Displaying publications 1 - 20 of 63 in total

Abstract:
Sort:
  1. Kiong TC, Nordin N, Ahmad Ruslan NAA, Kan SY, Ismail NM, Zakaria Z, et al.
    Environ Res, 2022 Oct;213:113737.
    PMID: 35752328 DOI: 10.1016/j.envres.2022.113737
    To keep COVID-19 at bay, most countries have mandated the use of face masks in public places and imposed heavy penalties for those who fail to do so. This has inadvertently created a huge demand for disposable face masks and worsened the problem of littering, where a large number of used masks are constantly discarded into the environment. As such, an efficient and innovative waste management strategy for the discarded face mask is urgently needed. This study presents the transformation of discarded face mask into catalyst termed 'mask waste ash catalyst (MWAC)' to synthesise bisindolylmethanes (BIMs), alkaloids that possess antibacterial, antioxidant and antiviral properties. Using commercially available aldehydes and indole, an excellent yield of reaction (62-94%) was achieved using the MWAC in the presence of water as the sole solvent. On the other hand, the FT-IR spectrum of MWAC showed the absorption bands at 2337 cm-1, 1415 cm-1 and 871 cm-1, which correspond to the signals of calcium oxide. It is then proposed that the calcium oxides mainly present in MWAC can protonate oxygen atoms in the carbonyl molecule of the aldehyde group, thus facilitating the nucleophile attack by indole which consequently improved the product yield. Moreover, the MWAC is also observed to facilitate the photodegradation of methylene blue with an efficiency of up to 94.55%. Our results showed the potential applications of the MWAC derived from discarded face masks as a sustainable catalyst for bioactive compound synthesis and photodegradation of dye compounds.
    Matched MeSH terms: Masks
  2. Tham LY, Beh ZY, Shariffuddin II, Wang CY
    Korean J Anesthesiol, 2019 12;72(6):606-609.
    PMID: 31304693 DOI: 10.4097/kja.d.18.00354
    BACKGROUND: The laryngeal mask airway (LMAⓇ) ProtectorTM (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff PilotTM technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.

    CASE: We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.

    CONCLUSIONS: This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff PilotTM technology is not a panacea for potential cranial nerve injury after airway manipulation.

    Matched MeSH terms: Laryngeal Masks/adverse effects*
  3. Chiu CL, Murugasu J, Chan L
    Anaesth Intensive Care, 2003 Apr;31(2):187-92.
    PMID: 12712784
    We have compared the use of the laryngeal mask airway with the new modified laryngeal tube in a prospective randomized controlled study. Sixty ASA 1 or 2 patients, aged 18 to 65 years, scheduled for elective surgery and breathing spontaneously under general anaesthesia, were studied. After preoxygenation, anaesthesia was induced with fentanyl and propofol. The patients were randomized to receive either a laryngeal mask airway or a laryngeal tube. Anaesthesia was maintained with nitrous oxide, oxygen and isoflurane. We recorded the speed and the ease of insertion, the number of attempts needed to successfully secure the airway and intraoperative complications, such as partial airway obstruction needing airway manipulation. The airway devices were removed with the patients fully awake at the end of surgery. Systolic arterial blood pressure, heart rate and end-tidal CO2 were recorded at various time intervals. Postoperative complications were recorded. We found that the incidence of partial airway obstruction needing intraoperative airway manipulation was higher with the laryngeal tube than with the laryngeal mask airway. We conclude that during spontaneous ventilation the modified laryngeal tube is not as reliable in providing a satisfactory airway and we consider it is not a suitable alternative to the laryngeal mask airway.
    Matched MeSH terms: Laryngeal Masks*
  4. Estudillo AJ, Wong HK
    PLoS One, 2024;19(1):e0295407.
    PMID: 38166082 DOI: 10.1371/journal.pone.0295407
    Although it is generally accepted that face recognition relies on holistic processing, it has been suggested that the simultaneous face matching task may depend on a more analytical or featural processing approach. However, empirical evidence supporting this claim is limited. In two experiments, we further explored the role of holistic and featural processing on simultaneous face matching by manipulating holistic processing through inversion and presenting faces with or without face masks. The results from Experiment 1 revealed that both inversion and face masks impaired matching performance. However, while the inversion effect was evident in both full-view and masked faces, the mask effect was only found in upright, but not inverted, faces. These results were replicated in Experiment 2 but, the inversion and mask effects were stronger in delayed face matching than in simultaneous face matching. Our findings suggest that simultaneous face matching relies on holistic processing, but to a smaller extent compared to higher memory-demanding identification tasks.
    Matched MeSH terms: Masks*
  5. Koh HP, Shamsudin NS, Tan MMY, Mohd Pauzi Z
    J Clin Pharm Ther, 2021 Aug;46(4):1129-1138.
    PMID: 33768601 DOI: 10.1111/jcpt.13410
    WHAT IS KNOWN AND OBJECTIVE: Nebulizer use has been suspended in Malaysian public health facilities due to the potential to aggravate COVID-19 nosocomial transmission. Currently, our facility uses the pressurized metered-dose inhaler (pMDI) bronchodilator with Venturi mask modified spacer (VMMS) in patients visiting the Emergency Department (ED) for mild to moderate exacerbation of asthma and chronic obstructive pulmonary disease (COPD). We sought to assess the outcomes and acceptance of pMDI-VMMS in the outpatient ED of a tertiary hospital in Malaysia.

