Displaying all 19 publications

Abstract:
Sort:
  1. Sanagi MM, Nasir Z, Ling SL, Hermawan D, Ibrahim WA, Naim AA
    J AOAC Int, 2010 10 7;93(4):1322-30.
    PMID: 20922968
    Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.
    Matched MeSH terms: Chromatography, Gas/methods*
  2. Farina Y, Abdullah MP, Bibi N, Khalik WM
    Food Chem, 2017 Jun 01;224:55-61.
    PMID: 28159293 DOI: 10.1016/j.foodchem.2016.11.113
    A simple and sensitive analytical method has been developed employing gas chromatography coupled with electron capture detector (GC-ECD), and validated for screening and quantification of 15 pesticide residues at trace levels in cabbage, broccoli, cauliflower, lettuce, celery, spinach, and mustard. The method consists of two steps, first, to determine the significance of each factor by Pareto chart followed by optimization of these significant factors using central composite design (CCD). Minitab statistical software was used for these multivariate experiments for the generation of 2(4-1) design and CCD matrices. The method evaluation was done by external standard calibration with linearity range between 0.5 and 3mg/kg, with correlation coefficient 0.99, limit of detection (LOD) ranges between 0.02 and 4.5ng/g, and limit of quantification (LOQ) ranges between 0.2 and 45ng/g. The average recovery was between 60% and 128%, with RSD 0.2-19.8%. The method was applied on real vegetable samples from Cameron Highlands.
    Matched MeSH terms: Chromatography, Gas/methods*
  3. Kulsing C, Nolvachai Y, Wong YF, Glouzman MI, Marriott PJ
    J Chromatogr A, 2018 Apr 20;1546:97-105.
    PMID: 29548566 DOI: 10.1016/j.chroma.2018.02.035
    Real-time interconversion processes produce unconventional peak broadening in gas chromatography (GC), and can be used to generate kinetic and thermodynamic data. In this study, an unusual separation situation in comprehensive two dimensional GC where two dimensional interconversion (i.e. a raised plateau in both first and second dimension, 1D and 2D) was observed in analysis of oxime isomers. This resulted in a characteristic and unusual rectangular peak shape in the two dimensional result. A related theoretical approach was introduced to explain the peak shape supported by simulation results which can be varied depending on concentration profiles and kinetics of the process. The simulated results were supported by experimental results obtained by a comprehensive heart-cut multidimensional GC (H/C MDGC) approach which was developed to clearly investigate isomerisation of E/Z oxime molecules in both 1D and 2D separations under different isothermal conditions. The carrier gas flow and oven temperature were selected according to initial results for 1D interconversion on a poly(ethyleneglycol) stationary phase, which was further used in both 1D and 2D separations to result in broad zones of oxime interconversion in both dimensions. The method involved repetitive injections of oxime sample, then sampling contiguous fractions of sample into a long 2D column which is intended to promote considerable interconversion. Comprehensiveness arises from the fact that the whole sample is sampled from the 1D to the 2D column, with the long 2D column replacing the short 2D column used in classical comprehensive two-dimensional gas chromatography, where the latter will not promote sufficient interconversion. Data processing and presentation permits a 'rectangular' distribution corresponding to the separated compounds, characteristic of this experiment.
    Matched MeSH terms: Chromatography, Gas/methods*
  4. Tay BY
    Int J Cosmet Sci, 2013 Feb;35(1):57-63.
    PMID: 22994145 DOI: 10.1111/ics.12004
    A simple and rapid gas chromatography (GC) method with flame ionization detector was developed for detection of isopropyl para-toluenesulphonate (IPTS) in palm-based isopropyl palmitate (IPP) and isopropyl myristate (IPM). The method involved spiking the IPP/IPM samples with IPTS and directly injecting the spiked samples into GC without undergoing clean-up steps. The calibration curves for IPTS showed good linearity with coefficient correlation of 0.9999 for six-point calibration from 0.5 to 50 μg mL(-1) and 0.9996 for six-point calibration from 0.5 to 200 μg mL(-1) . IPTS recoveries from IPP were 98.6-103.5% with relative standard deviation (RSD) of 0.40-2.80%, whereas recoveries from IPM were 97.0-107.2% with RSD of 0.42-4.21%. The identity of IPTS recovered from the isopropyl esters was confirmed by a GC-mass spectrometer detector. The method was successfully applied to the analyses of IPTS in commercial samples. It was found that there were IPTS in the range of 34.8-1303.0 μg g(-1) in the palm-based esters for some of the samples analysed.
    Matched MeSH terms: Chromatography, Gas/methods*
  5. Tan GH, Vijayaletchumy K
    Bull Environ Contam Toxicol, 1994 Sep;53(3):351-6.
