Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Yeap JS, Wallace AL
    J Shoulder Elbow Surg, 2003 Sep-Oct;12(5):506-9.
    PMID: 14564278 DOI: 10.1016/S1058-2746(03)00168-X
    Matched MeSH terms: External Fixators*
  2. Tan, B. B., Shanmugam, R., Chua, Y. P., Hossain, G., Saw, A.
    Malays Orthop J, 2014;8(2):35-39.
    MyJurnal
    Taylor’s spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness (3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.
    Matched MeSH terms: External Fixators
  3. Tan B, Shanmugam R, Gunalan R, Chua Y, Hossain G, Saw A
    Malays Orthop J, 2014 Jul;8(2):35-9.
    PMID: 25279090 DOI: 10.5704/MOJ.1407.012
    Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness (3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.
    Matched MeSH terms: External Fixators
  4. Subash Y
    Malays Orthop J, 2021 Mar;15(1):48-54.
    PMID: 33880148 DOI: 10.5704/MOJ.2103.008
    Introduction: Fractures of the proximal tibia are high velocity injuries often associated with soft tissue compromise especially in the type V and VI fracture patterns. Dual plating is the preferred treatment option for these injuries but not in a setting where there is extensive soft tissue injury, as this can lead to problems with wound healing. The aim of this study was to evaluate the functional outcome following hybrid external fixation in the management of Schatzkers type V and VI fractures.

    Materials and Methods: A total of 30 patients with type V and VI proximal tibial fractures who presented between January 2012 to January 2015 were managed with hybrid external fixation and were followed-up for a period of 3 years.

    Results: The mean age of the patients was 42.26 years with the left knee being more commonly affected. Schatzkers type V was the more common fracture type seen. The mean time to union was 12.06 weeks and the average range of motion achieved was 0 to 100°. The mean Rasmussens functional score was 25.4 at last follow-up and we had excellent results in 5 patients and good results in 22 patients.

    Conclusion: Through this study, we conclude that the hybrid external fixation is an excellent option in the type V and VI fractures with extensive soft tissue compromise. It is easy to apply, facilitates early mobilisation of the joint and gives good functional results.

