Displaying publications 1 - 20 of 58 in total

Abstract:
Sort:
  1. Donnelly CJ, Weir G, Jackson C, Alderson J, Rafeeuddin R, Sharir R, et al.
    Sports Biomech, 2024 Mar;23(3):324-334.
    PMID: 33886425 DOI: 10.1080/14763141.2020.1860254
    Much inter-intra-tester kinematic and kinetic repeatability research exists, with a paucity investigating inter-laboratory equivalence. The objective of this research was to evaluate the inter-laboratory equivalence between time varying unplanned kinematics and moments of unplanned sidestepping (UnSS). Eight elite female athletes completed an established UnSS procedure motion capture laboratories in the UK and Australia. Three dimensional time varying unplanned sidestepping joint kinematics and moments were compared. Discrete variables were change of direction angles and velocity. Waveform data were compared using mean differences, 1D 95%CI and RMSE. Discrete variables were compared using 0D 95% CI. The mean differences and 95%CI for UnSS kinematics broadly supported equivalence between laboratories (RMSE≤5.1°). Excluding hip flexion/extension moments (RMSE = 1.04 Nm/kg), equivalence was also supported for time varying joint moments between laboratories (RMSE≤0.40 Nm/kg). Dependent variables typically used to characterise UnSS were also equivalent. When consistent experimental and modelling procedures are employed, consistent time varying UnSS lower limb joint kinematic and moment estimates between laboratories can be obtained. We therefore interpret these results as a support of equivalence, yet highlight the challenges of establishing between-laboratory experiments or data sharing, as well as establishing appropriate ranges of acceptable uncertainty. These findings are important for data sharing and multi-centre trials.
    Matched MeSH terms: Weight-Bearing
  2. Pahlevanzadeh F, Bakhsheshi-Rad HR, Kharaziha M, Kasiri-Asgarani M, Omidi M, Razzaghi M, et al.
    J Mech Behav Biomed Mater, 2021 04;116:104320.
    PMID: 33571842 DOI: 10.1016/j.jmbbm.2021.104320
    Polymethyl methacrylate (PMMA) bone cements (BCs) have some drawbacks, including limited bioactivity and bone formation, as well as inferior mechanical properties, which may result in failure of the BC. To deal with the mentioned issues, novel bioactive polymethyl methacrylate-hardystonite (PMMA-HT) bone cement (BC) reinforced with 0.25 and 0.5 wt% of carbon nanotube (CNT) and reduced graphene oxide (rGO) was synthesized. In this context, the obtained bone cements were evaluated in terms of their mechanical and biological characteristics. The rGO reinforced bone cement exhibited better mechanical properties to the extent that the addition of 0.5 wt% of rGO where its compressive and tensile strength of bioactive PMMA-HT/rGO cement escalated from 92.07 ± 0.72 MPa, and 40.02 ± 0.71 MPa to 187.48 ± 5.79 MPa and 64.92 ± 0.75 MPa, respectively. Besides, the mechanisms of toughening, apatite formation, and cell interaction in CNT and rGO encapsulated PMMA have been studied. Results showed that the existence of CNT and rGO in BCs led to increase of MG63 osteoblast viability, and proliferation. However, rGO reinforced bone cement was more successful in supporting MG63 cell attachment compared to the CNT counterpart due to its wrinkled surface, which made a suitable substrate for cell adhesion. Based on the results, PMMA-HT/rGO can be a proper bone cement for the fixation of load-bearing implants.
    Matched MeSH terms: Weight-Bearing
  3. Lee WC, Chua T
    Malays Orthop J, 2021 Mar;15(1):138-140.
    PMID: 33880163 DOI: 10.5704/MOJ.2103.023
    Atypical femoral fractures (AFF) have low union rates. The use of teriparatide has been advocated for the post-operative healing of AFF, but the evidence is limited to case reports and some series due to its low incidence. We present a case series of four female patients to support the use of teriparatide after the surgical fixation of their AFF. Three of the patients had a complete AFF and one had an incomplete fracture. Their mean age was 70 (52 - 87) years, mean body mass index 24.6 (18.3 - 29.3), mean bone mineral density T-score of -2.3 (-4.8/-1.0), with a prior history of anti-resorptive therapy with bisphosphonates and denosumab. Teriparatide was started at an average of 8 (2-18) days post-fixation, with 20mcg daily for six months. Immediate full weight-bearing was permitted in three patients, while one was non-weight bearing for two months. The mean time to union was 12 (10 - 14) weeks. No side effects were observed over a mean follow-up of 58 (50 - 72) weeks. The use of teriparatide facilitated the quick union of AFF after surgical fixation. It appeared to be safe and promoted fracture healing in AFF.
    Matched MeSH terms: Weight-Bearing
  4. Shahedan NF, Abdullah MMAB, Mahmed N, Kusbiantoro A, Tammas-Williams S, Li LY, et al.
    Materials (Basel), 2021 Feb 08;14(4).
    PMID: 33567696 DOI: 10.3390/ma14040809