    PMID: 7919710
    Matched MeSH terms: Chromatography, Gas/methods
  6. Myint S, Daud WR, Mohamad AB, Kadhum AA
    J Chromatogr B Biomed Appl, 1996 Apr 26;679(1-2):193-5.
    PMID: 8998560
    An ethanolic extract of cloves was analyzed by gas chromatography directly to identify eugenol and other major phenolic compounds without previous separation of other components. Separation was performed on a fused-silica capillary column of 30 m x 0.53 mm I.D., 0.53 microns film thickness. The detector was a flame ionization detector. Helium gas at a flow-rate of 3 ml/min was used as a carrier gas. The analysis were performed with linear temperature programming. Nine components were detected and special attention was given to the major phenolic compound, eugenol.
    Matched MeSH terms: Chromatography, Gas/methods
  7. Hajeb P, Jinap S, Abu Bakar F, Bakar J
    PMID: 19680957 DOI: 10.1080/02652030902751704
    Response surface methodology (RSM) was used to determine the optimum experimental conditions to extract methylmercury from fish samples for GC analysis. The influence of four variables - acid concentration (3-12 M), cysteine concentration (0.5-2% w/v), solvent volume (3-9 ml) and extraction time (10-30 min) - on recovery of methylmercury was evaluated. The detection limit for methylmercury analysis using a microelectron capture detector was 7 ng g(-1) in fish samples. The mean recovery under optimum conditions was 94%. Experimental data were adequately fitted into a second-order polynomial model with multiple regression coefficients (r(2)) of 0.977. The four variables had a significant effect (p < 0.05) on the recovery of methylmercury from a reference material (BCR-463). Optimum conditions for methylmercury extraction were found using an acid concentration of 12.2 M, cysteine concentration of 2.4%, solvent volume of 1.5 ml and extraction time of 35 min. The validation of the developed method to analyze methylmercury in fish samples exhibited good agreement with mercury content in the samples.
    Matched MeSH terms: Chromatography, Gas/methods
  8. Sharif Z, Man YB, Hamid NS, Keat CC
    J Chromatogr A, 2006 Sep 15;1127(1-2):254-61.
    PMID: 16857206
    A method to determine six organochlorine and three pyrethroid pesticides in grape, orange, tomato, carrot and green mustard based on solvent extraction followed by solid phase extraction (SPE) clean-up is described. The pesticides were spiked into the sample prior to analysis, extracted with ethyl acetate, evaporated and reconstituted with a solvent mixture of acetone:n-hexane (3:7). Three different sorbents (Strong Anion Exchanger/Primary Secondary Amine (SAX/PSA), Florisil and C18) were used for the clean-up step. Pesticides were eluted with 5mL of acetone:n-hexane (3:7, v/v) and determined by gas chromatography and electron-capture detection (GC-ECD). SAX/PSA was the sorbent, which provided chromatograms with less interference and the mean recoveries obtained were within 70-120% except for captafol. The captafol recoveries for grape were within acceptable range with C18 clean-up column.
    Matched MeSH terms: Chromatography, Gas/methods*
  9. Muhamad H, Zainudin BH, Abu Bakar NK
    Food Chem, 2012 Oct 15;134(4):2489-96.
    PMID: 23442715 DOI: 10.1016/j.foodchem.2012.04.095
    Solid phase extraction (SPE) and dispersive solid-phase extraction (d-SPE) were compared and evaluated for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with an electron capture detector (GC-ECD). Several SPE sorbents such as graphitised carbon black (GCB), primary secondary amine (PSA), C(18), silica, and florisil were tested in order to minimise fat residues. The results show that mixed sorbents using GCB and PSA obtained cleaner extracts than a single GCB and PSA sorbents. The average recoveries obtained for each pesticide ranged between 81% and 114% at five fortification levels with the relative standard deviation of less than 7% in all cases. The limits of detection for these pesticides were ranged between 0.025 and 0.05 μg/g. The proposed method was applied successfully for the residue determination of both λ-cyhalothrin and cypermethrin in crude palm oil samples obtained from local mills throughout Malaysia.
    Matched MeSH terms: Chromatography, Gas/methods
  10. Lau HL, Puah CW, Choo YM, Ma AN, Chuah CH
    Lipids, 2005 May;40(5):523-8.
