Displaying publications 1 - 20 of 36 in total

Abstract:
Sort:
  1. Moniruzzaman M, Rodríguez I, Ramil M, Cela R, Sulaiman SA, Gan SH
    Talanta, 2014 Nov;129:505-15.
    PMID: 25127626 DOI: 10.1016/j.talanta.2014.06.019
    The performance of gas chromatography (GC) combined with a hybrid quadrupole time-of-flight (QTOF) mass spectrometry (MS) system for the determination of volatile and semi-volatile compounds in honey samples is evaluated. After headspace (HS) solid-phase microextraction (SPME) of samples, the accurate mass capabilities of the above system were evaluated for compounds identification. Accurate scan electron impact (EI) MS spectra allowed discriminating compounds displaying the same nominal masses, but having different empirical formulae. Moreover, the use of a mass window with a width of 0.005 Da provided highly specific chromatograms for selected ions, avoiding the contribution of interferences to their peak areas. Additional information derived from positive chemical ionization (PCI) MS spectra and ion product scan MS/MS spectra permitted confirming the identity of novel compounds. The above possibilities are illustrated with examples of honey aroma compounds, belonging to different chemical classes and containing different elements in their molecules. Examples of compounds whose structures could not be described are also provided. Overall, 84 compounds, from a total of 89 species, could be identified in 19 honey samples from 3 different geographic areas in the world. The suitability of responses measured for selected ions, corresponding to above species, for authentication purposes is assessed through principal components analysis.
    Matched MeSH terms: Solid Phase Microextraction
  2. Shukor MY, Dahalan FA, Jusoh AZ, Muse R, Shamaan NA, Syed MA
    J Environ Biol, 2009 Jan;30(1):145-50.
    PMID: 20112877
    A diesel-degrading bacterium has been isolated from a diesel-polluted site. The isolate was tentatively identified as Staphylococcus aureus strain DRY11 based on partial 16S rDNA molecular phylogeny and Biolog GP microplate panels and Microlog database. Isolate 11 showed an almost linear increase in cellular growth with respect to diesel concentrations with optimum growth occurring at 4% (v/v) diesel concentration. Optimization studies using different nitrogen sources showed that the best nitrogen source was potassium nitrite. Sodium nitrite was optimum at 1.2 g l(-1) and higher concentrations were strongly inhibitory to cellular growth. The optimal pH that supported growth of the bacterium was between 7.5 to 8.0 and the isolate exhibited optimal broad temperature supporting growth on diesel from 27 to 37 degrees C. An almost complete removal of diesel components was seen from the reduction in hydrocarbon peaks observed using Solid Phase Microextraction Gas Chromatography analysis after 5 days of incubation. The characteristics of this bacterium suggest that it is suitable for bioremediation of diesel spills and pollutions in the tropics.
    Matched MeSH terms: Solid Phase Microextraction
  3. Harun N, Anderson RA, Miller EI
    J Anal Toxicol, 2009 8 6;33(6):310-21.
    PMID: 19653934 DOI: 10.1093/jat/33.6.310
    An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (< 10%). Matrix effects analysis showed an average ion suppression of 5.7% for ketamine and an average ion enhancement of 13.0% for norketamine for urine samples collected from six individuals. A comparison of ELISA and LC-MS-MS results demonstrated a sensitivity, specificity, and efficiency of 100%. These results indicated that a cutoff value of 25 ng/mL ketamine in the ELISA screen is particularly suitable and reliable for urine testing in a forensic toxicology setting. Furthermore, both ketamine and norketamine were detected in all 34 urine samples collected from individuals socializing in pubs by the Royal Malaysian Police. Ketamine concentrations detected by LC-MS-MS ranged from 22 to 31,670 ng/mL, and norketamine concentrations ranged from 25 to 10,990 ng/mL. The concentrations of ketamine and norketamine detected in the samples are most ikely indicative of ketamine abuse.
    Matched MeSH terms: Solid Phase Microextraction
  4. Moniruzzaman M, Rodríguez I, Rodríguez-Cabo T, Cela R, Sulaiman SA, Gan SH
    J Chromatogr A, 2014 Nov 14;1368:26-36.
