Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Ismail I, Arliyani, Jalil Z, Mursal, Olaiya NG, Abdullah CK, et al.
    Polymers (Basel), 2020 Sep 28;12(10).
    PMID: 32998404 DOI: 10.3390/polym12102236
    Conventionally, panel boards are produced with material flex or microparticle with P.U. or U.F. as adhesives. However, in this study, nanoparticle with epoxy resin as an adhesive was used to produce nanoboard. Coconut shell nanoparticle composite with epoxy resin as an adhesive was prepared using a compression molding technique. The coconut shell particles were originally 200 mesh size and then milled mechanically with a ball mill for the duration of 10, 20, 30, and 40 h (milling times) to produce nanoparticles. The composition ratio of the composite is 85 vol.% of coconut shell and 15 vol.% of epoxy resin. The formation of nanoparticles was observed with transmission electron microscopy (TEM). The mechanical, physical, and microstructure properties of the composite were examined with X-ray diffraction, scanning electron microscopy, atomic force microscopy, and universal testing machine. The results established that the properties of the composite (microstructures, mechanical, and physical) are influenced by the duration of milling of coconut shell particles. The modulus and flexural strength of the composite improved with an increase in the milling time. The density, thickness swelling, and porosity of the composite were also influenced by the milling times. The result suggested that the composite properties were influenced by the particle size of the coconut shell. The coconut shell nanoparticle composite can be used in the manufacturing of hybrid panels and board.
    Matched MeSH terms: Surgical Mesh
  2. Revathi M, Sivagaami Sundari G, Ahmed Basha C, Alam M, Sagadevan S, Ahmad N
    J Nanosci Nanotechnol, 2020 10 01;20(10):6547-6554.
    PMID: 32385012 DOI: 10.1166/jnn.2020.18562
    This investigation aims at the reclamation of Cr(VI) from synthetic electroplating industrial effluent by electroextraction process namely electrochemical ion exchange (EIX). An electrochemical ion exchange reactor of desired dimensions was fabricated with the help of ion-permeable membranes, stainless steel cathode and PbO₂ coated Ti expanded mesh anode. The performance of the reactor was studied in batch recirculation mode, continuous flow mode at different experimental conditions. The influence of various experimental factors, for instance, initial metal ion concentration (20, 300, 1000 mg/L of Cr(VI)), applied voltages (2.5 V, 5 V, 7.5 V, 10 V) and flow rates of the process stream (2, 4, 6, 8, 10, 12 and 14 ml/min) on removal/reclamation efficiency was deliberated. For comparison purposes, an electrodialysis process was conducted at the same optimal conditions. It was found that the EIX process with three compartments has more removal efficiency at optimum experimental conditions than the electrodialysis process. The continuous flow process of the reactor with 300 mg/L of Cr(VI) as inlet concentration has studied to predict the breakeven point of the reactor. It was noted that Cr(VI) ion concentration in the treated wastewater is almost zero up to the discharge of 20 liters of treated rinse water.
    Matched MeSH terms: Surgical Mesh
  3. Lo TS, Tan YL, Cortes EF, Pue LB, Wu PY, Al-Kharabsheh A
    J Minim Invasive Gynecol, 2015 Jan;22(1):50-6.
    PMID: 25017520 DOI: 10.1016/j.jmig.2014.07.002
    To study the surgical and functional outcomes of single-incision mesh surgery for treatment of advanced pelvic organ prolapse (POP).
    Matched MeSH terms: Surgical Mesh*
  4. Lo TS, Tan YL, Cortes EF, Wu PY, Pue LB, Al-Kharabsheh A
    Aust N Z J Obstet Gynaecol, 2015 Jun;55(3):284-90.
    PMID: 26044791 DOI: 10.1111/ajo.12340
    The Food and Drug Administration has recently highlighted an increase in reported complications associated with the use of transvaginal mesh.
    Matched MeSH terms: Surgical Mesh/adverse effects*
  5. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (Pmesh) was effectively carried out on simulated casts without substantially affecting the amount of similarity in volume and geometry.

