Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Muhammad R, Johann KF, Saladina JJ, Mohd Latar NH, Niza ASS
    Med J Malaysia, 2013 Jun;68(3):204-7.
    PMID: 23749007 MyJurnal
    Treatment for breast cancer has improved dramatically over the decades. Nevertheless, modified radical mastectomy with axillary dissection remains the standard treatment for most patients, especially those with big tumours. The conventional technology is to use diathermy to cut and coagulate blood vessels. The Ultracision dissector has been widely used in laparoscopic surgery and is documented to be safe and fast for cutting and coagulating tissue. The aim of this study is to compare ultracision to electrocautery, looking in terms of amount of post operative drainage, duration of drain days, seroma formation and other complications.
    Matched MeSH terms: Electrocoagulation
  2. Asaithambi P, Aziz ARA, Sajjadi B, Daud WMABW
    Environ Sci Pollut Res Int, 2017 Feb;24(6):5168-5178.
    PMID: 27221586 DOI: 10.1007/s11356-016-6909-5
    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm(2)), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm(2), electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.
    Matched MeSH terms: Electrocoagulation/methods*
  3. Al-Raad AA, Hanafiah MM
    J Environ Manage, 2021 Dec 15;300:113696.
    PMID: 34509809 DOI: 10.1016/j.jenvman.2021.113696
    Electrocoagulation (ECoag) technique has shown considerable potential as an effective method in separating different types of pollutants (including inorganic pollutants) from various sources of water at a lower cost, and that is environmentally friendly. The EC method's performance depends on several significant parameters, including current density, reactor geometry, pH, operation time, the gap between electrodes, and agitation speed. There are some challenges related to the ECoag technique, for example, energy consumption, and electrode passivation as well as its implementation at a larger scale. This review highlights the recent studies published about ECoag capacity to remove inorganic pollutants (including salts), the emerging reactors, and the effect of reactor geometry designs. In addition, this paper highlights the integration of the ECoag technique with other advanced technologies such as microwave and ultrasonic to achieve higher removal efficiencies. This paper also presents a critical discussion of the major and minor reactions of the electrocoagulation technique with several significant operational parameters, emerging designs of the ECoag cell, operating conditions, and techno-economic analysis. Our review concluded that optimizing the operating parameters significantly enhanced the efficiency of the ECoag technique and reduced overall operating costs. Electrodes geometry has been recommended to minimize the passivation phenomenon, promote the conductivity of the cell, and reduce energy consumption. In this review, several challenges and gaps were identified, and insights for future development were discussed. We recommend that future studies investigate the effect of other emerging parameters like perforated and ball electrodes on the ECoag technique.
    Matched MeSH terms: Electrocoagulation
  4. Balasubramanian N, Kojima T, Basha CA, Srinivasakannan C
    J Hazard Mater, 2009 Aug 15;167(1-3):966-9.
    PMID: 19231076 DOI: 10.1016/j.jhazmat.2009.01.081
    Removal of arsenic from aqueous solution was carried out using electrocoagulation. Experiments were conducted using mild steel sacrificial anode covering wide range in operating conditions to assess the removal efficiency. The maximum arsenic removal efficiency was recorded as 94% under optimum condition. The electrocoagulation mechanism of arsenic removal has been developed to understand the effect of applied charge and electrolyte pH on arsenic removal efficiency. Further the experimental data were tested with different adsorption isotherm model to describe the electrocoagulation process.
    Matched MeSH terms: Electrocoagulation/methods*
  5. Naje AS, Ajeel MA, Ali IM, Al-Zubaidi HAM, Alaba PA
    Water Sci Technol, 2019 Aug;80(3):458-465.
