Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Muhammed Elamin S, Muhamad Arshad NF, Md Redzuan A, Abdul Aziz SA, Hong J, Chua XY, et al.
    BMJ Open, 2024 Apr 02;14(4):e079606.
    PMID: 38569693 DOI: 10.1136/bmjopen-2023-079606
    OBJECTIVE: The objective of this study is to explore the information needs related to insulin therapy in children and adolescents with type 1 diabetes mellitus (T1DM) from the children's perspectives as well as their caregivers.

    DESIGN: Qualitative study; semistructured interviews. To identify emerging themes relating to information needs, open coding and thematic analysis were employed.

    SETTING: Participants were recruited from a tertiary care children's hospital in Kuala Lumpur, Malaysia and a specialist hospital in Riyadh, Saudi Arabia.

    PARTICIPANTS: Thirty one children with a mean age of 11.5 years (SD=1.9) and their caregivers were interviewed. Seventeen participants were from Malaysia and 14 were from Saudi Arabia.

    RESULTS: Four themes of information emerged from the interviews, including information related to (1) hypoglycaemia and hyperglycaemia, (2) insulin therapy, (3) injection technique and (4) other information needs pertaining to continuous glucose monitoring, access to peer groups and future advances in insulin therapy.

    CONCLUSION: This study provided valuable insights into the information needs related to T1DM and insulin therapy among children and adolescents with T1DM that should be considered by stakeholders in the development of age-appropriate education materials. Such materials will assist children and adolescents to better manage their life-long T1DM condition from adolescence until adulthood.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  2. Ng SM, Malene IV, Nguyen TK, Le K, Lim YXL, Lek N, et al.
    BMC Endocr Disord, 2023 Nov 16;23(1):249.
    PMID: 37974071 DOI: 10.1186/s12902-023-01501-4
    BACKGROUND: There is minimal data of health outcomes for Type 1 Diabetes (T1D) in Southeast Asia (SEA) where government funding of insulin and blood glucose monitoring either do not exist or is limited. The full impact of Covid-19 pandemic on the national economies of SEA remain unknown. In the midst of the pandemic, in 2021, HelloType1 was developed by Action4Diabetes (A4D), a non-government organisation charity in collaboration with Southeast Asia local healthcare professionals as an innovative digital educational resource platform of T1D in local languages. HelloType1 was launched in Cambodia, Vietnam, Thailand and Malaysia in 2021 to 2022 with Memorandums of Understandings (MOUs) signed between A4D and each country. Internet data analytics were undertaken between the 1st of January 2022 to 31st of December 2022.

    AIMS: The aims of this study were to explore the usability and internet data analytics of the HelloType1 online educational platform within each country.

    METHODS: The data analytics were extracted Google analytics that tracks data from the website hellotype1.com and Facebook analytics associated with the website.

    RESULTS: There was a 147% increase in the number of HelloType1 users between the first 6 months versus the latter 6 months in 2022 and a 15% increase in the number of pages visited were noted. The majority of traffic source were coming from organic searches with a significant increase of 80% growth in 2022.

