Displaying publications 1 - 20 of 47 in total

Abstract:
Sort:
  1. Abd Rahman NH, Ibrahim AK, Hasikin K, Abd Razak NA
    J Healthc Eng, 2023;2023:3136511.
    PMID: 36860328 DOI: 10.1155/2023/3136511
    Medical device reliability is the ability of medical devices to endure functioning and is indispensable to ensure service delivery to patients. Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) technique was employed in May 2021 to evaluate existing reporting guidelines on medical device reliability. The systematic searching is conducted in eight different databases, including Web of Science, Science Direct, Scopus, IEEE Explorer, Emerald, MEDLINE Complete, Dimensions, and Springer Link, with 36 articles shortlisted from the year 2010 to May 2021. This study aims to epitomize existing literature on medical device reliability, scrutinize existing literature outcomes, investigate parameters affecting medical device reliability, and determine the scientific research gaps. The result of the systematic review listed three main topics on medical device reliability: risk management, performance prediction using Artificial Intelligence or machine learning, and management system. The medical device reliability assessment challenges are inadequate maintenance cost data, determining significant input parameter selection, difficulties accessing healthcare facilities, and limited age in service. Medical device systems are interconnected and interoperating, which increases complexity in assessing their reliability. To the best of our knowledge, although machine learning has become popular in predicting medical device performance, the existing models are only applicable to selected devices such as infant incubators, syringe pumps, and defibrillators. Despite the importance of medical device reliability assessment, there is no explicit protocol and predictive model to anticipate the situation. The problem worsens with the unavailability of a comprehensive assessment strategy for critical medical devices. Therefore, this study reviews the current state of critical device reliability in healthcare facilities. The present knowledge can be improved by adding new scientific data emphasis on critical medical devices used in healthcare services.
  2. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
  3. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
  4. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
  5. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014 Apr 23;13:49.
    PMID: 24755242 DOI: 10.1186/1475-925X-13-49
    BACKGROUND: The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user.

    METHODS: The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements.

    RESULTS: The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45°-55° of rotation or about 14 cm-16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation.

    CONCLUSION: The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics.

  6. Aftab SM, Mohd Rafie AS, Razak NA, Ahmad KA
    PLoS One, 2016;11(4):e0153755.
    PMID: 27104354 DOI: 10.1371/journal.pone.0153755
    One of the major flow phenomena associated with low Reynolds number flow is the formation of separation bubbles on an airfoil's surface. NACA4415 airfoil is commonly used in wind turbines and UAV applications. The stall characteristics are gradual compared to thin airfoils. The primary criterion set for this work is the capture of laminar separation bubble. Flow is simulated for a Reynolds number of 120,000. The numerical analysis carried out shows the advantages and disadvantages of a few turbulence models. The turbulence models tested were: one equation Spallart Allmars (S-A), two equation SST K-ω, three equation Intermittency (γ) SST, k-kl-ω and finally, the four equation transition γ-Reθ SST. However, the variation in flow physics differs between these turbulence models. Procedure to establish the accuracy of the simulation, in accord with previous experimental results, has been discussed in detail.
  7. Ali S, Abu Osman NA, Arifin N, Gholizadeh H, Abd Razak NA, Abas WA
    ScientificWorldJournal, 2014;2014:769810.
    PMID: 25184154 DOI: 10.1155/2014/769810
    This study aimed to compare the effect of satisfaction and perceived problems between Pelite, Dermo with shuttle lock, and Seal-In X5 liners on the transtibial amputees.
  8. Ali S, Abu Osman NA, Eshraghi A, Gholizadeh H, Abd Razak NA, Wan Abas WA
    Clin Biomech (Bristol, Avon), 2013 Nov-Dec;28(9-10):994-9.
    PMID: 24161521 DOI: 10.1016/j.clinbiomech.2013.09.004
    Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems during stair ascent and descent, and to determine their satisfaction effects on users.
  9. Amjad N, Osman HA, Razak NA, Kassian J, Din J, bin Abdullah N
    World J Gastroenterol, 2010 Sep 21;16(35):4443-7.
    PMID: 20845512
    AIM: To study the presence of Helicobacter pylori (H. pylori) virulence factors and clinical outcome in H. pylori infected patients.