    This paper details analytical research results into a novel geopolymer concrete embedded with glass bubble as its thermal insulating material, fly ash as its precursor material, and a combination of sodium hydroxide (NaOH) and sodium silicate (Na2SiO3) as its alkaline activator to form a geopolymer system. The workability, density, compressive strength (per curing days), and water absorption of the sample loaded at 10% glass bubble (loading level determined to satisfy the minimum strength requirement of a load-bearing structure) were 70 mm, 2165 kg/m3, 52.58 MPa (28 days), 54.92 MPa (60 days), and 65.25 MPa (90 days), and 3.73 %, respectively. The thermal conductivity for geopolymer concrete decreased from 1.47 to 1.19 W/mK, while the thermal diffusivity decreased from 1.88 to 1.02 mm2/s due to increased specific heat from 0.96 to 1.73 MJ/m3K. The improved physicomechanical and thermal (insulating) properties resulting from embedding a glass bubble as an insulating material into geopolymer concrete resulted in a viable composite for use in the construction industry.
    Matched MeSH terms: Weight-Bearing
  5. Baharum NN, Ariffin F, Hanafiah M, Sulaiman SH
    Korean J Fam Med, 2021 Jan;42(1):84-87.
    PMID: 32447880 DOI: 10.4082/kjfm.19.0021
    Avascular necrosis, or osteonecrosis of the femoral head, is a debilitating condition which leads to the destruction of the hip joint due to an interruption in the blood supply to the bony region and is most commonly due to trauma. The case discussed here has been highlighted as it presented as non-traumatic osteonecrosis of the femoral head with an absence of risk factors in a healthy adult male. A 37-year-old male presented with a 4-month history of recurrent left hip pain, which worsened with initiation of movement and weightbearing on the affected side. The patient was overweight but normotensive with a full range of movement of the hips bilaterally. There were no abnormalities detected on initial X-ray images of the left hip. However, due to the persistent pain and sclerotic changes in a subsequent X-ray, a magnetic resonance image of the bilateral hips was obtained, leading to the diagnosis of osteonecrosis of the bilateral femoral heads. Due to the lack of improvement with physiotherapy and analgesia, the patient was subjected to conservative surgery of the symptomatic left hip with concurring evidence of avascular necrosis based on intraoperative anatomical biopsy. This case emphasizes the importance of identifying underlying issues during history taking and physical examination in adults without risk factors. The early diagnosis of osteonecrosis assists in preventing joint collapse and can delay the requirement of joint replacements. High levels of suspicion are necessary to instigate investigation in persistent cases without the presence of risk factors.
    Matched MeSH terms: Weight-Bearing
  6. Mutafi A, Yidris N, Koloor SSR, Petrů M
    Materials (Basel), 2020 Nov 26;13(23).
    PMID: 33256257 DOI: 10.3390/ma13235378
    Stainless steels are increasingly used in construction today, especially in harsh environments, in which steel corrosion commonly occurs. Cold-formed stainless steel structures are currently increasing in popularity because of its efficiency in load-bearing capacity and its appealing architectural appearance. Cold-rolling and press-braking are the cold-working processes used in the forming of stainless steel sections. Press braking can produce large cross-sections from thin to thick-walled sections compared to cold-rolling. Cold-forming in press-braked sections significantly affect member behaviour and joints; therefore, they have attained great attention from many researchers to initiate investigations on those effects. This paper examines the behaviour of residual stress distribution of stainless steel press-braked sections by implementing three-dimensional finite element (3D-FE) technique. The study proposed a full finite element procedure to predict the residual stresses starting from coiling-uncoiling to press-braking. This work considered material anisotropy to examine its effect on the residual stress distribution. The technique adopted was compared with different finite element techniques in the literature. This study also provided a parametric study for three corner radius-to-thickness ratios looking at the through-thickness residual stress distribution of four stainless steels (i.e., ferritic, austenitic, duplex, lean duplex) in which have their own chemical composition. In conclusion, the comparison showed that the adopted technique provides a detailed prediction of residual stress distribution. The influence of geometrical aspects is more pronounced than the material properties. Neglecting the material anisotropy shows higher shifting in the neutral axis. The parametric study showed that all stainless steel types have the same stress through-thickness distribution. Moreover, R/t ratios' effect is insignificant in all transverse residual stress distributions, but a slight change to R/t ratios can affect the longitudinal residual stress distribution.
