Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Lo TS, Yusoff FM, Kao CC, Jaili S, Uy Patrimonio MC
    Taiwan J Obstet Gynecol, 2017 Jun;56(3):346-352.
    PMID: 28600046 DOI: 10.1016/j.tjog.2017.04.015
    OBJECTIVE: Transvaginal mesh anterior-posterior (TVM-AP) provides better cure rates in the surgical treatment of vaginal cuff eversion than anterior transvaginal mesh combined with sacrospinous ligament fixation (TVM-A). We determine the outcomes after TVM-A and TVM-AP surgeries in advanced vaginal cuff prolapse.

    MATERIALS AND METHODS: The charts of 796 women who underwent pelvic organ prolapse (POP) surgery from July 2006 to January 2012 in Chang Gung Memorial Hospitals were reviewed. We included women who presented with advanced cuff eversion and treated with TVM surgery. Data were analysed after three years post-surgery. Descriptive statistics were used for demographic and perioperative data. The paired-samples t test was used for comparison of preoperative and postoperative continuous data. The outcomes measured were objective cure (POP-Q stage ≤ 1) and subjective cure (negative response to question 2 and 3 on POPDI-6).

    RESULTS: A total of 97 patients was analysed. 61 patients had TVM-A and 36 patients had TVM-AP insertion. Mean follow-up was 52 months. The objective cure rate for TVM-AP was significantly higher than TVM-A, 94.4% versus 80.3%. TVM-AP also showed a higher subjective cure rate (91.7%) though there was no significant difference from TVM-A (p = 0.260). The mesh extrusion rate was low at 3.1% with no major complications seen. In TVM-A the blood loss was lesser and the operation time was shorter.

    CONCLUSION: TVM-AP showed better objective cure rate than TVM-A at 52 months. However, TVM-A is less invasive in comparison with an acceptably good cure rates.

    Matched MeSH terms: Surgical Mesh*
  2. Lo TS, Tan YL, Cortes EF, Pue LB, Wu PY, Al-Kharabsheh A
    J Minim Invasive Gynecol, 2015 Jan;22(1):50-6.
    PMID: 25017520 DOI: 10.1016/j.jmig.2014.07.002
    To study the surgical and functional outcomes of single-incision mesh surgery for treatment of advanced pelvic organ prolapse (POP).
    Matched MeSH terms: Surgical Mesh*
  3. Lo TS, Cortes EFM, Wu PY, Tan YL, Al-Kharabsheh A, Pue LB
    Eur J Obstet Gynecol Reprod Biol, 2016 Mar;198:138-144.
    PMID: 26849040 DOI: 10.1016/j.ejogrb.2016.01.004
    OBJECTIVE: To evaluate the sonologic and clinical outcome of collagen coated (CC) versus non-collagen coated (NC) anterior vaginal mesh (AVM) for pelvic organ prolapse (POP) surgery.

    STUDY DESIGN: The study is a prospective observational study which included 122 patients who had symptomatic POP stage III and IV. AvaultaPlus™ (collagen coated, CC group) was compared to Perigee™ (non collagen coated, NC group). Introital ultrasound morphology, measure of neovascularization by color Doppler and clinical outcomes were assessed. Student t test was used for comparison of pre- and post-operation continuous data (p value of <0.05).

    RESULTS: A total of 110 (CC group=50, NC group=60) women completed the study. A woman in the CC group developed ureteral injury. Both groups had comparable morphologic and clinical outcomes however, the onset of changes in mesh thickness and neovascularization occurred earlier in the NC group (1 month) compared to the CC group (6 months to 1 year).

    CONCLUSION: CC group was comparable to the NC group in terms of erosion rate, ultrasound and clinical assessment. Collagen coating may induce delayed inflammatory response however may also delay tissue integration. The onset of changes in mesh thickness and neovascularization may give us an insight toward utilization of collagen coated mesh for host-tissue integration.

