Displaying publications 1 - 20 of 26 in total

Abstract:
Sort:
  1. Moosavi Tayebi R, Wirza R, Sulaiman PS, Dimon MZ, Khalid F, Al-Surmi A, et al.
    J Cardiothorac Surg, 2015;10:58.
    PMID: 25896185 DOI: 10.1186/s13019-015-0249-2
    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography.
    Matched MeSH terms: Coronary Angiography/methods*
  2. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, et al.
    Am Heart J, 2006 Jun;151(6):1323.e1-6.
    PMID: 16781246
    The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
    Matched MeSH terms: Coronary Angiography/methods*
  3. Xie CB, Chan MY, Teo SG, Low AF, Tan HC, Lee CH
    Singapore Med J, 2011 Nov;52(11):835-9.
    PMID: 22173254
    There is a paucity of data on acute myocardial infarction (AMI) in young Asian women and of comparative data among various ethnic groups with respect to risk factor profile and clinical outcomes. We present a comprehensive overview of the clinical characteristics of young Asian women with AMI and a comparative analysis among Chinese, Malay and Indian women in a multi-ethnic Asian country.
    Matched MeSH terms: Coronary Angiography/methods
  4. Salah H, Tamam N, Rabbaa M, Abuljoud M, Zailae A, Alkhorayef, et al.
    Appl Radiat Isot, 2023 Feb;192:110548.
    PMID: 36527854 DOI: 10.1016/j.apradiso.2022.110548
    Computed tomography coronary angiography (CTCA) has generated tremendous interest over the past 20 years by using multidetector computed tomography (MDCT) because of its high diagnostic accuracy and efficacy in assessing patients with coronary artery disease. This technique is related to high radiation doses, which has raised serious concerns in the literature. Effective dose (E, mSv) may be a single parameter meant to reflect the relative risk from radiation exposure. Therefore, it is necessary to calculate this quantity to point to relative radiation risk. The objectives of this study are to evaluate patients' exposure during diagnostic CCTA procedures and to estimate the risks. Seven hundred ninety patients were estimated during three successive years. The patient's exposure was estimated based on a CT device's delivered radiation dose (Siemens Somatom Sensation 64 (64-MDCT)). The participating physicians obtained the parameters relevant to the radiation dose from the scan protocol generated by the CT system after each CCTA study. The parameters included the volume CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy × cm). The mean and range of CTDIvol (mGy) and DLP (mGy × cm) for three respective year was (2018):10.8 (1.14-77.7) and 2369.8 ± 1231.4 (290.4-6188.9), (2019): 13.82 (1.13-348.5), and 2180.5 (501.8-9534.5) and (2020) 10.9 (0.7-52.9) and 1877.3 (149.4-5011.1), respectively. Patients' effective doses were higher compared to previous studies. Therefore, the CT acquisition parameter optimization is vital to reduce the dose to its minimal value.
    Matched MeSH terms: Coronary Angiography/methods
  5. Cainzos-Achirica M, Rampal S, Chang Y, Ryu S, Zhang Y, Zhao D, et al.
    Atherosclerosis, 2015 Aug;241(2):350-6.
    PMID: 26071657 DOI: 10.1016/j.atherosclerosis.2015.05.031
    OBJECTIVE: To evaluate the association between brachial-ankle pulse wave velocity (baPWV), a convenient, non-radiating, readily available measurement of arterial stiffness, and coronary artery calcium (CAC), a reliable marker of coronary atherosclerosis, in a large sample of young and middle-aged asymptomatic adults; and to assess the incremental value of baPWV for detecting prevalent CAC beyond traditional risk factors.
    METHODS: Cross-sectional study of 15,185 asymptomatic Korean adults who voluntarily underwent a comprehensive health screening program including measurement of baPWV and CAC. BaPWV was measured using an oscillometric method with cuffs placed on both arms and ankles. CAC burden was assessed using a multi-detector CT scan and scored following Agatston's method.
    RESULTS: The prevalence of CAC > 0 and CAC > 100 increased across baPWV quintiles. The multivariable-adjusted odds ratios (95% CI) for CAC > 0 comparing baPWV quintiles 2-5 versus quintile 1 were 1.06 (0.87-1.30), 1.24 (1.02-1.50), 1.39 (1.15-1.69) and 1.60 (1.31-1.96), respectively (P trend < 0.001). Similarly, the relative prevalence ratios for CAC > 100 were 1.30 (0.74-2.26), 1.59 (0.93-2.71), 1.74 (1.03-2.94) and 2.59 (1.54-4.36), respectively (P trend < 0.001). For CAC > 100, the area under the ROC curve for baPWV alone was 0.71 (0.68-0.74), and the addition of baPWV to traditional risk factors significantly improved the discrimination and calibration of models for detecting prevalent CAC > 0 and CAC > 100.
    CONCLUSIONS: BaPWV was independently associated with the presence and severity of CAC in a large sample of young and middle-aged asymptomatic adults. BaPWV may be a valuable tool for identifying apparently low-risk individuals with increased burden of coronary atherosclerosis.
    KEYWORDS: Arterial stiffness; Atherosclerosis; Coronary artery calcium; Pulse wave velocity; Subclinical disease
    Matched MeSH terms: Coronary Angiography/methods
  6. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Coronary Angiography/methods
  7. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Coronary Angiography/methods
  8. Yun KE, Chang Y, Rampal S, Zhang Y, Cho J, Jung HS, et al.
    J Clin Gastroenterol, 2018 07;52(6):508-514.
    PMID: 28471937 DOI: 10.1097/MCG.0000000000000824
    GOALS: Because of shared risk factors between clinically manifest cardiovascular disease and colorectal cancer, we hypothesized the coexistence of subclinical atherosclerosis measured by coronary artery calcium (CAC) and colorectal adenoma (CRA) and that these 2 processes would also share common risk factors.

