  1. Nik Zainuddin NAM, Abd Razak NA, Ab Karim MS
    Proc Inst Mech Eng H, 2023 Jun;237(6):741-748.
    PMID: 37131337 DOI: 10.1177/09544119231171787
    Composite materials used in the prosthetic and orthotic fields have helped improve the fabrication of sockets. Laminated sockets proved to be stronger than conventional thermoplastic sockets. The internal surface of a laminated socket plays an important role in patient comfort and is influenced by the material used to fabricate the socket. This study analyzes the internal surface profile of five different materials, that is, Dacron felt, fiberglass, Perlon stockinette, polyester stockinette, and elastic stockinette. All sockets were fabricated using an acrylic resin mix with hardener powder at a ratio of 100:3. The internal surface of the sockets was tested using the Mitutoyo SurfTest SJ-210 series for 20 trials. The overall Ra values were 2.318, 2.380, 2.682, 2.722, and 3.750 µm for fiberglass, polyester, Perlon, elastic stockinette, and Dacron felt. Dacron felt yielded the lowest Ra value, thus, producing the smoothest internal surface but requiring high skill and the correct technique during the fabrication of a laminated socket. Fiberglass is considered the best material for the internal surface despite not producing the lowest value individually but overall is the lowest and most consistent, indicating that it is easy to use to laminate prosthetic sockets.
    Matched MeSH terms: Artificial Limbs*
  2. Pirouzi G, Abu Osman NA, Oshkour AA, Ali S, Gholizadeh H, Abas WA
    Sensors (Basel), 2014;14(9):16754-65.
    PMID: 25207872 DOI: 10.3390/s140916754
    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
    Matched MeSH terms: Artificial Limbs*
  3. Arifin N, Abu Osman NA, Ali S, Gholizadeh H, Abas WA
    ScientificWorldJournal, 2014;2014:856279.
    PMID: 25003155 DOI: 10.1155/2014/856279
    This study aimed to evaluate the effects of prosthetic foot types on the postural stability among transtibial amputees when standing on different support surfaces.
    Matched MeSH terms: Artificial Limbs*
  4. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Abas WA
    Am J Phys Med Rehabil, 2015 Jan;94(1):1-10.
    PMID: 24919079 DOI: 10.1097/PHM.0000000000000134
    This study aimed to compare the effects of different suspension methods on the interface stress inside the prosthetic sockets of transtibial amputees when negotiating ramps and stairs.
    Matched MeSH terms: Artificial Limbs*
  5. Eshraghi A, Osman NA, Gholizadeh H, Ahmadian J, Rahmati B, Abas WA
    Sci Rep, 2013;3:2270.
    PMID: 23881340 DOI: 10.1038/srep02270
    Individuals with lower limb amputation need a secure suspension system for their prosthetic devices. A new coupling system was developed that is capable of suspending the prosthesis. The system's safety is ensured through an acoustic alarm system. This article explains how the system works and provides an in vivo evaluation of the device with regard to pistoning during walking. The system was designed to be used with silicone liners and is based on the requirements of prosthetic suspension systems. Mechanical testing was performed using a universal testing machine. The pistoning during walking was measured using a motion analysis system. The new coupling device produced significantly less pistoning compared to a common suspension system (pin/lock). The safety alarm system would buzz if the suspension was going to fail. The new coupling system could securely suspend the prostheses in transtibial amputees and produced less vertical movement than the pin/lock system.
    Matched MeSH terms: Artificial Limbs*
  6. Ramlee MH, Ammarullah MI, Mohd Sukri NS, Faidzul Hassan NS, Baharuddin MH, Abdul Kadir MR
    Sci Rep, 2024 Mar 21;14(1):6842.
    PMID: 38514731 DOI: 10.1038/s41598-024-57454-8
    Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young's modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.
    Matched MeSH terms: Artificial Limbs*
  7. El-Sayed AM, Hamzaid NA, Abu Osman NA
    Sensors (Basel), 2014;14(12):23724-41.
    PMID: 25513823 DOI: 10.3390/s141223724
    Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0-100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types.
    Matched MeSH terms: Artificial Limbs*
  8. Al-Fakih E, Arifin N, Pirouzi G, Mahamd Adikan FR, Shasmin HN, Abu Osman NA
    J Biomed Opt, 2017 Aug;22(8):1-8.
    PMID: 28822140 DOI: 10.1117/1.JBO.22.8.087001