    PMID: 31596257 DOI: 10.2166/wst.2019.289
    In this work, landfill leachate treatment by electrocoagulation process with a novel rotating anode reactor was studied. The influence of rotating anode speed on the removal efficiency of chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS) of raw landfill leachate was investigated. The influence of operating parameters like leachate pH, leachate temperature, current, and inter-distance between the cathode rings and anode impellers on the electrocoagulation performance were also investigated. The results revealed the optimum rotating speed is 150 rpm and increasing the rotating speed above this value led to reducing process performance. The leachate electrocoagulation treatment process favors the neutral medium and the treatment performance increases with increasing current intensity. Furthermore, the electrocoagulation treatment performance improves with increasing leachate temperature. However, the performance reduces with increasing inter-electrode distance.
    Matched MeSH terms: Electrocoagulation
  6. Emami Moghaddam SA, Harun R, Mokhtar MN, Zakaria R
    Biomed Res Int, 2018;2018:6563196.
    PMID: 30643814 DOI: 10.1155/2018/6563196
    The interest in utilizing algae for wastewater treatment has been increased due to many advantages. Algae-wastewater treatment system offers a cost-efficient and environmentally friendly alternative to conventional treatment processes such as electrocoagulation and flocculation. In this biosystem, algae can assimilate nutrients in the wastewater for their growth and simultaneously capture the carbon dioxide from the atmosphere during photosynthesis resulting in a decrease in the greenhouse gaseousness. Furthermore, the algal biomass obtained from the treatment process could be further converted to produce high value-added products. However, the recovery of free suspended algae from the treated effluent is one of the most important challenges during the treatment process as the current methods such as centrifugation and filtration are faced with the high cost. Immobilization of algae is a suitable approach to overcome the harvesting issue. However, there are some drawbacks with the common immobilization carriers such as alginate and polyacrylamide related to low stability and toxicity, respectively. Hence, it is necessary to apply a new carrier without the mentioned problems. One of the carriers that can be a suitable candidate for the immobilization is zeolite. To date, various types of zeolite have been used for the immobilization of cells of bacteria and yeast. If there is any possibility to apply them for the immobilization of algae, it needs to be considered in further studies. This article reviews cell immobilization technique, biomass immobilization onto zeolites, and algal immobilization with their applications. Furthermore, the potential application of zeolite as an ideal carrier for algal immobilization has been discussed.
    Matched MeSH terms: Electrocoagulation
  7. Bashir MJ, Mau Han T, Jun Wei L, Choon Aun N, Abu Amr SS
    Water Sci Technol, 2016;73(11):2704-12.
    PMID: 27232407 DOI: 10.2166/wst.2016.123
    As the ponding system used to treat palm oil mill effluent (POME) frequently fails to satisfy the discharge standard in Malaysia, the present study aimed to resolve this problem using an optimized electrocoagulation process. Thus, a central composite design (CCD) module in response surface methodology was employed to optimize the interactions of process variables, namely current density, contact time and initial pH targeted on maximum removal of chemical oxygen demand (COD), colour and turbidity with satisfactory pH of discharge POME. The batch study was initially designed by CCD and statistical models of responses were subsequently derived to indicate the significant terms of interactive process variables. All models were verified by analysis of variance showing model significances with Prob > F < 0.01. The optimum performance was obtained at the current density of 56 mA/cm(2), contact time of 65 min and initial pH of 4.5, rendering complete removal of colour and turbidity with COD removal of 75.4%. The pH of post-treated POME of 7.6 was achieved, which is suitable for direct discharge. These predicted outputs were subsequently confirmed by insignificant standard deviation readings between predicted and actual values. This optimum condition also permitted the simultaneous removal of NH3-N, and various metal ions, signifying the superiority of the electrocoagulation process optimized by CCD.
    Matched MeSH terms: Electrocoagulation
  8. Al Aradi IK
    Dermatol Surg, 2006 Oct;32(10):1244-50.
    PMID: 17034373
    Management of periorbital syringomas is problematic and avoided by many inexperienced physicians. The medical literature presently prefers CO(2) laser resurfacing to many other modalities, but the subject of electrosurgery has not been well explored.
