CASE PRESENTATION: This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.
CONCLUSIONS: Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.
Results: A significant difference (p < 0.001) of mean debonding force was found between different types of teeth in vivo. Clinically, ARI scores were not significantly different (p = 0.921) between different groups, but overall higher scores were predominant.
Conclusion: Bracket debonding force should be measured on the same tooth from the same arch as the significant difference of mean debonding force exists between similar teeth of the upper and lower arches. The insignificant bracket failure pattern with higher ARI scores confirms less enamel damage irrespective of tooth types.
OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.
METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.
RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.
CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.