    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.
    Matched MeSH terms: Artificial Limbs*
  9. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Artificial Limbs*
  10. Jamayet NB, Kirangi JK, Husein A, Alam MK
    Eur J Dent, 2017 4 25;11(1):130-134.
    PMID: 28435380 DOI: 10.4103/1305-7456.202636
    Enucleation and evisceration are the most common surgical procedures that are performed to manage tumor, trauma, and infection. Given the consequences of surgical intervention, the conditions of the remaining eye socket may affect future prosthetic rehabilitation. A custom-made ocular prosthesis can be used to help restore the esthetics and functional defects and to improve the quality of life of patients with such conditions. An assessment must be performed on the prosthetic outcome before rehabilitation. The etiology of defect, type of surgery, condition of the remaining socket, and patient's age should all be considered. This report discusses three different etiological eye defects that have undergone enucleation and evisceration and describes the factors that have a significant role in the esthetic and functional outcome of the prosthesis. This report should serve as a helpful aid for maxillofacial prosthodontists to understand the primary objective of rehabilitating each eye defect and to meet patient expectations.
    Matched MeSH terms: Artificial Limbs
  11. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    PLoS One, 2014;9(5):e94520.
    PMID: 24827560 DOI: 10.1371/journal.pone.0094520
    The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance.
    Matched MeSH terms: Artificial Limbs/psychology*
  12. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Artificial Limbs*
  13. Eshraghi A, Osman NA, Gholizadeh H, Karimi M, Ali S
    Prosthet Orthot Int, 2012 Mar;36(1):15-24.
    PMID: 22269941 DOI: 10.1177/0309364611431625
    One of the main indicators of the suspension system efficiency in lower limb prostheses is vertical displacement or pistoning within the socket. Decreasing pistoning and introducing an effective system for evaluating pistoning could contribute to the amputees' rehabilitation process.
    Matched MeSH terms: Artificial Limbs*
  14. Gholizadeh H, Osman NA, Kamyab M, Eshraghi A, Abas WA, Azam MN
    Clin Biomech (Bristol, Avon), 2012 Jan;27(1):34-9.
    PMID: 21794965 DOI: 10.1016/j.clinbiomech.2011.07.004
    The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and liner. Since the effects of these new liners on suspension are unclear, the objective of this study was to compare the pistoning effect of Seal-In(®) X5 and Dermo(®) Liner by using Vicon Motion System.
    Matched MeSH terms: Artificial Limbs*
  15. Mohd Hawari N, Jawaid M, Md Tahir P, Azmeer RA
    Disabil Rehabil Assist Technol, 2017 Nov;12(8):868-874.
    PMID: 28068847 DOI: 10.1080/17483107.2016.1269209
    The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.
    Study site: Cheras Rehabilitation Hospital in Kuala Lumpur, Perkeso Rehab Center in Melaka, Pusat Latihan dan Perindustrian Bangi and Rumah Insaniah Tun Dr Siti Hasmah Ptaling Jaya in Selangor, Malaysia
    Matched MeSH terms: Artificial Limbs*
  16. Cameron JAP
    Med J Malaya, 1950;5.
    1. The importance of the mental and physical reactions of the amputee. 2. Ideal sites and the technique of amputations are discussed briefly. 3. Rehabilitation and training of the amputee is important if the best results are to be obtained. 4. Some of the special reasons for amputation are considered. 5. The component parts of an artificial limb and their alignment are outlined. 6. Special features in fitting limbs for women and children. 7. Some complications resulting from the wearing of an artificial limb are described. 8. Limb fitting in Malaya has its own peculiar difficulties which time and experience will rectify.
    Matched MeSH terms: Artificial Limbs
  17. Karim HHA, Chern PM
    Med J Malaysia, 2020 09;75(5):519-524.
    PMID: 32918420
    INTRODUCTION: Increasing numbers of limb amputation are performed globally and in Malaysia due to the rise of complications because of Diabetes Mellitus (DM). Limb amputation influences many aspects of an individual's life, and prosthesis restoration is one of the primary rehabilitation goals to help amputees resume daily activities. As limited information is available in Malaysia, this study aims to determine the socio-demographic, clinical characteristics and prosthesis usage among the amputees.