    METHODS: We analysed the total visits and discharge rates during periods of using the nebulizer and current pMDI-VMMS methods. The acceptance of pMDI-VMMS by patients and assistant medical officers (AMOs) were assessed by questionnaire.

    RESULTS AND DISCUSSION: We analysed 3184 ED visits and responses from 103 patients and 32 AMOs. The direct discharge rate was similar for both nebulizer (n = 2162, 92.5%) and pMDI-VMMS method (n = 768, 90.7%) (p-value = 0.120). Twenty-eight patients (27.2%) favoured the pMDI-VMMS over the nebulizer, whereas 36 patients (35.0%) had no preference for either method. Sixty-four patients (62.1%) felt that the current pMDI-VMMS method was better or at least as effective in relieving their symptoms as a nebulizer. The current method was favoured over the nebulizer by twenty-seven AMOs (84.4%). Twenty-eight (87.5%) AMOs suggested that the current method was more effective than the nebulizer.

    WHAT IS NEW AND CONCLUSION: The bronchodilator delivered via pMDI-VMMS appeared to be comparable to nebulizer in treating mild to moderate asthma and COPD exacerbations in the outpatient ED. Most patients and AMOs accepted the use of pMDI-VMMS in the outpatient ED during the current COVID-19 pandemic. The Venturi mask modified spacer can be a cheap and effective alternative to the commercial spacer in a resource-limited situation.

