Displaying publications 1 - 20 of 58 in total

Abstract:
Sort:
  1. Ab Hamid S, Joshi S
    Oxf Med Case Reports, 2019 Apr;2019(4):omy137.
    PMID: 31049209 DOI: 10.1093/omcr/omy137
    Giant coronary artery aneurysms are rare, with reported incidence of 0.02-0.2% (Morita H, Ozawa H, Yamazaki S, Yamauchi Y, Tsuji M, Katsumata T, et al. A case of giant coronary artery aneurysm with fistulous connection to the pulmonary artery: a case report and review of the literature. Intern Med. 2012; 51:1361-6.). Multiple giant aneurysms involving all three coronary arteries are even rarer. We report a rare case of multiple giant aneurysms involving the right coronary, left anterior descending and left circumflex arteries, supplemented with excellent multimodality imaging representations, i.e. plain radiograph, echocardiography, magnetic resonance imaging and computed tomography coronary angiogram.
    Matched MeSH terms: Coronary Vessels
  2. Ahamad NA, Kamangar S, Badruddin IA
    Biomed Mater Eng, 2018;29(3):319-332.
    PMID: 29578467 DOI: 10.3233/BME-181734
    The current study investigates the curvature effect due to various angles of curvature on the blood flow in human artery. The stenosis is considered to have three sizes 70%, 80% and 90% blockage before the curve section of artery. Numerical study of four different angle of curvature was considered to understand the flow behavior of artery having various curvatures, on the hemodynamics factors that includes drop in arterial pressure, flow velocity as well as wall shear stress. It was found that, the augmentation of the flow resistance due to the curvature increases in presence of stenosis. It was also noted that the wall shear is higher at the outer wall as compared to the inside wall in four models considered. Results showed that both the curvature of artery and size of the stenosis have significant impact. These two factors should be considered by cardiologist to assess the complexity of stenosis.
    Matched MeSH terms: Coronary Vessels/pathology; Coronary Vessels/physiopathology*
  3. Al-Surmi A, Wirza R, Mahmod R, Khalid F, Dimon MZ
    J Cardiothorac Surg, 2014;9:161.
    PMID: 25274253 DOI: 10.1186/s13019-014-0161-1
    The identification and segmentation of inhomogeneous image regions is one of the most challenging issues nowadays. The surface vessels of the human heart are important for the surgeons to locate the region where to perform the surgery and to avoid surgical injuries. In addition, such identification, segmentation, and visualisation helps novice surgeons in the training phase of cardiac surgery.
    Matched MeSH terms: Coronary Vessels/radiography*
  4. Alghrairi M, Sulaiman N, Mutashar S
    Sensors (Basel), 2020 Aug 01;20(15).
    PMID: 32752231 DOI: 10.3390/s20154303
    In-stent restenosis concerning the coronary artery refers to the blood clotting-caused re-narrowing of the blocked section of the artery, which is opened using a stent. The failure rate for stents is in the range of 10% to 15%, where they do not remain open, thereby leading to about 40% of the patients with stent implantations requiring repeat procedure within one year, despite increased risk factors and the administration of expensive medicines. Hence, today stent restenosis is a significant cause of deaths globally. Monitoring and treatment matter a lot when it comes to early diagnosis and treatment. A review of the present stent monitoring technology as well as the practical treatment for addressing stent restenosis was conducted. The problems and challenges associated with current stent monitoring technology were illustrated, along with its typical applications. Brief suggestions were given and the progress of stent implants was discussed. It was revealed that prime requisites are needed to achieve good quality implanted stent devices in terms of their size, reliability, etc. This review would positively prompt researchers to augment their efforts towards the expansion of healthcare systems. Lastly, the challenges and concerns associated with nurturing a healthcare system were deliberated with meaningful evaluations.
    Matched MeSH terms: Coronary Vessels
  5. Anwar A, Chan KMJ, Awang Y, Ping DC
    Med J Malaysia, 2019 Oct;74(5):436-438.
    PMID: 31649223
    Anomalous Aortic Origin of a Coronary Artery (AAOCA) is a rare anomaly of the coronary artery with a considerable risk of sudden cardiac death due to ischaemia of the heart. Symptoms may include chest pain on exertion, breathlessness or dizziness. We encountered a case of a 46- year-old female who complained of exertional chest pain with a positive-stress test and subsequently diagnosed with AAOCA through CT angiography (CTA). She successfully underwent a coronary artery bypass graft (CABG) surgery using a saphenous vein graft with uneventful recovery. Right internal mammary artery (RIMA) was not used as it was flimsy and the flow was very poor.
    Matched MeSH terms: Coronary Vessels
  6. Atif Abbas S, Sharma JN, Pauzi A, Yusof M
    Gen. Pharmacol., 1999 Sep;33(3):243-7.
    PMID: 10480657
    The present study was conducted to examine the effect of bradykinin and bradykinin 2 receptor antagonist on survival time in rats with coronary artery ligation for 15 min and continuously. We also evaluated the heart rate and blood pressure responses in the presence and absence of bradykinin and its antagonist. Bradykinin treatment (4 microg and 8 microg/kg IV) significantly (p < 0.05) increased the survival time of rats compared with saline-treated rats with coronary artery ligation for 15 min and continuously. The heart rate and blood pressure responses were significantly (p < 0.001) altered in the presence of coronary artery ligation. Bradykinin antagonist treatment (4 microg/kg IV) abolished the effect of bradykinin and thus reduced the survival time of rats with coronary artery ligation. The mean value of survival time between saline-treated and bradykinin antagonist- plus bradykinin-treated rats did not differ significantly (p > 0.05).
    Matched MeSH terms: Coronary Vessels/physiopathology*; Coronary Vessels/surgery
  7. Azarisma, S.M.S., Rosli, M.A.B.
    MyJurnal
    We report a-56-year old army pensioner who presented initially to a peripheral hospital with acute ST-elevation inferior myocardial infarction thrombolysed with streptokinase. He was subsequently referred to the National Heart Institute (Institut Jantung Negara, Malaysia) for coronary revascularization. Coronary angiogram revealed an ectatic right coronary artery with discrete lesions at the proximal and distal segments stented with bare metal stents (BMS). Post dilatation shots revealed a wire-induced, distal dissection at the posterior left ventricular artery remedied by balloon angioplasty but resulting in balloon-induced crumpling of the distal BMS. We discuss the importance of sequential, distal-to-proximal coronary intervention, stent crumpling and remedial strategies.
    Matched MeSH terms: Coronary Vessels
  8. Azmi MI, Nair AK, Hashim SA
    Innovations (Phila), 2024;19(2):175-183.
    PMID: 38577864 DOI: 10.1177/15569845241238999
    OBJECTIVE: We evaluated the effectiveness of a consistent and structured self-practice coronary anastomosis program using a homemade low-fidelity beating-heart simulator.