    Matched MeSH terms: Surgical Mesh
  6. Chai FY
    World J Surg, 2020 10;44(10):3322-3323.
    PMID: 32524160 DOI: 10.1007/s00268-020-05636-6
    Matched MeSH terms: Surgical Mesh
  7. Pan, K.L., Chan, W.H.
    Malays Orthop J, 2010;4(2):51-53.
    MyJurnal
    Giant cell tumours of bone are best treated by extended curettage and filling in of the defect with cement or bone graft. In more advanced stages, when there is extensive loss of cortical bone cover, containment of the filling material is not possible and resection and reconstruction is required. We report a case of a recurrent giant cell tumour of the distal tibia in a 21-year-old female with extensive cortical bone loss in which polypropylene surgical mesh was used to contain the bone cement, thus avoiding a resection.
    Matched MeSH terms: Surgical Mesh
  8. Agbolade O, Nazri A, Yaakob R, Ghani AAA, Cheah YK
    PeerJ Comput Sci, 2020;6:e249.
    PMID: 33816901 DOI: 10.7717/peerj-cs.249
    Over the years, neuroscientists and psychophysicists have been asking whether data acquisition for facial analysis should be performed holistically or with local feature analysis. This has led to various advanced methods of face recognition being proposed, and especially techniques using facial landmarks. The current facial landmark methods in 3D involve a mathematically complex and time-consuming workflow involving semi-landmark sliding tasks. This paper proposes a homologous multi-point warping for 3D facial landmarking, which is verified experimentally on each of the target objects in a given dataset using 500 landmarks (16 anatomical fixed points and 484 sliding semi-landmarks). This is achieved by building a template mesh as a reference object and applying this template to each of the targets in three datasets using an artificial deformation approach. The semi-landmarks are subjected to sliding along tangents to the curves or surfaces until the bending energy between a template and a target form is minimal. The results indicate that our method can be used to investigate shape variation for multiple datasets when implemented on three databases (Stirling, FRGC and Bosphorus).
    Matched MeSH terms: Surgical Mesh
  9. Kong CY, Lai LL, Khoo AYY, Rahman NA, Chin KF
    BMC Surg, 2016 Feb 11;16:8.
    PMID: 26864939 DOI: 10.1186/s12893-016-0123-8
    BACKGROUND: Polypropylene meshes are widely used in hernia repairs. Hernia meshes have been developed incorporating coatings of active agents. One commercially available mesh has a fish oil coating which is promoted as having anti-inflammatory properties. We report a case, a symptomatic foreign body granuloma reaction associated with a fish oil coated polypropylene mesh, which required eventual mesh explantation.

    CASE PRESENTATION: A 61-year old lady with previous peptic ulcer disease underwent a laparoscopic intraperitoneal placement of mesh for incisional hernia utilising a fish oil coated polypropylene mesh. The patient presented 3 months after the procedure complaining of dyspepsia and pain at the operative site. There was no discharge. The patient was managed conservatively. She presented 10 months post-operatively with progressively worsening symptoms and a hard palpable mass in the epigastrium. Abdominal laparoscopy revealed dense adhesive disease around the mesh with exudates. Adhesiolysis, mesh explantation and a partial gastrectomy was performed. Histopathological examination revealed a foreign body granuloma formation to the mesh.

    CONCLUSION: In-vivo studies looking at intraperitoneal mesh placement with fish oil coatings including data on surgical outcomes such as fistula and adhesive characteristics are scarce in the literature. Further monitoring and studies are required to investigate the safety and efficacy profile of this mesh type in in-vivo models.