    Matched MeSH terms: Electrocoagulation/instrumentation*
  9. Leung AK, Barankin B, Leong KF, Hon KL
    Drugs Context, 2018;7:212563.
    PMID: 30622585 DOI: 10.7573/dic.212563
    Background: Penile warts are the most common sexually transmitted disease in males. Clinicians should be familiar with the proper evaluation and management of this common condition.

    Objective: To provide an update on the current understanding, evaluation, and management of penile warts.

    Methods: A PubMed search was completed in Clinical Queries using the key terms 'penile warts' and 'genital warts'. The search strategy included meta-analyses, randomized controlled trials, clinical trials, observational studies, and reviews.

    Results: Penile warts are caused by human papillomavirus (HPV), notably HPV-6 and HPV-11. Penile warts typically present as asymptomatic papules or plaques. Lesions may be filiform, exophytic, papillomatous, verrucous, hyperkeratotic, cerebriform, fungating, or cauliflower-like. Approximately one-third of penile warts regress without treatment and the average duration prior to resolution is approximately 9 months. Active treatment is preferable to watchful observation to speed up clearance of the lesions and to assuage fears of transmission and autoinoculation. Patient-administered therapies include podofilox (0.5%) solution or gel, imiquimod 3.75 or 5% cream, and sinecatechins (polypheron E) 15% ointment. Clinician-administered therapies include podophyllin, cryotherapy, bichloroacetic or trichloroacetic acid, oral cimetidine, surgical excision, electrocautery, and carbon dioxide laser therapy. Patients who do not respond to first-line treatments may respond to other therapies or a combination of treatment modalities. Second-line therapies include topical/intralesional/intravenous cidofovir, topical 5-fluorouracil, and topical ingenol mebutate.

    Conclusion: No single treatment has been shown to be consistently superior to other treatment modalities. The choice of the treatment method should depend on the physician's comfort level with the various treatment options, the patient's preference and tolerability of treatment, and the number and severity of lesions. The comparative efficacy, ease of administration, adverse effects, cost, and availability of the treatment modality should also be taken into consideration.

    Matched MeSH terms: Electrocoagulation
  10. Al-Raad AA, Hanafiah MM, Naje AS, Ajeel MA
    Environ Pollut, 2020 Oct;265(Pt B):115049.
    PMID: 32599327 DOI: 10.1016/j.envpol.2020.115049
    In this study, a novel rotating anode-based reactor (RAR) was designed to investigate its effectiveness in removing dissolved salts (i.e., Br-, Cl-, TDS, and SO42-) from saline water samples. Two configurations of an impeller's rotating anode with various operation factors, such as operating time (min), rotating speed (rpm), current density (mA/cm2), temperature (°C), pH, and inter-electrode space (cm), were used in the desalination process. The total cost consumed was calculated on the basis of the energy consumption and aluminum (Al) used in the desalination. In this respect, operating costs were calculated using optimal operating conditions. Salinity was removed electrochemically from saline water through electrocoagulation (EC). Results showed that the optimal adjustments for treating saline water were carried out at the following conditions: 150 and 75 rpm rotating speeds for the impeller's rod anode and plate anode designs, respectively; 2 mA/cm2 current density (I), 1 cm2 inter-electrode space, 25 °C temperature, 10 min operation time, and pH 8. The results indicated that EC technology with impeller plates of rotating anode can be considered a very cost-effective technique for treating saline water.
    Matched MeSH terms: Electrocoagulation
  11. Aliaga Ramos J, Arantes V, Abdul Rani R, Yoshida N
    Endosc Int Open, 2020 Dec;8(12):E1741-E1747.
