Displaying publications 1 - 20 of 46 in total

Abstract:
Sort:
  1. Yusof AP, Yusoff NH, Suhaimi FW, Coote JH
    Auton Neurosci, 2009 Jun 15;148(1-2):50-4.
    PMID: 19349212 DOI: 10.1016/j.autneu.2009.03.005
    The aim of the present study was to determine if paraventricular-spinal vasopressin neurones participate in the sympatho-inhibitory effects of systemically administered atrial natriuretic peptide (ANP) on renal sympathetic nerve activity (RSNA). Experiments were carried out on male Sprague-Dawley rats anesthetized with 1.3 g/kg urethane. Changes in mean arterial pressure (mm Hg), heart rate (beats per minute) and RSNA (%) were measured following intravenous bolus administration of ANP (250 ng, 500 ng and 5 microg). Intrathecal application of selective V 1a receptor antagonist was performed to test for the involvement of supraspinal vasopressin pathways in mediating the effect on sympathetic outflow evoked by intravenous ANP administration. The results obtained demonstrated that both low and high doses of ANP caused renal sympathoinhibition (250 ng; - 7.5 +/- 1%, 500 ng; - 14.2 +/- 1%, 5 microg; - 16.4 +/- 2%), concomitant with vasodilation and bradycardia. After spinal vasopressin receptor blockade, the inhibitory effects of ANP were prevented and there was a small renal sympatho-excitation (250 ng; + 1.7 +/- 0.2%, 500 ng; + 6.1 +/- 0.03%, 5 microg; + 8.0 +/- 0.03%, P < 0.05). Therefore, the renal sympathetic nerve inhibition elicited by circulating ANP is dependent on the efficacy of a well established supraspinal vasopressin pathway. Since supraspinal vasopressin neurones without exception excite renal sympathetic neurones, it is suggested that ANP elicits this effect by activating cardiac vagal afferents that inhibit the spinally projecting vasopressin neurones at their origin in the paraventricular nucleus of the hypothalamus.
    Matched MeSH terms: Heart Rate/physiology
  2. Wong KI, Ho MM
    PMID: 19162703 DOI: 10.1109/IEMBS.2008.4649200
    Extended patient monitoring has become increasingly important for detection of cardiac conditions, such as irregularities in the rhythms of the heart, while patient is practicing normal daily activity. This paper presents a design of a single lead wireless cardiac rhythm interpretive instrument that capable of capture the electrocardiogram (ECG) in digital format and transmitted to a remote base-station (i.e. PC) for storage and further interpretation. The design has achieved high quality of ECG and free of interference in the presence of motion.
    Matched MeSH terms: Heart Rate/physiology*
  3. Wolkow AP, Rajaratnam SMW, Wilkinson V, Shee D, Baker A, Lillington T, et al.
    Sleep Health, 2020 06;6(3):366-373.
    PMID: 32340910 DOI: 10.1016/j.sleh.2020.03.005
    OBJECTIVES: This study examined the influence of a wrist-worn heart rate drowsiness detection device on heavy vehicle driver safety and sleep and its ability to predict driving events under naturalistic conditions.

    DESIGN: Prospective, non-randomized trial.

    SETTING: Naturalistic driving in Malaysia.

    PARTICIPANTS: Heavy vehicle drivers in Malaysia were assigned to the Device (n = 25) or Control condition (n = 34).

    INTERVENTION: Both conditions were monitored for driving events at work over 4-weeks in Phase 1, and 12-weeks in Phase 2. In Phase 1, the Device condition wore the device operated in the silent mode (i.e., no drowsiness alerts) to examine the accuracy of the device in predicting driving events. In Phase 2, the Device condition wore the device in the active mode to examine if drowsiness alerts from the device influenced the rate of driving events (compared to Phase 1).

    MEASUREMENTS: All participants were monitored for harsh braking and harsh acceleration driving events and self-reported sleep duration and sleepiness daily.

