Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Wong JHD, Anem LEA, Tan S, Tan SK, Ng KH
    Phys Med, 2019 Dec;68:47-51.
    PMID: 31739145 DOI: 10.1016/j.ejmp.2019.11.007
    OBJECTIVE: This study measured the radiation exposure of the eye lens of medical personnel performing fluoroscopy and interventional procedures at the Sarawak General Hospital in Kuching, Sarawak, Malaysia. This study was the first in Malaysia to utilise in vivo radiation measurement relatively near the eye lens.

    METHODS: 41 medical personnel performing 79 procedures were monitored for their eye lens exposure using the NanoDot™ optically-stimulated luminescence dosimeters (OSLD) taped to the outer canthus of their eyes. The air-kerma area product (KAP), fluoroscopy time (FT) and number of procedure runs were also recorded.

    RESULTS: KAP, FT and number of runs were strongly correlated. However, only weak to moderate correlations were observed between these parameters with the measured eye lens doses. The average median equivalent eye lens dose was 0.052 mSv (ranging from 0.0155 to 0.672 mSv). The eye lens doses of primary operators were found to be significantly higher than their assistants due to the closer proximity to the patient and X-ray tube. The left eye lens of the operators received the highest amount of radiation due to their habitual positioning towards the radiation source.

    CONCLUSION: KAP and FT were not useful in predicting the equivalent eye lens dose exposure in interventional radiological procedures. Direct in vivo measurements were needed to provide a better estimate of the eye lens doses received by medical personnel during these procedures. This study highlights the importance of using direct measurement, such as OSLDs, instead of just indirect factors to monitor dose in the eye lens in radiological procedures.

    Matched MeSH terms: Fluoroscopy/adverse effects
  2. Sun C, Lee WG, Ma Q, Zhang X, Song F, Cai X
    Arch Orthop Trauma Surg, 2024 Apr;144(4):1781-1792.
    PMID: 38147077 DOI: 10.1007/s00402-023-05168-3
    BACKGROUND: Positioning implant components and restoring patient anatomy during total hip arthroplasty (THA) are essential for joint stability, polyethylene liner wear, and range of motion. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during the posterior or posterolateral approach have reported conflicting results. This meta-analysis evaluated if intraoperative fluoroscopy improves component positioning and femoral component position compared to no fluoroscopy during posterior or posterolateral approach total hip arthroplasty.

    METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses standards were followed when conducting the systematic review. We searched Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving Intraoperative fluoroscopy versus no fluoroscopy during posterior or posterolateral approach total hip arthroplasty. Finally, we identified 1133 patients (1145 hips) assessed in seven studies.

    RESULTS: There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.43), ACIA within safe zone rate (P = 0.58), acetabular cup anteversion angle (ACAA, P = 0.46); ACAA within safe zone rate (P = 0.72), Combined safe zone rate (P = 0.28), dislocation rate (P = 0.64) and infection rate (P = 0.94) between two groups. Compared with the no fluoroscopy group, the intraoperative fluoroscopy group had more operation time (P 