    METHODS: An intermediary trainee was subjected to an 8-week structured self-practice program. The program was divided into 2 parts of nonbeating and beating practices with a minimum number of timed anastomoses. Each part was followed by an assessment using an objective skills assessment tool score. The beating-heart simulator was built using motorized toy blocks connected wirelessly to a smartphone application. This was coded to enable rate selection. A junior consultant was compared to the subject at the end of the program. Both were tasked to perform 1 coronary anastomosis for both off-pump coronary artery bypass (OPCAB) and minimally invasive CAB (MICS) setup. The primary outcomes were anastomotic time and score compared with the junior consultant. Secondary outcomes were progression of anastomotic time and score throughout the program.

    RESULTS: Overall performance of the studied subject approached the performance of the junior consultant in terms of time (OPCAB, 489 vs 605 s; MICS, 712 vs 652 s) and scores (OPCAB, 21 vs 20.7; MICS, 19 vs 20.6). There were inverse correlations between anastomosis time and number of practices for both nonbeating and beating anastomoses. Overall improvement was observed in terms of assessment scoring by 26.6%.

    CONCLUSIONS: A structured self-practice program using an affordable and accessible simulator was able to help trainees overcome the MICS anastomosis learning curve quicker when introduced earlier. This may encourage earlier adoption of MICS among surgeons.