    Matched MeSH terms: Surgical Mesh/adverse effects*
  10. Zauki NAM, Satyanarayana B, Fairuz-Fozi N, Nelson BR, Martin MB, Akbar-John B, et al.
    Data Brief, 2019 Feb;22:458-463.
    PMID: 30619923 DOI: 10.1016/j.dib.2018.12.027
    The data available in this repository were gathered from Balok, the only most productive spawning site for horseshoe crabs Tachypleus gigas and Carcinoscorpius rotundicauda in East Coast of Peninsular Malaysia. The mangrove horseshoe crab, C. rotundicauda population and spawning data are available in the first table. The horseshoe crabs were retrieved from Balok River using 11.43 cm mesh size gill nets installed at the river mouth, the confluence and last meander. The arthropods were inspected for damage, abnormality and growth before their release into Balok River, particularly at the site of capture. Sediment samples were retrieved at their spawning grounds to ascertain sediment composition and size classifications which were also processed using Logarithmic Method of Moments. Water parameters like temperature, pH and salinity were also investigated during year 2016. All these information are compiled into the second table and arranged according to the period of data availability. The horseshoe crab catch data of years 2012, 2013, 2014, 2015 and 2016 were made available by artisanal fisher and compiled in the third and fourth table for inter-species comparison.
    Matched MeSH terms: Surgical Mesh
  11. Yussra Y, Sutton PA, Kosai NR, Razman J, Mishra RK, Harunarashid H, et al.
    Clin Ter, 2013;164(5):425-8.
    PMID: 24217830 DOI: 10.7417/CT.2013.1608
    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.
    Matched MeSH terms: Surgical Mesh
  12. Liew W, Wai YY, Kosai NR, Gendeh HS
    Hernia, 2017 08;21(4):549-554.
    PMID: 28417279 DOI: 10.1007/s10029-017-1611-1
    PURPOSE: Laparoscopic hernioplasty has become a popular choice for inguinal hernia repair since its advent in 1990s. Postoperative pain is an undesirable clinical outcome impairing daily activity of 22.5% of patients. The aim of this study is to evaluate postoperative acute and chronic pain via inflammatory markers as an objective assessment following tacks or glue mesh fixation in TEP repair.

    METHODS: Sixty-six (66) patients with unilateral uncomplicated inguinal hernia were randomized into 34 patients in the tacker and 32 patients in cyanoacrylate glue mesh fixation in TEP repair. The extent of surgical trauma was evaluated by measuring inflammatory markers of C-reactive protein, white blood cell count at 48 h, and ESR at 3 months postoperatively. Postoperative acute and chronic pain was assessed by recording the visual analogue scale scores and surgical complications were recorded over 3 months of the study period.

    RESULTS: The median CRP and WBC levels at postoperative 48 h in both groups raised significantly from the baseline values (p  0.05). The median ESR level increased significantly at 3 months postoperatively from baseline in the glue mesh fixation group only (p  0.05). There was no significant difference for VAS scores at all timelines between the tacker and glue mesh fixation group (p > 0.05).

    CONCLUSION: Cyanoacrylate glue mesh fixation technique as an alternative method to mechanical fixation in TEP repair is comparable to tacker and can be considered to be safe and feasible.

    Matched MeSH terms: Surgical Mesh*
  13. Dharmaraj B, Diong NC, Shamugam N, Sathiamurthy N, Mohd Zainal H, Chai SC, et al.
    Indian J Thorac Cardiovasc Surg, 2021 Jan;37(1):82-88.
    PMID: 33442211 DOI: 10.1007/s12055-020-00972-7
    Chest wall resection is defined as partial or full-thickness removal of the chest wall. Significant morbidity has been recorded, with documented respiratory failure as high as 27%. Medical records of all patients who had undergone chest wall resection and reconstruction were reviewed. Patients' demographics, length of surgery, reconstruction method, size of tumor and chest wall defect, histopathological result, complications, duration of post-operative antibiotics, and hospital stay were assessed. From 1 April 2017 to 30 April 2019, a total of 20 patients underwent chest wall reconstructive surgery. The median age was 57 years, with 12 females and 8 males. Fourteen patients (70%) had malignant disease and 6 patients (30%) had benign disease. Nine patients underwent rigid reconstruction (titanium mesh for sternum and titanium plates for ribs), 6 patients had non-rigid reconstruction (with polypropylene or composite mesh), and 5 patients had primary closure. Nine patients (45%) required closure with myocutaneous flap. Complications were noted in 70% of patients. Patients who underwent primary closure had minor complications. In total, 66.7% of patients who had closure with either fasciocutaneous or myocutaneous flaps had threatened flap necrosis. Two patients developed pneumonia and 3 patients (15%) had respiratory failure requiring tracheostomy and prolonged ventilation. There was 1 mortality (5%) in this series. In conclusion, chest wall resections involving large defects require prudent clinical judgment and multidisciplinary assessments in determining the choice of chest wall reconstruction to improve outcomes.
    Matched MeSH terms: Surgical Mesh
  14. Lo TS, Harun F, Chua S, Shen YH, Tan YL, Hsieh WC
    J Formos Med Assoc, 2024 Mar;123(3):331-339.
    PMID: 37996329 DOI: 10.1016/j.jfma.2023.11.003
    BACKGROUND AND PURPOSE: We present this current study to complement with mesh inlays plausible benefits (UPHOLD-LITE System) on available long-term study amidst FDA's concern on mesh complications. This study aims to assess the medium-term outcomes of UPHOLD-LITE system for treatment of advanced pelvic organ prolapse (POP) and its complications, and lower urinary tract symptoms.