    PMID: 33269305 DOI: 10.1055/a-1265-6598
    Background and study aims  Submucosal (SM) injection is a critical step in endoscopic submucosal dissection (ESD). In Japan, use of viscous solutions such as sodium hyaluronate are recommended; the commercially product available is MucoUp (Seikagaku Co. and Boston Scientific Japan Co., Japan). Nevertheless, MucoUp is expensive and unavailable in many Western countries. For the past 8 years, we have been using low-cost sterile teardrops solution composed of 0.4 % sodium hyaluronate (Adaptis Fresh, Legrand Laboratory, Brazil). This solution is readily available in drugstores with a cost of approximately US$ 10.00 for each 10-cc bottle. The aim of this study was to present the clinical outcome with off-label sodium hyaluronate use for SM injection in gastric ESD. Patients and methods  A single-center retrospective study of collected data investigating consecutive patients that underwent gastric ESD between 2012 and 2019. ESD was performed using 0.4 % sodium hyaluronate teardrop for SM injection and Flush Knife BT 2.5 (Fujifilm Co., Japan). The following data were analyzed: clinical-pathological features, en-bloc, R0 and curative resection rate, procedure duration, adverse events, and clinical outcome. Results  ESD was performed with sodium hyaluronate for submucosal injection in 78 patients. The en-bloc resection rate and R0 resection rate were 96.1 % and 92.3 %, respectively. The curative resection rate for epithelial lesions was 83.8 %. Adverse events occurred in 5 cases (6.3 %): delayed bleeding (3.8 %, 3 cases) and perforation (2.5 %, 2 cases); all managed successfully by clipping and thermal coagulation. The mean volume of sodium hyaluronate solution used per patient was 10 cc (SD: ± 8 cc). During follow-up (mean: 17 months; SD: ± 14.5 months), two patients developed metachronous lesions (2.5 %). Conclusions  Off-label use of teardrops with 0.4 % sodium hyaluronate for submucosal injection was demonstrated to be safe and able to provide an effective submucosal cushion that facilitates SM dissection in gastric ESD procedures.
    Matched MeSH terms: Electrocoagulation
  12. Bonakdari H, Ebtehaj I, Akhbari A
    Water Sci Technol, 2017 Jun;75(12):2791-2799.
    PMID: 28659519 DOI: 10.2166/wst.2017.158
    Electrocoagulation (EC) is employed to investigate the energy consumption (EnC) of synthetic wastewater. In order to find the best process conditions, the influence of various parameters including initial pH, initial dye concentration, applied voltage, initial electrolyte concentration, and treatment time are investigated in this study. EnC is considered the main criterion of process evaluation in investigating the effect of the independent variables on the EC process and determining the optimum condition. Evolutionary polynomial regression is combined with a multi-objective genetic algorithm (EPR-MOGA) to present a new, simple and accurate equation for estimating EnC to overcome existing method weaknesses. To survey the influence of the effective variables, six different input combinations are considered. According to the results, EPR-MOGA Model 1 is the most accurate compared to other models, as it has the lowest error indices in predicting EnC (MARE = 0.35, RMSE = 2.33, SI = 0.23 and R2 = 0.98). A comparison of EPR-MOGA with reduced quadratic multiple regression methods in terms of feasibility confirms that EPR-MOGA is an effective alternative method. Moreover, the partial derivative sensitivity analysis method is employed to analyze the EnC variation trend according to input variables.
    Matched MeSH terms: Electrocoagulation
  13. Goh LC, Wan MH, Shashi G, Elangkumaran S
    Iran J Otorhinolaryngol, 2018 Jul;30(99):225-229.
    PMID: 30083529
    Introduction: This study aims to report a rare case of a respiratory epithelial adenomatoid hamartoma (REAH) of the lateral nasal wall that had initially presented as a fungating mass, similar to that of a sinonasal malignancy, and its complete removal from the lateral nasal wall.

    Case Report: We report the case of a 58-year-old woman who presented to us with a chief complaint of recurrent right-sided epistaxis and nasal blockage for the past 4 months, which was progressively worsening. Histopathological examination confirmed the presence of a REAH instead of a sinonasal malignancy. The tumor was surgically excised from the lateral nasal wall using electrocautery under endoscopic guidance. The patient was then carefully followed-up after surgery, and the wound was successfully healed 3 months after the initial surgery. There was no evidence of recurrence 6 months after the initial surgery.