    Matched MeSH terms: Coronary Vessels/surgery
  9. Blin J, Ahmad Z, Rampal LR, Mohtarrudin N, Tajudin AK, Adnan RS
    Genes Genet Syst, 2013;88(3):199-209.
    PMID: 24025248
    Identifying susceptible genes associated with the pathogenesis of atherosclerosis (ATH) may contribute toward better management of this condition. This preliminary study was aimed at assessing the expression levels of 11 candidate genes, namely tumor protein (TP53), transforming growth factor, beta receptor II (TGFBR2), cysthathionenine-beta-synthase (CBS), insulin receptor substrate 1 (IRS1), lipoprotein lipase (LPL), methylenetetrahydrofolate reductase (MTHFR), thrombomodulin (THBD), lecithin-cholesterol acyltransferase (LCAT), matrix metallopeptidase 9 (MMP9), low density lipoprotein receptor (LDLR), and arachidonate 5-lipoxygenase-activating protein (ALOX5AP) genes associated with ATH. Twelve human coronary artery tissues (HCATs) were obtained from deceased subjects who underwent post-mortem procedures. Six atherosclerotic coronary artery tissue (ACAT) samples representing the cases and non-atherosclerotic coronary artery tissue (NCAT) samples as controls were gathered based on predetermined inclusion and exclusion criteria. Gene expression levels were assessed using the GenomeLab Genetic Analysis System (GeXP). The results showed that LDLR, TP53, and MMP9 expression levels were significantly increased in ACAT compared to NCAT samples (p < 0.05). Thus, LDLR, TP53, and MMP9 genes may play important roles in the development of ATH in a Malaysian study population.
    Matched MeSH terms: Coronary Vessels/metabolism*
  10. Bond MG, Bullock BC, Bellinger DA, Hamm TE
    Am J Pathol, 1980 Dec;101(3):675-92.
    PMID: 7446712
    Relatively few cases of myocardial infarction associated with coronary artery atherosclerosis have been described previously in macaques. In this study the authors report the prevalence and characteristics of coronary artery atherosclerosis and myocardial infarction in 10 rhesus (Macaca mulatta) and two cynomolgus (Macaca fascicularis) macaques that were fed atherogenic diets for 16 months or longer. Our findings show clearly that myocardial infarction occurs in macaques with diet-induced atherosclerosis. The frequency seems to be related to the species, composition of the atherogenic diet, and length of time fed the atherogenic diet. The myocardial lesions are remarkably similar to those described in human beings in terms of location and gross and microscopic characteristics. The characteristics of coronary artery atherosclerosis, including the occurrence of thrombosis, severe stenosis, mineralization, atheronecrosis, and sterol clefts, especially in animals fed the atherogenic diets for longer periods of time, also closely resemble those of the arterial lesions found in human beings. The greatest prevalence of myocardial infarcts was found in rhesus monkeys fed a cholesterol-containing diet with 40% of calories supplied by peanut oil and in cynomolgus macaques from Malaya that were fed the same amount of cholesterol with 40% of calories from lard. Electrocardiographic abnormalities as well as the occurrence of unexpected and relatively sudden death in several of these nonhuman primates are also consistent with signs frequently observed in human beings.
    Matched MeSH terms: Coronary Vessels/pathology
  11. Chian TC, Nassir NM, Ibrahim MI, Yusof AK, Sabarudin A
    Quant Imaging Med Surg, 2017 Feb;7(1):48-58.
    PMID: 28275559 DOI: 10.21037/qims.2017.02.02
    BACKGROUND: This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols.

    METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.

    RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.

    CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

    Matched MeSH terms: Coronary Vessels
  12. Colangelo LA, Carroll AJ, Perak AM, Gidding SS, Lima JAC, Lloyd-Jones DM
    Psychosom Med, 2024 01 09;86(2):60-71.
    PMID: 38193784 DOI: 10.1097/PSY.0000000000001277
    OBJECTIVE: Depression is a risk factor for coronary heart disease and left ventricular hypertrophy (LVH) is a potent predictor of coronary heart disease events. Whether depression is associated with LVH has received limited investigation. This study assessed cross-sectional and 20-year longitudinal associations of depressive symptoms with LVH outcomes after accounting for important known confounders.

    METHODS: From 5115 participants enrolled in 1985-1986 in the Coronary Artery Risk Development in Young Adults Study, 2533 had serial measures of depressive symptoms and subsequent echocardiography to measure normal LV geometry, concentric remodeling, and LVH. The primary exposure variable was trajectories of the Center for Epidemiologic Studies Depression (CES-D) scale score from 1990-1991 to 2010-2011. Multivariable polytomous logistic regression was used to assess associations of trajectories with a composite LV geometry outcome created using echocardiogram data measured in 2010-2011 and 2015-2016. Sex-specific conflicting results led to exploratory models that examined potential importance of testosterone and sex hormone-binding globulin.