    Matched MeSH terms: Surgical Mesh*
  4. Lo TS, Tan YL, Khanuengkitkong S, Dass AK, Cortes EF, Wu PY
    J Minim Invasive Gynecol, 2014 Sep-Oct;21(5):753-61.
    PMID: 24607796 DOI: 10.1016/j.jmig.2014.02.013
    STUDY OBJECTIVE: To assess the morphologic features of anterior armed transobturator collagen-coated polypropylene mesh and its clinical outcomes in pelvic reconstructive surgery to treat pelvic organ prolapse.
    DESIGN: Evidence obtained from several timed series with intervention (Canadian Task Force classification II-3).
    SETTING: Chang Gung Memorial Hospital, Taoyuan, Taiwan, China.
    PATIENTS: Between April 2010 and October 2012, 70 patients underwent surgery to treat symptomatic pelvic organ prolapse, stage III/IV according to the POP-Q (Pelvic Organ Quantification System).
    INTERVENTION: Anterior armed transobturator collagen-coated mesh.
    MEASUREMENT AND MAIN RESULTS: Morphologic findings and clinical outcome were measured. Morphologic features were assessed via 2-dimensional introital ultrasonography and Doppler studies. Clinical outcome was measured via subjective and objective outcome. Objective outcome was assessed via the 9-point site-specific staging method of the International Continence Society Pelvic Organ Prolapse Quantification before the operation and at 1-year postoperative follow-up. Subjective outcome was based on 4 validated questionnaires: the 6-item UDI-6 (Urogenital Distress Inventory), the 7-item IIQ-7 (Incontinence Impact Questionnaire), the 6-item POPDI-6 (Pelvic Organ Prolapse Distress Inventory 6), and the 12-item PISQ-12 (Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire), at baseline and at 12 months after the operation. Data were obtained for 65 patients who underwent the combined surgery and were able to comply with follow-up for >1 year. Ultrasound studies reveal that mesh length tends to shorten and decrease in thickness over the 1-year follow-up. Vagina thickness also was reduced. Neovascularization through the mesh was observed in <8.5% of patients in the first month and at 1 year, and was evident in approximately 83%. The mesh exposure rate was 6.4%. The recorded objective cure was 90.8% (59 of 65 patients), and subjective cure was 89.2% (58 of 65 patients) at mean (SD) follow-up of 19.40 (10.98) months. At 2 years, UDI-6, IIQ-7, and POPDI-6 scores were all significantly decreased (p < .001), whereas the PISQ-12 score was significantly increased (p = .01).
    CONCLUSIONS: Ultrasound features suggest that the degeneration of collagen barrier may be longer than expected and that integration of collagen-coated mesh could occur up to 1 year. A substantially good clinical outcome was noted.
    KEYWORDS: Anterior vaginal mesh; Collagen-coated mesh; Morphology; Outcome; Pelvic organ prolapse
    Matched MeSH terms: Surgical Mesh*
  5. Lo TS, Lin YH, Chu HC, Cortes EF, Pue LB, Tan YL, et al.
    J Obstet Gynaecol Res, 2017 Jan;43(1):173-178.
    PMID: 27762470 DOI: 10.1111/jog.13158
    AIM: By investigating the association of urodynamics and urogenital nerve growth factor (NGF) levels in vaginal mesh surgery, we may be able to associate the likelihood of postoperative lower urinary tract symptoms developing as a result of synthetic mesh implanted for pelvic floor reconstructive surgery.

    METHODS: Thirty-eight female Sprague-Dawley rats were divided into three groups: mesh, sham (no mesh), and control. Urodynamic study and NGF analysis of the urogenital tissues were done and results were compared among all groups. The urodynamic studies of the mesh and sham groups were further divided into the 4th and 10th days. A P-value mesh and sham groups when compared to the control. The mesh group showed a larger area of inflammation as compared to the sham. The NGF levels increased significantly in the mesh and sham groups on the 4th and 10th days when compared to the control (P < 0.001, P < 0.001, respectively). Both the mesh and sham groups had shorter voiding interval and lower voiding volume on days 4 and 10 when compared to the control group (P mesh group than the sham group.

    CONCLUSION: A higher level of NGF in the early days post-transvaginal mesh implantation is associated with a shorter voiding interval and a smaller bladder capacity, which represents abnormal lower urinary tract symptoms following transvaginal mesh implantation.