    Matched MeSH terms: External Fixators
  5. Siti Nazira Masrom, Mohd Hariri Arifin, Abd Rahim Harun, Abdul Rahim Samsudin
    Sains Malaysiana, 2011;40:1223-1229.
    Survei keberintangan geoelektrik ini telah dijalankan di kawasan Bukit Tenggek, Setiu, Terengganu untuk mengesan kemungkinan wujudnya terowong lama yang dipercayai berada di kawasan berkenaan. Kaedah keberintangan geoelektrik ini bukanlah asing dan didapati amat berkesan di dalam eksplorasi mencari bahan arkeologi dan struktur terkambus di bawah tanah (terowong dan bahan artifak). Survei keberintangan geoelektrik ini dijalankan dengan menggunakan peralatan ABEM Terrameter SAS1000 dan susun atur elektrod jenis Wenner. Kawasan kajian terletak di kawasan lembah yang lembap dan terdapat anak sungai yang merentasi kawasan tersebut. Imej keberintangan 2-D menunjukkan wujudnya beberapa kawasan beranomali yang boleh dikaitkan dengan struktur yang dicari. Nilai keberintangan yang rendah mewakili kawasan yang dianggarkan wujudnya terowong lama. Manakala anomali yang menunjukkan bentuk gugusan dianggarkan berasosiasi dengan lokasi tong/bahan artifak. Profil keberintangan 3-D menunjukkan anomali yang mungkin disebabkan oleh wujudnya satu terowong mendatar dan dua terowong menegak. Namun, kerja galicari perlu dilakukan bagi menentukan punca sebenar anomali tersebut.
    Matched MeSH terms: External Fixators
  6. Siow YS, Ahmad TS, Goh SY
    Hand Surg, 1999 Dec;4(2):167-174.
    PMID: 11089175
    Three patients with severe fixed flexion deformity of the fingers caused by trauma were reported. As an alternative treatment, a new mini external fixator was used to correct the deformities. The use of this device has made treatment of contractures simpler and more predictable. Gradual distraction and straightening was applied to loosen and extend the joints, followed by a period of mobilisation while still on the device. In all the three patients, this experimental device and approach led to improvement of the fixed flexion deformities. With use of this device, surgical release may not be necessary.
    Matched MeSH terms: External Fixators
  7. Shahrulazua, A., Ariff, M.S., Aziz, M.A.
    Malays Orthop J, 2010;4(1):35-38.
    MyJurnal
    Fat embolism syndrome is a well-recognised sequela of long bone trauma as well as intramedullary orthopaedic procedures. However, it has rarely been described following manipulation, reduction of fracture, and application of external fixator. Furthermore, bilateral ocular blindness is seldom the first manifestation; instead respiratory and other cerebral symptoms being most common. We describe a case with this rare presentation in a patient who underwent a trial of closed reduction, then open reduction of a femur fracture, followed by external fixation performed at day 47 post-initial trauma.
    Matched MeSH terms: External Fixators
  8. Saw, A., Manimaran, S., Faizal S., Bulgiba, A.M.
    Malays Orthop J, 2008;2(1):44-48.
    MyJurnal
    Bone lengthening with distraction osteogenesis involves prolonged application of an external fixator frame. Qualitative and quantitative evaluation of callus has been described using various imaging modalities but there is no simple reliable and readily available method. This study aims to investigate the use of a densitometer to analyze plain radiographic images and correlate them with the rate of new bone formation as represented by the bone healing index. A total of 34 bone lengthening procedures in 29 patients were retrospectively reviewed. We used an X-Rite 301 densitometer to measure densities of new callus on plain radiographs taken at 4 and 8 weeks after surgery. Patients aged below 16y had significantly lower BHIs indicating faster bone healing and shorter duration of treatment. The ratio of radiographic densities between centre and edge of the new bone measured from plain radiographs taken at 8 weeks correlated positively with the eventual BHI of the patient. This method provides a simple and easy way to predict the rate of bone healing at an early stage of treatment and may also allow remedial action to be taken for those with poor progress in bone formation.
    Matched MeSH terms: External Fixators
  9. Saw A, Chan CK, Penafort R, Sengupta S
    Med J Malaysia, 2006 Feb;61 Suppl A:62-5.
    PMID: 17042233
    Patients treated with external fixation for limb reconsturciton or fracture stabilization equire regular and prolongedperiod of pin-tract care involving frequent visits to clinic and dressing traditionally carried out by trained nurses or medical assistants. A simple method of do-it-yourself dressing was introduced in our institution and this study was undertaken to evaluate the effectiveness of the protocol. Sixty patients (40 trauma-related problems and 20 congenital or developmental disorders) were enrolled into the study. Following application of external fixation, the patients and/or their caretakers were taught on how to do pin-site dressing using normal saline or drinking water as cleansing solution on daily basis. Patients were discharged on the second or third post-operative day and were followed-up every two weeks for an average 182 days (range 66 to 379 days) with special attention on identifying pin-tract infection. A simple grading system for pin-tract infections was proposed. Of 40 patients with trauma-related problems. 65% were post-traumatic infections. There were 788 metal-skin interfaces (239 half-pin fixations and 549 tensioned wire fixations. A total 143 metal-skin interface infections (18.1%) involving half-pin sites (41.3%) and tensioned wire sites (58.7%) was noted. Majority were grade I infections (79.7%), 18.8% grade II and only 1.4% grade III. Most infections (81%)were caused by Staphylococcus aureus. Grade I infections were successfully treated with frequent dressing, grade II by adjunctive oral antibiotic but grade III infections required removal of fixator. All eventually healed. Do yourself non-sterile dressing of metal-skin interfaces is a cost-effective method of pin-site care with a low infection rate. The infections were sucessfully treated using guidelines according to the proposed classification of pin-tract infections.
    Matched MeSH terms: External Fixators/microbiology*
  10. Rushdi I, Che-Ahmad A, Abdul-Ghani K, Mohd-Rus R
    Malays Orthop J, 2020 Nov;14(3):57-65.
    PMID: 33403063 DOI: 10.5704/MOJ.2011.010
    Introduction: Distal tibia fractures are frequently associated with an extensive soft tissue injury which then leads to a higher risk of complications such as infection, non-union and eventually poor overall outcome. The purpose of this study is to measure the outcome of distal tibia fractures treated with internal fixation, external fixator or Ilizarov external fixator(IEF). We aim to propose an algorithm for management of distal tibia fractures by evaluating the treatment options, outcomes and risk factors present.

    Material and Methods: This study is a cross-sectional study of all distal tibia fractures treated surgically in Tengku Ampuan Rahimah Hospital, Klang from 1st January 2016 till 30th June 2018. Patient records were reviewed to analyse the outcomes of surgical treatment and risk factors associated with it.