    RESULTS: Overall CES-D and Somatic subscale trajectories had significant associations with LVH for female participants only. Odds ratios for the subthreshold (mean CES-D ≈ 14) and stable (mean CES-D ≈ 19) groups were 1.49 (95% confidence interval = 1.05-2.13) and 1.88 (95% confidence interval = 1.16-3.04), respectively. For female participants, sex hormone-binding globulin was inversely associated with LVH, and for male participants, bioavailable testosterone was positively associated with concentric geometry.

    CONCLUSIONS: Findings from cross-sectional and longitudinal regression models for female participants, but not male ones, and particularly for Somatic subscale trajectories suggested a plausible link among depression, androgens, and LVH. The role of androgens to the depression-LVH relation requires additional investigation in future studies.

    Matched MeSH terms: Coronary Vessels
  13. Ding CCA, Dokos S, Bakir AA, Zamberi NJ, Liew YM, Chan BT, et al.
    Biomed Eng Online, 2024 Feb 22;23(1):24.
    PMID: 38388416 DOI: 10.1186/s12938-024-01206-2
    Aortic stenosis, hypertension, and left ventricular hypertrophy often coexist in the elderly, causing a detrimental mismatch in coupling between the heart and vasculature known as ventricular-vascular (VA) coupling. Impaired left VA coupling, a critical aspect of cardiovascular dysfunction in aging and disease, poses significant challenges for optimal cardiovascular performance. This systematic review aims to assess the impact of simulating and studying this coupling through computational models. By conducting a comprehensive analysis of 34 relevant articles obtained from esteemed databases such as Web of Science, Scopus, and PubMed until July 14, 2022, we explore various modeling techniques and simulation approaches employed to unravel the complex mechanisms underlying this impairment. Our review highlights the essential role of computational models in providing detailed insights beyond clinical observations, enabling a deeper understanding of the cardiovascular system. By elucidating the existing models of the heart (3D, 2D, and 0D), cardiac valves, and blood vessels (3D, 1D, and 0D), as well as discussing mechanical boundary conditions, model parameterization and validation, coupling approaches, computer resources and diverse applications, we establish a comprehensive overview of the field. The descriptions as well as the pros and cons on the choices of different dimensionality in heart, valve, and circulation are provided. Crucially, we emphasize the significance of evaluating heart-vessel interaction in pathological conditions and propose future research directions, such as the development of fully coupled personalized multidimensional models, integration of deep learning techniques, and comprehensive assessment of confounding effects on biomarkers.
    Matched MeSH terms: Coronary Vessels
  14. Govindaraju K, Kamangar S, Badruddin IA, Viswanathan GN, Badarudin A, Salman Ahmed NJ
    Atherosclerosis, 2014 Apr;233(2):630-635.
    PMID: 24549189 DOI: 10.1016/j.atherosclerosis.2014.01.043
    Functional assessment of a coronary artery stenosis severity is generally assessed by fractional flow reserve (FFR), which is calculated from pressure measurements across the stenosis. The purpose of this study is to investigate the effect of porous media of the stenosed arterial wall on this diagnostic parameter. To understand the role of porous media on the diagnostic parameter FFR, a 3D computational simulations of the blood flow in rigid and porous stenotic artery wall models are carried out under steady state and transient conditions for three different percentage area stenoses (AS) corresponding to 70% (moderate), 80% (intermediate), and 90% (severe). Blood was modeled as a non Newtonian fluid. The variations of pressure drop across the stenosis and diagnostic parameter were studied in both models. The FFR decreased in proportion to the increase in the severity of the stenosis. The relationship between the percentage AS and the FFR was non linear and inversely related in both the models. The cut-off value of 0.75 for FFR was observed at 81.89% AS for the rigid artery model whereas 83.61% AS for the porous artery wall model. This study demonstrates that the porous media consideration on the stenotic arterial wall plays a substantial role in defining the cut-off value of FFR. We conclude that the effect of porous media on FFR, could lead to misinterpretation of the functional severity of the stenosis in the region of 81.89 %-83.61% AS.
    Matched MeSH terms: Coronary Vessels/physiopathology; Coronary Vessels/ultrastructure*