    Matched MeSH terms: Fluoroscopy/methods
  3. Sulieman A, Mahgoub O, Salah H, Tamam N, Taha A, Dawood S, et al.
    Appl Radiat Isot, 2023 Dec;202:111071.
    PMID: 37871398 DOI: 10.1016/j.apradiso.2023.111071
    Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.
    Matched MeSH terms: Fluoroscopy/adverse effects; Fluoroscopy/methods
  4. Subhan RA, Puvanan K, Murali MR, Raghavendran HR, Shani S, Abdullah BJ, et al.
    ScientificWorldJournal, 2014;2014:818502.
    PMID: 24983002 DOI: 10.1155/2014/818502
    This study was conducted to develop a technique for minimally invasive and accurate delivery of stem cells to augment nucleus pulposus (NP) in damaged intervertebral discs (IVD). IVD damage was created in noncontiguous discs at L4-L5 level; rabbits (N = 12) were randomly divided into three groups: group I treated with MSCs in HyStem hydrogel, group II treated with HyStem alone, and group III received no intervention. MSCs and hydrogel were administered to the damaged disc under guidance of fluoroscopy. Augmentation of NP was assessed through histological and MRI T2 mapping of the NP after eight weeks of transplantation. T2 weighted signal intensity was higher in group I than in groups II and III (P < 0.05). Disc height index showed maximum disc height in group I compared to groups II and III. Histological score of the degenerative index was significantly (P < 0.05) lower in group I (8.6 ± 1.8) than that in groups II (11.6 ± 2.3) and III (18.0 ± 5.7). Immunohistochemistry staining for collagen type II and aggrecan staining were higher in group I as compared to other groups. Our results demonstrate that the minimally invasive administration of MSCs in hyaluronan hydrogel (HyStem) augments the repair of NP in damaged IVD.
    Matched MeSH terms: Fluoroscopy
  5. Saidatul A, Azlan C, Megat Amin M, Abdullah B, Ng Kh
    Biomed Imaging Interv J, 2010 Jan-Mar;6(1):e1.
    PMID: 21611060 MyJurnal DOI: 10.2349/biij.6.1.e2
    Computed tomography (CT) fluoroscopy is able to give real time images to a physician undertaking minimally invasive procedures such as biopsies, percutaneous drainage, and radio frequency ablation (RFA). Both operators executing the procedure and patients too, are thus at risk of radiation exposure during a CT fluoroscopy.This study focuses on the radiation exposure present during a series of radio frequency ablation (RFA) procedures, and used Gafchromic film (Type XR-QA; International Specialty Products, USA) and thermoluminescent dosimeters (TLD-100H; Bicron, USA) to measure the radiation received by patients undergoing treatment, and also operators subject to scatter radiation.The voltage was held constant at 120 kVp and the current 70mA, with 5mm thickness. The duration of irradiation was between 150-638 seconds.Ultimately, from a sample of 30 liver that have undergone RFA, the study revealed that the operator received the highest dose at the hands, which was followed by the eyes and thyroid, while secondary staff dosage was moderately uniform across all parts of the body that were measured.
    Matched MeSH terms: Fluoroscopy
  6. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Fluoroscopy/methods
  7. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Fluoroscopy/instrumentation; Fluoroscopy/methods
  8. Safari MJ, Wong JHD, Jong WL, Thorpe N, Cutajar D, Rosenfeld A, et al.
    Phys Med, 2017 Mar;35:66-72.
    PMID: 28256398 DOI: 10.1016/j.ejmp.2017.02.002
    PURPOSE: The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures.

    METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.

    RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.

    CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.