    Matched MeSH terms: Masks
  6. Teoh CY, Lim FS
    Paediatr Anaesth, 2008 Feb;18(2):119-24.
    PMID: 18184242 DOI: 10.1111/j.1460-9592.2007.02385.x
    The Proseal laryngeal mask airway (PLMA) is a relatively new supraglottic airway device with a drain tube to minimize the risk of gastric insufflation and aspiration. We compared introducer tool (IT) and gum elastic bougie (GEB)-guided techniques for insertion of the Proseal LMA in children.
    Matched MeSH terms: Laryngeal Masks/adverse effects*
  7. Dharmaraj S, Ashokkumar V, Hariharan S, Manibharathi A, Show PL, Chong CT, et al.
    Chemosphere, 2021 Jun;272:129601.
    PMID: 33497928 DOI: 10.1016/j.chemosphere.2021.129601
    Recently, the COVID-19 disease spread has emerged as a worldwide pandemic and cause severe threats to humanity. The World Health Organisation (WHO) releases guidelines to help the countries to reduce the spread of this virus to the public, like wearing masks, hand hygiene, social distancing, shutting down all types of public transports, etc. These conditions led to a worldwide economic fall drastically, and on the other hand, indirect environmental benefits like global air quality improvement and decreased water pollution are also pictured. Currently, use of face masks is part of a comprehensive package of the prevention and control measures that can limit the spread of COVID-19 since there is no clinically proven drugs or vaccine available for COVID-19. Mostly, face masks are made of petroleum-based non-renewable polymers that are non-biodegradable, hazardous to the environment and create health issues. This study demonstrates the extensive use of the face mask and how it affects human health and the marine ecosystem. It has become a great challenge for the government sectors to impose strict regulations for the proper disposal of the masks as medical waste by the public. Neglecting the seriousness of this issue may lead to the release of large tonnes of micro-plastics to the landfill as well as to the marine environment where mostly end-up and thereby affecting their fauna and flora population vastly. Besides, this study highlights the COVID-19 spread, its evolutionary importance, taxonomy, genomic structure, transmission to humans, prevention, and treatment.
    Matched MeSH terms: Masks
  8. Hui MT, Subash S, Wang CY
    Anaesthesia, 2011 Apr;66(4):274-7.
    PMID: 21401540 DOI: 10.1111/j.1365-2044.2011.06620.x
    The 50% and 95% effective doses of desflurane for removal of the classic laryngeal mask airway after suction of the upper airway, in anaesthetised spontaneously breathing adult patients, are not known. To determine these, we studied 38 healthy patients, aged between 18 and 44 years. The target desflurane concentration in each individual patient was determined by the Dixon up-and-down method. When the predetermined target end-tidal desflurane concentration reached steady state, we kept a constant end-expiratory partial pressure between the alveolus and the brain for 10 min before attempting to remove the classic laryngeal mask airway after suctioning the upper airway. The initial desflurane target concentration was set at 6% and up-down desflurane increments were 0.1%. This continued until there were at least six crossover pairs. From the probit analysis, the 50% effective dose of desflurane was 5.29% (95% CI 5.132-5.379%) and the 95% effective dose was 5.55% (95% CI 5.429-6.394%).
    Matched MeSH terms: Laryngeal Masks*
  9. Goh PK, Chiu CL, Wang CY, Chan YK, Loo PL
    Anaesth Intensive Care, 2005 Apr;33(2):223-8.
    PMID: 15960405
    The aim of this prospective, double-blind, randomized, placebo-controlled clinical trial was to investigate whether the administration of ketamine before induction with propofol improves its associated haemodynamic profile and laryngeal mask airway (LMA) insertion conditions. Ninety adult patients were randomly allocated to receive either ketamine 0.5 mg x kg(-1) (n = 30), fentanyl 1 microg x kg(-1) (n = 30) or normal saline (n = 30), before induction of anaesthesia with propofol 2.5 mg x kg(-1). Insertion of the LMA was performed 60s after injection of propofol. Arterial blood pressure and heart rate were measured before induction (baseline), immediately after induction, immediately before LMA insertion, immediately after LMA insertion and every minute for three minutes after LMA insertion. Following LMA insertion, the following six subjective endpoints were graded by a blinded anaesthestist using ordinal scales graded 1 to 3: mouth opening, gagging, swallowing, movement, laryngospasm and ease of insertion. Systolic blood pressure was significantly higher following ketamine than either fentanyl (P = 0.010) or saline (P = 0.0001). The median (interquartile range) summed score describing the overall insertion conditions were similar in the ketamine [median 7.0, interquartile range (6.0-8.0)] and fentanyl groups [median 7.0, interquartile range (6.0-8.0)]. Both appeared significantly better than the saline group [median 8.0, interquartile range (6.75-9.25); P = 0.024]. The incidence of prolonged apnoea (> 120s) was higher in the fentanyl group [23.1% (7/30)] compared with the ketamine [6.3% (2/30)] and saline groups [3.3% (1/30)]. We conclude that the addition of ketamine 0.5 mg x kg(-1) improves haemodynamics when compared to fentanyl 1 microg x kg(-1), with less prolonged apnoea, and is associated with better LMA insertion conditions than placebo (saline).
    Matched MeSH terms: Laryngeal Masks*
  10. Adi O, Via G, Salleh SH, Chuan TW, Rahman JA, Muhammad NAN, et al.
    Am J Emerg Med, 2021 Nov;49:385-392.
    PMID: 34271286 DOI: 10.1016/j.ajem.2021.06.031
    STUDY OBJECTIVE: To determine whether non-invasive ventilation (NIV) delivered by helmet continuous positive airway pressure (hCPAP) is non-inferior to facemask continuous positive airway pressure (fCPAP) in patients with acute respiratory failure in the emergency department (ED).

    METHODS: Non-inferiority randomized, clinical trial involving patients presenting with acute respiratory failure conducted in the ED of a local hospital. Participants were randomly allocated to receive either hCPAP or fCPAP as per the trial protocol. The primary endpoint was respiratory rate reduction. Secondary endpoints included discomfort, improvement in Dyspnea and Likert scales, heart rate reduction, arterial blood oxygenation, partial pressure of carbon dioxide (PaCO2), dryness of mucosa and intubation rate.