    CONCLUSIONS: The results of the analytics provide important insights on how an innovative diabetes digital educational resource in local languages may be optimally delivered in low-middle income countries with limited resources.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  3. Kong APS, Lim S, Yoo SH, Ji L, Chen L, Bao Y, et al.
    Diabetes Res Clin Pract, 2023 Jul;201:110718.
    PMID: 37196707 DOI: 10.1016/j.diabres.2023.110718
    Glucose monitoring has evolved from self-monitoring of blood glucose to glycated hemoglobin, and the latest continuous glucose monitoring (CGM). A key challenge to adoption of CGM for management of diabetes in Asia is the lack of regional CGM recommendations. Hence, thirteen diabetes-specialists from eight Asia-Pacific (APAC) countries/regions convened to formulate evidence-based, APAC-specific CGM recommendations for individuals with diabetes. We defined CGM metrics/targets and developed 13 guiding-statements on use of CGM in: (1) people with diabetes on intensive insulin therapy, and (2) people with type 2 diabetes on basal insulin with/without glucose lowering drugs. Continual use of CGM is recommended in individuals with diabetes on intensive insulin therapy and suboptimal glycemic control, or at high risk of problematic hypoglycemia. Continual/intermittent CGM may also be considered in individuals with type 2 diabetes on basal insulin regimen and with suboptimal glycemic control. In this paper, we provided guidance for optimizing CGM in special populations/situations, including elderly, pregnancy, Ramadan-fasting, newly diagnosed type 1 diabetes, and comorbid renal disease. Statements on remote CGM, and stepwise interpretation of CGM data were also developed. Two Delphi surveys were conducted to rate the agreement on statements. The current APAC-specific CGM recommendations provide useful guidance for optimizing use of CGM in the region.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  4. Elancheziyan M, Prakasham K, Eswaran M, Duraisamy M, Ganesan S, Lee SL, et al.
    Environ Res, 2023 Apr 15;223:115403.
    PMID: 36754108 DOI: 10.1016/j.envres.2023.115403
    The design and development of eco-friendly fabrication of cost-effective electrochemical nonenzymatic biosensors with enhanced sensitivity and selectivity are one of the emerging area in nanomaterial and analytical chemistry. In this aspect, we developed a facile fabrication of tertiary nanocomposite material based on cobalt and polymelamine/nitrogen-doped graphitic porous carbon nanohybrid composite (Co-PM-NDGPC/SPE) for the application as a nonenzymatic electrochemical sensor to quantify glucose in human blood samples. Co-PM-NDGPC/SPE nanocomposite electrode fabrication was achieved using a single-step electrodeposition method under cyclic voltammetry (CV) technique under 1 M NH4Cl solution at 20 constitutive CV cycles (sweep rate 20 mV/s). Notably, the fabricated nonenzymatic electroactive nanocomposite material exhibited excellent electrocatalytic sensing towards the quantification of glucose in 0.1 M NaOH over a wide concentration range from 0.03 to 1.071 mM with a sensitive limit of detection 7.8 μM. Moreover, the Co-PM-NDGPC nanocomposite electrode with low charge transfer resistance (Rct∼81 Ω) and high ionic diffusion indicates excellent stability, reproducibility, and high sensitivity. The fabricated nanocomposite materials exhibit a commendable sensing response toward glucose molecules present in the blood serum samples recommends its usage in real-time applications.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  5. Teoh ST, Hussain S, Hong JYH
    J ASEAN Fed Endocr Soc, 2022;37(2):49-59.
    PMID: 36578892 DOI: 10.15605/jafes.037.02.08
    OBJECTIVES: This study described and compared glycaemic changes with the use of the following Continuous Glucose Monitoring (CGM) metrics: time in range, time in hyperglycaemia and time in hypoglycaemia from retrospective CGM data among children and adolescents with Type 1 Diabetes Mellitus (T1DM), before and during Ramadan to better understand the impact of fasting during this season.

    METHODOLOGY: This study was conducted in 2 tertiary centres: Hospital Putrajaya (HPJ) and Hospital Universiti Sains Malaysia (HUSM) from February to May 2020. Muslim T1DM patients between ages 8 to18 who intended to fast during Ramadan were given Ramadan-focused education. CGM iPro2® (Medtronic) was used before and during Ramadan, complemented by finger-prick glucose monitoring or self-monitoring of blood glucose (SMBG).

    RESULTS: Of the 32 patients, only 24 (12 female) were analysed. Mean age was 13.6 ± 3.1 years old, mean HbAlc was 9.6 ± 1.9% and mean duration of illness was 5.4 ± 3.4 years. Majority (91.7%) were on multiple dose injections (MDI) while only 8.3% were on continuous subcutaneous insulin infusion (CSII). All fasted in Ramadan without acute complications. Retrospective CGM analysis revealed similar results in time in range (TIR), time in hyperglycaemia and time in hypoglycaemia before and during Ramadan, indicating no increased hypoglycaemic or hyperglycaemic events related to fasting. Glycaemic variability before Ramadan as measured by the LBGI, HBGI and MAG, were similar to values during Ramadan.