    Matched MeSH terms: Fluoroscopy/adverse effects; Fluoroscopy/instrumentation; Fluoroscopy/methods
  9. Radhi AM, Masbah O, Shukur MH, Shahril Y, Taiman K
    Med J Malaysia, 2006 Feb;61 Suppl A:50-2.
    PMID: 17042230
    Orthopaedic procedures especially dynamic hip screw (DHS) fixation, interlocking nailing (ILN) of the tibia and femur require fluoroscopic assistance. Frequent exposure to radiation is a major concern to members of the orthopaedic surgical team. This study was undertaken to measure shallow (skin) dose to the operating team personnel and deep (whole body) dose to the surgeon during such procedures in view to provide guidelines to the operating team members regarding the number of procedures allowable for them to perform or assist annually. Skin dose for the operating personnel and whole body dose for the operating surgeon during 25 procedures; ten cases of DHS, seven and six cases of ILN of the tibia and femur respectively, was measured using Thermoluminescent Dosimeter (TLD) chips. The shallow radiation dose for theatre personnel ranged from 0.19 mSy to 0.61 per case while the deep dose for the surgeon was 0.28, 0.55 and 0.81 mSy for seven cases of tibial ILN, ten cases of DHS and six cases of femur ILN respectively. The surgeon has the highest radiation exposure than other theatre personnel and the whole body exposure for DHS was higher than that of for ILN. However, the estimated cumulative dose was still far below the permissible annual dose limit.
    Matched MeSH terms: Fluoroscopy/adverse effects*
  10. Poh KS, Hoh SY, Aziz R, Chong SS, Roslani AC
    Open Med (Wars), 2020;15:261-265.
    PMID: 32292822 DOI: 10.1515/med-2020-0037
    Ultra-low anterior resection for low rectal cancer is usually done with a covering ileostomy as a safety measure to reduce the consequences of distal anastomotic failure. In many centres, distal loopogram is performed routinely, prior to the closure of the loop ileostomy, to assess the integrity of anastomosis. Distal loopogram is generally considered a safe procedure with very low complication rates, especially when water-soluble contrast is used. We report two cases of delayed bowel perforation which led to severe sepsis and generalized peritonitis after distal loopogram prior to ileostomy closure. Our cases highlight the potential dangers of distal loopogram. Therefore, the routine usage of this procedure should be scrutinized and the patient needs to be properly counselled prior to the procedure.
    Matched MeSH terms: Fluoroscopy
  11. Philip R, Prepageran N, Waran V
    J Laryngol Otol, 2007 Sep;121(9):e14.
    PMID: 17625037
    Sphenoid sinus mucoceles comprise 1-2 per cent of paranasal sinus mucoceles. Endoscopic marsupialisation is currently the treatment of choice.
    Matched MeSH terms: Fluoroscopy
  12. Noh, K.B., Salim, R., Abdullah, M.S., Mohamad, I.
    Malaysian Family Physician, 2018;13(2):36-38.
    MyJurnal
    Foreign body aspiration is commonly described in infants and children. However, recently, a new
    high-risk group was identified among young women, especially those from the Muslim population
    who wear the traditional hair scarf. This is due to the habit of holding the scarf pin in between the
    lips to free hands to adjust the scarf more easily. Talking, laughing, or coughing while fixing the
    scarf may result in inadvertent inhalation of the pin into the tracheobronchial tree. We present a
    case of scarf pin inhalation and the challenges encountered in managing this patient during the
    successful removal of the pin via flexible bronchoscopy under fluoroscopy guidance. This particular
    case was technically challenging for us as the sharp tip of the needle was pointing upward and
    piercing the bronchial mucosa.
    Matched MeSH terms: Fluoroscopy
  13. Noh KB, Salim R, Abdullah MS, Mohamad I
    Malays Fam Physician, 2018;13(2):36-38.
    PMID: 30302183
    Foreign body aspiration is commonly described in infants and children. However, recently, a new high-risk group was identified among young women, especially those from the Muslim population who wear the traditional hair scarf. This is due to the habit of holding the scarf pin in between the lips to free hands to adjust the scarf more easily. Talking, laughing, or coughing while fixing the scarf may result in inadvertent inhalation of the pin into the tracheobronchial tree. We present a case of scarf pin inhalation and the challenges encountered in managing this patient during the successful removal of the pin via flexible bronchoscopy under fluoroscopy guidance. This particular case was technically challenging for us as the sharp tip of the needle was pointing upward and piercing the bronchial mucosa.
    Matched MeSH terms: Fluoroscopy
  14. Muzaffar TST, Imran Y, Iskandar MA, Zakaria A
    Med J Malaysia, 2005 Jul;60 Suppl C:26-9.
    PMID: 16381279
    Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
    Matched MeSH terms: Fluoroscopy*
  15. Mahadeva S, Malik A, Hilmi I, Qua CS, Wong CH, Goh KL
    Nutr Clin Pract, 2008 Apr-May;23(2):176-81.
    PMID: 18390786 DOI: 10.1177/0884533608314535