    BACKGROUND: No study has directly compared the risk factors associated with subclinical coronary atherosclerosis and CRA.

    STUDY: This was a cross-sectional study using multinomial logistic regression analysis of 4859 adults who participated in a health screening examination (2010 to 2011; analysis 2014 to 2015). CAC scores were categorized as 0, 1 to 100, or >100. Colonoscopy results were categorized as absent, low-risk, or high-risk CRA.

    RESULTS: The prevalence of CAC>0, CAC 1 to 100 and >100 was 13.0%, 11.0%, and 2.0%, respectively. The prevalence of any CRA, low-risk CRA, and high-risk CRA was 15.1%, 13.0%, and 2.1%, respectively. The adjusted odds ratios (95% confidence interval) for CAC>0 comparing participants with low-risk and high-risk CRA with those without any CRA were 1.35 (1.06-1.71) and 2.09 (1.29-3.39), respectively. Similarly, the adjusted odds ratios (95% confidence interval) for any CRA comparing participants with CAC 1 to 100 and CAC>100 with those with no CAC were 1.26 (1.00-1.6) and 2.07 (1.31-3.26), respectively. Age, smoking, diabetes, and family history of CRC were significantly associated with both conditions.

    CONCLUSIONS: We observed a graded association between CAC and CRA in apparently healthy individuals. The coexistence of both conditions further emphasizes the need for more evidence of comprehensive approaches to screening and the need to consider the impact of the high risk of coexisting disease in individuals with CAC or CRA, instead of piecemeal approaches restricted to the detection of each disease independently.

    Matched MeSH terms: Coronary Angiography/methods
  9. Sim KH, Ong TK, Chin SP, Wong M
    Indian Heart J, 2007 Mar-Apr;59(2 Suppl B):B25-32.
    PMID: 19153433
    Matched MeSH terms: Coronary Angiography/methods*
  10. Sabarudin A, Sun Z, Yusof AK
    Int J Cardiol, 2013 Sep 30;168(2):746-53.
    PMID: 23098849 DOI: 10.1016/j.ijcard.2012.09.217
    This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT).
    Matched MeSH terms: Coronary Angiography/methods
  11. Vu H, Khanh Tuong TT, Hoang Lan N, Quoc Thang T, Bilgin K, Hoa T, et al.
    Clin Ter, 2022 11 15;173(6):565-571.
    PMID: 36373456 DOI: 10.7417/CT.2022.2483
    Background: Various non-invasive methods have been studied for assessing the severity of fatty liver disease and coronary atherosclero-sis. However, the correlation between hepatic steatosis and coronary atherosclerosis has not been fully studied, either globally or specifically in Vietnam. This study investigated the association between nonalcoholic fatty liver disease (NAFLD) and coronary atherosclerosis using coronary computed tomography angiography (CCTA).