    CONCLUSION: Ramadan fasting among T1DM children and adolescents, by itself, is not associated with short-term glycaemic deterioration. T1DM youths can fast safely in Ramadan with the provision of focused education and regular SMBG.

    Matched MeSH terms: Blood Glucose Self-Monitoring/methods
  6. Yunos MFAM, Manczak R, Guines C, Mansor AFM, Mak WC, Khan S, et al.
    Biosensors (Basel), 2021 Dec 03;11(12).
    PMID: 34940251 DOI: 10.3390/bios11120494
    Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg·dL-1 and its LOD was calculated to be 29.89 mg/dL.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  7. Rama Chandran S, A Vigersky R, Thomas A, Lim LL, Ratnasingam J, Tan A, et al.
    Diabetes Technol Ther, 2020 02;22(2):103-111.
    PMID: 31502876 DOI: 10.1089/dia.2019.0277
    Background:
    Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined with long-term complications. We compare the components of CGP and PGR across type 1 and type 2 diabetes.
    Methods:
    Participants: n = 60 type 1 and n = 100 type 2 who underwent continuous glucose monitoring (CGM). Mean glucose, coefficient of variation (%CV), intensity of hypoglycemia (INThypo), intensity of hyperglycemia (INThyper), time out-of-range (TOR <3.9 and >10 mmol/L), and PGR were calculated. PGR (median, interquartile ranges [IQR]) for diabetes types, and HbA1c classes were compared.
    Results:
    While HbA1c was lower in type 1 (type 1 vs. type 2: 8.0 ± 1.6 vs. 8.6 ± 1.7, P = 0.02), CGM-derived mean glucoses were similar across both groups (P > 0.05). TOR, %CV, INThypo, and INThyper were all higher in type 1 [type 1 vs. type 2: 665 (500, 863) vs. 535 (284, 823) min/day; 39% (33, 46) vs. 29% (24, 34); 905 (205, 2951) vs. 18 (0, 349) mg/dL × min2; 42,906 (23,482, 82,120) vs. 30,166 (10,276, 57,183) mg/dL × min2, respectively, all P 
    Matched MeSH terms: Blood Glucose Self-Monitoring
  8. Deeb A, Elbarbary N, Smart CE, Beshyah SA, Habeb A, Kalra S, et al.
    Pediatr Diabetes, 2020 02;21(1):5-17.
    PMID: 31659852 DOI: 10.1111/pedi.12920
    Matched MeSH terms: Blood Glucose Self-Monitoring
  9. Lee JY, Chan CKY, Chua SS, Ng CJ, Paraidathathu T, Lee KKC, et al.
    J Gen Intern Med, 2020 Jan;35(1):87-94.
    PMID: 31512187 DOI: 10.1007/s11606-019-05316-9
    BACKGROUND: Connected devices that allow people with diabetes to monitor their blood glucose levels remotely with data visualization have been shown to improve self-care behavior in diabetes management. However, their effectiveness and usability for a low-middle-income, racially diverse population are unknown.

    OBJECTIVE: This study aims to evaluate the effects of remote telemonitoring with team-based management on people with uncontrolled type 2 diabetes.

    DESIGN: This was a pragmatic 52-week cluster-randomized controlled study among 11 primary care government practices in Malaysia.

    PARTICIPANTS: People with type 2 diabetes aged 18 and above, who had hemoglobin A1c ≥ 7.5% but less than 11.0% within the past 3 months and resided in the state of Selangor.

    INTERVENTION: The intervention group received home gluco-telemonitors and transmitted glucose data to a care team who could adjust therapy accordingly. The team also facilitated self-management by supporting participants to improve medication adherence, and encourage healthier lifestyle and use of resources to reduce risk factors. Usual care group received routine healthcare service.

    MAIN MEASURE: The primary outcome was the change in HbA1c at 24 weeks and 52 weeks. Secondary outcomes included change in fasting plasma glucose, blood pressure, lipid levels, health-related quality of life, and diabetes self-efficacy.