    RESULTS: There was a significant decrease in the rate of harsh braking events (Rate ratio = 0.48, p 

    Matched MeSH terms: Heart Rate/physiology*
  4. Teoh AN, Hilmert C
    Br J Health Psychol, 2018 11;23(4):1040-1065.
    PMID: 30084181 DOI: 10.1111/bjhp.12337
    PURPOSE: The stress-buffering hypothesis (Cohen & McKay, 1984, Handbook of psychology and health IV: Social psychological aspects of health (pp. 253-256). Hillsdale, NJ: Lawrence Erlbaum) suggests that one way social support enhances health is by attenuating cardiovascular reactivity (CVR) to stress. Research that has tested this hypothesis has reported inconsistent findings. In this review, we systematically reviewed those findings and proposed a dual-effect model of social support and CVR as a potential explanation for the inconsistency in the literature. Specifically, we proposed that when participants are more engaged during a stressor, social support acts primarily as social comfort, attenuating CVR; and when participants are not engaged, social support acts primarily as social encouragement, elevating CVR.

    METHODS: We reviewed 22 previous studies that (1) empirically manipulated social support in a stressful situation, (2) measured CVR, and (3) tested a moderator of social support effects on CVR.

    RESULTS: Although a majority of studies reported a CVR-mitigating effect of social support resulting in an overall significant combined p-value, we found that there were different effects of social support on CVR when we considered high- and low-engagement contexts. That is, compared to control conditions, social support lowered CVR in more engaging situations but had no significant effect on CVR in less engaging situations.

    CONCLUSION: Our results suggest that a dual-effect model of social support effects on CVR may better capture the nature of social support, CVR, and health associations than the buffering hypothesis and emphasize a need to better understand the health implications of physiological reactivity in various contexts. Statement of contribution What is already known on this subject? According to the stress-buffering hypothesis (Cohen & McKay, ), one pathway social support benefits health is through mitigating the physiological arousal caused by stress. However, previous studies that examined the effects of social support on blood pressure and heart rate changes were not consistently supporting the hypothesis. Some studies reported that social support causes elevations in cardiovascular reactivity (CVR) to stress (Anthony & O'Brien, ; Hilmert, Christenfeld, & Kulik, ; Hilmert, Kulik, & Christenfeld, ) and others showed no effect of social support on CVR (Christian & Stoney, ; Craig & Deichert, ; Gallo, Smith, & Kircher, ). What does this study add? When participants were in more engaging conditions, social support decreased CVR relative to no support. When participants were in less engaging conditions, social support did not have a significant effect on CVR. Provide an alternative way to explain the ways social support affects cardiac health.

    Matched MeSH terms: Heart Rate/physiology*
  5. Tan CY, Shahrizaila N, Yeoh KY, Goh KJ, Tan MP
    Clin Auton Res, 2019 06;29(3):339-348.
    PMID: 29654380 DOI: 10.1007/s10286-018-0525-z
    OBJECTIVE: The current study aimed to investigate autonomic dysfunction in Guillain-Barré syndrome (GBS) patients and describe the results of computational heart rate variability (HRV)/baroreflex sensitivity (BRS) and autonomic challenge tests.

    METHODS: GBS patients were consecutively recruited and the results were compared to age- and gender-matched healthy controls. A series of autonomic function tests including computation-dependent tests (power spectrum analysis of HRV and BRS at rest) and challenge maneuvers (deep breathing, eyeball compression, active standing, the Valsalva maneuver, sustained handgrip, and the cold pressor test) were performed.

    RESULTS: Ten GBS patients (six men; mean age = 40.1 ± 13.9 years) and ten gender- and age-matched healthy controls were recruited. The mean GBS functional grading scale at disease plateau was 3.4 ± 1.0. No patients required intensive care unit admission or mechanical ventilation. Low-frequency HRV (p = 0.027), high-frequency HRV (p = 0.008), and the total power spectral density of HRV (p = 0.015) were significantly reduced in patients compared to controls. The mean up slope (p = 0.034), down slope (p = 0.011), and total slope (p = 0.024) BRS were significantly lower in GBS patients. The diastolic rise in blood pressure in the cold pressor test was significantly lower in GBS patients compared to controls (p = 0.008).

    INTERPRETATION: Computation-dependent tests (HRV and BRS) were more useful for detecting autonomic dysfunction in GBS patients, whereas the cold pressor test was the only reliable challenge test, making it useful as a bedside measure of autonomic function in GBS patients.