    PMID: 16094863
    This paper discusses a rapid GC-FID technique for the simultaneous quantitative analysis of FFA, MAG, DAG, TAG, sterols, and squalene in vegetable oils, with special reference to palm oil. The FFA content determined had a lower SE compared with a conventional titrimetric method. Squalene and individual sterols, consisting of beta-sitosterol, stigmasterol, campesterol, and cholesterol, were accurately quantified without any losses. This was achieved through elimination of tedious conventional sample pretreatments, such as saponification and preparative TLC. With this technique, the separation of individual MAG, consisting of 16:0, 18:0, and 18:1 FA, and the DAG species, consisting of the 1,2(2,3)- and 1,3-positions, was sufficient to enable their quantification. This technique enabled the TAG to be determined according to their carbon numbers in the range of C44 to C56. Comparisons were made with conventional methods, and the results were in good agreement with those reported in the literature.
    Matched MeSH terms: Chromatography, Gas/methods*
  11. Kwan TK, Foong SL, Lim YT, Gower DB
    Biochem. Mol. Biol. Int., 1993 Nov;31(4):733-43.
    PMID: 8298502
    Using the rapid gas chromatographic steroid profiling technique, a number of metabolites of pregnenolone have been separated and quantified after incubation of this steroid with adult rat and neonatal porcine testicular homogenates. It was shown that the 5-ene-3 beta-hydroxy- and the 4-en-3-oxosteroid pathways for androgen biosynthesis were operating in both species, although the former pathway appeared to be more important in porcine testis. This tissue was characterised by the formation of several odorous, and pheromonal, 16-androstenes, which were quantitatively more important than the androgens. Three non-steroidal anti-inflammatory drugs (NSAIDS) caused dose-related inhibition of androgen and 16-androstene biosynthesis when co-incubated with pregnenolone. The order of potency was flurbiprofen > indomethacin > > > aspirin. The possibility that the NSAIDS may interfere with cytochrome P-450 is discussed, since several steroid-transforming enzymes, known to be dependent on this cytochrome for their activity, were markedly inhibited.
    Matched MeSH terms: Chromatography, Gas/methods
  12. Hassan H, Othman MF, Zakaria ZA, Saad FFA, Abdul Razak HR
    Curr Radiopharm, 2021;14(2):131-144.
    PMID: 33115398 DOI: 10.2174/1874471013999201027215704
    BACKGROUND: Organic solvents play an indispensable role in most of the radiopharmaceutical production stages. It is almost impossible to remove them entirely in the final formulation of the product.

    OBJECTIVE: In this presented work, an analytical method by gas chromatography coupled with flame ionization detection (GC-FID) has been developed to determine organic solvents in radiopharmaceutical samples. The effect of injection holding time, temperature variation in the injection port, and the column temperature on the analysis time and resolution (R ≥ 1.5) of ethanol and acetonitrile was studied extensively.

    METHODS: The experimental conditions were optimized with the aid of further statistical analysis; thence, the proposed method was validated following the International Council for Harmonisation (ICH) Q2 (R1) guideline.

    RESULTS: The proposed analytical method surpassed the acceptance criteria including the linearity > 0.990 (correlation coefficient of R2), precision < 2%, LOD, and LOQ, accuracy > 90% for all solvents. The separation between ethanol and acetonitrile was acceptable with a resolution R > 1.5. Further statistical analysis of Oneway ANOVA revealed that the increment in injection holding time and variation of temperature at the injection port did not significantly affect the analysis time. Nevertheless, the variation in injection port temperature substantially influenced the resolution of ethanol and acetonitrile peaks (p < 0.05).

    CONCLUSION: The proposed analytical method has been successfully implemented to determine the organic solvent in the [18F]fluoro-ethyl-tyrosine ([18F]FET), [18F]fluoromisonidazole ([18F]FMISO), and [18F]fluorothymidine ([18F]FLT).

    Matched MeSH terms: Chromatography, Gas/methods*
  13. Ismail A, Toriman ME, Juahir H, Kassim AM, Zain SM, Ahmad WKW, et al.
    Mar Pollut Bull, 2016 Oct 15;111(1-2):339-346.
    PMID: 27397593 DOI: 10.1016/j.marpolbul.2016.06.089
    Extended use of GC-FID and GC-MS in oil spill fingerprinting and matching is significantly important for oil classification from the oil spill sources collected from various areas of Peninsular Malaysia and Sabah (East Malaysia). Oil spill fingerprinting from GC-FID and GC-MS coupled with chemometric techniques (discriminant analysis and principal component analysis) is used as a diagnostic tool to classify the types of oil polluting the water. Clustering and discrimination of oil spill compounds in the water from the actual site of oil spill events are divided into four groups viz. diesel, Heavy Fuel Oil (HFO), Mixture Oil containing Light Fuel Oil (MOLFO) and Waste Oil (WO) according to the similarity of their intrinsic chemical properties. Principal component analysis (PCA) demonstrates that diesel, HFO, MOLFO and WO are types of oil or oil products from complex oil mixtures with a total variance of 85.34% and are identified with various anthropogenic activities related to either intentional releasing of oil or accidental discharge of oil into the environment. Our results show that the use of chemometric techniques is significant in providing independent validation for classifying the types of spilled oil in the investigation of oil spill pollution in Malaysia. This, in consequence would result in cost and time saving in identification of the oil spill sources.