    RESULTS: 224 patients were included and randomized (113 patients to hCPAP, 111 to fCPAP). Both techniques reduced respiratory rate (hCPAP: from 33.56 ± 3.07 to 25.43 ± 3.11 bpm and fCPAP: from 33.46 ± 3.35 to 27.01 ± 3.19 bpm), heart rate (hCPAP: from 114.76 ± 15.5 to 96.17 ± 16.50 bpm and fCPAP: from 115.07 ± 14.13 to 101.19 ± 16.92 bpm), and improved dyspnea measured by both the Visual Analogue Scale (hCPAP: from 16.36 ± 12.13 to 83.72 ± 12.91 and fCPAP: from 16.01 ± 11.76 to 76.62 ± 13.91) and the Likert scale. Both CPAP techniques improved arterial oxygenation (PaO2 from 67.72 ± 8.06 mmHg to 166.38 ± 30.17 mmHg in hCPAP and 68.99 ± 7.68 mmHg to 184.49 ± 36.38 mmHg in fCPAP) and the PaO2:FiO2 (Partial pressure of arterial oxygen: Fraction of inspired oxygen) ratio from 113.6 ± 13.4 to 273.4 ± 49.5 in hCPAP and 115.0 ± 12.9 to 307.7 ± 60.9 in fCPAP. The intubation rate was lower with hCPAP (4.4% for hCPAP versus 18% for fCPAP, absolute difference -13.6%, p = 0.003). Discomfort and dryness of mucosa were also lower with hCPAP.

    CONCLUSION: In patients presenting to the ED with acute cardiogenic pulmonary edema or decompensated COPD, hCPAP was non-inferior to fCPAP and resulted in greater comfort levels and lower intubation rate.

    Matched MeSH terms: Masks/standards*; Masks/statistics & numerical data
  11. Shariffuddin II, Wang CY
    Anaesthesia, 2008 Jan;63(1):82-5.
    PMID: 18086075
    We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.
    Matched MeSH terms: Laryngeal Masks*
  12. Chew EE, Hashim NH, Wang CY
    Anaesth Intensive Care, 2010 Nov;38(6):1018-22.
    PMID: 21226431
    We compared the performance of the LMA Supreme (SLMA) with the I-Gel during anaesthesia in spontaneously breathing adult patients. Ninety patients with American Society of Anesthesiologists physical status I or II were studied in a prospective randomised controlled study. Our primary outcome measure was oropharyngeal leak pressure. We also compared the overall insertion success rate, ease of insertion, adequacy of ventilation and incidence of complications. The mean (SD), oropharyngeal leak pressure for the SLMA was 25.6 (5.1) cmH2O, which was greater than for the I-Gel 20.7 (5.9) cmH2O (P = 0.0001). The first attempt and overall insertion success rates were similar between the two groups (SLMA 97.8 and 97.8%; I-Gel 93.3 and 100%, P = 0.132). The SLMA was rated easier to insert than the I-Gel (P = 0.011), but the time taken for insertion (P = 0.433) was similar. The incidence of complications was low in both groups. The grade of fibreoptic view was better with the I-Gel than the SLMA (P = 0.001). We conclude that in adults with normal airways, the SLMA is easier to insert and provides a higher oropharyngeal leak pressure, but fibreoptic views are better with the i-gel.
    Matched MeSH terms: Laryngeal Masks*
  13. Payus AO, Rajah R, Febriany DC, Mustafa N
    Open Access Maced J Med Sci, 2019 Feb 15;7(3):396-399.
    PMID: 30834009 DOI: 10.3889/oamjms.2019.114
    BACKGROUND: De novo pulmonary embolism (DNPE) is a term used when pulmonary embolism (PE) occur in the absence of deep vein thrombosis (DVT). Most DNPE cases occur in a patient who had a recent injury to the chest.