    Results: Ninety-one patients were included with a mean age of 41.5 years (SD = 16.4). Thirty-nine cases (42.9%) were open fractures. Thirty-eight patients (41.8%) were treated with internal fixation, 27 patients (29.7%) were treated with IEF and 26 patients (28.6%) were treated with an external fixator. Among open fractures cases, no significant finding can be concluded when comparing each surgical option and its outcome, although one option was seen better than the other in a particular outcome. Initial skeletal traction or temporary spanning external fixator in close fractures reduced the risk of mal-alignment (p value=0.001). Internal fixation is seen superior to IEF and external fixator in close fractures in term of articular surface reduction (p value = 0.043) and risk of mal-alignment (p value = 0.007).

    Conclusion: There is no single method of fixation that is ideal for all pilon fractures and suitable for all patients. This proposed algorithm can help surgeons in deciding treatment strategies in the challenging management of distal tibia fractures to reduce associated complications.

    Matched MeSH terms: External Fixators
  11. Ranatunga, I.R., Thirumal, M.
    Malays Orthop J, 2010;4(2):34-39.
    MyJurnal
    This is a retrospective review of 18 patients with tibial plateau fractures Schatzker type VI. These cases were performed in our medical centre from January 2003 to December 2004. The Ilizarov technique (Russian technique) using the ring external fixator was the technique performed. Articular reconstruction and joint alignment were achieved with traction and olive wires with washers. One case required percutaneous elevation of the articular surface and bone grafting through a cortical window. Average clinical union was achieved within 4 months of trauma. Mean final knee flexion was 85°, which is compatible with walking. All patients successfully returned to their previous occupations. In conclusion, the Ilizarov technique has been shown to be a good option and a viable tool in the management of these complex and unstable injuries.
    Matched MeSH terms: External Fixators
  12. Ramlee MH, Seng GH, Ros Felip A, Abdul Kadir MR
    Injury, 2021 Aug;52(8):2131-2141.
    PMID: 33745700 DOI: 10.1016/j.injury.2021.03.017
    An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface.
    Matched MeSH terms: External Fixators
  13. Ramlee MH, Gan HS, Daud SA, Abdul Wahab A, Abdul Kadir MR
    J Foot Ankle Surg, 2020 7 1;59(4):664-672.
    PMID: 32600559 DOI: 10.1053/j.jfas.2019.09.006
    Osteoporosis and osteoarthritis are common pathological problems of the human bone tissue. There are some cases of pilon fractures associated with these 2 pathological conditions. In terms of treatment, for a normal and healthy bone with pilon fracture, the use of the Delta external fixator is a favorable option because it can allow early mobilization for patients and provide stability for the healing process. However, the stability of the external fixator differs when there is low bone stiffness, which has not been previously investigated. Therefore, this study was conducted to determine the stability of the external fixator to treat pilon fracture associated with osteoporosis and osteoarthritis, particularly to differentiate the stress distribution and micromovement of fracture fragment. Three-dimensional finite element models of the ankle and foot bones were reconstructed based on the computed tomography datasets. The bones consisted of 5 metatarsal, 3 cuneiform, and 1 each of cuboid, navicular, calcaneus, talus, fibula, and tibia bones. They were assigned with linear isotropic behavior. The ankle joint consisted of ligament and cartilage, and they were assigned with the use of linear links and the Mooney-Rivlin model, respectively. During simulation of the gait cycle, 70 N and 350 N were applied axially to the tibia bone to represent the swing and stance phases, respectively. The metatarsal and calcaneus bones were fixed to prevent any movement of the rigid body. The study found that the greatest von Mises stress value was observed at the pin-bone interface for the osteoporosis (108 MPa) model, followed by the osteoarthritis (87 MPa) and normal (44 MPa) models, during the stance phase. For micromovement, the osteoporosis model had the largest value at 0.26 mm, followed by the osteoarthritis (0.09 mm) and normal (0.03 mm) models. In conclusion, the greatest magnitudes of stress and micromovement were observed for the osteoporosis bone and extra care should be taken to treat pilon fracture associated with this pathological condition.
    Matched MeSH terms: External Fixators
  14. Ramlee MH, Sulong MA, Garcia-Nieto E, Penaranda DA, Felip AR, Kadir MRA
    Med Biol Eng Comput, 2018 Oct;56(10):1925-1938.
    PMID: 29679256 DOI: 10.1007/s11517-018-1830-3