    Conclusion: This case demonstrates the rare presentation of a REAH, which had arisen from the lateral nasal wall. Clinically, it is difficult to distinguish a REAH from a more notorious mass such as a sinonasal malignancy. Therefore, biopsy is mandatory in all cases of lateral nasal mass in order to rule out malignancy before confirming nasal REAH. Fortunately, as seen in this case, a lateral nasal REAH, once diagnosed, can be safely and easily removed from the lateral nasal wall using electrocautery with good surgical outcomes and a low rate of recurrence.

    Matched MeSH terms: Electrocoagulation
  14. Lim YH, Ng SP, Ng PH, Tan AE, Jamil MA
    J Obstet Gynaecol Res, 2007 Dec;33(6):855-62.
    PMID: 18001454
    Ectopic pregnancy is conventionally managed by laparoscopic salpingectomy. Electrocautery has been used widely to secure hemostasis during salpingectomy. However, this method is associated with a risk of thermal injury to the visceral organs. Endoloop, a pre-tied suture used in laparoscopic surgery may be an alternative treatment tool and its potential use in the management of ectopic pregnancy is explored here. Our study aims to compare the effectiveness of the endoloop technique to electrocautery during laparoscopic salpingectomy for tubal pregnancy.
    Matched MeSH terms: Electrocoagulation*
  15. Bani-Melhem K, Elektorowicz M, Tawalbeh M, Al Bsoul A, El Gendy A, Kamyab H, et al.
    Chemosphere, 2023 Oct;339:139693.
    PMID: 37536541 DOI: 10.1016/j.chemosphere.2023.139693
    Treating and reusing wastewater has become an essential aspect of water management worldwide. However, the increase in emerging pollutants such as polycyclic aromatic hydrocarbons (PAHs), which are presented in wastewater from various sources like industry, roads, and household waste, makes their removal difficult due to their low concentration, stability, and ability to combine with other organic substances. Therefore, treating a low load of wastewater is an attractive option. The study aimed to address membrane fouling in the submerged membrane bioreactor (SMBR) used for wastewater treatment. An aluminum electrocoagulation (EC) device was combined with SMBR as a pre-treatment to reduce fouling. The EC-SMBR process was compared with a conventional SMBR without EC, fed with real grey water. To prevent impeding biological growth, low voltage gradients were utilized in the EC deviceThe comparison was conducted over 60 days with constant transmembrane pressure and infinite solid retention time (SRT). In phase I, when the EC device was operated at a low voltage gradient (0.64 V/cm), no significant improvement in the pollutants removal was observed in terms of color, turbidity, and chemical oxygen demand (COD). Nevertheless, during phase II, a voltage gradient of 1.26 V/cm achieved up to 100%, 99.7%, 92%, 94.1%, and 96.5% removals in the EC-SMBR process in comparison with 95.1%, 95.4%, 85%, 91.7% and 74.2% removals in the SMBR process for turbidity, color, COD, ammonia nitrogen (NH3-N), total phosphorus (TP), respectively. SMBR showed better anionic surfactant (AS) removal than EC-SMBR. A voltage gradient of 0.64 V/cm in the EC unit significantly reduced fouling by 23.7%, while 1.26 V/cm showed inconsistent results. Accumulation of Al ions negatively affected membrane performance. Low voltage gradients in EC can control SMBR fouling if Al concentration is controlled. Future research should investigate EC-SMBR with constant membrane flux for large-scale applications, considering energy consumption and operating costs.
    Matched MeSH terms: Electrocoagulation
  16. Danial R, Sobri S, Abdullah LC, Mobarekeh MN
    Chemosphere, 2019 Oct;233:559-569.