    Matched MeSH terms: Weight-Bearing
  7. Amran M, Fediuk R, Vatin N, Lee YH, Murali G, Ozbakkaloglu T, et al.
    Materials (Basel), 2020 Sep 28;13(19).
    PMID: 32998362 DOI: 10.3390/ma13194323
    Foamed concrete (FC) is a high-quality building material with densities from 300 to 1850 kg/m3, which can have potential use in civil engineering, both as insulation from heat and sound, and for load-bearing structures. However, due to the nature of the cement material and its high porosity, FC is very weak in withstanding tensile loads; therefore, it often cracks in a plastic state, during shrinkage while drying, and also in a solid state. This paper is the first comprehensive review of the use of man-made and natural fibres to produce fibre-reinforced foamed concrete (FRFC). For this purpose, various foaming agents, fibres and other components that can serve as a basis for FRFC are reviewed and discussed in detail. Several factors have been found to affect the mechanical properties of FRFC, namely: fresh and hardened densities, particle size distribution, percentage of pozzolanic material used and volume of chemical foam agent. It was found that the rheological properties of the FRFC mix are influenced by the properties of both fibres and foam; therefore, it is necessary to apply an additional dosage of a foam agent to enhance the adhesion and cohesion between the foam agent and the cementitious filler in comparison with materials without fibres. Various types of fibres allow the reduction of by autogenous shrinkage a factor of 1.2-1.8 and drying shrinkage by a factor of 1.3-1.8. Incorporation of fibres leads to only a slight increase in the compressive strength of foamed concrete; however, it can significantly improve the flexural strength (up to 4 times), tensile strength (up to 3 times) and impact strength (up to 6 times). At the same time, the addition of fibres leads to practically no change in the heat and sound insulation characteristics of foamed concrete and this is basically depended on the type of fibres used such as Nylon and aramid fibres. Thus, FRFC having the presented set of properties has applications in various areas of construction, both in the construction of load-bearing and enclosing structures.
    Matched MeSH terms: Weight-Bearing
  8. Jusoh H, Sabariah Binti Abd Manan T, Beddu S, Osman SBS, Jusoh MNH, Mohtar WHMW, et al.
    Data Brief, 2020 Aug;31:105868.
    PMID: 32637485 DOI: 10.1016/j.dib.2020.105868
    Soil requires load bearing impact assessment for stability. Therefore, this study aims to utilize the multi-channel analysis surface wave (MASW) for soil subsurface investigation and profiling around Peninsular Malaysia. The standard penetration test (SPT) was conducted for comparison between factual N-value and computed N-value from shear wave velocity (Vs ) obtained from MASW using the Imai and Tonouchi equation. The correlation coefficient (R) and coefficient of determination, (R2 ), showed strong relationship between factual N-value and computed N-value. The model of Vs and factual N-value data distribution is non-normal but the analyzed relationship shows a significant level of p-value < 0.05. The R2 for each location of Vs -N-value relationship are ranging from 0.5 to 0.9.
    Matched MeSH terms: Weight-Bearing
  9. Soraganvi P, Nagakiran KV, Raghavendra-Raju RP, Anilkumar D, Wooly S, Basti BD, et al.
    Malays Orthop J, 2019 Nov;13(3):8-14.
    PMID: 31890104 DOI: 10.5704/MOJ.1911.002
    Introduction: Plantar fasciitis is characterised by pain in the heel, which is aggravated on weight bearing after prolonged rest. Many modalities of treatment are commonly used in the management of plantar fasciitis including steroid injection. Many studies show that steroid injection provides pain relief in the short term but not long lasting. Recent reports show autologous platelet-rich plasma (PRP) injection promotes healing, resulting in better pain relief in the short as well as long term. The present study was undertaken to compare the effects of local injection of platelet-rich plasma and Corticosteroid in the treatment of chronic plantar fasciitis. Materials and methods: Patients with the clinical diagnosis of chronic plantar fasciitis (heel pain of more than six weeks) after failed conservative treatment and plantar fascia thickness more than 4mm were included in the study. Patients with previous surgery for plantar fasciitis, active bilateral plantar fasciitis, vascular insufficiency or neuropathy related to heel pain, hypothyroidism and diabetes mellitus were excluded from the study. In this prospective double-blind study, 60 patients who fulfilled the criteria were divided randomly into two groups. Patients in Group A received PRP injection and those in Group B received steroid injection. Patients