    Matched MeSH terms: Heart Rate/physiology*
  6. Sharifah Maimunah SM, Hashim HA
    Percept Mot Skills, 2016 Feb;122(1):227-37.
    PMID: 27420318 DOI: 10.1177/0031512515625383
    This study compares two versions of progressive muscle relaxation (PMR) training (7 and 16 muscle groups) on oxygen consumption (VO2), heart rates, rating of perceived exertion and choice reaction time. Football (soccer) players (N = 26; M age = 13.4 yr., SD = 0.5) were randomly assigned to either 7 muscle groups PMR, 16 muscle groups PMR, or a control group. PMR training requires the participants to tense a muscle, hold the muscle contraction, and then relax it. Measurement was conducted prior to and after the completion of 12 sessions of PMR. The dependent variables were measured following four bouts of intermittent exercise consisting of 12 min. of running at 60% VO2max for 10 min. followed by running at 90% VO2max for 2 min. with a 3-min. rest for each bout. Lower VO2, heart rate, perceived exertion, and quicker reaction time were expected in both relaxation groups compared to the control group. The results revealed a significant reduction in heart rates and choice reaction time for both relaxation groups, but the longer version produced significantly quicker choice reaction time.
    Matched MeSH terms: Heart Rate/physiology*
  7. Shariat A, Cleland JA, Danaee M, Alizadeh R, Sangelaji B, Kargarfard M, et al.
    Work, 2018;60(4):549-554.
    PMID: 30103362 DOI: 10.3233/WOR-182762
    BACKGROUND: There are many potential training exercises for office workers in an attempt to prevent musculoskeletal disorders. However, to date a suitable tool to monitor the perceived exertion of those exercises does not exist.

    OBJECTIVE: The primary objective of this study was to examine the validity and reliability of the Borg CR-10 scale to monitor the perceived exertion of office exercise training.

    METHODS: The study involved 105 staff members employed in a government office with an age range from 25 to 50 years. The Borg CR-10 scale was self-administered two times, with an interval of two weeks in order to evaluate the accuracy of the original findings with a retest. Face validity and content validity were also examined.

    RESULTS: Reliability was found to be high for the Borg CR-10 scale (0.898). Additionally a high correlation between the Borg CR-10 scale and Visual Analog Scale (VAS) was identified (rs = 0.754, P 