    RESULTS: A total of 240 participants were recruited in this study. The telemonitoring group reported larger improvements in glycemic control compared with control at the end of study (week 24, - 0.05%; 95% CI - 0.10 to 0.00%) and at follow-up (week 52, - 0.03%; - 0.07 to 0.02%, p = 0.226). Similarly, no differences in other secondary outcomes were observed, including the number of adverse events and health-related quality of life.

    CONCLUSION: This study indicates that there is limited benefit of replacing telemedicine with the current practice of self-monitoring of blood glucose. Further innovative methods to improve patient engagement in diabetes care are needed.

    TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02466880.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  10. Aneesa Abdul Rashid, Navin Kumar Devaraj, Zuhra Hamzah, Tan Chai Eng
    MyJurnal
    Introduction: Diabetic control depends partially on self-management. Diabetes self-care is reported to be a strong predictor of glycemic control in Type 2 Diabetes Mellitus (T2DM) patients. Factors contributing to better self-care include self-efficacy and social support. We aim to determine effects of these factors on glucose control in T2DM patients in a primary care clinic. Methods: This study utilised data from a bigger study looking into factors affecting social support and self-efficacy and their correlation in T2DM patients. This study was done among 329 T2DM pa- tients attending a primary care clinic in Selangor, Malaysia between November 2013- January 2014. Systematic ran- dom sampling was used. Instruments used were the MOS Social Support Survey and the Diabetic Management Self Efficacy Scale (DMSES). Patients’ socio-demographic data and glucose monitoring records were obtained. The asso- ciation between social support and self-efficacy with blood glucose control was determined using logistic regression. Results: The mean age of the respondents is 54.6 (+11.2), mostly female (55.3%) and Malay ethnicity (63.5%). Being older and retired were predictors for good glucose control (OR=1.05,p=0.01 and OR=2.2,p=0.023) respectively. There is also significant correlations between number of close friends/relatives with social support and self-efficacy (r=0.162,p=0.030 and r=0.190,p=0.01) respectively. The correlation of social support and self-efficacy with HbA1c levels are r= -0.044(p=0.426) and r= -0.08(p= 0.744) respectively. Conclusion: There were no correlations between social support and self-efficacy with the level of HbA1c among patients with T2DM in this study. We found older aged and retired patients to have better HbA1c levels.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  11. Bukhsh A, Goh BH, Zimbudzi E, Lo C, Zoungas S, Chan KG, et al.
    PMID: 33329377 DOI: 10.3389/fendo.2020.534873
    Objective: This study aimed to qualitatively explore perspectives, practices, and barriers to self-care practices (eating habits, physical activity, self-monitoring of blood glucose, and medicine intake behavior) in urban Pakistani adults with type 2 diabetes mellitus (T2DM). Methods: Pakistani adults with T2DM were recruited from the outpatient departments of two hospitals in Lahore. Semistructured interviews were conducted and audiorecorded until thematic saturation was reached. Two researchers thematically analyzed the data independently using NVivo® software with differences resolved by a third researcher. Results: Thirty-two Pakistani adults (aged 35-75 years, 62% female) participated in the study. Six themes were identified from qualitative analysis: role of family and friends, role of doctors and healthcare, patients' understanding about diabetes, complication of diabetes and other comorbidities, burden of self care, and life circumstances. A variable experience was observed with education and healthcare. Counseling by healthcare providers, family support, and fear of diabetes-associated complications are the key enablers that encourage study participants to adhere to diabetes-related self-care practices. Major barriers to self care are financial constraints, physical limitations, extreme weather conditions, social gatherings, loving food, forgetfulness, needle phobia, and a hectic job. Conclusion: Respondents identified many barriers to diabetes self care, particularly related to life situations and diabetes knowledge. Family support and education by healthcare providers were key influencers to self-care practices among Pakistani people with diabetes.
    Matched MeSH terms: Blood Glucose Self-Monitoring/psychology*
  12. Khan AHKY, Zakaria NF, Abidin MAZ, Lim CTS, Kamaruddin NA
    J ASEAN Fed Endocr Soc, 2020;35(1):68-76.
    PMID: 33442172 DOI: 10.15605/jafes.035.01.12
    Introduction: Chronic and post-prandial hyperglycemia are independent risk factors for diabetic complications. Glycemic patterns among hemodialysis end-stage-renal-disease (ESRD) differ as glucose metabolism changes with declining kidney function with more pronounced glycemic fluctuations. The objectives of this study are to determine glycemic patterns on hemodialysis days, the magnitude of post-hemodialysis rebound hyperglycemia (PHH) and their associated factors.

