Displaying all 17 publications

Abstract:
Sort:
  1. Chiu CL, Wang CY
    Anaesth Intensive Care, 2004 Feb;32(1):77-80.
    PMID: 15058125
    This is a preliminary report on the use of the modified Airway Management Device in 50 spontaneously breathing patients undergoing elective day care surgery. We were successful in establishing a clear airway in all 50 patients, 46 of these patients had a patient airway on the first attempt. All patients were successfully managed with the Airway Management Device throughout the surgery. Partial airway obstruction during maintenance of anaesthesia occurred in three cases requiring only minor manipulations. Our result showed that the Airway Management Device may be used as an alternative airway management in anaesthesia.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  2. Ng CC, Sybil Shah MHB, Chaw SH, Mansor MB, Tan WK, Koong JK, et al.
    Expert Rev Med Devices, 2021 Feb;18(2):203-210.
    PMID: 33322949 DOI: 10.1080/17434440.2021.1865796
    Background: Supraglottic airway devices have increasingly been used as the airway technique of choice in laparoscopic surgeries. This study compared the efficacy and safety of the Baska Mask with endotracheal tube (ETT) in patients undergoing elective laparoscopic cholecystectomy.Research design and methods: This single-center, prospective, randomized controlled trial recruited 60 patients aged 18-75 years with American Society of Anesthesiologists' classifications I to III. The time taken to achieve effective airway, number of attempts, ease of insertion, ventilation parameters, hemodynamics data, and pharyngolaryngeal complications were recorded.Results: The time taken to achieve effective airway was shorter for the Baska group (26.6 ± 4.7 vs. 47.2 ± 11.8 s; p
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  3. Wong TE, Lim LH, Tan WJ, Khoo TH
    Burns, 2010 Aug;36(5):e78-81.
    PMID: 20036061 DOI: 10.1016/j.burns.2009.10.016
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  4. Shashinder S, Tang IP, Kuljit S, Muthu K, Gopala KG, Jalaludin MA
    Med J Malaysia, 2008 Aug;63(3):254-5.
    PMID: 19248703 MyJurnal
    A synthetic tracheostomy tube [non-metallic type] fracturing within three days of insertion is very rare but it could lead to serious complications such as acute asphyxia or sudden death. We report three such cases at our centre. Recommendations are made to closely observe patients on tracheostomy tube in the first seven days post-insertion of the tube.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  5. Shariffuddin II, Wang CY
    Anaesthesia, 2008 Jan;63(1):82-5.
    PMID: 18086075
    We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  6. Noor Zairul M, Khairul Faizi A, Norzalina E
    Med J Malaysia, 2006 Jun;61(2):157-61.
    PMID: 16898305
    The purpose of this study is to assess whether the newly developed laryngeal tube (LT) VBM is easy, simple to use and able to provide adequate ventilation and oxygenation to a patient with an unstable neck who required airway management. We compared the LT to the laryngeal mask airway (LMA) as alternative airway management tool in adult patient with unstable neck who underwent intubation with manual in-line neck stabilization. A randomized single-blinded prospective study was conducted involving a total of 40 ASA I and II premedicated patients who were divided into two groups with 20 patients for each group; either LT or LMA group for airway management during elective surgery. After preoxygenation, anaesthesia was induced and neuromuscular blockade was produced with intravenous drugs. The LT or LMA was inserted after neuromuscular blockade was confirmed using a peripheral nerve stimulator (TOF 1). A size 3, 4 or 5 LT OR a size 3 or 4 LMA was inserted while the patient's head and neck were being stabilized by an assistant who held the sides of the neck and the mastoid processes (manual in-line stabilization). If it was not possible to ventilate the lungs, or if endotrachial carbon dioxide (ETCO2) and/or chest movement did not indicate a patent airway, the LT or LMA was removed. After three failed attempts, the study was terminated and the airway was secured in the most suitable manner determined by the anaesthetist. There was a statistically significant difference for both groups in the time required for successful insertion (time required for LT was 24.8 +/- 7.7 seconds and LMA was 36.1+/-17.3 seconds) (p= 0.01). There was no statistical differences (p>0.05) in number of attempts needed to achieve a patent airway although we were able to achieve a clear airway in all patients in LT group at the first attempt compared with 85% in LMA group. successful insertion rate was 100% for both groups. We conclude that the LT is easier to insert and is a suitable alternative to the LMA for airway management when the patient's head and neck are stabilized by manual in-line method.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  7. Rahimah AN, Shahfi FI, Masaany M, Gazali N, Siti SH
    J Laryngol Otol, 2016 Oct;130(10):967-968.
    PMID: 27774924
    Laryngotracheal stenosis is a complex condition of airway compromise involving either the larynx or trachea, or both.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  8. Tsan SEH, Lim SM, Abidin MFZ, Ganesh S, Wang CY
    Anesth Analg, 2020 07;131(1):210-219.
    PMID: 31348051 DOI: 10.1213/ANE.0000000000004349
    BACKGROUND: Approximately half of all difficult tracheal intubations (DTIs) are unanticipated; hence, proper positioning during intubation is critical to increase the likelihood of success. The bed-up-head-elevated (BUHE) intubation position has been shown to improve laryngeal view, reduce airway complications, and prolong safe apneic time during intubation. In this study, we sought to determine whether the BUHE intubation position is noninferior to Glidescope (GLSC)-assisted intubation with regard to laryngeal exposure.