    Matched MeSH terms: Chromatography, Gas/methods
  14. Miskam M, Abu Bakar NK, Mohamad S
    Talanta, 2014 Mar;120:450-5.
    PMID: 24468395 DOI: 10.1016/j.talanta.2013.12.037
    A solid phase extraction (SPE) method has been developed using a newly synthesized titanium (IV) butoxide-cyanopropyltriethoxysilane (Ti-CNPrTEOS) sorbent for polar selective extraction of aromatic amines in river water sample. The effect of different parameters on the extraction recovery was studied using the SPE method. The applicability of the sorbents for the extraction of polar aromatic amines by the SPE was extensively studied and evaluated as a function of pH, conditioning solvent, sample loading volume, elution solvent and elution solvent volume. The optimum experimental conditions were sample at pH 7, dichloromethane as conditioning solvent, 10 mL sample loading volume and 5 mL of acetonitrile as the eluting solvent. Under the optimum conditions, the limit of detection (LOD) and limit of quantification (LOQ) for solid phase extraction using Ti-CNPrTEOS SPE sorbent (0.01-0.2; 0.03-0.61 µg L(-1)) were lower compared with those achieved using Si-CN SPE sorbent (0.25-1.50; 1.96-3.59 µg L(-1)) and C18 SPE sorbent (0.37-0.98; 1.87-2.87 µg L(-1)) with higher selectivity towards the extraction of polar aromatic amines. The optimized procedure was successfully applied for the solid phase extraction method of selected aromatic amines in river water, waste water and tap water samples prior to the gas chromatography-flame ionization detector separation.
    Matched MeSH terms: Chromatography, Gas/methods
  15. Akmar ZD, Norhaizan ME, Azimah R, Azrina A, Chan YM
    Malays J Nutr, 2013 Apr;19(1):87-98.
    PMID: 24800387 MyJurnal
    INTRODUCTION: There is a lack of information on the trans fatty acid (TFA) content in Malaysian foods. The objective of this study is to determine the TFA content of bakery products, snacks, dairy products, fast foods, cooking oils and semisolid fats, and breakfast cereals and Malaysian fast foods. This study also estimated the quantity of each isomer in the foods assayed.
    METHODS: The trans fatty acid content of each food sample was assessed in duplicate by separating the fatty acid methyl esters (FAME) in a gas chromatography system equipped with HP-88 column (USA: split ratio 10: 1) for cis/trans separation. Five major TFA isomers, palmitoelaidic acid (16: 1t9), petroselaidic acid (18:1t6), elaidic acid (18:1t9), vaccenic acid (18: 1t11) and linoelaidic acid (18:2t9, 12), were measured using gas chromatography (GC) and the data were expressed in unit values of g/100 g lipid or g/100 g food.
    RESULTS: The total TFA contents in the studied foods were < 0.001 g-8.77 g/100 g lipid or < 0.001 g-5.79 g/100 g foods. This value falls within the standard and international recommendation level for TFA. The measured range of specific TFA isomers were as follows: palmitoelaidic acid (< 0.001 g-0.26 g/100 g lipid), petroselaidic acid (< 0.001 g - 3.09 g/100 g lipid), elaidic acid (< 0.001 g-0.87 g/100 g lipid), vaccenic acid (< 0.001 g-0.41 g/100 g lipid) and linoelaidic acid (< 0.001 g-6.60 g/100 g lipid).
    CONCLUSION: These data indicate that most of the tested foods have low TFA contents (< 1 g/100 g lipid).
    Matched MeSH terms: Chromatography, Gas/methods
  16. Chai M, Tan G, Lal A
    Anal Sci, 2008 Feb;24(2):273-6.
    PMID: 18270422
    A headspace solid-phase microextraction method has been developed for the determination of 8 pesticides in vegetables and fruits by using gas chromatography with an electron capture detector. Two types of fibers (polyacrylate, 85 microm and polydimethylsiloxane, 100 microm) have been assayed and compared. The main factors: extraction and desorption parameters, ionic strength, and the effects of dilution and organic solvents, were studied and optimized. The optimized procedures resulted in more than 80% recovery for all the investigated vegetable and fruit samples with RSD values below 10%.