    Methods: An analytical cross-sectional study was performed, including 223 patients treated by the Cardiology Department, the Emergency Interventional Cardiology Departments, and the Internal Cardiology Clinic of Thong Nhat Hospital.

    Results: In our cohort of 223 patients, the NAFLD was detected in 66% of the population, the mean coronary artery stenosis (CAS) was 44.54% ± 20.23%, and the mean coronary artery calcium score (CACS) was 3569.05 ± 425.99, as assessed using the Agatston method. The proportion of patients with significant atherosclerotic plaque (CAS 50%) >was 32%, whereas the remaining 68% had insignificant stenosis. Among our study population, 16% had no coronary artery calcification, 38% had mild calcification, and 46% had moderate to severe calcification. In the group of NAFLD patients, 33.3% had significant atherosclerotic plaque, which was not significantly different from the rate in individuals without NAFLD (p = 0.51). Mild coronary artery calcification was detected in 37.4% of NAFLD patients, and moderate to severe calcification was detected in 48.3% (p = 0.45).

    Conclusions: NAFLD was not found to be strongly associated with coronary atherosclerosis in this study. More studies with larger sample sizes remain necessary to verify whether any correlation exists.

    Matched MeSH terms: Coronary Angiography/methods
  12. Rosenberg M, Waliszewski M, Krackhardt F, Chin K, Wan Ahmad WA, Caramanno G, et al.
    J Interv Cardiol, 2019;2019:6548696.
    PMID: 31772539 DOI: 10.1155/2019/6548696
    Objectives: We analyzed the efficacy of drug coated balloons (DCB) as a stand-alone-therapy in de novo lesions of large coronary arteries. DCBs seem to be an attractive alternative for the stent-free interventional treatment of de novo coronary artery disease (CAD). However, data regarding a DCB-only approach in de novo CAD are currently limited to vessels of small caliber.

    Methods: By means of propensity score (PS) matching 234 individuals with de novo CAD were identified with similar demographic characteristics. This patient population was stratified in a 1:1 fashion according to a reference vessel diameter cut-off of 2.75 mm in small and large vessel disease. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 9 months.

    Results: Patients with small vessel disease had an average reference diameter of 2.45 ± 0.23 mm, while the large vessel group averaged 3.16 ± 0.27 mm. Regarding 9-month major adverse cardiac event (MACE), 5.7% of the patients with small and 6.1% of the patients with large vessels had MACE (p=0.903). Analysis of the individual MACE components revealed a TLR rate of 3.8% in small and 1.0% in large vessels (p=0.200). Of note, no thrombotic events in the DCB treated coronary segments occurred in either group during the 9-month follow-up.

    Conclusions: Our data demonstrate for the first time that DCB-only PCI of de novo lesions in large coronary arteries (>2.75 mm) is safe and as effective. Interventional treatment for CAD without permanent or temporary scaffolding, demonstrated a similar efficacy for large and small vessels.