    METHODS: A total of 138 American Society of Anesthesiologists (ASA) I to III patients were randomly assigned into 2 groups and underwent baseline laryngoscopy in the sniffing position. Group BUHE patients (n = 69) were then intubated in the BUHE position, while group GLSC patients (n = 69) were intubated using GLSC laryngoscopy. Laryngeal exposure was measured using Percentage of Glottic Opening (POGO) score and Cormack-Lehane (CL) grading, and noninferiority will be declared if the difference in mean POGO scores between both groups do not exceed -15% at the lower limit of a 98% confidence interval (CI). Secondary outcomes measured included time required for intubation (TRI), number of intubation attempts, use of airway adjuncts, effort during laryngoscopy, and complications during intubation.

    RESULTS: Mean POGO score in group BUHE was 80.14% ± 22.03%, while in group GLSC it was 86.45% ± 18.83%, with a mean difference of -6.3% (98% CI, -13.2% to 0.6%). In both groups, there was a significant improvement in mean POGO scores when compared to baseline laryngoscopy in the sniffing position (group BUHE, 25.8% ± 4.7%; group GLSC, 30.7% ± 6.8%) (P < .0001). The mean TRI was 36.23 ± 14.41 seconds in group BUHE, while group GLSC had a mean TRI of 44.33 ± 11.53 seconds (P < .0001). In patients with baseline CL 3 grading, there was no significant difference between mean POGO scores in both groups (group BUHE, 49.2% ± 19.6% versus group GLSC, 70.5% ± 29.7%; P = .054).

    CONCLUSIONS: In the general population, BUHE intubation position provides a noninferior laryngeal view to GLSC intubation. The laryngeal views obtained in both approaches were superior to the laryngeal view obtained in the sniffing position. In view of the many advantages of the BUHE position for intubation, the lack of proven adverse effects, the simplicity, and the cost-effectiveness, we propose that clinicians should consider the BUHE position as the standard intubation position for the general population.

    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  9. Kumar Sinasamy T, Nazaruddin Wan Hassan WM, Hardy Mohamad Zaini R, Seevaunnamtum P, Ab Mukmin L
    Anaesthesiol Intensive Ther, 2020;52(5):383-388.
    PMID: 33327696 DOI: 10.5114/ait.2020.101407
    INTRODUCTION: The Baska mask and i-gel are two new types of second-generation supraglottic airway devices. The aim of this study was to compare these two devices in terms of quality of insertion, quality of ventilation and post-insertion complications.