    CASE PRESENTATION: However, here we report a case of DNPE with a slightly different presentation where there is no preceding trauma and has symptoms that mimic severe pneumonia. He presented with high fever, dyspnoea and pleuritic chest pain. Despite on 10 L of oxygen supplementation via high flow mask and already given bolus intravenous antibiotic, the patient still tachypnoeic and was persistently in type I respiratory failure. His chest X-ray showed consolidative changes. Upon further investigation revealed no evidence of DVT on Doppler ultrasound and normal D-dimer level. Due to the high index of suspicion by the attending physician, PE was suspected and later confirmed with computed tomography pulmonary angiography scan. He was successfully treated with anticoagulation therapy. The objective of this case report is to share the difficult experience of diagnosing PE when the presentation highly atypical and mimics severe pneumonia.

    CONCLUSION: And with such a masquerading presentation, one can easily miss the diagnosis. To the best of our knowledge, there are very few similar cases reported.

    Matched MeSH terms: Masks
  14. Chowdhury MA, Shuvho MBA, Shahid MA, Haque AKMM, Kashem MA, Lam SS, et al.
    Environ Res, 2021 Jan;192:110294.
    PMID: 33022215 DOI: 10.1016/j.envres.2020.110294
    The rapid spread of COVID-19 has led to nationwide lockdowns in many countries. The COVID-19 pandemic has played serious havoc on economic activities throughout the world. Researchers are immensely curious about how to give the best protection to people before a vaccine becomes available. The coronavirus spreads principally through saliva droplets. Thus, it would be a great opportunity if the virus spread could be controlled at an early stage. The face mask can limit virus spread from both inside and outside the mask. This is the first study that has endeavoured to explore the design and fabrication of an antiviral face mask using licorice root extract, which has antimicrobial properties due to glycyrrhetinic acid (GA) and glycyrrhizin (GL). An electrospinning process was utilized to fabricate nanofibrous membrane and virus deactivation mechanisms discussed. The nanofiber mask material was characterized by SEM and airflow rate testing. SEM results indicated that the nanofibers from electrospinning are about 15-30 μm in diameter with random porosity and orientation which have the potential to capture and kill the virus. Theoretical estimation signifies that an 85 L/min rate of airflow through the face mask is possible which ensures good breathability over an extensive range of pressure drops and pore sizes. Finally, it can be concluded that licorice root membrane may be used to produce a biobased face mask to control COVID-19 spread.
    Matched MeSH terms: Masks
  15. Tang SGH, Hadi MHH, Arsad SR, Ker PJ, Ramanathan S, Afandi NAM, et al.
    Int J Environ Res Public Health, 2022 Oct 11;19(20).
    PMID: 36293576 DOI: 10.3390/ijerph192012997
    Since the year 2020, coronavirus disease 2019 (COVID-19) has emerged as the dominant topic of discussion in the public and research domains. Intensive research has been carried out on several aspects of COVID-19, including vaccines, its transmission mechanism, detection of COVID-19 infection, and its infection rate and factors. The awareness of the public related to the COVID-19 infection factors enables the public to adhere to the standard operating procedures, while a full elucidation on the correlation of different factors to the infection rate facilitates effective measures to minimize the risk of COVID-19 infection by policy makers and enforcers. Hence, this paper aims to provide a comprehensive and analytical review of different factors affecting the COVID-19 infection rate. Furthermore, this review analyses factors which directly and indirectly affect the COVID-19 infection risk, such as physical distance, ventilation, face masks, meteorological factor, socioeconomic factor, vaccination, host factor, SARS-CoV-2 variants, and the availability of COVID-19 testing. Critical analysis was performed for the different factors by providing quantitative and qualitative studies. Lastly, the challenges of correlating each infection risk factor to the predicted risk of COVID-19 infection are discussed, and recommendations for further research works and interventions are outlined.
    Matched MeSH terms: Masks
  16. Mokhtar AM, Choy CY
    Middle East J Anaesthesiol, 2013 Feb;22(1):65-70.
    PMID: 23833853
    Postoperative sore throat after minor pediatric surgery although uncommon and the symptoms are mild, the incidence may be affected by several factors. This study was designed to compare the frequency and severity of post operative sore throat in children undergoing elective surgery following the use of proseal LMA (PLMA) compared to classic LMA (cLMA).
    Matched MeSH terms: Laryngeal Masks/adverse effects*
  17. Fu, Tzeh Long, Ong, Kien Chai, Wong, Kum Thong
    Neurology Asia, 2015;20(4):349-354.
    MyJurnal
    We have developed and characterised a mouse model of Japanese encephalitis virus (JEV) infection via
    footpad inoculation in order to better mimic viral transmission by mosquito bites. Two-week-old and
    5-week-old mice consistently developed signs of infection such as ruffled fur, weight loss, hunchback
    posture, tremors, mask-like facies and occasionally, hindlimb paralysis at 4 days post infection (dpi)
    and 11-13 dpi, respectively. Most of the animals died within 24 to 48 hours following the onset of signs
    of infection, with mortalities of 100% and 33.3% in 2-week-old and 5-week-old mice, respectively.
    Mild meningitis and variable parenchymal inflammation with formation of microglial nodules, focal
    necrosis and neuronophagia, and perivascular cuffing by inflammatory cells were observed in the
    caudate nucleus, putamen, thalamus, cerebral cortex, brainstem, and spinal cord. Viral antigens/RNA
    were demonstrated by immunohistochemisty and in situ hybridization, respectively, in most of these
    areas as well as in the hippocampus and cerebellum, albeit more focally. The pathological findings in
    this mouse model were generally similar to human Japanese encephalitis (JE) and other established JE
    models but perhaps, compared to other JEV mouse models, it demonstrates lethal encephalitic infection
    more consistently. We believe that our mouse model should be useful to study the pathogenesis of JE,
    and for testing anti-viral drugs and vaccines
    Matched MeSH terms: Masks
  18. Saad-Ilyas M, Zehra U, Khan UU, Mohammad I, Muhammad R, Aziz A
    Malays Orthop J, 2021 Mar;15(1):72-78.
    PMID: 33880151 DOI: 10.5704/MOJ.2103.011
    Introduction: The study aimed to target the current practices of the orthopaedic community in outpatient (OPD), emergency (ER) and surgical services (OT) during COVID-19.