    PMID: 25441341 DOI: 10.1016/j.chroma.2014.09.057
    The suitability of the dispersive liquid-liquid microextraction (DLLME) technique for gas chromatography (GC) characterization of minor organic compounds in honey samples is evaluated. Under optimized conditions, samples were pre-treated by liquid-liquid extraction with acetonitrile followed by DLLME using carbon tetrachloride (CCl4, 0.075 mL) as extractant. The yielded settled phase was analyzed by GC using high resolution time-of-flight (TOF) mass spectrometry (MS). The whole sample preparation process is completed in approximately 10 min, with a total consumption of organic solvents below 4 mL, relative standard deviations lower than 12% and with more than 70 organic compounds, displaying linear retention index in the range from 990 to 2900, identified in the obtained extracts. In comparison with HS SPME extraction, higher peak intensities were attained for most volatile and semi-volatile compounds amenable to both extraction techniques. Furthermore, other species such as highly polar and water soluble benzene acids, long chain fatty acids, esters and flavonoids, which are difficult to concentrate by HS SPME, could be identified in DLLME extracts. Some of the compounds identified in DLLME extracts have been proposed as useful for samples classification and/or they are recognized as markers of honeys from certain geographic areas.
    Matched MeSH terms: Solid Phase Microextraction
  5. Lasekan O
    J Sci Food Agric, 2013 Mar 30;93(5):1055-61.
    PMID: 22936608 DOI: 10.1002/jsfa.5846
    Volatile compounds play a key role in determining the sensory appreciation of vegetable oils. In this study a systematic evaluation of odorants responsible for the characteristic flavour of roasted tigernut oil was carried out.
    Matched MeSH terms: Solid Phase Microextraction
  6. Zakaria SR, Saim N, Osman R, Abdul Haiyee Z, Juahir H
    Molecules, 2018 Sep 16;23(9).
    PMID: 30223605 DOI: 10.3390/molecules23092365
    This study analyzed the volatile organic compounds (VOCs) of three mango varieties (Harumanis, Tong Dam and Susu) for the discrimination of authentic Harumanis from other mangoes. The VOCs of these mangoes were extracted and analysed nondestructively using Head Space-Solid Phase Micro Extraction (HS-SPME) coupled to Gas Chromatography-Mass Spectrometry (GC-MS). Prior to the analytical method, two simple sensory analyses were carried out to assess the ability of the consumers to differentiate between the Harumanis and Tong Dam mangoes as well as their preferences towards these mangoes. On the other hand, chemometrics techniques, such as principal components analysis (PCA), hierarchical clustering analysis (HCA), and discriminant analysis (DA), were used to visualise grouping tendencies of the volatile compounds detected. These techniques were successful in identifying the grouping tendencies of the mango samples according to the presence of their respective volatile compounds, thus enabling the identification of the groups of substances responsible for the discrimination between the authentic and unauthentic Harumanis mangoes. In addition, three ocimene compounds, namely beta-ocimene, trans beta-ocimene, and allo-ocimene, can be considered as chemical markers of the Harumanis mango, as these compounds exist in all Harumanis mango, regardless the different sources of the mangoes obtained.
    Matched MeSH terms: Solid Phase Microextraction
  7. Rozaini MNH, Yahaya N, Saad B, Kamaruzaman S, Hanapi NSM
    Talanta, 2017 Aug 15;171:242-249.
    PMID: 28551135 DOI: 10.1016/j.talanta.2017.05.006
    Molecularly imprinted polymer (MIP) was employed as sorbent in ultrasound assisted emulsification molecularly imprinted polymer micro-solid phase extraction (USAE-MIP-µ-SPE) of bisphenol A (BPA) in water, beverages and the aqueous liquid in canned foods prior to high performance liquid chromatography-diode array detector (HPLC-DAD) analysis. Several effective variables, such as types of emulsification solvent and its volume, types of desorption solvent and its volume, salting out effect, pH of sample solution, mass of sorbent, extraction and desorption time, and sample volume, were optimized comprehensively. Under the optimized USAE-MIP-µ-SPE and HPLC-DAD conditions, the method demonstrated good linearity over the range of 0.5-700μgL-1with a coefficient determination of R2=0.9973, low limit of detection (0.07μgL-1), good analyte recoveries (82.2-118.9%) and acceptable RSDs (0.7-14.2%, n=3) with enrichment factor of 49. The method was applied to thirty samples of drinking water, mineral water, river water, lake water, as well as beverages and canned foods, the presence of BPA was identified in four samples. The proposed method showed good selectivity and reusability for extraction of BPA, and hence the USAE-MIP-µ-SPE is rapid, simple, cost effective and environmentally friendly.