    METHODS: A prospective analysis of ninety nine H. pylori-positive patients who underwent endoscopy in our Endoscopy suite were included in this study. DNA was isolated from antral biopsy samples and the presence of cagA, iceA, and iceA2 genotypes were determined by polymerase chain reaction and a reverse hybridization technique. Screening for H. pylori infection was performed in all patients using the rapid urease test (CLO-Test).

    RESULTS: From a total of 326 patients who underwent endoscopy for upper gastrointestinal symptoms, 99 patients were determined to be H. pylori-positive. Peptic ulceration was seen in 33 patients (33%). The main virulence strain observed in this cohort was the cagA gene isolated in 43 patients. cagA was associated with peptic ulcer pathology in 39.5% (17/43) and in 28% (16/56) of non-ulcer patients. IceA1 was present in 29 patients (29%) and iceA2 in 15 patients (15%). Ulcer pathology was seen in 39% (11/29) of patients with iceA1, while 31% (22/70) had normal findings. The corresponding values for iceA2 were 33% (5/15) and 33% (28/84), respectively.

    CONCLUSION: Virulence factors were not common in our cohort. The incidence of factors cagA, iceA1 and iceA2 were very low although variations were noted in different ethnic groups.

  10. Chemmalar S, Intan-Shameha AR, Abdullah CAC, Ab Razak NA, Yusof LM, Ajat M, et al.
    Nanomaterials (Basel), 2021 Aug 02;11(8).
    PMID: 34443820 DOI: 10.3390/nano11081988
    Calcium carbonate has slowly paved its way into the field of nanomaterial research due to its inherent properties: biocompatibility, pH-sensitivity, and slow biodegradability. In our efforts to synthesize calcium carbonate nanoparticles (CSCaCO3NP) from blood cockle shells (Anadara granosa), we developed a simple method to synthesize CSCaCO3NP, and loaded them with gefitinib (GEF) and paclitaxel (PTXL) to produce mono drug-loaded GEF-CSCaCO3NP, PTXL-CSCaCO3NP, and dual drug-loaded GEF-PTXL-CSCaCO3NP without usage of toxic chemicals. Fourier-transform infrared spectroscopy (FTIR) results reveal that the drugs are bound to CSCaCO3NP. Scanning electron microscopy studies reveal that the CSCaCO3NP, GEF-CSCaCO3NP, PTXL-CSCaCO3NP, and GEF-PTXL-CSCaCO3NP are almost spherical nanoparticles, with a diameter of 63.9 ± 22.3, 83.9 ± 28.2, 78.2 ± 26.4, and 87.2 ± 26.7 (nm), respectively. Dynamic light scattering (DLS) and N2 adsorption-desorption experiments revealed that the synthesized nanoparticles are negatively charged and mesoporous, with surface areas ranging from ~8 to 10 (m2/g). Powder X-ray diffraction (PXRD) confirms that the synthesized nanoparticles are aragonite. The CSCaCO3NP show excellent alkalinization property in plasma simulating conditions and greater solubility in a moderately acidic pH medium. The release of drugs from the nanoparticles showed zero order kinetics with a slow and sustained release. Therefore, the physico-chemical characteristics and in vitro findings suggest that the drug loaded CSCaCO3NP represent a promising drug delivery system to deliver GEF and PTXL against breast cancer.
  11. Ghazali MF, Abd Razak NA, Abu Osman NA, Gholizadeh H
    Turk J Phys Med Rehabil, 2018 Sep;64(3):268-276.
    PMID: 31453521 DOI: 10.5606/tftrd.2018.1668
    Objectives: This study aims to assess the level of awareness of transtibial amputee patients on stump contractures and their compliance with efforts implemented to prevent the condition.

    Patients and methods: This study included 50 unilateral transtibial amputees (26 males, 24 females; mean age 55.4±14.7 years; range, 18 to 78 years) who met the respondent criteria of the study. The respondents were randomly selected and were issued with a questionnaire.

    Results: The majority of the transtibial amputees were aware of stump contracture complications. It was found that they also preferred methods of prevention which required less effort, was cost-effective, and were also practical.