  15. Govindaraju K, Badruddin IA, Viswanathan GN, Ramesh SV, Badarudin A
    Phys Med, 2013 May;29(3):225-32.
    PMID: 22704601 DOI: 10.1016/j.ejmp.2012.03.008
    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.
    Matched MeSH terms: Coronary Vessels/physiopathology*; Coronary Vessels/radiography; Coronary Vessels/ultrasonography
  16. Govindaraju K, Viswanathan GN, Badruddin IA, Kamangar S, Salman Ahmed NJ, Al-Rashed AA
    Comput Methods Biomech Biomed Engin, 2016 Nov;19(14):1541-9.
    PMID: 27052093 DOI: 10.1080/10255842.2016.1170119
    This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
    Matched MeSH terms: Coronary Vessels/physiopathology*
  17. Guarini G, Kiyooka T, Ohanyan V, Pung YF, Marzilli M, Chen YR, et al.
    Basic Res Cardiol, 2016 May;111(3):29.
    PMID: 27040114 DOI: 10.1007/s00395-016-0547-4
    Mitochondrial dysfunction in obesity and diabetes can be caused by excessive production of free radicals, which can damage mitochondrial DNA. Because mitochondrial DNA plays a key role in the production of ATP necessary for cardiac work, we hypothesized that mitochondrial dysfunction, induced by mitochondrial DNA damage, uncouples coronary blood flow from cardiac work. Myocardial blood flow (contrast echocardiography) was measured in Zucker lean (ZLN) and obese fatty (ZOF) rats during increased cardiac metabolism (product of heart rate and arterial pressure, i.v. norepinephrine). In ZLN increased metabolism augmented coronary blood flow, but in ZOF metabolic hyperemia was attenuated. Mitochondrial respiration was impaired and ROS production was greater in ZOF than ZLN. These were associated with mitochondrial DNA (mtDNA) damage in ZOF. To determine if coronary metabolic dilation, the hyperemic response induced by heightened cardiac metabolism, is linked to mitochondrial function we introduced recombinant proteins (intravenously or intraperitoneally) in ZLN and ZOF to fragment or repair mtDNA, respectively. Repair of mtDNA damage restored mitochondrial function and metabolic dilation, and reduced ROS production in ZOF; whereas induction of mtDNA damage in ZLN reduced mitochondrial function, increased ROS production, and attenuated metabolic dilation. Adequate metabolic dilation was also associated with the extracellular release of ADP, ATP, and H2O2 by cardiac myocytes; whereas myocytes from rats with impaired dilation released only H2O2. In conclusion, our results suggest that mitochondrial function plays a seminal role in connecting myocardial blood flow to metabolism, and integrity of mtDNA is central to this process.
    Matched MeSH terms: Coronary Vessels/metabolism; Coronary Vessels/physiopathology*
  18. Gurpreet S, Vendargon SJ, Syed Rasul SH
    Med J Malaysia, 2019 12;74(6):549-550.
    PMID: 31929487
    We understand that autoimmune disorders such as Systemic Lupus Erythematosus increases the likelihood of developing coronary heart disease. However, its implications on patients undergoing cardiac surgery is not well understood. Here we present a female patient with SLE who developed coronary artery disease at a young age and underwent coronary artery bypass graft surgery. As SLE is associated with vasculitis, we wanted to understand regarding the choice of conduit as well as its long term patency. Also whether percutaneous angioplasty has a role to play in patients with SLE.
    Matched MeSH terms: Coronary Vessels/physiopathology*; Coronary Vessels/surgery
  19. Hermawan H, Mantovani D
    Acta Biomater, 2013 Nov;9(10):8585-92.
    PMID: 23665503 DOI: 10.1016/j.actbio.2013.04.027
    Biodegradable stents are considered to be a recent innovation, and their feasibility and applicability have been proven in recent years. Research in this area has focused on materials development and biological studies, rather than on how to transform the developed biodegradable materials into the stent itself. Currently available stent technology, the laser cutting-based process, might be adapted to fabricate biodegradable stents. In this work, the fabrication, characterization and testing of biodegradable Fe-Mn stents are described. A standard process for fabricating and testing stainless steel 316L stents was referred to. The influence of process parameters on the physical, metallurgical and mechanical properties of the stents, and the quality of the produced stents, were investigated. It was found that some steps of the standard process such as laser cutting can be directly applied, but changes to parameters are needed for annealing, and alternatives are needed to replace electropolishing.
    Matched MeSH terms: Coronary Vessels/drug effects*; Coronary Vessels/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links