    Matched MeSH terms: Heart Rate/physiology
  8. Sahayadhas A, Sundaraj K, Murugappan M
    Australas Phys Eng Sci Med, 2013 Jun;36(2):243-50.
    PMID: 23719977 DOI: 10.1007/s13246-013-0200-6
    Driver drowsiness has been one of the major causes of road accidents that lead to severe trauma, such as physical injury, death, and economic loss, which highlights the need to develop a system that can alert drivers of their drowsy state prior to accidents. Researchers have therefore attempted to develop systems that can determine driver drowsiness using the following four measures: (1) subjective ratings from drivers, (2) vehicle-based measures, (3) behavioral measures and (4) physiological measures. In this study, we analyzed the various factors that contribute towards drowsiness. A total of 15 male subjects were asked to drive for 2 h at three different times of the day (00:00-02:00, 03:00-05:00 and 15:00-17:00 h) when the circadian rhythm is low. The less intrusive physiological signal measurements, ECG and EMG, are analyzed during this driving task. Statistically significant differences in the features of ECG and sEMG signals were observed between the alert and drowsy states of the drivers during different times of day. In the future, these physiological measures can be fused with vision-based measures for the development of an efficient drowsiness detection system.
    Matched MeSH terms: Heart Rate/physiology*
  9. Rajendra Acharya U, Faust O, Adib Kadri N, Suri JS, Yu W
    Comput Biol Med, 2013 Oct;43(10):1523-9.
    PMID: 24034744 DOI: 10.1016/j.compbiomed.2013.05.024
    Diabetes mellitus (DM) affects considerable number of people in the world and the number of cases is increasing every year. Due to a strong link to the genetic basis of the disease, it is extremely difficult to cure. However, it can be controlled to prevent severe consequences, such as organ damage. Therefore, diabetes diagnosis and monitoring of its treatment is very important. In this paper, we have proposed a non-invasive diagnosis support system for DM. The system determines whether or not diabetes is present by determining the cardiac health of a patient using heart rate variability (HRV) analysis. This analysis was based on nine nonlinear features namely: Approximate Entropy (ApEn), largest Lyapunov exponet (LLE), detrended fluctuation analysis (DFA) and recurrence quantification analysis (RQA). Clinically significant measures were used as input to classification algorithms, namely AdaBoost, decision tree (DT), fuzzy Sugeno classifier (FSC), k-nearest neighbor algorithm (k-NN), probabilistic neural network (PNN) and support vector machine (SVM). Ten-fold stratified cross-validation was used to select the best classifier. AdaBoost, with least squares (LS) as weak learner, performed better than the other classifiers, yielding an average accuracy of 90%, sensitivity of 92.5% and specificity of 88.7%.
    Matched MeSH terms: Heart Rate/physiology*
  10. Puthiaparampil T
    Med J Malaysia, 2020 07;75(4):406-408.
    PMID: 32724004
    Collapsing pulse is generally elicited by elevating the patient's arm. However, the pulse becoming stronger on arm elevation is a physiological phenomenon, which is bound to create confusion, if routine lifting of the arm in search of collapsing pulse is practiced. The name 'collapsing pulse' represents only the second component of this sign. It masks the more important first component - the slapping, bounding upstroke, characterised by its other name 'water-hammer pulse'. It is possible to elicit this sign by appreciating the slapping character on routine pulse examination. The insistence on arm lifting in medical school teaching is better avoided.
    Matched MeSH terms: Heart Rate/physiology*
  11. Poznanski RR, Cacha LA, Al-Wesabi YMS, Ali J, Bahadoran M, Yupapin PP, et al.
    Sci Rep, 2017 May 31;7(1):2746.
    PMID: 28566682 DOI: 10.1038/s41598-017-01849-3
    A model of solitonic conduction in neuronal branchlets with microstructure is presented. The application of cable theory to neurons with microstructure results in a nonlinear cable equation that is solved using a direct method to obtain analytical approximations of traveling wave solutions. It is shown that a linear superposition of two oppositely directed traveling waves demonstrate solitonic interaction: colliding waves can penetrate through each other, and continue fully intact as the exact pulses that entered the collision. These findings indicate that microstructure when polarized can sustain solitary waves that propagate at a constant velocity without attenuation or distortion in the absence of synaptic transmission. Solitonic conduction in a neuronal branchlet arising from polarizability of its microstructure is a novel signaling mode of electrotonic signals in thin processes (<0.5 μm diameter).
    Matched MeSH terms: Heart Rate/physiology
  12. Palaniappan R, Phon-Amnuaisuk S, Eswaran C
    Int J Cardiol, 2015;190:262-3.
    PMID: 25932800 DOI: 10.1016/j.ijcard.2015.04.175
    Matched MeSH terms: Heart Rate/physiology*
  13. Ooi JH, Lim R, Seng H, Tan MP, Goh CH, Lovell NH, et al.
    Biomed Eng Online, 2024 Feb 20;23(1):23.
    PMID: 38378540 DOI: 10.1186/s12938-024-01202-6
    PURPOSE: Non-invasive, beat-to-beat variations in physiological indices provide an opportunity for more accessible assessment of autonomic dysfunction. The potential association between the changes in these parameters and arterial stiffness in hypertension remains poorly understood. This systematic review aims to investigate the association between non-invasive indicators of autonomic function based on beat-to-beat cardiovascular signals with arterial stiffness in individuals with hypertension.

    METHODS: Four electronic databases were searched from inception to June 2022. Studies that investigated non-invasive parameters of arterial stiffness and autonomic function using beat-to-beat cardiovascular signals over a period of > 5min were included. Study quality was assessed using the STROBE criteria. Two authors screened the titles, abstracts, and full texts independently.

    RESULTS: Nineteen studies met the inclusion criteria. A comprehensive overview of experimental design for assessing autonomic function in terms of baroreflex sensitivity and beat-to-beat cardiovascular variabilities, as well as arterial stiffness, was presented. Alterations in non-invasive indicators of autonomic function, which included baroreflex sensitivity, beat-to-beat cardiovascular variabilities and hemodynamic changes in response to autonomic challenges, as well as arterial stiffness, were identified in individuals with hypertension. A mixed result was found in terms of the association between non-invasive quantitative autonomic indices and arterial stiffness in hypertensive individuals. Nine out of 12 studies which quantified baroreflex sensitivity revealed a significant association with arterial stiffness parameters. Three studies estimated beat-to-beat heart rate variability and only one study reported a significant relationship with arterial stiffness indices. Three out of five studies which studied beat-to-beat blood pressure variability showed a significant association with arterial structural changes. One study revealed that hemodynamic changes in response to autonomic challenges were significantly correlated with arterial stiffness parameters.