    Conclusion: More focus should be placed on contracture prevention methods which were most complied with by the patients. This is because the effectiveness of a prevention method is highly influenced by patients' compliance with the method. Patients with a higher risk of developing stump contractures should be also given more attention in post-amputation care.

  12. Gholizadeh H, Osman NA, Eshraghi A, Abd Razak NA
    Biomed Eng Online, 2014;13:89.
    PMID: 24981801 DOI: 10.1186/1475-925X-13-89
    Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock).
  13. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA
    Clin Biomech (Bristol, Avon), 2014 Jan;29(1):87-97.
    PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013
    Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
  14. Hamdan PNF, Hamzaid NA, Abd Razak NA, Hasnan N
    J Sport Health Sci, 2022 Nov;11(6):671-680.
    PMID: 33068748 DOI: 10.1016/j.jshs.2020.10.002
    BACKGROUND: Due to its clinically proven safety and health benefits, functional electrical stimulation (FES) cycling has become a popular exercise modality for individuals with spinal cord injury (SCI). Since its inception in 2013, the Cybathlon championship has been a platform for publicizing the potential of FES cycling in rehabilitation and exercise for individuals with SCI. This study aimed to evaluate the contribution of the Cybathlon championship to the literature on FES cycling for individuals with SCI 3 years pre and post the staging of the Cybathlon championship in 2016.

    METHODS: Web of Science, Scopus, ScienceDirect, IEEE Xplore, and Google Scholar databases were searched for relevant studies published between January 2013 and July 2019. The quality of the included studies was objectively evaluated using the Downs and Black checklist.

    RESULTS: A total of 129 articles on FES cycling were retained for analysis. A total of 51 articles related to Cybathlon were reviewed, and 14 articles were ultimately evaluated for the quality. In 2017, the year following the Cybathlon championship, Web of Science cited 23 published studies on the championship, which was almost 5-fold more than that in 2016 (n = 5). Training was most often reported as a topic of interest in these studies, which mostly (76.7%) highlighted the training parameters of interest to participating teams in their effort to maximize their FES cycling performance during the Cybathlon championship.

    CONCLUSION: The present study indicates that the Cybathlon championship in 2016 contributed to the number of literature published in 2017 on FES cycling for individuals with SCI. This finding may contribute to the lessons that can be learned from participation in the Cybathlon and potentially provide additional insights into research in the field of race-based FES cycling.

  15. Hamdan PNF, Hamzaid NA, Hasnan N, Abd Razak NA, Razman R, Usman J
    Sci Rep, 2024 Mar 18;14(1):6451.
    PMID: 38499594 DOI: 10.1038/s41598-024-56955-w
    Literature has shown that simulated power production during conventional functional electrical stimulation (FES) cycling was improved by 14% by releasing the ankle joint from a fixed ankle setup and with the stimulation of the tibialis anterior and triceps surae. This study aims to investigate the effect of releasing the ankle joint on the pedal power production during FES cycling in persons with spinal cord injury (SCI). Seven persons with motor complete SCI participated in this study. All participants performed 1 min of fixed-ankle and 1 min of free-ankle FES cycling with two stimulation modes. In mode 1 participants performed FES-evoked cycling with the stimulation of quadriceps and hamstring muscles only (QH stimulation), while Mode 2 had stimulation of quadriceps, hamstring, tibialis anterior, and triceps surae muscles (QHT stimulation). The order of each trial was randomized in each participant. Free-ankle FES cycling offered greater ankle plantar- and dorsiflexion movement at specific slices of 20° crank angle intervals compared to fixed-ankle. There were significant differences in the mean and peak normalized pedal power outputs (POs) [F(1,500) = 14.03, p 
  16. Hashim NA, Abd Razak NA, Gholizadeh H, Abu Osman NA
    JMIR Serious Games, 2021 Feb 04;9(1):e17017.
    PMID: 33538698 DOI: 10.2196/17017
    BACKGROUND: Brain plasticity is an important factor in prosthesis usage. This plasticity helps with brain adaptation to learn new movement and coordination patterns needed to control a prosthetic hand. It can be achieved through repetitive muscle training that is usually very exhausting and often results in considerable reduction in patient motivation. Previous studies have shown that a playful concept in rehabilitation can increase patient engagement and perseverance.