    Pilon fractures can be caused by high-energy vertical forces which may result in long-term patient immobilization. Many experts in orthopedic surgery recommend the use of a Delta external fixator for type III Pilon fracture treatment. This device can promote immediate healing of fractured bone, minimizing the rate of complications as well as allowing early mobilization. The characteristics of different types of the Delta frame have not been demonstrated yet. By using the finite element method, this study was conducted to determine the biomechanical characteristics of six different configurations (Model 1 until Model 6). CT images from the lower limb of a healthy human were used to reconstruct three-dimensional models of foot and ankle bones. All bones were assigned with isotropic material properties and the cartilages were assigned to exhibit hyperelasticity. A linear link was used to simulate 37 ligaments at the ankle joint. Axial loads of 70 and 350 N were applied at the proximal tibia to simulate the stance and swing phase. The metatarsals and calcaneus were fixed distally in order to prevent rigid body motion. A synthetic ankle bone was used to validate the finite element model. The simulated results showed that Delta3 produced the highest relative micromovement (0.09 mm, 7 μm) during the stance and swing phase, respectively. The highest equivalent von Mises stress was found at the calcaneus pin of the Delta4 (423.2 MPa) as compared to others. In conclusion, Delta1 external fixator was the most favorable option for type III Pilon fracture treatment. Graphical abstract ᅟ.
    Matched MeSH terms: External Fixators*
  15. Ramlee MH, Kadir MR, Murali MR, Kamarul T
    Med Eng Phys, 2014 Oct;36(10):1322-30.
    PMID: 25127377 DOI: 10.1016/j.medengphy.2014.05.015
    Pilon fractures are commonly caused by high energy trauma and can result in long-term immobilization of patients. The use of an external fixator i.e. the (1) Delta, (2) Mitkovic or (3) Unilateral frame for treating type III pilon fractures is generally recommended by many experts owing to the stability provided by these constructs. This allows this type of fracture to heal quickly whilst permitting early mobilization. However, the stability of one fixator over the other has not been previously demonstrated. This study was conducted to determine the biomechanical stability of these external fixators in type III pilon fractures using finite element modelling. Three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones were reconstructed from previously obtained CT datasets. Bones were assigned with isotropic material properties, while the cartilage was assigned as hyperelastic springs with Mooney-Rivlin properties. Axial loads of 350 N and 70 N were applied at the tibia to simulate the stance and the swing phase of a gait cycle. To prevent rigid body motion, the calcaneus and metatarsals were fixed distally in all degrees of freedom. The results indicate that the model with the Delta frame produced the lowest relative micromovement (0.03 mm) compared to the Mitkovic (0.05 mm) and Unilateral (0.42 mm) fixators during the stance phase. The highest stress concentrations were found at the pin of the Unilateral external fixator (509.2 MPa) compared to the Mitkovic (286.0 MPa) and the Delta (266.7 MPa) frames. In conclusion, the Delta external fixator was found to be the most stable external fixator for treating type III pilon fractures.
    Matched MeSH terms: External Fixators*
  16. Ramlee MH, Kadir MR, Murali MR, Kamarul T
    Med Eng Phys, 2014 Oct;36(10):1358-66.
    PMID: 25092623 DOI: 10.1016/j.medengphy.2014.07.001
    Subtalar dislocation is a rare injury caused by high-energy trauma. Current treatment strategies include leg casts, internal fixation and external fixation. Among these, external fixators are the most commonly used as this method is believed to provide better stabilization. However, the biomechanical stability provided by these fixators has not been demonstrated. This biomechanical study compares two commonly used external fixators, i.e. Mitkovic and Delta. CT imaging data were used to reconstruct three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones. The 3D models of the bones and cartilages were then converted into four-noded linear tetrahedral elements, whilst the ligaments were modelled with linear spring elements. Bones and cartilage were idealized as homogeneous, isotropic and linear. To simulate loading during walking, axial loading (70 N during the swing and 350 N during the stance phase) was applied at the end of diaphyseal tibia. The results demonstrate that the Mitkovic fixator produced greater displacement (peak 3.0mm and 15.6mm) compared to the Delta fixator (peak 0.8mm and 3.9 mm), in both the swing and stance phase, respectively. This study demonstrates that the Delta external fixator provides superior stability over the Mitkovic fixator. The Delta fixator may be more effective in treating subtalar dislocation.
    Matched MeSH terms: External Fixators*
  17. Phang ZH, Albaker M, Gunalan R, Lee AYX, Saw A
    Singapore Med J, 2024 May 01;65(5):274-278.
    PMID: 34749494 DOI: 10.11622/smedj.2021189
    INTRODUCTION: The aim of this study was to determine whether any change in degree of medial tibia plateau depression after extra-articular mechanical realignment surgery was observed in children with Blount's disease who presented late for treatment in their adolescence and young adulthood.