    Methodology: 148 patients on hemodialysis were analysed, 91 patients had end-stage-diabetic-renal disease (DM-ESRD), and 57 patients had end-stage-non-diabetic renal disease (NDM-ESRD). Glycemic patterns and PHH data were obtained from 11-point and 7-point self-monitoring blood glucose (SMBG) profiles on hemodialysis and non-hemodialysis days. PHH and its associated factors were analysed with logistic regression.

    Results: Mean blood glucose on hemodialysis days was 9.33 [SD 2.7] mmol/L in DM-ESRD patients compared to 6.07 [SD 0.85] mmol/L in those with NDM-ESRD (p<0.001). PHH occurred in 70% of patients and was more pronounced in DM-ESRD compared to NDM-ESRD patients (72.5% vs 27.5%; OR 4.5). Asymptomatic hypoglycemia was observed in 18% of patients. DM-ESRD, older age, previous IHD, obesity, high HbA1c, elevated highly-sensitive CRP and low albumin were associated with PHH.

    Conclusion: DM-ESRD patients experienced significant PHH in our cohort. Other associated factors include older age, previous IHD, obesity, high HbA1c, elevated hs-CRP and low albumin.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  13. Yee YC, Hashim R, Mohd Yahya AR, Bustami Y
    Sensors (Basel), 2019 May 31;19(11).
    PMID: 31159318 DOI: 10.3390/s19112511
    Glucose oxidase (EC 1.1.3.4) sensors that have been developed and widely used for glucose monitoring have generally relied on electrochemical principle. In this study, the potential use of colorimetric method for glucose detection utilizing glucose oxidase-magnetic cellulose nanocrystals (CNCs) is explored. Magnetic cellulose nanocrystals (magnetic CNCs) were fabricated using iron oxide nanoparticles (IONPs) and cellulose nanocrystals (CNCs) via electrostatic self-assembly technique. Glucose oxidase was successfully immobilized on magnetic CNCs using carbodiimide-coupling reaction. About 33% of GOx was successfully attached on magnetic CNCs, and the affinity of GOx-magnetic CNCs to glucose molecules was slightly higher than free enzymes. Furthermore, immobilization does not affect the specificity of GOx-magnetic CNCs towards glucose and can detect glucose from 0.25 mM to 2.5 mM. Apart from that, GOx-magnetic CNCs stored at 4 °C for 4 weeks retained 70% of its initial activity and can be recycled for at least ten consecutive cycles.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  14. Ng D, Noor NM, Yong SL
    J ASEAN Fed Endocr Soc, 2019;34(1):29-35.
    PMID: 33442134 DOI: 10.15605/jafes.034.01.06
    Objectives: To determine the prevalence of hypoglycaemia using continuous glucose monitoring system (CGMS) among insulin-treated pregnant women with diabetes whose glycosylated haemoglobin (HbA1c) were <6.0% and identify the risk factors associated with hypoglycaemia occurrence.

    Methodology: We conducted a cross-sectional study using 6-days CGMS to detect the prevalence of hypoglycaemia in 31 insulin-treated pregnant women with diabetes who achieved HbA1c <6.0%. Patients were required to log-keep their self-monitoring blood glucose (SMBG) readings and hypoglycaemia events.