    CONCLUSIONS: The current review demonstrated alteration in autonomic function, which encompasses both the sympathetic and parasympathetic modulation of sinus node function and vasomotor tone (derived from beat-to-beat cardiovascular signals) in hypertension, and a significant association between some of these parameters with arterial stiffness. By employing non-invasive measurements to monitor changes in autonomic function and arterial remodeling in individuals with hypertension, we would be able to enhance our ability to identify individuals at high risk of cardiovascular disease. Understanding the intricate relationships among these cardiovascular variability measures and arterial stiffness could contribute toward better individualized treatment for hypertension in the future.

    SYSTEMATIC REVIEW REGISTRATION: PROSPERO ID: CRD42022336703. Date of registration: 12/06/2022.

    Matched MeSH terms: Heart Rate/physiology
  14. Ooi CH, Ng SK, Omar EA
    Appl Physiol Nutr Metab, 2020 May;45(5):513-519.
    PMID: 31675478 DOI: 10.1139/apnm-2019-0553
    There is emerging evidence that hydrogen-rich water (H2-water) has beneficial effects on the physiological responses to exercise. However, few studies investigate its ergogenic potential. This randomized controlled trial examined the effects of H2-water ingestion on physiological responses and exercise performance during incremental treadmill running. In a double-blind crossover design, 14 endurance-trained male runners (age, 34 ± 4 years; body mass, 63.1 ± 7.2 kg; height, 1.72 ± 0.05 m) were randomly assigned to ingest 2 doses of 290-mL H2-water or placebo on each occasion. The first bolus was given before six 4-min submaximal running bouts, and the second bolus was consumed before the maximal incremental running test. Expired gas, heart rate (HR), and ratings of perceived exertion (RPE) were recorded; blood samples were collected at the end of each submaximal stage and post maximal running test. Cardiorespiratory responses, RPE, and blood gas indices were not significantly different at each submaximal running intensity (range: 34%-91% maximal oxygen uptake) between H2-water and placebo trials. No statistical difference was observed in running time to exhaustion (618 ± 126 vs. 619 ± 113 s), maximal oxygen uptake (56.9 ± 4.4 vs. 57.1 ± 4.7 mL·kg-1·min-1), maximal HR (184 ± 7 vs. 184 ± 7 beat·min-1), and RPE (19 ± 1 vs. 19 ± 1) in the runners between the trials. The results suggest that the ingestion of 290 mL of H2-water before submaximal treadmill running and an additional dose before the subsequent incremental running to exhaustion were not sufficiently ergogenic in endurance-trained athletes. Novelty Acute ingestion of H2-water does not seem to be ergogenic for endurance performance. A small dose of H2-water does not modulate buffering capacity during intense endurance exercise in athletes.
    Matched MeSH terms: Heart Rate/physiology
  15. Müller AM, Wang NX, Yao J, Tan CS, Low ICC, Lim N, et al.
    JMIR Mhealth Uhealth, 2019 10 02;7(10):e14120.
    PMID: 31579026 DOI: 10.2196/14120
    BACKGROUND: Wrist-worn activity trackers are popular, and an increasing number of these devices are equipped with heart rate (HR) measurement capabilities. However, the validity of HR data obtained from such trackers has not been thoroughly assessed outside the laboratory setting.

    OBJECTIVE: This study aimed to investigate the validity of HR measures of a high-cost consumer-based tracker (Polar A370) and a low-cost tracker (Tempo HR) in the laboratory and free-living settings.

    METHODS: Participants underwent a laboratory-based cycling protocol while wearing the two trackers and the chest-strapped Polar H10, which acted as criterion. Participants also wore the devices throughout the waking hours of the following day during which they were required to conduct at least one 10-min bout of moderate-to-vigorous physical activity (MVPA) to ensure variability in the HR signal. We extracted 10-second values from all devices and time-matched HR data from the trackers with those from the Polar H10. We calculated intraclass correlation coefficients (ICCs), mean absolute errors, and mean absolute percentage errors (MAPEs) between the criterion and the trackers. We constructed decile plots that compared HR data from Tempo HR and Polar A370 with criterion measures across intensity deciles. We investigated how many HR data points within the MVPA zone (≥64% of maximum HR) were detected by the trackers.