    Matched MeSH terms: Solid Phase Microextraction
  8. Abd Wahib SM, Wan Ibrahim WA, Sanagi MM, Kamboh MA, Abdul Keyon AS
    J Chromatogr A, 2018 Jan 12;1532:50-57.
    PMID: 29241956 DOI: 10.1016/j.chroma.2017.11.059
    A facile dispersive-micro-solid phase extraction (D-μ-SPE) method coupled with HPLC for the analysis of selected non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed using a newly prepared magnetic sporopollenin-cyanopropyltriethoxysilane (MS-CNPrTEOS) sorbent. Sporopollenin homogenous microparticles of Lycopodium clavatum spores possessed accessible functional groups that facilitated surface modification. Simple modification was performed by functionalization with 3-cyanopropyltriethoxysilane (CNPrTEOS) and magnetite was introduced onto the biopolymer to simplify the extraction process. MS-CNPrTEOS was identified by infrared spectrometrywhile the morphology and the magnetic property were confirmed by scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM), respectively. To maximize the extraction performance of ketoprofen, ibuprofen, diclofenac and mefenamic acid using the proposed MS-CNPrTEOS, important D-μ-SPE parameters were comprehensively optimized. The optimum extraction conditions were sorbent amount, 40 mg; extraction time, 5 min; desorption time; 5 min; sample volume, 15 mL; sample pH 2.0; and salt addition, 2.5% (w/v). The feasibility of the developed method was evaluated using spiked tap water, lake water, river water and waste water samples. Results showed that ketoprofen and ibuprofen were linear in the range of 1.0-1000 μg L-1whilst diclofenac and mefenamic acid were linear in the range 0.8-500 μg L-1. The results also showed good detection limits for the studied NSAIDs in the range of 0.21-0.51 μg L-1and good recoveries for spiked water samples in the range of 85.1-106.4%. The MS-CNPrTEOS proved a promising dispersive sorbent and applicable to facile and rapid assay of NSAIDs in water samples.
    Matched MeSH terms: Solid Phase Microextraction*
  9. Ghaemi F, Amiri A
    J Chromatogr A, 2020 Aug 30;1626:461386.
    PMID: 32797858 DOI: 10.1016/j.chroma.2020.461386
    In this study, the microcrystalline cellulose/metal-organic framework 199 hybrid (MCC/MOF-199) was applied as sorbent for the dispersive micro-solid phase-extraction (D-μSPE) of chlorophenols. The D-μSPE method combined with high-performance liquid chromatography- ultraviolet detection (HPLC-UV) was employed to determine of four chlorophenols including 2-chlorophenol (2-CP), 4-chlorophenol (4-CP), 2,3-dichlorophenol (2,3-DCP), and 2,5-dichlorophenol (2,5-DCP) in aqueous. The main parameters of the D-μSPE process that influence the extraction (i.e. the amount of sorbent, elution condition, extraction time, and pH) were investigated and optimized. Based on the outputs, the presence of MCC on the surface of MOF-199 leads to improve the properties of MOF-199 and the MCC/MOF-199 has the highest sorption capacity, durability, and porosity in comparison with MCC and MOF-199. According to the validation study at the optimized conditions, the linearity for the analytes was achieved in the range from 0.1 to 200 ng mL-1 for 2-CP and 4-CP and 0.15 to 200 ng mL-1 for 2,3-DCP and 2,5-DCP with correlation coefficients between 0.9928 and 0.9965. The limits of detection calculated at S/N=3 were in the range of 0.03-0.05 ng mL-1. Besides, the relative standard deviations (RSDs) for three spiking levels (0.2, 10,100 ng mL-1) do not exceed 6.8% and extraction recoveries are between 81.0% and 88.3%. Finally, the D-μSPE-HPLC-UV method was successfully applied to the analysis of CPs in real water samples (mineral, river and wastewater samples) with good recoveries (95.8 to 99.5%) and satisfactory precisions (RSD < 6.8%).
    Matched MeSH terms: Solid Phase Microextraction/methods*
  10. Cheong MW, Zhu D, Sng J, Liu SQ, Zhou W, Curran P, et al.
    Food Chem, 2012 Sep 15;134(2):696-703.