were assessed with visual analog scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) score. Assessment was done before injection, at six weeks, three months and six months follow-up after injection. Plantar fascia thickness was assessed before the intervention and six months after treatment using sonography. Results: Mean VAS in Group A decreased from 7.14 before injection to 1.41 after injection and in Group B decreased from 7.21 before injection to 1.93 after injection, at final follow-up. Mean AOFAS score in Group A improved from 54 to 90.03 and in Group B from 55.63 to 74.67 at six months' follow-up. The improvements observed in VAS and AOFAS were statistically significant. At the end of six months' follow-up, plantar fascia thickness had reduced in both groups (5.78mm to 3.35mm in Group A and 5.6 to 3.75 in Group B) and the difference was statistically significant. Conclusion: Local injection of platelet-rich plasma is an effective treatment option for chronic plantar fasciitis when compared with steroid injection with long lasting beneficial effect.
    Matched MeSH terms: Weight-Bearing
  10. Yapp JH, Raja Ahmad RMK, Mahmud R, Mohtarrudin N, Mohamad Yusof L, Abdul Rahim E, et al.
    Wound Repair Regen, 2019 05;27(3):225-234.
    PMID: 30667138 DOI: 10.1111/wrr.12698
    Frequent repositioning is important to prevent pressure ulcer (PU) development, by relieving pressure and recovering damages on skin areas induced by repetitive loading. Although repositioning is the gold standard to prevent PU, there is currently no strategy for determining tissue condition under preventive approaches. In this study, the peak reactive hyperemia (RH) trends and ultrasonographic (US) features are compared with the tissue condition under histopathological examination to determine the potential use of these features in determining the tissue condition noninvasively. Twenty-one male Sprague-Dawley rats (seven per group), with body weight of 385-485 g, were categorized into three groups and subjected to different recovery times, each with three repetitive loading cycles at skin tissues above of right trochanter area. The first, second, and third groups were subjected to short (3 minutes), moderate (10 minutes), and prolonged (40 minutes) recovery, respectively, while applying fixed loading time and pressure (10 minutes and 50 mmHg, respectively), to provide different degree of recovery and tissue conditions (tissue damage and tissue recovery). Peak RH was measured in the three cycles to determine RH trend (increasing, decreasing, and inconsistent). All rat tissues were evaluated using ultrasound at pre- and post-experiment and rated by two raters to categorize the severity of tissue changes (no, mild, moderate, and severe). The tissue condition was also evaluated using histopathological examination to distinguish between normal and abnormal tissues. Most of the samples with increasing RH trend is related to abnormal tissue (71%); while inconsistent RH trends is more related to normal tissue (82%). There is no relationship between the tissue conditions evaluated under ultrasonographic and histopathological examination. Peak RH trend over repetitive loading may serve as a new feature for determining the tissue condition that leading to pressure ulcer.
    Matched MeSH terms: Weight-Bearing*
  11. Fahad S, Habib AA, Awais MB, Umer M, Rashid HU
    Malays Orthop J, 2019 Mar;13(1):36-41.
    PMID: 31001382 DOI: 10.5704/MOJ.1903.006
    Introduction: Tibia is the most common long bone fractured due its vulnerable subcutaneous location and most often associated with acquired complications of delayed union or non-union due to infection. Amongst the various treatment options to treat them, the Ilizarov external fixator application is considered superior due to its multiple advantages. The objective of this study was to analyse the role of Ilizarov fixation in infected tibial non-union, as well as to assess bony union and associated functional outcomes. Materials and Methods: A retrospective review was conducted for the duration between 1st January 2005 to 31st December 2016. Total of fifty-one patients with tibial non-union associated with infection who treated with the Ilizarov fixator were included in the study. Patient records were reviewed for union of bone, bone and functional outcomes and complications. Results: The most common organism for infection was identified to be Staphylococcus Aureus. At the time of final follow-up all patients had achieved union except two, one of whom had to undergo amputation due to non-union and sepsis. Majority of the patients had an excellent score as per ASAMI grading system for bone and function results. The most common complication noted was pin track infections. Conclusion: In our experience, Ilizarov external fixator is better suited for infected non-union of tibia because it can provide a stable mechanical environment, bone transport, correct deformities, and enable weight bearing and hence we recommend its use for the same.