    Matched MeSH terms: Coronary Angiography/methods
  13. Sabarudin A, Md Yusof AK, Tay MF, Ng KH, Sun Z
    Radiat Prot Dosimetry, 2013;153(4):441-7.
    PMID: 22807493 DOI: 10.1093/rpd/ncs127
    This study was conducted to investigate the effectiveness of dose-saving protocols in dual-source computed tomography (CT) coronary angiography compared with invasive coronary angiography (ICA). On 50 patients who underwent coronary CT angiography was performed dual-source CT (DSCT) and compared with ICA procedures. Entrance skin dose (ESD), which was measured at the thyroid gland, and effective dose (E) were assessed for both imaging modalities. The mean ESD measured at the thyroid gland was the highest at 120 kVp, followed by the 100 kVp DSCT and the ICA protocols with 4.0±1.8, 2.7±1.0 and 1.1±1.2 mGy, respectively. The mean E was estimated to be 10.3±2.1, 6.2±2.3 and 5.3±3.4 mSv corresponding to the 120-kVp, 100-kVp DSCT and ICA protocols, respectively. The application of 100 kVp in DSCT coronary angiography is feasible only in patients with a low body mass index of <25 kg m(-2), which leads to a significant dose reduction with the radiation dose being equivalent to that of ICA.
    Matched MeSH terms: Coronary Angiography/methods*
  14. Choi Y, Chang Y, Lee JE, Chun S, Cho J, Sung E, et al.
    Atherosclerosis, 2015 Aug;241(2):305-12.
    PMID: 26062990 DOI: 10.1016/j.atherosclerosis.2015.05.036
    OBJECTIVE:
    The association of egg consumption with subclinical coronary atherosclerosis remains unknown. Our aim was to examine the association between egg consumption and prevalence of coronary artery calcium (CAC).
    METHODS:
    Cross-sectional study of 23,417 asymptomatic adult men and women without a history of cardiovascular disease (CVD) or hypercholesterolemia, who underwent a health screening examination including cardiac computed tomography for CAC scoring and completed a validated food frequency questionnaire at the Kangbuk Samsung Hospital Total Healthcare Centers, South Korea (March 2011-April 2013).
    RESULTS:
    The prevalence of detectable CAC (CAC score > 0) was 11.2%. In multivariable-adjusted models, CAC score ratio (95% confidence interval [CI]) comparing participants eating ≥ 7 eggs/wk to those eating < 1 egg/wk was 1.80 (1.14-2.83; P for trend = 0.003). The multivariable CAC score ratio (95% CI) associated with an increase in consumption of 1 egg/day was 1.54 (1.11-2.14). The positive association seemed to be more pronounced among participants with low vegetable intake (P for interaction = 0.02) and those with high BMI (P for interaction = 0.05). The association was attenuated and no longer significant after further adjustment for dietary cholesterol.
    CONCLUSION:
    Egg consumption was associated with an increased prevalence of subclinical coronary atherosclerosis and with a greater degree of coronary calcification in asymptomatic Korean adults, which may be mediated by dietary cholesterol. The association was particularly pronounced among individuals with low vegetable intake and those with high BMI.
    KEYWORDS:
    Coronary artery calcium score; Coronary artery disease; Egg consumption
    Matched MeSH terms: Coronary Angiography/methods
  15. Sridharan R, Low SF, Mohd MR, Kew TY
    Singapore Med J, 2014 Oct;55(10):e165-8.
    PMID: 25631906
    Epistaxis is commonly encountered in otorhinolaryngologic practice. However, severe and recurrent epistaxis is rarely seen, especially that originating from a pseudoaneurysm of the intracavernous internal carotid artery (ICA). We herein present the case of a 32-year-old man who was involved in a motor vehicle accident and subsequently developed recurrent episodes of profuse epistaxis for the next three months, which required blood transfusion and nasal packing to control the bleeding. Computed tomography angiography revealed a large intracavernous ICA pseudoaneurysm measuring 1.7 cm × 1.2 cm × 1.0 cm. The patient underwent emergent four-vessel angiography and coil embolisation and was discharged one week later without any episode of bleeding. He remained asymptomatic after three-month and one‑year intervals. This case report highlights a large intracavernous ICA pseudoaneurysm as a rare cause of epistaxis, which requires a high index of suspicion in the right clinical setting and emergent endovascular treatment to prevent mortality.
    Matched MeSH terms: Coronary Angiography/methods
  16. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Coronary Angiography/methods
  17. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

    Matched MeSH terms: Coronary Angiography/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links