    MATERIAL AND METHODS: A total of 80 adult patients who were scheduled for elective surgery under general anaesthesia were randomised to two groups: Group BM: Baska mask (n = 40) and Group IG: i-gel (n = 40). The assessment focused on ease of insertion, number of attempts, insertion time, number of corrective manoeuvres, oropharyngeal leak pressure, tidal volume, peak airway pressure (PAP) and post-insertion complications.

    RESULTS: Group IG showed a significantly shorter median insertion time (13.3 [interquartile range, IQR 7.8] vs. 17.0 [IQR 9.6] s; P < 0.001), a higher percentage in the 'very easy' ease of insertion category (62.5% vs. 10.0%; P < 0.001), a higher percentage in the no corrective manoeuvre category (92.5% vs. 72.5%; P = 0.003) and a higher percentage in the no post-operative throat pain category (67.5% vs. 32.5%; P = 0.011) than Group BM. However, Group BM showed a significantly higher generated PAP than Group IG (12.7 [1.8] and 11.5 [2.2] cm H2O, respectively; P = 0.010). There were no significant differences in other parameters.

    CONCLUSIONS: The i-gel was better than the Baska mask in terms of ease of insertion, speed of insertion, fewer corrective manoeuvres and less post-operative throat pain. However, the Baska mask had a better cuff seal, as shown by a higher generated PAP.

    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  10. Narhari R, Nazaruddin Wan Hassan WM, Mohamad Zaini RH, Che Omar S, Abdullah Nik Mohamad N, Seevaunnamtum P
    Anaesthesiol Intensive Ther, 2020;52(5):377-382.
    PMID: 33327695 DOI: 10.5114/ait.2020.101387
    INTRODUCTION: The choice of endotracheal tube (ETT) is important for successful orotracheal fibreoptic intubation (OFI). The aim of this study was to compare the use of the Parker flex tip (PFT) with the unoflex reinforced (UFR) ETT during OFI.

    MATERIAL AND METHODS: A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.

    RESULTS: he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.

    CONCLUSIONS: The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.

    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  11. Noor Azhar M, Bustam A, Poh K, Ahmad Zahedi AZ, Mohd Nazri MZA, Azizah Ariffin MA, et al.
    Emerg Med J, 2021 Feb;38(2):111-117.
    PMID: 33219133 DOI: 10.1136/emermed-2020-210514
    BACKGROUND: Concerns over high transmission risk of SARS-CoV-2 have led to innovation and usage of an aerosol box to protect healthcare workers during airway intubation in patients with COVID-19. Its efficacy as a barrier protection in addition to the use of a standard personal protective equipment (PPE) is not fully known. We performed a simulated study to investigate the relationship between aerosol box usage during intubation and contaminations on healthcare workers pre-doffing and post-doffing of PPE.

    METHODS: This was a randomised cross-over study conducted between 9 April to 5 May 2020 in the ED of University Malaya Medical Centre. Postgraduate Emergency Medicine trainees performed video laryngoscope-assisted intubation on an airway manikin with and without an aerosol box in a random order. Contamination was simulated by nebulised Glo Germ. Primary outcome was number of contaminated front and back body regions pre-doffing and post-doffing of PPE of the intubator and assistant. Secondary outcomes were intubation time, Cormack-Lehane score, number of intubation attempts and participants' feedback.

    RESULTS: Thirty-six trainees completed the study interventions. The number of contaminated front and back body regions pre-doffing of PPE was significantly higher without the aerosol box (all p values<0.001). However, there was no significant difference in the number of contaminations post-doffing of PPE between using and not using the aerosol box, with a median contamination of zero. Intubation time was longer with the aerosol box (42.5 s vs 35.5 s, p<0.001). Cormack-Lehane scores were similar with and without the aerosol box. First-pass intubation success rate was 94.4% and 100% with and without the aerosol box, respectively. More participants reported reduced mobility and visibility when intubating with the aerosol box.