    Transnasal endoscopic placement of nasoenteric tubes (NETs) has been demonstrated to be useful in the critical care setting, with limited data on its role in non-critically ill patients. The authors collected data on consecutive patients from a non-critical care setting undergoing transnasal endoscopic NET placement. All NETs were endoscopically placed using a standard over-the-guidewire technique, and positions were confirmed with fluoroscopy. Patients were monitored until the removal of NETs or death. Twenty-two patients (median age = 62.5 years, 36.4% female) were referred for postpyloric feeding, with main indications of persistent gastrocutaneous fistula (n = 6), gastroparesis or gastric outlet obstruction (n = 5), duodenal stenosis (n = 6), acute pancreatitis (n = 4), and gastroesophageal reflux after surgery (n = 1). Postpyloric placement of NET was achieved in 19 of 22 (86.3%) patients, with 36.8% tube positions in the jejunum, 47.4% in the distal duodenum, and 15.8% in the second part of the duodenum. NET placement was least successful in cases with duodenal stenosis. NETs remained in situ for a median of 24 days (range, 2-94), with tube dislodgement (n = 3) and clogging (n = 5) as the main complications. NET feeding resulted in complete healing of gastrocutaneous fistulae in 5 of 6 patients and provision of total enteral nutrition in 3 of 4 cases of acute pancreatitis and 9 of 11 cases of gastroparesis or proximal duodenal obstruction. Transnasal endoscopy has a role in the placement of NET in non-critically ill patients requiring postpyloric feeding. However, there are some limitations, particularly in cases with altered duodenal anatomy.
    Matched MeSH terms: Fluoroscopy
  16. Lubis LE, Bayuadi I, Pawiro SA, Ng KH, Bosmans H, Soejoko DS
    Phys Med, 2015 Nov;31(7):659-68.
    PMID: 26050060 DOI: 10.1016/j.ejmp.2015.05.011
    The purpose of this study is to quantify the quality of the available imaging modes for various iodine-based contrast agent concentration in paediatric cardiology. The figure of merit (FOM) was defined as the squared signal to noise ratio divided by a patient dose related parameter. An in house constructed phantom simulated a series of vessel segments with iodine concentrations from 10% or 30 mg/cc to 16% or 48 mg/cc of iodine in a blood plasma solution, all within the dimensional constraints of a paediatric patient. The phantom also used test inserts of tin (Sn). Measurements of Entrance Surface Air Kerma (ESAK) and exit dose rate were performed along with calculations of the signal-to-noise ratio (SNR) of all the objects. A first result showed that it was favourable to employ low dose fluoroscopy mode and lower frame rate modes in cine acquisition if dynamic information is not critical. Normal fluoroscopy dose mode provided a considerably higher dose level (in comparison to low dose mode) with only a slight improvement in SNR. Higher frame rate cine modes should be used however when the clinical situation dictates so. This work also found that tin should not be intended as iodine replacement material for research purposes due to the mismatching SNR, particularly on small vessel sizes.
    Matched MeSH terms: Fluoroscopy
  17. Lim HH, Ong CH
    Med J Malaysia, 2001 Jun;56 Suppl C:41-5.
    PMID: 11814248
    The Pedriolle torsion meter is an established method of vertebral rotation assessment in scoliosis. However, the assessment of scoliosis by this method is static and indirect. The objective of this study is to compare the accuracy of a direct method of assessing scoliosis rotation by fluoroscopy compared to the Pedriolle torsion meter. Secondly, to determine that vertebral body rotation changes with supine posture compared to erect position. Eight volunteers with idiopathic scoliosis were assessed for the apical vertebral rotation with this method and the Pedriolle torsion meter. These patients were also assessed in the supine and erect position with the fluoroscopic method to determine if the apical vertebral rotation would change with posture. The mean Cobb angle of the curves was 62.8 degrees (range 45 degrees to 86 degrees). The mean apical vertebral rotation in a standing position was assessed to be 21.5 degrees by Pedriolle torsion meter and 29 degrees by the fluoroscopic method. This difference was not statistically significant by the student t-test. In most patient, the rotation of vertebrae improved by a varying degree ranging from none to 24 degrees in the supine position. In conclusion, the fluoroscopic method is an alternate mean of measuring vertebrae rotation in idiopathic scoliosis, with comparable accuracy to the Pedriolle torsion meter method. The amount of vertebral rotation changes with posture of the patient.
    Matched MeSH terms: Fluoroscopy
  18. Lee SA, Chiu CK, Chan CYW, Yaakup NA, Wong JHD, Kadir KAA, et al.
    Spine J, 2020 07;20(7):1114-1124.
    PMID: 32272253 DOI: 10.1016/j.spinee.2020.03.015
    BACKGROUND CONTEXT: Biopsy is important to obtain microbiological and histopathological diagnosis in spine infections and tumors. To date, there have been no prospective randomized trials comparing fluoroscopic guided and computed tomography (CT) transpedicular biopsy techniques. The goal of this study was to evaluate the accuracy, safety, and diagnostic outcome of these two diagnostic techniques.