    Matched MeSH terms: Chromatography, Gas/methods
  17. Lal A, Tan G, Chai M
    Anal Sci, 2008 Feb;24(2):231-6.
    PMID: 18270414
    A new extraction and cleanup procedure with gas chromatography was developed for the sensitive determination of acephate, dimethoate, malathion, diazinon, quinalphos, chlorpyrifos, profenofos, alpha-endosulfan, beta-endosulfan, chlorothalonil and carbaryl using 1-chloro-4-fluorobenzene as an internal standard in fruits and vegetables. Several extracting and eluting solvents for solid-phase extraction were investigated. The overall extracting solvent with a mixture of acetone:ethyl acetate:hexane (10:80:10, v/v/v) and a eluting solvent of 5% acetone in hexane used with the RPC18 cartridge gave the best recovery for all of the investigated pesticides, and minimized the interference from co-extractants. Under the optimal extraction and clean-up conditions, recoveries of 85 - 99% with RSD < 5.0% (n = 3) for most of the pesticides at the 0.02 - 0.5 mg/kg level were obtained. The limit of detection was between 0.005 - 0.01 mg/kg and the limit of quantification was 0.01 mg/kg. This analytical procedure was characterized with high accuracy and acceptable sensitivity to meet requirements for monitoring pesticides in crops.
    Matched MeSH terms: Chromatography, Gas/methods
  18. Hui BY, Raoov M, Zain NNM, Mohamad S, Osman H
    Crit Rev Anal Chem, 2017 Sep 03;47(5):454-467.
    PMID: 28453309 DOI: 10.1080/10408347.2017.1320936
    The growth in driving force and popularity of cyclodextrin (CDs) and ionic liquids (ILs) as promising materials in the field of analytical chemistry has resulted in an exponentially increase of their exploitation and production in analytical chemistry field. CDs belong to the family of cyclic oligosaccharides composing of α-(1,4) linked glucopyranose subunits and possess a cage-like supramolecular structure. This structure enables chemical reactions to proceed between interacting ions, radical or molecules in the absence of covalent bonds. Conversely, ILs are an ionic fluids comprising of only cation and anion often with immeasurable vapor pressure making them as green or designer solvent. The cooperative effect between CD and IL due to their fascinating properties, have nowadays contributed their footprints for a better development in analytical chemistry nowadays. This comprehensive review serves to give an overview on some of the recent studies and provides an analytical trend for the application of CDs with the combination of ILs that possess beneficial and remarkable effects in analytical chemistry including their use in various sample preparation techniques such as solid phase extraction, magnetic solid phase extraction, cloud point extraction, microextraction, and separation techniques which includes gas chromatography, high-performance liquid chromatography, capillary electrophoresis as well as applications of electrochemical sensors as electrode modifiers with references to recent applications. This review will highlight the nature of interactions and synergic effects between CDs, ILs, and analytes. It is hoped that this review will stimulate further research in analytical chemistry.
    Matched MeSH terms: Chromatography, Gas/methods
  19. Abboud AS, Sanagi MM, Ibrahim WAW, Keyon ASA, Aboul-Enein HY
    J Chromatogr Sci, 2018 Feb 01;56(2):177-186.
    PMID: 29186451 DOI: 10.1093/chromsci/bmx095
    In this study, caged calcium alginate-caged multiwalled carbon nanotubes dispersive microsolid phase extraction was described for the first time for the extraction of polycyclic aromatic hydrocarbons (PAHs) from water samples prior to gas chromatographic analysis. Fluorene, phenanthrene and fluoranthene were selected as model compounds. The caged calcium alginate-caged multiwalled carbon nanotubes was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy and thermal gravimetry analyses. The effective parameters namely desorption solvent, solvent volume, extraction time, desorption time, the mass of adsorbent and sample volume were optimized. Under the optimum extraction conditions, the developed method showed good linearity in the range of 0.5-50 ng mL-1 (R2 ≥ 0.996), low limits of detection and quantification (0.42-0.22 ng mL-1) (0.73-1.38 ng mL-1) respectively, good relative recoveries (71.2-104.2%) and reproducibility (RSD 1.8-12.4%, n = 3) for the studied PAHs in water sample. With high enrichment factor (1,000), short extraction time (<30 min), low amounts of adsorbent (100 mg) and low amounts of solvent (0.1 mol) have proven that the microsolid phase extraction method based on calcium alginate-caged multiwalled carbon nanotubes are environmentally friendly and convenient extraction method to use as an alternative adsorbent in the simultaneous preconcentration of PAHs from environmental water samples.
    Matched MeSH terms: Chromatography, Gas/methods*