    CONCLUSIONS: An aerosol box may significantly reduce exposure to contaminations but with increased intubation time and reduced operator's mobility and visibility. Furthermore, the difference in degree of contamination between using and not using an aerosol box could be offset by proper doffing of PPE.

    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  12. Shariffuddin II, Chaw SH, Ng LW, Lim CH, Zainal Abidin MF, Wan Zakaria WA, et al.
    BMC Anesthesiol, 2020 07 31;20(1):184.
    PMID: 32736516 DOI: 10.1186/s12871-020-01100-z
    BACKGROUND: The 4th National Audit Project of The Royal College of Anaesthetists and The Difficult Airway Society (NAP4) reported a higher incidence of supraglottic airway device (SAD) related pulmonary aspiration in obese patients especially with the first-generation SADs. The latest single-use SAD, the Protector™ provides a functional separation of the respiratory and digestive tracts and its laryngeal cuff with two ports allowing additional suction in tandem with the insertion of a gastric tube. The laryngeal cuff of LMA Protector™ allows a large catchment reservoir in the event of gastric content aspiration.

    METHODS: We evaluated the performance characteristics of the LMA Protector™ in 30 unparalysed, moderately obese patients. First attempt insertion rate, time for insertion, oropharyngeal leak pressure (OLP), and incidence of complications were recorded.

    RESULTS: We found high first and second attempt insertion rates of 28(93%) and 1(33%) respectively, with one failed attempt where no capnography trace could be detected, presumably from a downfolded device tip. The LMA Protector™ was inserted rapidly in 21.0(4.0) seconds and demonstrated high OLP of 31.8(5.4) cmH2O. Fibreoptic assessment showed a clear view of vocal cords in 93%. The incidence of blood staining on removal of device was 48%, postoperative sore throat 27%, dysphagia 10% and dysphonia 20% (all self-limiting, resolving a few hours postoperatively).

    CONCLUSIONS: We conclude that the LMA Protector™ was associated with easy, expedient first attempt insertion success, demonstrating high oropharyngeal pressures and good anatomical position in the moderately obese population, with relatively low postoperative airway morbidity.

    TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12617001152314 . Registered 7 August 2017.