    METHODS: We retrospectively reviewed the radiographic parameters of 22 patients (32 lower limbs) with Blount's disease who underwent gradual correction of deformity using a ring external fixator without surgical elevation of the depressed medial tibial plateau at a mean age of 15 (range 10-37) years. Preoperative and postoperative angles of depressed medial tibia plateau (ADMTPs) of the same patient were compared for any significant change. Normally distributed data were analysed using Student's t -test when comparing two groups or one-way analysis of variance when comparing more than two groups. Skewed data were analysed using Mann-Whitney test.

    RESULTS: After extra-articular mechanical alignment surgery, statistically significant improvements in medial tibial plateau depression were seen in the infantile ( P = 0.03) and juvenile ( P = 0.04) Blount's subgroups. Change in ADMTP was greater in patients who were operated on at age <17 years, before skeletal maturity ( P = 0.001). The improvement was likely due to ossification of unossified cartilage at the posteromedial proximal tibia and the remodelling potential of proximal tibia physis after mechanical realignment.

    CONCLUSION: Improvement of medial tibia plateau depression is possible after mechanical realignment without surgical hemiplateau elevation in cases of infantile and juvenile Blount's disease that present late for treatment, especially when the operation is performed before 17 years of age.

    Matched MeSH terms: External Fixators
  18. Ong CT, Choon DS, Cabrera NP, Maffulli N
    Injury, 2002 Nov;33(9):829-34.
    PMID: 12379395
    We report the results of external fixation in 29 patients treated for tibial fractures and tibial non-union using a novel multi axial external fixator (MAXX) followed prospectively until bony union. The results of treatment were classified according to the Association for the Study and Application of the Method of Ilizarov (ASAMI). Overall, 13 patients had excellent bone results; 13 had good bone results; two had fair bone results, and 1 patient had poor bone results. Regarding functional results, 21 patients had excellent results; 6 obtained good results; none had fair results, and two had poor results. Acute patients did better functionally than chronic patients. This fixator is safe and versatile, although the indications for its use are very specific.
    Matched MeSH terms: External Fixators*
  19. Norliyana, M., Mohd Yazid, B., Abdul Muhaimin, A.
    Medicine & Health, 2018;13(1):279-285.
    MyJurnal
    Brachymetatarsia is a conditioned which has been described as abnormal short metatarsal bone due to premature closure of the epiphyseal growth plate. It usually involves a single metatarsal bone with the fourth metatarsal being the most common. It may be congenital or acquired. We here report a case in a 53-yearold lady who presented with foot pain and shoe wearing problem. Examination revealed shortening of the bilateral fourth toe and the toes were tilted dorsally. She was diagnosed with bilateral brachymetatarsia and operation was done mainly for cosmetic reasons. Gradual lengthening with distraction osteogenesis was performed using a MiniRail external fixator (Orthofix) and K-wiring of the right fourth metatarsophalangeal joint. Adequate length of fourth metatarsal and good bony union were achieved at the end of treatment.
    Matched MeSH terms: External Fixators
  20. Noia G, Silluzio N, Sircana G, Maccauro G, Ziranu A
    Malays Orthop J, 2019 Nov;13(3):80-84.
    PMID: 31890117 DOI: 10.5704/MOJ.1911.015
    Bilateral fracture-dislocation of the talus is a rare occurrence. It represents 0.06% of the dislocations and 2% of the traumas of the talus. We report the case of a 29-year-old patient with an exposed bilateral fracture of the talus following a plane accident. On the right ankle, the patient had a fracture-dislocation Hawkin 3 Gustilo II, on the left ankle presented a Hawkin 4 Gustilo IIIB. The patient was treated within six hours from the trauma. We reduced the dislocation and performed an osteotomy of the tibial malleolus and osteosynthesis of the fracture with screws. The definitive stabilisation has been achieved in both limbs with an external fixator. We evaluated the patient at 1, 3, 6, 8, 12 and 18 months from treatment, with a radiograph and with SF-36 and Foot and Ankle Disability Index questionnaires. No infection was reported, radiographs showed a successful consolidation of the fracture in both limbs. At the one year follow-up, the patient was able to walk without aids and there were no signs of osteonecrosis on the MRI. The treatment of these lesions requires timely treatment, an anatomical reduction of the fracture and patient's collaboration. The use of external fixator with internal osteosynthesis represents a good therapeutic option in Hawkins 3 and 4 type fractures.
    Matched MeSH terms: External Fixators