DESIGN: Sarcopenia (age-related muscle loss) causes significant morbidity to the elderly, leading to frequent hospitalizations, disability and death. Few have characterized sarcopenia in the HIV-infected who experience accelerated aging.
METHODS: Sarcopenia was defined as low muscle mass with weak grip strength and/or slow gait speed using lower 20th percentiles of controls. Multivariate logistic and linear regression analyses were used to explore risk factors and health-related outcomes associated with sarcopenia among HIV-infected individuals.
RESULTS: We recruited 315 HIV-infected individuals aged at least 25 years with at least 1-year history of undetectable viral load on treatment (HIV RNA <50 copies/ml). Percentage of sarcopenia in 315 HIV-infected was 8%. Subsequently, 153 of the 315 were paired with age, sex and ethnically matched HIV-uninfected. The percentage of sarcopenia in the HIV-infected (n = 153) compared with uninfected (n = 153) were 10 vs. 6% (P = 0.193) respectively, whereas of those at least 50 years of age among them were 17% vs. 4% (P = 0.049), respectively. Associated risk factors among the HIV-infected include education level, employment status, BMI, baseline CD4 cell count, duration on NRTIs and GGT levels. Identified negative outcomes include mortality risk scores [5.42; 95% CI 1.46-9.37; P = 0.007) and functional disability (3.95; 95% CI 1.57-9.97; P = 0.004).
CONCLUSION: Sarcopenia is more prevalent in HIV-infected at least 50 years old compared with matched controls. Our findings highlight associations between sarcopenia with loss of independence and greater healthcare burden among treated HIV-infected individuals necessitating early recognition and intervention.
METHODS: This was a cross-sectional study on gastric biopsies from 234 consecutive patients (mean age 53.5 [14.8] years) who underwent upper gastrointestinal endoscopy between January 2006 and December 2006.
RESULTS: There were 137 (59%) men and 185 (79%) Malay patients. Among 234 biopsies, CAG was found in 99 and non-atrophic gastritis in 135. Intestinal metaplasia and dysplasia were detected in 8 and 6 atrophic gastritis biopsies, respectively, and in 10 and 3 of non-atrophic gastritis biopsies, respectively. H. pylori were detected in 16 (9 Malays, 7 non- Malays) biopsies (p=0.024); intestinal metaplasia was detected in 4 biopsies (p=0.3) and dysplasia in 5 biopsies (p=0.3). Of the 218 biopsies negative for H. pylori, intestinal metaplasia was found in 14 and dysplasia in 4. The risk of intestinal metaplasia as well as dysplasia was associated with presence of H. pylori infection (p=0.029 and p<0.001 respectively).
CONCLUSION: Even in a setting of low prevalence of H. pylori, intestinal metaplasia and dysplasia were significantly associated with H. pylori infection. The frequency of intestinal metaplasia and dysplasia was similar different between biopsies with atrophic gastritis and non-atrophic gastritis.
METHODS: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs.
RESULTS: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05).
CONCLUSION: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used.