    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  13. Lim D, Parumo R, Ma CB, Palasuntharam S
    J Clin Anesth, 2017 09;41:97-98.
    PMID: 28802621 DOI: 10.1016/j.jclinane.2017.07.001
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  14. Noor Zairul M, Khairul Faizi A
    Singapore Med J, 2006 Oct;47(10):892-6.
    PMID: 16990966
    INTRODUCTION: The purpose of this study is to assess whether the newly-developed VBM (Medizintechnik GmbH, Sulz, Germany) laryngeal tube (LT) is able to provide adequate ventilation and oxygenation to patients with an unstable neck and require airway management. The haemodynamic responses to insertion between the two devices were also studied. We compared the LT to the laryngeal mask airway (LMA) as an alternative airway management tool in adult patients with unstable neck and who underwent intubation with manual in-line neck stabilisation.
    METHODS: A randomised single-blinded prospective study was conducted involving a total of 40 American Society of Anesthesiology I and II pre-medicated patients who were divided into two groups, LT or LMA, for airway management during elective surgery. There were 20 patients for each group. After pre-oxygenation, anaesthesia was induced using intravenous (i.v.) fentanyl and i.v. propofol. The neuromuscular blockade was produced with either i.v. vecuronium or i.v. atracurium. The LT or LMA was inserted after neuromuscular blockade was confirmed using a peripheral nerve stimulator (train-of-four 1). A size 3, 4 or 5 LT or a size 3 or 4 LMA was inserted while the patient's head and neck were being stabilised by an assistant who held the sides of the neck and the mastoid processes (manual in-line stabilisation). If it was not possible to ventilate the lungs, or if end-tidal carbon dioxide and/or chest movement did not indicate a patent airway, the LT or LMA was removed. After three failed attempts, the study was terminated and the airway was secured in the most suitable manner determined by the anaesthetist. After successful placement of LT or LMA, anaesthesia was maintained with 66 percent nitrous oxide in oxygen and 2 minimum alveolar concentration sevoflurane. All patients received standard anaesthesia monitoring. The ease of insertion, the number of attempts needed to successfully secure the airway, episodes of desaturation (less than 95 percent) and end-tidal carbon dioxide at various time intervals were studied. The haemodynamic parameters such as systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate at different time intervals were also studied.
    RESULTS: The study showed a statistically significant difference in time required for successful insertion between the groups; time required for LT was 24.8 +/- 7.7 seconds and LMA was 36.1 +/- 17.3 seconds (p-value equals 0.01). Both groups had no statistical differences (p-value is greater than 0.05) in number of attempts needed to achieve a patent airway, and the successful insertion rate was 100 percent for both groups. There were also no statistical differences in the haemodynamic response to insertion and the end-tidal carbon dioxide in this study.
    CONCLUSION: We conclude that, under anaesthesia, the LT was a valuable and better alternative to LMA for ventilation and airway management when the patient's head and neck are stabilised by the manual in-line method.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation*
  15. Wong AK, Teoh GS
    Anaesth Intensive Care, 1996 Apr;24(2):224-30.
    PMID: 9133197
    The quality of laryngoscopy and tracheal intubation with propofol augmented by alfentanil was investigated as an alternative technique for rapid tracheal intubation. 119 patients aged between 18 and 60 years (ASA 1 and 2) undergoing elective surgery were prospectively studied in a randomized double-blind controlled fashion. Tracheal intubation facilitated by suxamethonium 1.0 mg/kg alfentanil 15 mu g/kg alfentanil 30 mu g/kg or saline control was compared after propofol induction. The quality of laryngoscopy and intubation were graded according to jaw relaxation, ease of insertion of the endotracheal tube and coughing on intubation. Failure to intubate occurred in 4% and 17% with alfentanil 15 mu g/kg and saline control respectively Tracheal intubation was successful in all patients with alfentanil 30 mu g/kg and suxamethonium 1.0 mg/kg. Alfentanil 15 mu g/kg was not statistically significantly different from saline (P = 0.112). Alfentanil 30 mu g/kg provided similar overall intubating conditions (P = 0.5) to suxamethonium 1.0 mg/kg. Alfentanil in both dosages effectively attenuated the haemodynamic responses to laryngoscopy and tracheal intubation.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  16. Mohd Esa NY, Faisal M, Vengadesa Pilla S, Abdul Rahaman JA
    BMJ Case Rep, 2020 Dec 22;13(12).
    PMID: 33370965 DOI: 10.1136/bcr-2020-236414
    Tracheal tear after endotracheal intubation is extremely rare. The role of silicone Y-stent in the management of tracheal injury has been documented in the previous studies. However, none of the studies have mentioned the deployment of silicone Y-stent via rigid bronchoscope with the patient solely supported by extracorporeal membrane oxygenation (ECMO) without general anaesthesia delivered via the side port of the rigid bronchoscope. We report a patient who had a tracheal tear due to endotracheal tube migration following a routine video-assisted thoracoscopic surgery sympathectomy, which was successfully managed with silicone Y-stent insertion. Procedure was done while she was undergoing ECMO; hence, no ventilator connection to the side port of the rigid scope was required. This was our first experience in performing Y-stent insertion fully under ECMO, and the patient had a successful recovery.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
  17. Lew YS
    Singapore Med J, 2000 Aug;41(8):398-400.
    PMID: 11256348
    One lung anaesthesia in paediatric patients may not always be achievable by bronchial blockade or double lumen tube intubation due to inadequate experiences or facilities. We attempted to isolate right lung by selectively intubating the left bronchus with single lumen tube on a 10 kg child. Optimal surgical condition and satisfactory oxygenation achieved but complicated with severe respiratory acidosis. The possible causes for hypercapnea in this child were discussed.
    Matched MeSH terms: Intubation, Intratracheal/instrumentation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links