    Matched MeSH terms: Surgical Mesh*
  6. Dharmaraj B, Diong NC, Shamugam N, Sathiamurthy N, Mohd Zainal H, Chai SC, et al.
    Indian J Thorac Cardiovasc Surg, 2021 Jan;37(1):82-88.
    PMID: 33442211 DOI: 10.1007/s12055-020-00972-7
    Chest wall resection is defined as partial or full-thickness removal of the chest wall. Significant morbidity has been recorded, with documented respiratory failure as high as 27%. Medical records of all patients who had undergone chest wall resection and reconstruction were reviewed. Patients' demographics, length of surgery, reconstruction method, size of tumor and chest wall defect, histopathological result, complications, duration of post-operative antibiotics, and hospital stay were assessed. From 1 April 2017 to 30 April 2019, a total of 20 patients underwent chest wall reconstructive surgery. The median age was 57 years, with 12 females and 8 males. Fourteen patients (70%) had malignant disease and 6 patients (30%) had benign disease. Nine patients underwent rigid reconstruction (titanium mesh for sternum and titanium plates for ribs), 6 patients had non-rigid reconstruction (with polypropylene or composite mesh), and 5 patients had primary closure. Nine patients (45%) required closure with myocutaneous flap. Complications were noted in 70% of patients. Patients who underwent primary closure had minor complications. In total, 66.7% of patients who had closure with either fasciocutaneous or myocutaneous flaps had threatened flap necrosis. Two patients developed pneumonia and 3 patients (15%) had respiratory failure requiring tracheostomy and prolonged ventilation. There was 1 mortality (5%) in this series. In conclusion, chest wall resections involving large defects require prudent clinical judgment and multidisciplinary assessments in determining the choice of chest wall reconstruction to improve outcomes.
    Matched MeSH terms: Surgical Mesh
  7. Lo TS, Tan YL, Cortes EF, Wu PY, Pue LB, Al-Kharabsheh A
    Aust N Z J Obstet Gynaecol, 2015 Jun;55(3):284-90.
    PMID: 26044791 DOI: 10.1111/ajo.12340
    The Food and Drug Administration has recently highlighted an increase in reported complications associated with the use of transvaginal mesh.
    Matched MeSH terms: Surgical Mesh/adverse effects*
  8. Tan YL, Lo TS, Khanuengkitkong S, Krishna Dass A
    Taiwan J Obstet Gynecol, 2014 Sep;53(3):348-54.
    PMID: 25286789 DOI: 10.1016/j.tjog.2013.08.004
    The objective of this study was to estimate the association of vaginal sacrospinous ligament fixation with anterior-transobturator mesh repair surgery for advanced pelvic organ prolapse in patients of two different age groups.
    Matched MeSH terms: Surgical Mesh*
  9. Pan, K.L., Chan, W.H.
    Malays Orthop J, 2010;4(2):51-53.
    MyJurnal
    Giant cell tumours of bone are best treated by extended curettage and filling in of the defect with cement or bone graft. In more advanced stages, when there is extensive loss of cortical bone cover, containment of the filling material is not possible and resection and reconstruction is required. We report a case of a recurrent giant cell tumour of the distal tibia in a 21-year-old female with extensive cortical bone loss in which polypropylene surgical mesh was used to contain the bone cement, thus avoiding a resection.
    Matched MeSH terms: Surgical Mesh
  10. Zauki NAM, Satyanarayana B, Fairuz-Fozi N, Nelson BR, Martin MB, Akbar-John B, et al.
    Data Brief, 2019 Feb;22:458-463.
    PMID: 30619923 DOI: 10.1016/j.dib.2018.12.027
    The data available in this repository were gathered from Balok, the only most productive spawning site for horseshoe crabs Tachypleus gigas and Carcinoscorpius rotundicauda in East Coast of Peninsular Malaysia. The mangrove horseshoe crab, C. rotundicauda population and spawning data are available in the first table. The horseshoe crabs were retrieved from Balok River using 11.43 cm mesh size gill nets installed at the river mouth, the confluence and last meander. The arthropods were inspected for damage, abnormality and growth before their release into Balok River, particularly at the site of capture. Sediment samples were retrieved at their spawning grounds to ascertain sediment composition and size classifications which were also processed using Logarithmic Method of Moments. Water parameters like temperature, pH and salinity were also investigated during year 2016. All these information are compiled into the second table and arranged according to the period of data availability. The horseshoe crab catch data of years 2012, 2013, 2014, 2015 and 2016 were made available by artisanal fisher and compiled in the third and fourth table for inter-species comparison.
    Matched MeSH terms: Surgical Mesh
  11. Kong CY, Lai LL, Khoo AYY, Rahman NA, Chin KF
    BMC Surg, 2016 Feb 11;16:8.
    PMID: 26864939 DOI: 10.1186/s12893-016-0123-8
    BACKGROUND: Polypropylene meshes are widely used in hernia repairs. Hernia meshes have been developed incorporating coatings of active agents. One commercially available mesh has a fish oil coating which is promoted as having anti-inflammatory properties. We report a case, a symptomatic foreign body granuloma reaction associated with a fish oil coated polypropylene mesh, which required eventual mesh explantation.