    Matched MeSH terms: Weight-Bearing
  12. Hasan O, Fahad S, Sattar S, Umer M, Rashid H
    Malays Orthop J, 2018 Nov;12(3):24-30.
    PMID: 30555643 DOI: 10.5704/MOJ.1811.006
    Introduction: Ankle arthrodesis using the Ilizarov technique provides high union rate with the added benefits of early weight-bearing, and the unique advantage of its ability to promote regeneration of soft tissue around the bone, including skin, muscle and neuro-vascular structures, and its versatility to allow correction of the position of the foot by adjusting the frame post-operatively as needed. We describe our experience with this technique and the functional outcomes in our patients. Materials and Methods: This retrospective study was conducted in 20 ankle fusion cases using the Ilizarov method between the years 2007 and 2017. We defined success in treatment by loss of preoperative symptoms and radiological union on plain radiographs of the ankle. Results: Fusion was achieved in all patients (100%). Immediate post-operative ambulation was with full weight bearing (FWB) in 16 (83%) of the participants and non-weight bearing (NWB) in 3 patients (17%). Post-procedure 11 patients (67%) of the participants who were full weight bearing required some form of support for walking for 2-3 weeks. Post-operatively three patients had pin tract infection requiring intravenous antibiotics. Radiological union took range of 6-12 weeks, mean union time was 8 weeks. Only one patient required bone grafting due to bone loss. Average follow-up period was 10-45 months. Conclusion: The Ilizarov technique has a high union rate and leads to general favourable clinical outcome and may be considered for any ankle arthrodesis but is especially useful in complex cases such as for revisions, soft-tissue compromise, infection and in patients with risk for non-union. Early weight bearing is an extra benefit.
    Matched MeSH terms: Weight-Bearing
  13. Choudhari P, Padia D
    Malays Orthop J, 2018 Nov;12(3):38-42.
    PMID: 30555645 DOI: 10.5704/MOJ.1811.008
    Introduction: Plating in distal tibia fractures are associated with higher rate of soft tissue complications. As adequate soft tissue cover is available over anterolateral surface of the tibia, use of anterolateral plate fixation in distal tibia fractures has increased. The purpose of our research is to evaluate the outcomes of anterolateral locking plate fixation in distal tibia fractures using ORIF. Materials and Methods: A retrospective analysis of 25 patients, who had distal tibia fractures and underwent open reduction and anterolateral plating. Bone and soft tissue healing and complications encountered were analysed. Result: Full weight bearing was allowed at an average of 5.4 months (range: 3-12 months) after seeing radiological union. We have observed superficial wound infection in four cases. Two cases had marginal necrosis, two cases had sensory disturbance over dorsolateral aspect of foot and two cases had delayed non-union. Mean length of surgical incision was 9cm (range: 5-12 cm). Conclusion: Open reduction internal fixation of distal tibia fractures with anterolateral plating is a reliable way of fracture fixation and stabilisation with proper surgical technique and aseptic precautions.
    Matched MeSH terms: Weight-Bearing
  14. Mutafi A, Yidris N, Ishak MR, Zahari R
    Heliyon, 2018 Nov;4(11):e00937.
    PMID: 30839801 DOI: 10.1016/j.heliyon.2018.e00937
    Steel sections are normally shaped via cold work manufacturing processes. The extent of cold work to shape the steel sections might induce residual stresses in the region of bending. Previously, researchers had performed studies on the influences of local buckling on the failure behavior of steel compression members which shown that failure will happen when most of the yielding has extended to the middle surface in the bend region of the sections. Therefore, these cold work methods may have major effect on the behavior of the steel section and also its load-bearing capability. In addition, another factor may play significant role in formed section's load-bearing capacity which is the longitudinal residual strain. The longitudinal residual strain raised during forming procedure can be used to define the section imperfection of the formed section and its relation to the existence of defects. Therefore, the main motivation of this research paper is to perform three-dimensional finite element (3D-FE) to investigate peak longitudinal residual strains of a thin-walled steel plate with large bending angle along member length. A 3D finite element simulation in ABAQUS has been employed to simulate this forming process. The study concluded that the longitudinal residual strain at the section corner edge was higher than those at the rest of the corner region. These strains at the edge were higher than the yield strain