    RESULTS: Of the 57 people screened, 55 joined the study (mean age 30.5 [SD 9.8] years). Tempo HR showed moderate agreement and large errors (laboratory: ICC 0.51 and MAPE 13.00%; free-living: ICC 0.71 and MAPE 10.20%). Polar A370 showed moderate-to-strong agreement and small errors (laboratory: ICC 0.73 and MAPE 6.40%; free-living: ICC 0.83 and MAPE 7.10%). Decile plots indicated increasing differences between Tempo HR and the criterion as HRs increased. Such trend was less pronounced when considering the Polar A370 HR data. Tempo HR identified 62.13% (1872/3013) and 54.27% (5717/10,535) of all MVPA time points in the laboratory phase and free-living phase, respectively. Polar A370 detected 81.09% (2273/2803) and 83.55% (9323/11,158) of all MVPA time points in the laboratory phase and free-living phase, respectively.

    CONCLUSIONS: HR data from the examined wrist-worn trackers were reasonably accurate in both the settings, with the Polar A370 showing stronger agreement with the Polar H10 and smaller errors. Inaccuracies increased with increasing HRs; this was pronounced for Tempo HR.

    Matched MeSH terms: Heart Rate/physiology*
  16. Mohamed NG, Abidin NZ, Law KS, Abe M, Suzuki M, Muhamed AM, et al.
    J Physiol Anthropol, 2014;33:28.
    PMID: 25189184 DOI: 10.1186/1880-6805-33-28
    Menstruation is associated with significant unpleasantness, and wearing a sanitary napkin (SN) during menses causes discomfort. In addition, many Muslim women use a thick type of SN during menses due to the religious requirement that even disposable SNs be washed before disposal. Therefore, the objective of this study was to measure the physiological and psychological responses to wearing SNs of different thicknesses during menstruation and non-menstruation phases at rest and during physical activity/exercise among Muslim women.
    Matched MeSH terms: Heart Rate/physiology*
  17. Md Lazin Md Lazim MR, Aminuddin A, Chellappan K, Ugusman A, Hamid AA, Wan Ahmad WAN, et al.
    PMID: 32290168 DOI: 10.3390/ijerph17072591
    Finger photoplethysmography (PPG) waveform is blood volume change of finger microcirculation that reflects vascular function. Reflection index (RI), stiffness index (SI) and second derivative of photoplethysmogram (SDPPG) are derived from PPG waveforms proposed as cardiovascular disease (CVD) markers. Heart rate (HR) is a known factor that affects vascular function. Individual resting HR variation may affect RI, SI and SDPPG. This review aims to identify studies about the relationship between HR with RI, SI and SDPPG among humans. A literature search was conducted in Medline via the Ebscohost and Scopus databases to find relevant articles published within 11 years. The main inclusion criteria were articles in the English language that discuss the relationship between HR with RI, SI and SDPPG using PPG among humans. The search found 1960 relevant articles but only six articles that met the inclusion criteria. SI and RI showed an association with HR. SDPPG (SDPPG-b/SDPPG-a ratio, SDPPG-d/SDPPG-a ratio, aging index (AGI) and revised aging index (RAGI)) also had an association with HR. Only RI had a considerable association with HR, the association between SI and HR was non-considerable and the association between HR and SDPPG was inconclusive. Further interventional studies should be conducted to investigate this issue, as a variation in resting HR may challenge the validity of PPG-based CVD markers.
    Matched MeSH terms: Heart Rate/physiology*
  18. Malik AA, Williams CA, Weston KL, Barker AR
    J Sports Sci Med, 2019 03;18(1):1-12.
    PMID: 30787646
    High-intensity interval exercise (HIIE) may not elicit prominent unpleasant feelings even with elevated perceived exertion and physiological stress in adolescents. However, the influence of different HIIE work intensities on the affective experience and cardiorespiratory responses is unknown. This study examined the acute affective, enjoyment, perceived exertion and cardiorespiratory responses to HIIE with different work intensities in adolescents. Participants (n = 16; 8 boys; age 12.0 ± 0.3 years) performed, on separate days, HIIE conditions consisting of 8 x 1-minute work-intervals at 70%, 85%, or 100% peak power separated by 75 seconds recovery at 20 W. Affect, enjoyment and rating of perceived exertion (RPE) were recorded before, during, and after HIIE. Heart rate (HR) and oxygen uptake were collected during HIIE. Affect declined in all conditions (p < 0.01) but 100%HIIE elicited significantly lower affect than 70%HIIE and 85%HIIE at work-interval 8 (all p < 0.02, ES > 1.74; 70%HIIE = 2.5 ± 0.8; 85%HIIE = 1.1 ± 1.5; 100%HIIE = -1.5 ± 1.4 on feeling scale). Similar enjoyment was evident during and after all conditions (all p > 0.44). RPE was significantly higher during 100%HIIE than 70%HIIE and 85%HIIE across all work-intervals (all p < 0.01, ES > 1.56). The majority of the participants attained ≥90%HRmax during 85%HIIE (87%) and 100%HIIE (100%), but not during 70%HIIE (6%). Affect responses during HIIE are dependent on the intensity of the work-interval and are not entirely negative (unpleasant feelings). Despite similar enjoyment, positive affect experienced during 70%HIIE and 85%HIIE could serve as a strategy to encourage exercise adoption and adherence in adolescents, but only 85%HIIE elicits sufficient HR stimulus to facilitate potential health benefits.
    Matched MeSH terms: Heart Rate/physiology
  19. Malarvili MB, Mesbah M
    IEEE Trans Biomed Eng, 2009 Nov;56(11):2594-603.
    PMID: 19628449 DOI: 10.1109/TBME.2009.2026908
    In this paper, we investigate the use of heart rate variability (HRV) for automatic newborn seizure detection. The proposed method consists of a sequence of processing steps, namely, obtaining HRV from the ECG, extracting a discriminating HRV feature set, selecting an optimal subset from the full feature set, and, finally, classifying the HRV into seizure/nonseizure using a supervised statistical classifier. Due to the fact that HRV signals are nonstationary, a set of time-frequency features from the newborn HRV is proposed and extracted. In order to achieve efficient HRV-based automatic newborn seizure detection, a two-phase wrapper-based feature selection technique is used to select the feature subset with minimum redundancy and maximum class discriminability. Tested on ECG recordings obtained from eight newborns with identified EEG seizure, the proposed HRV-based neonatal seizure detection algorithm achieved 85.7% sensitivity and 84.6% specificity. These results suggest that the HRV is sensitive to changes in the cardioregulatory system induced by the seizure, and therefore, can be used as a basis for an automatic seizure detection.
    Matched MeSH terms: Heart Rate/physiology*
  20. Mahadi KM, Lall VK, Deuchars SA, Deuchars J
    Brain Stimul, 2019 05 06;12(5):1151-1158.
    PMID: 31129152 DOI: 10.1016/j.brs.2019.05.002
    BACKGROUND: Electrical stimulation on select areas of the external auricular dermatome influences the autonomic nervous system. It has been postulated that activation of the Auricular Branch of the Vagus Nerve (ABVN) mediates such autonomic changes. However, the underlying neural pathways mediating these effects are unknown and, further, our understanding of the anatomical distribution of the ABVN in the auricle has now been questioned.