    METHODS: This is a retrospective case series of 53 months follow-up of 123 consecutive patients who underwent UPHOLD-LITE system. Objective outcome measures the anatomical correction of prolapse with POP-Q ≤ Stage 1. Subjective outcome was patient's feedback to questions 2 and 3 of POPDI-6. Secondary outcome measures the quality of life, presence of lower urinary tract symptoms and complications. Quality of life is assessed by validated questionnaires on Urogenital Distress Inventory 6 (UDI-6), Incontinence Impact Questionnaire 7 (IIQ-7), Pelvic Organ Prolapse Distress Inventory 6 (POPDI-6), and Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire 12 (PISQ-12) at 1 and 3 years post-operatively.

    RESULTS: Objective outcome at 1 and 3 years was at 96.7 % and 95.4 % respectively. The subjective cure was 95.1 % and 91.6 %. Five-year cumulative cure rate maintained at 87.2 %. Secondary outcomes observed improvement on UDI-6, IIQ-7, POPDI-6 and PISQ-12 postoperatively. Bladder outlet obstruction improved while de novo urodynamic stress incontinence (USI) increased slightly post surgically. Mesh erosion rate was 0.8 %.

    CONCLUSION: The UPHOLD-LITE system demonstrated good medium term anatomical correction of apical and anterior prolapse, with good subjective cure and improved quality of life. Whilst complication rate was low, slight increase in de novo USI was observed.

    Matched MeSH terms: Surgical Mesh
  15. Lo TS, Jaili S, Uy-Patrimonio MC, Karim NB, Ibrahim R
    J Obstet Gynaecol Res, 2017 Mar;43(3):543-550.
    PMID: 28160508 DOI: 10.1111/jog.13234
    AIM: The aim of this study was to evaluate the management outcomes of advanced pelvic organ prolapse (POP) in nulliparous women.

    METHODS: Eight nulliparous women diagnosed with POP ≥ stage 3 between January 2005 and August 2013, according to the Pelvic Organ Quantification System (POPQ), were reviewed. Seven were managed surgically and one was managed with pessary. Primary outcome was surgical objective cure (POP-Q ≤ 1) and subjective cure, defined as negative response to questions 2 and 3 on Pelvic Organ Prolapse Distress Inventory 6. Secondary outcomes were complications, symptoms' severity and quality of life according to validated questionnaires.

    RESULTS: A total of 1275 prolapse patients with POP-Q ≥ stage 3 were managed surgically, among whom seven (0.55%) were nulliparous. Each woman had at least one risk factor associated with POP. Risk factors identified were history of pelvic trauma, obesity, menopause, chronic cough, hard physical labor and constipation. Five patients underwent surgical correction (vaginal hysterectomy with sacrospinous fixation) with mesh (Perigee, n = 3; Avaulta, n = 2). Two patients had uterine preservation without mesh (hysteropexy with sacrospinous ligament fixation). One patient preferred treatment with pessary. The total cure rate (objective and subjective cure rates) was 86% after surgical reconstructive surgery.

    CONCLUSION: Management of nulliparous advanced POP poses significant challenges with regard to uterine preservation, future pregnancy and childbirth. Conservative management with pessary insertion should be offered followed by surgical correction. Reconstructive surgery with mesh may improve prolapse symptoms objectively and subjectively.

    Matched MeSH terms: Surgical Mesh
  16. Farook TH, Barman A, Abdullah JY, Jamayet NB
    J Prosthodont, 2021 Jun;30(5):420-429.
    PMID: 33200429 DOI: 10.1111/jopr.13286
    PURPOSE: Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application.

    MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.

    RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.

    CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.

    Matched MeSH terms: Surgical Mesh
  17. Razman J, Shaharin S, Lukman MR, Sukumar N, Jasmi AY
    Med J Malaysia, 2006 Jun;61(2):142-6.
    PMID: 16898302 MyJurnal
    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.
    Matched MeSH terms: Surgical Mesh
  18. Chan KY, Rohaizak M, Sukumar N, Shaharuddin S, Jasmi AY
    Asian J Surg, 2004 Oct;27(4):306-12.
    PMID: 15564185
    To assess the outcome of inguinal hernia repaired by surgical trainees at Universiti Kebangsaan Malaysia Hospital.
    Matched MeSH terms: Surgical Mesh
  19. Chattu VK, Knight WA, Adisesh A, Yaya S, Reddy KS, Di Ruggiero E, et al.
    Health Promot Perspect, 2021;11(1):20-31.
    PMID: 33758752 DOI: 10.34172/hpp.2021.04
    Background: Africa is facing the triple burden of communicable diseases, non-communicable diseases (NCDs), and nutritional disorders. Multilateral institutions, bilateral arrangements, and philanthropies have historically privileged economic development over health concerns. That focus has resulted in weak health systems and inadequate preparedness when there are outbreaks of diseases. This review aims to understand the politics of disease control in Africa and global health diplomacy's (GHD's) critical role. Methods: A literature review was done in Medline/PubMed, Web of Science, Scopus, Embase, and Google scholar search engines. Keywords included MeSH and common terms related to the topics: "Politics," "disease control," "epidemics/ endemics," and "global health diplomacy" in the "African" context. The resources also included reports of World Health Organization, United Nations and resolutions of the World Health Assembly (WHA). Results: African countries continue to struggle in their attempts to build health systems for disease control that are robust enough to tackle the frequent epidemics that plague the continent. The politics of disease control requires the crafting of cooperative partnerships to accommodate the divergent interests of multiple actors. Recent outbreaks of COVID-19 and Ebola had a significant impact on African economies. It is extremely important to prioritize health in the African development agendas. The African Union (AU) should leverage the momentum of the rise of GHD to (i) navigate the politics of global health governance in an interconnected world(ii) develop robust preparedness and disease response strategies to tackle emerging and reemerging disease epidemics in the region (iii) address the linkages between health and broader human security issues driven by climate change-induced food, water, and other insecurities (iv) mobilize resources and capacities to train health officials in the craft of diplomacy. Conclusion: The AU, Regional Economic Communities (RECs), and African Centres for Disease Control should harmonize their plans and strategies and align them towards a common goal that integrates health in African development agendas. The AU must innovatively harness the practice and tools of GHD towards developing the necessary partnerships with relevant actors in the global health arena to achieve the health targets of the Sustainable Development Goals.
    Matched MeSH terms: Surgical Mesh
  20. Marlina Tanty Ramli Hamid, Mohd Shukry Mohd Khalid, Kartini Rahmat
    MyJurnal
    Obturator hernia is rare, but it must be considered in elderly patients who present with small
    bowel obstruction. The diagnosis is challenging unless there is a high index of suspicion as
    the presenting symptoms and signs are usually non-specific. Presence of positive HowshipRomberg sign is considered pathognomonic. Early diagnosis and rapid surgical intervention
    will reduce the high morbidity and mortality associated with undiagnosed obturator hernia. We
    report a case of a 93-year-old female patient who was admitted to our surgical department with
    symptoms of intestinal obstruction of 3-days duration. Howship-Romberg sign was negative.
    Computed tomography (CT) demonstrated the presence of left obturator hernia with proximal
    small bowel obstruction and no sign of strangulation. The patient had emergency laparotomy
    post-CT where the incarcerated bowel loop was released and the obstructed bowel was
    decompressed without any complication. The hernial defect was close with a mesh and the
    patient had an uneventful recovery post-surgery. In this case, we highlight that diagnosis of
    obturator hernia must always be considered in elderly patients who present with intestinal
    obstruction. Urgent CT could establish a rapid pre-operative diagnosis and aids in appropriate
    surgical intervention planning which is crucial in optimising the outcome.
    Matched MeSH terms: Surgical Mesh
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links