    CASE PRESENTATION: A 61-year old lady with previous peptic ulcer disease underwent a laparoscopic intraperitoneal placement of mesh for incisional hernia utilising a fish oil coated polypropylene mesh. The patient presented 3 months after the procedure complaining of dyspepsia and pain at the operative site. There was no discharge. The patient was managed conservatively. She presented 10 months post-operatively with progressively worsening symptoms and a hard palpable mass in the epigastrium. Abdominal laparoscopy revealed dense adhesive disease around the mesh with exudates. Adhesiolysis, mesh explantation and a partial gastrectomy was performed. Histopathological examination revealed a foreign body granuloma formation to the mesh.

    CONCLUSION: In-vivo studies looking at intraperitoneal mesh placement with fish oil coatings including data on surgical outcomes such as fistula and adhesive characteristics are scarce in the literature. Further monitoring and studies are required to investigate the safety and efficacy profile of this mesh type in in-vivo models.

    Matched MeSH terms: Surgical Mesh/adverse effects*
  12. Abdul Azam F', Razak Z, Md Radzi MKF, Muhamad N, Che Haron CH, Sulong AB
    Polymers (Basel), 2020 Sep 13;12(9).
    PMID: 32933225 DOI: 10.3390/polym12092083
    The incorporation of kenaf fiber fillers into a polymer matrix has been pronounced in the past few decades. In this study, the effect of multiwalled carbon nanotubes (MWCNTs) with a short kenaf fiber (20 mesh) with polypropylene (PP) added was investigated. The melt blending process was performed using an internal mixer to produce polymer composites with different filler contents, while the suitability of this melt composite for the injection molding process was evaluated. Thermogravimetric analysis (TGA) was carried out to investigate the thermal stability of the raw materials. Rheological analyses were conducted by varying the temperature, load factor, and filler content. The results demonstrate a non-Newtonian pseudoplastic behavior in all samples with changed kenaf fillers (10 to 40 wt %) and MWCNT contents (1 to 4 wt %), which confirm the suitability of the feedstock for the injection molding process. The addition of MWCNTs had an immense effect on the viscosity and an enormous reduction in the feedstock flow behavior. The main contribution of this work is the comprehensive observation of the rheological characteristics of newly produced short PP/kenaf composites that were altered after MWCNT additions. This study also presented an adverse effect on the composites containing MWCNTs, indicating a hydrophilic property with improved water absorption stability and the low flammability effect of PP/kenaf/MWCNT composites. This PP/kenaf/MWCNT green composite produced through the injection molding technique has great potential to be used as car components in the automotive industry.
    Matched MeSH terms: Surgical Mesh
  13. Lo TS, Tan YL, Cortes EF, Lin YH, Wu PY, Pue LB
    Aust N Z J Obstet Gynaecol, 2015 Dec;55(6):593-600.
    PMID: 26299981 DOI: 10.1111/ajo.12397
    To clinically and sonographically evaluate the influence of anterior vaginal mesh (AVM) surgery with concomitant mid-urethral sling surgery (MUS) for stress urinary incontinence (SUI).
    Matched MeSH terms: Surgical Mesh*
  14. Chan KY, Rohaizak M, Sukumar N, Shaharuddin S, Jasmi AY
    Asian J Surg, 2004 Oct;27(4):306-12.
    PMID: 15564185
    To assess the outcome of inguinal hernia repaired by surgical trainees at Universiti Kebangsaan Malaysia Hospital.
    Matched MeSH terms: Surgical Mesh
  15. Razman J, Shaharin S, Lukman MR, Sukumar N, Jasmi AY
    Med J Malaysia, 2006 Jun;61(2):142-6.
    PMID: 16898302 MyJurnal
    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.
    Matched MeSH terms: Surgical Mesh
  16. Agbolade O, Nazri A, Yaakob R, Ghani AAA, Cheah YK
    PeerJ Comput Sci, 2020;6:e249.
    PMID: 33816901 DOI: 10.7717/peerj-cs.249
    Over the years, neuroscientists and psychophysicists have been asking whether data acquisition for facial analysis should be performed holistically or with local feature analysis. This has led to various advanced methods of face recognition being proposed, and especially techniques using facial landmarks. The current facial landmark methods in 3D involve a mathematically complex and time-consuming workflow involving semi-landmark sliding tasks. This paper proposes a homologous multi-point warping for 3D facial landmarking, which is verified experimentally on each of the target objects in a given dataset using 500 landmarks (16 anatomical fixed points and 484 sliding semi-landmarks). This is achieved by building a template mesh as a reference object and applying this template to each of the targets in three datasets using an artificial deformation approach. The semi-landmarks are subjected to sliding along tangents to the curves or surfaces until the bending energy between a template and a target form is minimal. The results indicate that our method can be used to investigate shape variation for multiple datasets when implemented on three databases (Stirling, FRGC and Bosphorus).
    Matched MeSH terms: Surgical Mesh
  17. Farook TH, Barman A, Abdullah JY, Jamayet NB
    J Prosthodont, 2021 Jun;30(5):420-429.
    PMID: 33200429 DOI: 10.1111/jopr.13286
    PURPOSE: Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application.

    MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.

    RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.

    CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.

    Matched MeSH terms: Surgical Mesh
  18. Rengarajoo J, Harun RH, Royan SJ, Kohir S, Mamat MR
    Ann R Coll Surg Engl, 2022 Jul;104(7):556.
    PMID: 35174718 DOI: 10.1308/rcsann.2021.0299
    Matched MeSH terms: Surgical Mesh
  19. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (Pmesh) was effectively carried out on simulated casts without substantially affecting the amount of similarity in volume and geometry.

    Matched MeSH terms: Surgical Mesh
  20. Chattu VK, Knight WA, Adisesh A, Yaya S, Reddy KS, Di Ruggiero E, et al.
    Health Promot Perspect, 2021;11(1):20-31.
    PMID: 33758752 DOI: 10.34172/hpp.2021.04
    Background: Africa is facing the triple burden of communicable diseases, non-communicable diseases (NCDs), and nutritional disorders. Multilateral institutions, bilateral arrangements, and philanthropies have historically privileged economic development over health concerns. That focus has resulted in weak health systems and inadequate preparedness when there are outbreaks of diseases. This review aims to understand the politics of disease control in Africa and global health diplomacy's (GHD's) critical role. Methods: A literature review was done in Medline/PubMed, Web of Science, Scopus, Embase, and Google scholar search engines. Keywords included MeSH and common terms related to the topics: "Politics," "disease control," "epidemics/ endemics," and "global health diplomacy" in the "African" context. The resources also included reports of World Health Organization, United Nations and resolutions of the World Health Assembly (WHA). Results: African countries continue to struggle in their attempts to build health systems for disease control that are robust enough to tackle the frequent epidemics that plague the continent. The politics of disease control requires the crafting of cooperative partnerships to accommodate the divergent interests of multiple actors. Recent outbreaks of COVID-19 and Ebola had a significant impact on African economies. It is extremely important to prioritize health in the African development agendas. The African Union (AU) should leverage the momentum of the rise of GHD to (i) navigate the politics of global health governance in an interconnected world(ii) develop robust preparedness and disease response strategies to tackle emerging and reemerging disease epidemics in the region (iii) address the linkages between health and broader human security issues driven by climate change-induced food, water, and other insecurities (iv) mobilize resources and capacities to train health officials in the craft of diplomacy. Conclusion: The AU, Regional Economic Communities (RECs), and African Centres for Disease Control should harmonize their plans and strategies and align them towards a common goal that integrates health in African development agendas. The AU must innovatively harness the practice and tools of GHD towards developing the necessary partnerships with relevant actors in the global health arena to achieve the health targets of the Sustainable Development Goals.
    Matched MeSH terms: Surgical Mesh
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links