Displaying all 8 publications

Abstract:
Sort:
  1. Sulaiman AS, Nordin S
    Med J Malaysia, 2005 Jul;60 Suppl C:41-4.
    PMID: 16381282
    Patellar thickness is an important consideration for resurfacing in total knee arthroplasty. A patella of 25 mm in thickness is not suitable for resurfacing using the currently available total knee systems. A cross sectional study on patellar thickness using plain radiographs was undertaken on 56 patients. It was observed that the average thickness of the bony part of the patella was 20.05 mm (range 17-23 mm). The actual thickness of cartilage varies from 2.0 to 5.5 mm (mean 3.2 mm). Thus the mean thickness of the patella was 23.2 mm (range 20.2-26.2 mm). The majority of our patients (73%) had patellar thickness of 24 mm or less. The patellar thickness had a significant correlation with the patient's height (R=0.5). Since the majority of our patients have thin patella, we are of the opinion that majority of our patients are not suitable for patellar resurfacing.
    Matched MeSH terms: Patella/surgery
  2. Aithal Padur A, Kumar N, Lewis MG, Sekaran VC
    Surg Radiol Anat, 2021 Dec;43(12):2039-2046.
    PMID: 34570285 DOI: 10.1007/s00276-021-02837-z
    PURPOSE: Morphometric analysis of the patella and the patellar ligament is crucial in diagnosing and surgical corrections of knee injuries and patellofemoral joint disorders. Dimensions of the patella and the patellar ligament are frequently used in implant design and ACL reconstruction. This study aims to obtain detailed morphometric data on the patellar ligament and its localization based on gross anatomical dissections in the adult cadavers.

    METHODS: The present study consisted of 50 lower limbs from formalin-fixed male adult cadavers aged about 70 years (45-85) belonging to the South Indian population. Total length of the quadriceps tendon, patellar height, patellar ligament height, proximal width, distal width and thickness of the patellar ligament were measured meticulously. Mean, standard deviation, median scores of each parameter were computed for groups using SPSS 16.0. Level of significance was considered as p patella and patellar ligament between the right and left lower limbs. Patellar ligament length showed positive correlation with ligament thickness (r = 0.36; p = 0.078 for right limb and r = 0.33; p = 0.104 for left limb). Proximal width of ligament showed significant positive correlation with distal width (r = 0.41; p = 0.041 for right limb and r = 0.54; p = 0.006 for left limb).

    CONCLUSION: This morphometric data and analysis might be fundamental in understanding various knee conditions in situ and necessary to orthopedic surgeons for successful planning and execution for ACL reconstruction using patellar ligament graft and other patellofemoral joint disorders.

    LEVEL OF EVIDENCE: I.

    Matched MeSH terms: Patella/surgery
  3. Poonnoose PM, Korula RJ, Oommen AT
    Med J Malaysia, 2005 Oct;60(4):511-3.
    PMID: 16570720
    Chronic ruptures of the extensor mechanism of the knee are uncommon injuries, and previously reported literature assumes the presence of an intact patella for repair. We present a case of chronic rupture following patellectomy done twelve years previously. The defect in the extensor apparatus was extensive (18cm), and this was bridged using a large fascia lata graft from the opposite thigh, with reasonably successful results.
    Matched MeSH terms: Patella/surgery*
  4. Merican AM, Ghosh KM, Baena FR, Deehan DJ, Amis AA
    Knee Surg Sports Traumatol Arthrosc, 2014 Mar;22(3):526-33.
    PMID: 23271038 DOI: 10.1007/s00167-012-2312-z
    PURPOSE: To study the effect of increasing patellar thickness (overstuffing) on patellofemoral kinematics in total knee arthroplasty and whether subsequent lateral retinacular release would restore the change in kinematics.

    METHODS: The quadriceps of eight fresh-frozen knees were loaded on a custom-made jig. Kinematic data were recorded using an optical tracking device for the native knee, following total knee arthroplasty (TKA), then with patellar thicknesses from -2 to +4 mm, during knee extension motion. Staged lateral retinacular releases were performed to examine the restoration of normal patellar kinematics.

    RESULTS: Compared to the native knee, TKA led to significant changes in patellofemoral kinematics, with significant increases in lateral shift, tilt and rotation. When patellar composite thickness was increased, the patella tilted further laterally. Lateral release partly corrected this lateral tilt but caused abnormal tibial external rotation. With complete release of the lateral retinaculum and capsule, the patella with an increased thickness of 4 mm remained more laterally tilted compared to the TKA with normal patellar thickness between 45° and 55° knee flexion and from 75° onwards. This was on average by 2.4° ± 2.9° (p patella was tilted laterally by 4.7° ± 3.2° and 5.4° ± 2.7° more than in the TKA with matched patellar thickness.

    CONCLUSION: Patellar thickness affects patellofemoral kinematics after TKA. Although lateral tilt was partly corrected by lateral retinacular release, this affected the tibiofemoral kinematics.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Patella/surgery*
  5. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2001 Jun;56 Suppl C:73-5.
    PMID: 11814255
    A case of late reconstruction of the patellar tendon is reported. Besides partial loss of the tendon, the patient also had loss of the distal third of the patella. A rolled strip of fascia lata was used to reconstruct the tendon with tunnels through the patella. At the tenth month of follow-up, the result was deemed successful.
    Matched MeSH terms: Patella/surgery*
  6. Tai CC, Cross MJ
    J Bone Joint Surg Br, 2006 Sep;88(9):1158-63.
    PMID: 16943464
    We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were = 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up.
    Matched MeSH terms: Patella/surgery
  7. Rasit AH, Sharaf I, Pan KL
    Med J Malaysia, 2004 Dec;59 Suppl F:52-3.
    PMID: 15941163
    Sleeve fracture of the inferior pole of the patella is a rare and distinctive fracture in children with few published reports. These fractures are frequently misdiagnosed and neglected. We highlight a case of a neglected and misdiagnosed sleeve fracture of the patella in an eleven-year-old boy. This was initially diagnosed as an avulsion fracture of the tibial tubercle. A good outcome was achieved after open reduction and internal fixation.
    Matched MeSH terms: Patella/surgery
  8. Sulaiman AR, Halim AS, Azman WS, Eskandar H
    Singapore Med J, 2008 Aug;49(8):e205-7.
    PMID: 18756334
    Post-traumatic severe patella infera and intra-articular adhesion may lead to a severe knee stiffness. We report a 29-year-old man, a muslim prayer leader, who had a previous knee injury. He presented with knee movement from ten degrees to 30 degrees, patellar infera with a length of patella to length of patellar tendon ratio of 2:5, and severe knee arthrofibrosis. He underwent incision of the patella ligament and open arthrofibrosis release, leaving a tendon gap and skin defect of 5 cm. Reconstruction was successfully done using a free vascularised composite tensor fascia lata flap. He regained full range of knee motion with normal strength quadriceps mechanism at five months after surgery, and remained in full function at 18 months follow-up.
    Matched MeSH terms: Patella/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links