A simple and rapid gas chromatography (GC) method with flame ionization detector was developed for detection of isopropyl para-toluenesulphonate (IPTS) in palm-based isopropyl palmitate (IPP) and isopropyl myristate (IPM). The method involved spiking the IPP/IPM samples with IPTS and directly injecting the spiked samples into GC without undergoing clean-up steps. The calibration curves for IPTS showed good linearity with coefficient correlation of 0.9999 for six-point calibration from 0.5 to 50 μg mL(-1) and 0.9996 for six-point calibration from 0.5 to 200 μg mL(-1) . IPTS recoveries from IPP were 98.6-103.5% with relative standard deviation (RSD) of 0.40-2.80%, whereas recoveries from IPM were 97.0-107.2% with RSD of 0.42-4.21%. The identity of IPTS recovered from the isopropyl esters was confirmed by a GC-mass spectrometer detector. The method was successfully applied to the analyses of IPTS in commercial samples. It was found that there were IPTS in the range of 34.8-1303.0 μg g(-1) in the palm-based esters for some of the samples analysed.