    PMID: 23107680 DOI: 10.1016/j.foodchem.2012.02.139
    Calamansi juices from three countries (Malaysia, the Philippines and Vietnam) were characterised through measuring volatiles, physicochemical properties and non-volatiles (sugars, organic acids and phenolic acids). The volatile components of manually squeezed calamansi juices were extracted using dichloromethane and headspace solid-phase microextraction, and then analysed using gas chromatography-mass spectrometry/flame ionisation detector, respectively. A total of 60 volatile compounds were identified. The results indicated that the Vietnam calamansi juice contained the highest amount of volatiles. Two principal components obtained from principal component analysis (PCA) represented 89.65% of the cumulative total variations of the volatiles. Among the non-volatile components, these three calamansi juices could be, to some extent, differentiated according to fructose and glucose concentrations. Hence, this study of calamansi juices could lead to a better understanding of calamansi fruits.
    Matched MeSH terms: Solid Phase Microextraction
  11. Saad KA, Mohamad Roff MN, Hallett RH, Idris AB
    Sci Rep, 2015;5:13697.
    PMID: 26334135 DOI: 10.1038/srep13697
    The sweetpotato whitefly (WF), Bemisia tabaci, is a major pest that damages a wide range of vegetable crops in Malaysia. WF infestation is influenced by a variety of factors, including previous infestation of the host plant by other insect pests. This study investigated the effects of previous infestation of host chilli plants by the green peach aphid (Myzus persicae) on the olfactory behavioural response of B. tabaci, using free-choice bioassay with a Y-tube olfactometer. We analysed volatile organic compounds (VOCs) emitted by non-infested and M. persicae-infested chilli plants using solid-phase microextraction and gas chromatography-mass spectrometry. Our results showed that female WFs preferred non-infested to pre-infested plants. Collection and analysis of volatile compounds emitted by infested plants confirmed that there were significant increases in the production of monoterpenes (cymene; 1,8-cineole), sesquiterpenes (β-cadinene, α-copaene), and methyl salicylate (MeSA) compared to non-infested plants. Our results suggest that host plant infestation by aphids may induce production of secondary metabolites that deter B. tabaci from settling on its host plants. These results provide important information for understanding WF host selection and dispersal among crops, and also for manipulating WF behaviour to improve IPM in chilli.
    Matched MeSH terms: Solid Phase Microextraction
  12. Chang KH, Yew CH, Abdullah AF
    J Forensic Sci, 2015 Jul;60(4):869-77.
    PMID: 25771708 DOI: 10.1111/1556-4029.12745
    Gunshot residues, produced after shooting activity, have acquired their importance in analysis due to the notoriety of firearms-related crimes. In this study, solid-phase microextraction was performed to extract the headspace composition of spent cartridges using 85-μm polyacrylate fiber at 66°C for 21 min. Organic compounds, that is, naphthalene, 2,6-dinitrotoluene, 2,4-dinitrotoluene, diphenylamine, and dibutyl phthalate were detected and analyzed by gas chromatography-flame ionization detection technique. Evaluation of chromatograms for diphenylamine, dibutyl phthalate, and naphthalene indicates the period after a gunshot was discharged, whether it was 1 days, 2-4 days, <5 days, 10 days, 20 days, or more than 30 days ago. This study revealed the potential effects of environmental factors such as occasional wind blow and direct sunlight on the estimation of time after spent cartridges were discharged. In conclusion, we proposed reliable alternative in analyzing the headspace composition of spent cartridges in a simulated crime scene.
    Matched MeSH terms: Solid Phase Microextraction
  13. Syaidatul Faraha Zainuddin, Siti Raihan Zakaria, Norashikin Saim, Rossuriati Dol Hamid, Rozita Osman
    Science Letters, 2020;14(2):58-70.
    MyJurnal
    Headspace solid phase microextraction (HS-SPME) was employed for the extraction of volatile organic compounds (VOCs) in MD2 pineapple (Ananas comosus L. var. comosus cv. MD2). Optimisation of HS-SPME operating parameters was conducted using three-factor, three-level Box–Behnken response surface experimental design to evaluate the interactive effects of temperature (30 – 50 ºC), extraction time (10 – 30 min) and salting effect (1 – 3 g of salt addition) on the amount of selected VOCs. Determination of VOCs was done using gas chromatography with spectrometry detector (GC-MSD). Extraction temperature was found to be significant (p < 0.05) in increasing the amount of selected VOCs (ethyl acetate, methyl isobutyrate and butanoic acid methyl ester). Based on the maximum amount of these VOCs, the optimum operating extraction conditions for HS-SPME were set up at temperature of 30 °C, time of 29 min and salt addition of 1 g. The optimized HS-SPME conditions were employed for the extraction of VOCs from pineapple of different varieties.