    PURPOSE: To evaluate the accuracy, safety, and diagnostic outcome of fluoroscopic guided and CT transpedicular biopsy techniques.

    STUDY DESIGN: Prospective randomized trial.

    PATIENT SAMPLE: Sixty consecutive patients with clinical symptoms and radiological features suggestive of spinal infection or malignancy were recruited and randomized into fluoroscopic or CT guided spinal biopsy groups. Both groups were similar in terms of patient demographics, distribution of spinal infections and malignancy cases, and the level of biopsies.

    OUTCOME MEASURES: The primary outcome measure was diagnostic accuracy of both methods, determined based on true positive, true negative, false positive, and false negative biopsy findings. Secondary outcome measures included radiation exposure to patients and doctors, complications, and postbiopsy pain score.

    METHODS: A transpedicular approach was performed with an 8G core biopsy needle. Specimens were sent for histopathological and microbiological examinations. Diagnosis was made based on biopsy results, clinical criteria and monitoring of disease progression during a 6-month follow up duration. Clinical criteria included presence of risk factors, level of inflammatory markers and magnetic resonance imaging findings. Radiation exposure to patients and doctors was measured with dosimeters.

    RESULTS: There was no significant difference between the diagnostic accuracy of fluoroscopic and CT guided spinal biopsy (p=0.67) or between the diagnostic accuracy of spinal infection and spinal tumor in both groups (p=0.402 for fluoroscopy group and p=0.223 for CT group). Radiation exposure to patients was approximately 26 times higher in the CT group. Radiation exposure to doctors in the CT group was approximately 2 times higher compared to the fluoroscopic group if a lead shield was not used. Lead shields significantly reduced radiation exposure to doctors anywhere from 2 to 8 times. No complications were observed for either group and the differences in postbiopsy pain scores were not significant.

    CONCLUSIONS: The accuracy, procedure time, complication rate and pain score for both groups were similar. However, radiation exposure to patients and doctors were significantly higher in the CT group without lead protection. With lead protection, radiation to doctors reduced significantly.

    Matched MeSH terms: Fluoroscopy
  19. Lazarescu A, Chan WW, Gyawali CP, Lee YY, Xiao Y, Wu P
    Ann N Y Acad Sci, 2020 12;1481(1):108-116.
    PMID: 32875574 DOI: 10.1111/nyas.14453
    Esophageal dysphagia is a common symptom in adults. Fluoroscopic contrast studies, endoscopy, and esophageal manometry have been used in the diagnosis of esophageal dysphagia for many years. The diagnostic yield has been improved with new test protocols that highlight abnormal bolus transit in the esophagus and outflow obstruction, as well as new high-definition and high-resolution technical advances in equipment. Functional luminal impedance planimetry and the addition of impedance to high-resolution esophageal manometry have also allowed the assessment of new parameters to better understand esophageal structure and function. In this concise review, we describe the role and utility of various diagnostic modalities in the assessment of patients with esophageal dysphagia.
    Matched MeSH terms: Fluoroscopy
  20. Kwi NK, Hing NK
    Med J Malaysia, 1974 Jun;28(4):287-9.
    PMID: 4278824
    Matched MeSH terms: Fluoroscopy/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links