    Material and method: This study surveyed 303 orthopaedic surgeons from all over Pakistan. The survey had 30 questions targeting the setup of outpatient, emergency and operation services in orthopaedic departments of different hospitals in Pakistan.

    Result: A total of 302 surgeons were included from 53 cities all over Pakistan. Between 35-48% of the respondents reported lack of availability of standard operating procedures in OPD, ER and in OT. Majority of the respondents noted that their OPD and surgical practice had been affected to some degree and 69% of the surgeons were only doing trauma surgery. This trend was higher in younger consultants of less than 45 years of age (p<0.001). Almost two-third of the surgeons, mostly senior (p=0.03) were using surgical masks as the only protective measure during various practices of OPD, ER and OT, while most of the setups were not assessing patients even for signs and symptoms of COVID. Almost 89% of the orthopaedic community is facing definite to mild stress during this pandemic and this has significantly affected the senior surgeons (p=0.01).

    Conclusion: Our study highlighted that COVID-19 has resulted in marked changes to the practices of the majority of Pakistani orthopaedic surgeons. Despite a sharp upsurge in the number of cases and mortality due to COVID-19, guidelines were still lacking at most of the settings and a substantial percentage of the orthopaedic community were not following adequate safety measures while attending to patients.

    Matched MeSH terms: Masks
  19. Cheah PK, Ahmed R, Ho CV, Lim CC
    Malays Fam Physician, 2009;4(2-3):91-3.
    PMID: 25606171 MyJurnal
    Nasal foreign body in children is not an uncommon presentation to the Emergency Department. Removal is essential. Many methods of removal exist. Nasal wash technique is advocated mainly in friable foreign bodies. We report the successful use of the oral bag-valve-mask insufflation technique to remove friable facial tissue in the left nose of a 2 year-old girl. We used a pediatric bag-valve-mask with a pop-off pressure relief valve to avoid barotrauma. Pop-off pressure relief valve limits the pressure beyond 30mmHg. Conscious sedation was not required. There were no complications.
    Matched MeSH terms: Masks
  20. Rao AS, Yew AEG, Inbasegaran K
    Med J Malaysia, 2003 Dec;58(5):717-22.
    PMID: 15190658 MyJurnal
    The summary of various studies done looking at size selection of the laryngeal mask airway (LMA) in adults is that, selection based on sex is appropriate, and that both sizes 4 or 5 are adequate for adult females. However, in our local population these sizes may be too large especially the size 5 for adult females.
    Matched MeSH terms: Laryngeal Masks/standards*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links