    Matched MeSH terms: Solid Phase Microextraction
  14. Saad KA, Mohamad Roff MN, Hallett RH, Abd-Ghani IB
    Insect Sci, 2019 Feb;26(1):76-85.
    PMID: 28594105 DOI: 10.1111/1744-7917.12488
    Plant virus infections are known to alter host plant attractiveness and suitability for insect herbivores. This study was conducted to determine how cucumber mosaic virus (CMV)-infected chilli plants affect the fitness and settling preferences of nonvector whitefly, Bemisia tabaci adults under dual-choice conditions with volatile organic compounds analyzed using solid phase microextraction coupled with gas chromatography-mass spectrometry (GC-MS). Results showed that the presence of CMV in chilli plants substantially affects the settling preferences of the B. tabaci, which preferred to settle on noninfected plants. Duration of the egg stage and the longevity and fecundity of adult B. tabaci on CMV-infected chilli plants were not markedly different from those on noninfected chilli plants. In contrast, the developmental time from egg to adult was significantly reduced in CMV-infected chilli plants compared to the noninfected plants. The results also showed that CMV-infected chilli plants released significantly more linalool and phenylacetaldehyde than noninfected plants. Overall, it was suggested that the behavioral response of B. tabaci might be modified by CMV-infected plants, which alter the release of specific headspace volatiles. Based on these results, the modification of plant volatile profiles may help in enhancing the effectiveness of biological control and the protection of crop plants against B. tabaci.
    Matched MeSH terms: Solid Phase Microextraction
  15. Kamaruddin AF, Sanagi MM, Wan Ibrahim WA, Md Shukri DS, Abdul Keyon AS
    J Sep Sci, 2017 Nov;40(21):4256-4263.
    PMID: 28851082 DOI: 10.1002/jssc.201700659
    Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole-magnetite dispersive micro-solid phase-extraction conditions were sample pH 8, 60 mg polypyrrole-magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole-magnetite dispersive micro-solid-phase extraction with ultraviolet-visible method showed good linearity in the range of 0.05-7 mg/L (R2  > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4-111.3%) with relative standard deviations 
    Matched MeSH terms: Solid Phase Microextraction
  16. Abdulra'uf LB, Tan GH
    Food Chem, 2015 Jun 15;177:267-73.
    PMID: 25660885 DOI: 10.1016/j.foodchem.2015.01.031
    An HS-SPME method was developed using multivariate experimental designs, which was conducted in two stages. The significance of each factor was estimated using the Plackett-Burman (P-B) design, for the identification of significant factors, followed by the optimization of the significant factors using central composite design (CCD). The multivariate experiment involved the use of Minitab® statistical software for the generation of a 2(7-4) P-B design and CCD matrices. The method performance evaluated with internal standard calibration method produced good analytical figures of merit with linearity ranging from 1 to 500 μg/kg with correlation coefficient greater than 0.99, LOD and LOQ were found between 0.35 and 8.33 μg/kg and 1.15 and 27.76 μg/kg respectively. The average recovery was between 73% and 118% with relative standard deviation (RSD=1.5-14%) for all the investigated pesticides. The multivariate method helps to reduce optimization time and improve analytical throughput.
    Matched MeSH terms: Solid Phase Microextraction/methods*
  17. Khayoon WS, Saad B, Salleh B, Manaf NH, Latiff AA
    Food Chem, 2014 Mar 15;147:287-94.
    PMID: 24206720 DOI: 10.1016/j.foodchem.2013.09.049
    A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography-tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20mg; extraction time, 90 min; stirring speed, 1,000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1, AFB2 and AFB1, respectively were achieved. Good linearity and correlation coefficient was obtained over the concentration range of 0.4-50 ng g(-1) (r(2) 0.9988-0.9999). Good recoveries for AFs ranging from 86.0-109% were obtained. The method was applied to 40 samples involving malt beverage (19) and canned coffee (21). No AFs were detected in the selected samples.
