Affiliations 

  • 1 Health Research Development Unit and Department of Surgery, University Malaya Medical Center, Kuala Lumpur and Sunway Medical Center, Selangor, Malaya
J Urol, 2002 Mar;167(3):1359-62.
PMID: 11832732

Abstract

PURPOSE: We validated the Malay version of the International Prostate Symptom Score in patients with and without urinary symptoms in the Malaysian population.

MATERIALS AND METHODS: Validity and reliability were studied in patients with and without lower urinary tract symptoms. Reliability was evaluated using the test-retest method and internal consistency was assessed by Cronbach's alpha. Sensitivity to change was expressed as the effect size in the pre-intervention versus post-intervention score in additional patients with lower urinary tract symptoms who underwent transurethral prostate resection.

RESULTS: Internal consistency was excellent. A high degree of internal consistency was observed for each of the 7 items and for the total score (Cronbach's alpha 0.53 and greater, and 0.68, respectively). The test-retest correlation coefficients of the 7 items were highly significant. The intraclass correlation coefficient was high at 0.51 and greater. There was a high degree of sensitivity and specificity to the effects of treatment. Significant change from baseline to posttreatment scores was observed in all 8 items in the treated but not in the control group.

CONCLUSIONS: The Malay International Prostate Symptom Score is a suitable, reliable, valid instrument that is sensitive to clinical change in the Malaysian population.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.