namely plating of the clavicle that has not been described. The operation is typically performed under general anesthesia.

    METHODS: We report a case series of 16 patients who successfully underwent fixation of the clavicle under the wide-awake technique. The clavicle fractures were grouped under the AO Fracture Classification. The WALANT solution comprised 1% lidocaine, 1:100,000 epinephrine, and 10:1 sodium bicarbonate. A total of 40 mL was injected in each patient with 10 mL subcutaneously along the clavicle followed by 30 mL subperiosteally at multiple intervals and directions.

    RESULTS: The Numerical Pain Rating Score was 0 during WALANT injection and during surgery except for 2 patients with Numerical Pain Rating Scores of 1 and 2, respectively, during reduction.

    CONCLUSION: We conclude that clavicle plating under WALANT is a good alternative option of anesthesia.

    Matched MeSH terms: Fractures, Bone/surgery*
  19. Iqbal QM
    Int Surg, 1974 Aug;59(8):410-5.
    PMID: 4853031
    Matched MeSH terms: Fractures, Bone/surgery
  20. Yeap EJ, Rao J, Pan CH, Soelar SA, Younger ASE
    Foot Ankle Surg, 2016 Sep;22(3):164-169.
    PMID: 27502224 DOI: 10.1016/j.fas.2015.06.008
    BACKGROUND: This study compares the outcomes of calcaneal fracture surgery after open reduction internal fixation and plating (ORIF) versus arthroscopic assisted percutaneous screw fixation (APSF).

    METHODS: Group I (N=12) underwent ORIF. Group II (N=15) underwent APSF. Anthropometric data, pre and post-operative stay, complications and duration off work were recorded in this retrospective case cohort study. Radiographs were analyzed for Bohler's, Gissane's angle and Sanders' classification. AOFAS Hindfoot and SF 36 scores were collected at final follow-up.

    RESULTS: Anthropometric data, Bohler's and Gissane's angles, AOFAS and SF 36 scores were not significantly different. Pre-operative duration was 12.3 days in ORIF and 6.9 days in APSF. Post-operative duration was 7.3 days vs 3.8 days. Duration off work was 6.2 months vs 2.9 months.

    CONCLUSION: The APSF group was able to have surgery earlier, go home faster, and return to work earlier. This study was not powered to demonstrate a difference in wound complication rates.

    Matched MeSH terms: Fractures, Bone/surgery
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links