    Matched MeSH terms: Solid Phase Microextraction/methods*
  18. Abdulra'uf LB, Tan GH
    Food Chem, 2013 Dec 15;141(4):4344-8.
    PMID: 23993624 DOI: 10.1016/j.foodchem.2013.07.022
    Solid-phase microextraction (SPME) is a solvent-less sample preparation method which combines sample preparation, isolation, concentration and enrichment into one step. In this study, multivariate strategy was used to determine the significance of the factors affecting the solid phase microextraction of pesticide residues (fenobucarb, diazinon, chlorothalonil and chlorpyrifos) using a randomised factorial design. The interactions and effects of temperature, time and salt addition on the efficiency of the extraction of the pesticide residues were evaluated using 2(3) factorial designs. The analytes were extracted with 100 μm PDMS fibres according to the factorial design matrix and desorbed into a gas chromatography-mass spectrometry detector. The developed method was applied for the analysis of apple samples and the limits of detection were between 0.01 and 0.2 μg kg(-)(1), which were lower than the MRLs for apples. The relative standard deviations (RSD) were between 0.1% and 13.37% with average recovery of 80-105%. The linearity ranges from 0.5-50 μg kg(-)(1) with correlation coefficient greater than 0.99.
    Matched MeSH terms: Solid Phase Microextraction/methods*
  19. Loh SH, Sanagi MM, Wan Ibrahim WA, Hasan MN
    Talanta, 2013 Mar 15;106:200-5.
    PMID: 23598117 DOI: 10.1016/j.talanta.2012.12.032
    A new microextraction procedure termed multi-walled carbon nanotube-impregnated agarose film microextraction (MWCNT-AFME) has been developed. The method utilized multi-walled carbon nanotubes (MWCNTs) immobilized in agarose film to serve as adsorbent in solid phase microextraction (SPME). The film was prepared by mixing the MWCNTs in agarose solution and drying the mixture in oven. Extraction of selected polycyclic aromatic hydrocarbons was performed by inserting a needle through circular MWCNT-impregnated agarose films (5 mm diameter) and the assembly was dipped into an agitated sample solution prior to micro high performance liquid chromatography-ultraviolet analysis. Back extraction was then performed using ultrasonication of the films in 100 μL of solvent. The film was discarded after single use, thus avoiding any analyte carry-over effect. Due to the mesoporous nature of the agarose film, the MWCNTs were immobilized easily within the film and thus allowing for close contact between adsorbent and analytes. Under the optimized extraction conditions, the technique achieved trace LODs in the range of 0.1 to 50 ng L(-1) for the targeted analytes, namely fluoranthene, phenanthrene and benzo[a]pyrene. The method was successfully applied to the analysis of spiked green tea beverage samples with good relative recoveries in the range of 91.1 to 107.2%. The results supported the feasibility of agarose to serve as adsorbent holder in SPME which then minimizes the consumption of chemicals and disposal cost of organic wastes.
    Matched MeSH terms: Solid Phase Microextraction/methods
  20. Lee TP, Saad B, Khayoon WS, Salleh B
    Talanta, 2012 Jan 15;88:129-35.
    PMID: 22265478 DOI: 10.1016/j.talanta.2011.10.021
    A simple, environmental friendly and selective sample preparation technique employing porous membrane protected micro-solid phase extraction (μ-SPE) loaded with molecularly imprinted polymer (MIP) for the determination of ochratoxin A (OTA) is described. After the extraction, the analyte was desorbed using ultrasonication and was analyzed using high performance liquid chromatography. Under the optimized conditions, the detection limits of OTA for coffee, grape juice and urine were 0.06 ng g(-1), 0.02 and 0.02 ng mL(-1), respectively while the quantification limits were 0.19 ng g(-1), 0.06 and 0.08 ng mL(-1), respectively. The recoveries of OTA from coffee spiked at 1, 25 and 50 ng g(-1), grape juice and urine samples at 1, 25 and 50 ng mL(-1) ranged from 90.6 to 101.5%. The proposed method was applied to thirty-eight samples of coffee, grape juice and urine and the presence of OTA was found in eighteen samples. The levels found, however, were all below the legal limits.
    Matched MeSH terms: Solid Phase Microextraction/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links