Affiliations 

  • 1 Faculty of Allied Health Sciences, Universiti Kebangsaan Malaysia
MyJurnal

Abstract

A study was undertaken to determine the effect of polyethylene and polystyrene used in the manufacture of plastic items on colour perception. Colour vision was assessed using the Ishihara plates, panel 015 test and the Farnsworth Munsell 100-Hue test. Two factories were chosen at random. One factory (referred here as factory A) used virgin resin in pellet form (polyethylene) in the manufacturing of plastic containers to store consumer edible oil. The other factory (referred as factory B) used polystyrene to make plastic bags. A total of 39 healthy employees from factory A (mean age 26.4 :t 8.2 years) and 40 healthy employees from factory B (mean age 26.8 :t 9.6 years) were recruited in this study. A control group of 27 normal healthy subjects (mean age 27.4 :t 4.3 years) who were employees of UKM with no occupational involvement with petroleum derivatives were also recruited in this study and they performed the same colour vision tests. All subjects passed the Ishihara plates test showing that none of the subjects (employees of factory A and B, and control subjects) had a congenital red-green defect. All control subjects passed all of the colour vision tests whilst some employees of factories A and B failed the 015 and FM100 Hue tests. For employees from factory A results from the 015 test showed that 7 (17.9%) had a tritan (blue-yellow) type of defect and 1 (2.6%) had a complex type of defect. The FM 100 Hue results of factory A employees showed that 51.3% (n=20) had a complex type of defect. Total error scores (TES) calculated from the FM 100 Hue test revealed that employees from factory A had a statistically significant higher mean TES of 65.13:!: 48.31 compared to that of control subjects with a mean TES of 31.26:!: 14.93. For employees in factory B, 10 employees (25.0%) had a tritan (blue-yellow) type of defect and 2 (5.0%) had a complex type of defect. Results of the FM 100 Hue test showed that 4 employees (1.0%) had a tritan type of defect whereas 22 (55.0%) had a complex type of defect. Mean total error scores (TES) calculated from the FM 100 Hue test revealed that employees from factory B had a statistically significant higher mean TES of 71.54 :t 54.63 compared with that of control subjects with a mean TES of 31.26 :t. 14.93

The above results show that employees of the plastic factories studies are associated with a higher risk of acquiring colour vision defects as compared to normal subjects who are not engaged in the plastic manufacturing industry. This may have an implication towards the future retinal health of employees in petrod1emical-based industries.