    (



    ε


    y



    )


    of the formed section which occurred due to the lack of transverse restraint. This made the plate edge tended to bend toward the normal direction when it was under a high transverse bending. This causes a significant difference in longitudinal strain at the plate edge.
    Matched MeSH terms: Weight-Bearing
  15. Shanmugam R, Jian CYCCS, Haseeb A, Aik S
    J Orthop Surg (Hong Kong), 2018 10 3;26(3):2309499018802511.
    PMID: 30270746 DOI: 10.1177/2309499018802511
    PURPOSE: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion.

    METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.

    RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.

    CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.

    Matched MeSH terms: Weight-Bearing
  16. Samuel S, Ahmad RE, Ramasamy TS, Manan F, Kamarul T
    Injury, 2018 Apr;49(4):775-783.
    PMID: 29503013 DOI: 10.1016/j.injury.2018.02.020
    BACKGROUND: It has been previously suggested that the use of regenerative promoters, which include bone marrow-derived mesenchymal stem cells (MSCs) or natural growth factors supplement such as platelet-rich concentrate (PRC) could promote cartilage regeneration. However, the notion that the concurrent use of both promoters may provide a synergistic effect that improves the repair outcome of focal cartilage injury has not been previously demonstrated. This study was thus conducted to determine whether the concomitant use of PRC could further enhance the reparative potential of MSCs encapsulated in alginate transplanted into focal cartilage injury in rabbits.