    OBJECTIVE: To investigate the effects of electrical stimulation of the tragus on autonomic outputs in the rat and probe the underlying neural pathways.

    METHODS: Central neuronal projections from nerves innervating the external auricle were investigated by injections of the transganglionic tracer cholera toxin B chain (CTB) into the right tragus of Wistar rats. Physiological recordings of heart rate, perfusion pressure, respiratory rate and sympathetic nerve activity were made in an anaesthetic free Working Heart Brainstem Preparation (WHBP) of the rat and changes in response to electrical stimulation of the tragus analysed.

    RESULTS: Neuronal tracing from the tragus revealed that the densest CTB labelling was within laminae III-IV of the dorsal horn of the upper cervical spinal cord, ipsilateral to the injection sites. In the medulla oblongata, CTB labelled afferents were observed in the paratrigeminal nucleus, spinal trigeminal tract and cuneate nucleus. Surprisingly, only sparse labelling was observed in the vagal afferent termination site, the nucleus tractus solitarius. Recordings made from rats at night time revealed more robust sympathetic activity in comparison to day time rats, thus subsequent experiments were conducted in rats at night time. Electrical stimulation was delivered across the tragus for 5 min. Direct recording from the sympathetic chain revealed a central sympathoinhibition by up to 36% following tragus stimulation. Sympathoinhibition remained following sectioning of the cervical vagus nerve ipsilateral to the stimulation site, but was attenuated by sectioning of the upper cervical afferent nerve roots.

    CONCLUSIONS: Inhibition of the sympathetic nervous system activity upon electrical stimulation of the tragus in the rat is mediated at least in part through sensory afferent projections to the upper cervical spinal cord. This challenges the notion that tragal stimulation is mediated by the auricular branch of the vagus nerve and suggests that alternative mechanisms may be involved.

    Matched MeSH terms: Heart Rate/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links