    OBJECTIVE: This study investigated whether the inclusion of video games in the upper limb amputee rehabilitation protocol could have a beneficial impact for muscle preparation, coordination, and patient motivation among individuals who have undergone transradial upper limb amputation.

    METHODS: Ten participants, including five amputee participants and five able-bodied participants, were enrolled in 10 1-hour sessions within a 4-week rehabilitation program. In order to investigate the effects of the rehabilitation protocol used in this study, virtual reality box and block tests and electromyography (EMG) assessments were performed. Maximum voluntary contraction was measured before, immediately after, and 2 days after interacting with four different EMG-controlled video games. Participant motivation was assessed with the Intrinsic Motivation Inventory (IMI) questionnaire and user evaluation survey.

    RESULTS: Survey analysis showed that muscle strength and coordination increased at the end of training for all the participants. The results of Pearson correlation analysis indicated that there was a significant positive association between the training period and the box and block test score (r8=0.95, P

  17. Hashim NA, Abd Razak NA, Abu Osman NA, Gholizadeh H
    Proc Inst Mech Eng H, 2018 Jan;232(1):3-11.
    PMID: 29199518 DOI: 10.1177/0954411917744585
    Body-powered prostheses are known for their advantages of cost, reliability, training period, maintenance, and proprioceptive feedback. This study primarily aims to analyze the work related to the improvement of upper limb body-powered prostheses prior to 2016. A systematic review conducted via the search of the Web of Science electronic database, Google Scholar, and Google Patents identified 155 papers from 1921 to 2016. Sackett's initial rules of evidence were used to determine the levels of evidence, and only papers categorized in the design and development category and patents were analyzed. A total of 40 papers in the sixth level of "Design and Development" of an upper limb body-powered prosthesis were found. Approximately 81% were categorized under mechanical alteration. Most papers were patent-type documents (48%), with the Journal of Rehabilitation Research and Development publishing most of the articles related to the design and development of body-powered prostheses. Papers in the scope of the study were published once every 3 years in almost a century, proving that only a few studies were conducted to improve body-powered arms compared with myoelectric technology. Further research should be carried out mainly in areas that have received less attention.
  18. Hashim NA, Abd Razak NA, Shanmuganathan T, Jaladin RA, Gholizadeh H, Abu Osman NA
    Eur J Phys Rehabil Med, 2022 Aug;58(4):612-620.
    PMID: 35044131 DOI: 10.23736/S1973-9087.22.06794-6
    INTRODUCTION: Virtual reality has recently become a popular application for rehabilitation and motor control research. This technology has emerged as a valid addition to conventional therapy and promises a successful rehabilitation. This study describes recent research related to the use of virtual reality applications in the rehabilitation of individuals with upper limb loss and to see whether this technology has enough proof of its applicability.

    EVIDENCE ACQUISITION: Searches were conducted with the Web of Science, Google Scholar, IEEE Xplore, and PubMed databases from inception up to September 2020. Articles that employed virtual reality in the rehabilitation of individual with upper limb loss were included in the research if it is written in English, the keyword exists in the title and abstract; it uses visual feedback in nonimmersive, semi-immersive, or fully immersive virtual environments. Data extraction was carried out by two independent researchers. The study was drafted using the Preferred Reporting Items for Systematic Reviews and Meta-analysis Protocols (PRISMA).

    EVIDENCE SYNTHESIS: A total of 38 articles met the inclusion criteria. Most studies were published between 2010 and 2020. Thirty-nine percent of the studies (N.=15), originates from North America; 55% of the studies (N.=21), were publicly funded; 61% of the studies (N.=24), was without disclosure of conflict of interest; 82% of the studies (N.=31), were cited in other studies. All the studies were published in journals and conference proceedings. Sixty-six percent of the studies (N.=25) has come out with positive outcome. The design studies were mostly case reports, case series, and poorly designed cohort studies that made up 55% (N.=21) of all the studies cited here.

    CONCLUSIONS: The research conducted on the use of virtual reality in individual with upper limb loss rehabilitation is of very low quality. The improvements to the research protocol are much needed. It is not necessary to develop new devices, but rather to assess existing devices with well-conducted randomized controlled trials.