    METHODS: Artifically created full thickness cartilage defects were made on the weight-bearing region of medial femoral condyles in bilateral knees of New Zealand White rabbits (N = 30). After one month, the right knee was treated with either i) PRC (n = 10), ii) MSCs (n = 10), or, iii) a combination of PRC and MSCs (PRC + MSC) (n = 10), all encapsulated in alginate. The left knee remained untreated (control). Rabbits were sacrificed at 3 and 6 months after treatment. Cartilage tissue regeneration was accessed using ICRS morphologic scoring, histologic grading by O'Driscoll scoring, immunohistochemical staining and quantitative analysis of glycosaminoglycans (GAG) per total protein content.

    RESULTS: At 3 months, transplantation using PRC alone was equally effective as MSCs in inducing the repair of cartilage defects. However, PRC + MSC resulted in significantly higher ICRS and O'Driscoll scores (p 

    Matched MeSH terms: Weight-Bearing
  17. Mahmood SK, Zakaria MZAB, Razak ISBA, Yusof LM, Jaji AZ, Tijani I, et al.
    Biochem Biophys Rep, 2017 Jul;10:237-251.
    PMID: 28955752 DOI: 10.1016/j.bbrep.2017.04.008
    The demands for applicable tissue-engineered scaffolds that can be used to repair load-bearing segmental bone defects (SBDs) is vital and in increasing demand. In this study, seven different combinations of 3 dimensional (3D) novel nanocomposite porous structured scaffolds were fabricated to rebuild SBDs using an extraordinary blend of cockle shells (CaCo3) nanoparticles (CCN), gelatin, dextran and dextrin to structure an ideal bone scaffold with adequate degradation rate using the Freeze Drying Method (FDM) and labeled as 5211, 5400, 6211, 6300, 7101, 7200 and 8100. The micron sized cockle shells powder obtained (75 µm) was made into nanoparticles using mechano-chemical, top-down method of nanoparticles synthesis with the presence of the surfactant BS-12 (dodecyl dimethyl bataine). The phase purity and crystallographic structures, the chemical functionality and the thermal characterization of the scaffolds' powder were recognized using X-Ray Diffractometer (XRD), Fourier transform infrared (FTIR) spectrophotometer and Differential Scanning Calorimetry (DSC) respectively. Characterizations of the scaffolds were assessed by Scanning Electron Microscopy (SEM), Degradation Manner, Water Absorption Test, Swelling Test, Mechanical Test and Porosity Test. Top-down method produced cockle shell nanoparticles having averagely range 37.8±3-55.2±9 nm in size, which were determined using Transmission Electron Microscope (TEM). A mainly aragonite form of calcium carbonate was identified in both XRD and FTIR for all scaffolds, while the melting (Tm) and transition (Tg) temperatures were identified using DSC with the range of Tm 62.4-75.5 °C and of Tg 230.6-232.5 °C. The newly prepared scaffolds were with the following characteristics: (i) good biocompatibility and biodegradability, (ii) appropriate surface chemistry and (iii) highly porous, with interconnected pore network. Engineering analyses showed that scaffold 5211 possessed 3D interconnected homogenous porous structure with a porosity of about 49%, pore sizes ranging from 8.97 to 337 µm, mechanical strength 20.3 MPa, Young's Modulus 271±63 MPa and enzymatic degradation rate 22.7 within 14 days.
    Matched MeSH terms: Weight-Bearing
  18. Wahab AH, Kadir MR, Harun MN, Kamarul T, Syahrom A
    Med Biol Eng Comput, 2017 Mar;55(3):439-447.
    PMID: 27255451 DOI: 10.1007/s11517-016-1525-6
    The present study was conducted to compare the stability of four commercially available implants by investigating the focal stress distributions and relative micromotion using finite element analysis. Variations in the numbers of pegs between the implant designs were tested. A load of 750 N was applied at three different glenoid positions (SA: superior-anterior; SP: superior-posterior; C: central) to mimic off-center and central loadings during activities of daily living. Focal stress distributions and relative micromotion were measured using Marc Mentat software. The results demonstrated that by increasing the number of pegs from two to five, the total focal stress volumes exceeding 5 MPa, reflecting the stress critical volume (SCV) as the threshold for occurrence of cement microfractures, decreased from 8.41 to 5.21 % in the SA position and from 9.59 to 6.69 % in the SP position. However, in the C position, this change in peg number increased the SCV from 1.37 to 5.86 %. Meanwhile, micromotion appeared to remain within 19-25 µm irrespective of the number of pegs used. In conclusion, four-peg glenoid implants provide the best configuration because they had lower SCV values compared with lesser-peg implants, preserved more bone stock, and reduced PMMA cement usage compared with five-peg implants.
    Matched MeSH terms: Weight-Bearing
  19. Park KS, Chan CK, Lee GW, Ahn HW, Yoon TR
    Injury, 2017 Feb;48(2):388-393.
    PMID: 27914663 DOI: 10.1016/j.injury.2016.11.029
    INTRODUCTION: Anatomical reduction of displaced acetabular fracture is not without its' limitations and complications. This study is conducted to assess clinical and radiological outcomes as well as complications of treating displaced acetabular fractures with emphasis on anatomical reduction in weight-bearing area, mainly the posterior column, and imperfect reduction of the anterior column is acceptable. However, stability of both columns is mandatory.