    PMID: 31195261 DOI: 10.1016/j.chemosphere.2019.06.010
    In this study, the performance of glyphosate removal in an electrocoagulation batch with two electrodes formed by the same metal type, consisting of aluminum, iron, steel and copper have been compared. The aim of this study intends to remove glyphosate from an aqueous solution by an electrocoagulation process using metal electrode plates, which involves electrogeneration of metal cations as coagulant agents. The production of metal cations showed an ability to bind together to form aggregates of flocs composed of a combination of glyphosate and metal oxide. Electrocoagulation using aluminum electrodes indicated a high percentage removal of glyphosate, 94.25%; followed by iron electrodes, 88.37%; steel electrodes, 62.82%; and copper electrodes, 46.69%. The treated aqueous solution was then analyzed by Fourier Transform Infrared Spectroscopy. Percentages of Carbon, Hydrogen, Nitrogen, Sulfur remaining in the treated aqueous solution after the electrocoagulation process have been determined. The treated water and sludge were characterized and the mechanism of the overall process was concluded as an outcome. An X-Ray Diffraction analysis of dried sludge confirmed that new polymeric compounds were formed during the treatment. The sludge composed of new compounds were also verified the removals. This study revealed that an electrocoagulation process using metal electrodes is reliable and efficient.
    Matched MeSH terms: Electrocoagulation/methods
  17. Naje AS, Chelliapan S, Zakaria Z, Abbas SA
    J Environ Manage, 2016 Jul 1;176:34-44.
    PMID: 27039362 DOI: 10.1016/j.jenvman.2016.03.034
    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.
    Matched MeSH terms: Electrocoagulation
  18. Huda N, Raman AAA, Bello MM, Ramesh S
    J Environ Manage, 2017 Dec 15;204(Pt 1):75-81.
    PMID: 28865309 DOI: 10.1016/j.jenvman.2017.08.028
    The main problem of landfill leachate is its diverse composition comprising many persistent organic pollutants which must be removed before being discharge into the environment. This study investigated the treatment of raw landfill leachate using electrocoagulation process. An electrocoagulation system was designed with iron as both the anode and cathode. The effects of inter-electrode distance, initial pH and electrolyte concentration on colour and COD removals were investigated. All these factors were found to have significant effects on the colour removal. On the other hand, electrolyte concentration was the most significant parameter affecting the COD removal. Numerical optimization was also conducted to obtain the optimum process performance. Under optimum conditions (initial pH: 7.73, inter-electrode distance: 1.16 cm, and electrolyte concentration (NaCl): 2.00 g/L), the process could remove up to 82.7% colour and 45.1% COD. The process can be applied as a pre-treatment for raw leachates before applying other appropriate treatment technologies.
    Matched MeSH terms: Electrocoagulation/methods*
  19. Nasution MA, Yaakob Z, Ali E, Tasirin SM, Abdullah SR
    J Environ Qual, 2011 Jul-Aug;40(4):1332-9.
    PMID: 21712603 DOI: 10.2134/jeq2011.0002
    Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively.
    Matched MeSH terms: Electrocoagulation/instrumentation; Electrocoagulation/methods*
  20. Rajendren, S. K., Krishnan, K., Ganesh, T. N., Roslan, N. S., Hashim, N. A., Mohamad, M. A.
    Jurnal Veterinar Malaysia, 2019;31(2):19-22.
    MyJurnal
    A 5-year-old Mongrel was brought presented with the complaint of having serosanguineous discharge from penis for a month since adoption. Physical examination revealed cauliflower-like mass at the bulbus glandis. Presence of numerous anisokaryotic and anisocytotic round to oval histiocytes with multivacuolated cytoplasm from cytology, an evidence of canine transmissibale venereal tumour (CTVT). The mass was successfully surgically resected using electrocautery and was in remission for 12 months (since January 2019).
    Matched MeSH terms: Electrocoagulation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links