    METHODS: A cross-sectional study using self-developed survey form was conducted at 13 Medical Rehabilitation Clinics in Malaysia among 541 upper and lower limb amputees of any duration and cause.

    RESULTS: The study population had a mean age of 54 years. Majority were males, Malays, married and had completed secondary school. About 70% of amputations were performed due to DM complications and at transtibial level. Fifty-eight percent of unilateral lower limb amputees were using prosthesis with a mean (standard deviation) of 6.48 (±4.55) hours per day. Time since amputation was the true factor associated with prosthesis usage. Longer hours of prosthesis use per day was positively correlated with longer interval after prosthesis restoration (r=0.467).

    CONCLUSION: Higher aetiology of DM and lower prosthesis usage among amputees may be because of high prevalence of DM in Malaysia. The prosthesis usage and hours of use per day were low compared to the international reports, which may be influenced by sampling location and time since amputation. Nevertheless, this is a novel multicentre study on the characteristics and prosthesis usage of amputees. Hopefully, this research will assist to support, facilitate and promote prosthesis rehabilitation in Malaysia.

    Matched MeSH terms: Artificial Limbs*
  18. Gholizadeh H, Abu Osman NA, Eshraghi A, Arifin N, Chung TY
    Prosthet Orthot Int, 2016 Aug;40(4):509-16.
    PMID: 25583929 DOI: 10.1177/0309364614564022
    BACKGROUND: This article describes a total surface bearing prosthetic socket for a patient (25-year-old female) with a bulbous stump.

    CASE DESCRIPTION AND METHODS: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure.

    FINDINGS AND OUTCOMES: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier.

    CONCLUSION: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait.

    CLINICAL RELEVANCE: Proper socket design and suspension system based on the amputees' need can facilitate rehabilitation process and lead to the amputee's satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.

    Matched MeSH terms: Artificial Limbs*
  19. Bhuiyan MS, Choudhury IA, Dahari M
    Biol Cybern, 2015 Apr;109(2):141-62.
    PMID: 25491411 DOI: 10.1007/s00422-014-0635-1
    Development of an advanced control system for prostheses (artificial limbs) is necessary to provide functionality, effectiveness, and preferably the feeling of a sound living limb. The development of the control system has introduced varieties of control strategies depending on the application. This paper reviews some control systems used for prosthetics, orthotics, and exoskeletons. The advantages and limitations of different control systems for particular applications have been discussed and presented in a comparative manner to help in deciding the appropriate method for pertinent application.
    Matched MeSH terms: Artificial Limbs*
  20. Gholizadeh H, Lemaire ED, Eshraghi A
    Clin Biomech (Bristol, Avon), 2016 08;37:108-116.
    PMID: 27423025 DOI: 10.1016/j.clinbiomech.2016.06.005
    BACKGROUND: An optimal suspension system can improve comfort and quality of life in people with limb loss. To guide practice on prosthetic vacuum suspension systems, assessment of the current evidence and professional opinion are required.

    METHODS: PubMed, Web of Science, and Google Scholar databases were explored to find related articles. Search terms were amputees, artificial limb, prosthetic suspension, prosthetic liner, vacuum, and prosthesis. The results were refined by vacuum socket or vacuum assisted suspension or sub-atmospheric suspension. Study design, research instrument, sample size, and outcome measures were reviewed. An online questionnaire was also designed and distributed worldwide among professionals and prosthetists (www.ispoint.org, OANDP-L, LinkedIn, personal email).

    FINDINGS: 26 articles were published from 2001 to March 2016. The number of participants averaged 7 (SD=4) for transtibial and 6 (SD=6) for transfemoral amputees. Most studies evaluated the short-term effects of vacuum systems by measuring stump volume changes, gait parameters, pistoning, interface pressures, satisfaction, balance, and wound healing. 155 professionals replied to the questionnaire and supported results from the literature. Elevated vacuum systems may have some advantages over the other suspension systems, but may not be appropriate for all people with limb loss.

    INTERPRETATION: Elevated vacuum suspension could improve comfort and quality of life for people with limb loss. However, future investigations with larger sample sizes are needed to provide strong statistical conclusions and to evaluate long-term effects of these systems.