    METHODS: It was a retrospective study carried out in a Level 1 arthroplasty and trauma centre. 23 patients (17 males, 6 females) with average age of 50.1 years (range, 36-68 years) with displaced acetabular fracture treated with combined incisions and plate-cable systems were included. There were 3 elementary and 18 associated fractures according to Letournel classification. Average follow-up was 23.5 months (range, 12-38.7 months). Mean operation time was 160min (range: 75-320min). Functional scores were evaluated using Harris Hip Score (HHS) whilst reduction was assessed by Matta criteria. Any displacement of reduction, osteoarthritis, heterotopic ossification, and other complications was recorded.

    RESULT: 65.2% (15/23) of the patients obtained excellent HHS and 21.7% (5/23) had good HHS. There were 12 anatomical, 6 imperfect, and 5 poor reductions. No displacement was recorded in final follow-up. Complications documented: three lateral femoral cutaneous nerve injuries, two conversions to total hip arthroplasty, three Brooker stage 1 heterotrophic ossification, one pulmonary embolism and one screw irritation. No incidence of wound breakdown, infection and radiological osteoarthritis was reported.

    CONCLUSIONS: Imperfect reduction of the anterior column provided clinical outcomes that are as good as total anatomical reduction. This approach minimizes soft tissue damage and reduces perioperative morbidities.

    Matched MeSH terms: Weight-Bearing
  20. Mehrali M, Thakur A, Pennisi CP, Talebian S, Arpanaei A, Nikkhah M, et al.
    Adv Mater, 2017 Feb;29(8).
    PMID: 27966826 DOI: 10.1002/adma.201603612
    Given their highly porous nature and excellent water retention, hydrogel-based biomaterials can mimic critical properties of the native cellular environment. However, their potential to emulate the electromechanical milieu of native tissues or conform well with the curved topology of human organs needs to be further explored to address a broad range of physiological demands of the body. In this regard, the incorporation of nanomaterials within hydrogels has shown great promise, as a simple one-step approach, to generate multifunctional scaffolds with previously unattainable biological, mechanical, and electrical properties. Here, recent advances in the fabrication and application of nanocomposite hydrogels in tissue engineering applications are described, with specific attention toward skeletal and electroactive tissues, such as cardiac, nerve, bone, cartilage, and skeletal muscle. Additionally, some potential uses of nanoreinforced hydrogels within the emerging disciplines of cyborganics, bionics, and soft biorobotics are highlighted.
    Matched MeSH terms: Weight-Bearing
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links