    Results: Eight women experienced confirmed hypoglycaemia with additional seven experienced relative hypoglycaemia, giving rise to prevalence rate of 45.2% (one had both confirmed and relative hypoglycaemia). Nine relative hypoglycaemia and 17 confirmed hypoglycaemic events were recorded. Sixteen (94%) out of 17 confirmed hypoglycaemia events recorded by CGMS were asymptomatic and were missed despite performing regular SMBG. Nocturnal hypoglycaemia events were recorded in seven women. Univariable analysis did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Conclusion: Insulin-treated pregnant women with diabetes who achieved HbA1c <6.0% were associated with high prevalence of hypoglycaemia. Asymptomatic hypoglycaemia is common in our cohort and frequently missed despite regular SMBG. Present study did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  15. Kalra S, Czupryniak L, Kilov G, Lamptey R, Kumar A, Unnikrishnan AG, et al.
    Diabetes Ther, 2018 Dec;9(6):2185-2199.
    PMID: 30390228 DOI: 10.1007/s13300-018-0521-2
    Premixed insulins are an important tool for glycemic control in persons with diabetes. Equally important in diabetes care is the selection of the most appropriate insulin regimen for a particular individual at a specific time. Currently, the choice of insulin regimens for initiation or intensification of therapy is a subjective decision. In this article, we share insights, which will help in rational and objective selection of premixed formulations for initiation and intensification of insulin therapy. The glycemic status and its variations in a person help to identify the most appropriate insulin regimen and formulation for him or her. The evolution of objective glucometric indices has enabled better glycemic monitoring of individuals with diabetes. Management of diabetes has evolved from a 'glucocentric' approach to a 'patient-centered' approach; patient characteristics, needs, and preferences should be evaluated when considering premixed insulin for treatment of diabetes.Funding: Novo Nordisk, India.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  16. Paramasivam SS, Chinna K, Singh AKK, Ratnasingam J, Ibrahim L, Lim LL, et al.
    Diabet Med, 2018 08;35(8):1118-1129.
    PMID: 29663517 DOI: 10.1111/dme.13649
    AIMS: To determine if therapeutic, retrospective continuous glucose monitoring (CGM) improves HbA1c with less hypoglycaemia in women with insulin-treated gestational diabetes mellitus (GDM).

    METHODS: This prospective, randomized controlled, open-label trial evaluated 50 women with insulin-treated GDM randomized to either retrospective CGM (6-day sensor) at 28, 32 and 36 weeks' gestation (Group 1, CGM, n = 25) or usual antenatal care without CGM (Group 2, control, n = 25). All women performed seven-point capillary blood glucose (CBG) profiles at least 3 days per week and recorded hypoglycaemic events (symptomatic and asymptomatic CBG

    Matched MeSH terms: Blood Glucose Self-Monitoring/instrumentation; Blood Glucose Self-Monitoring/methods
  17. Rama Chandran S, Tay WL, Lye WK, Lim LL, Ratnasingam J, Tan ATB, et al.
    Diabetes Technol Ther, 2018 05;20(5):353-362.
    PMID: 29688755 DOI: 10.1089/dia.2017.0388
    BACKGROUND: Hypoglycemia is the major impediment to therapy intensification in diabetes. Although higher individualized HbA1c targets are perceived to reduce the risk of hypoglycemia in those at risk of hypoglycemia, HbA1c itself is a poor predictor of hypoglycemia. We assessed the use of glycemic variability (GV) and glycemic indices as independent predictors of hypoglycemia.

    METHODS: A retrospective observational study of 60 type 1 and 100 type 2 diabetes subjects. All underwent professional continuous glucose monitoring (CGM) for 3-6 days and recorded self-monitored blood glucose (SMBG). Indices were calculated from both CGM and SMBG. Statistical analyses included regression and area under receiver operator curve (AUC) analyses.

    RESULTS: Hypoglycemia frequency (53.3% vs. 24%, P Blood Glucose Index (LBGI)CGM, Glycemic Risk Assessment Diabetes Equation (GRADE)HypoglycemiaCGM, and Hypoglycemia IndexCGM predicted hypoglycemia well. %CVCGM and %CVSMBG consistently remained a robust discriminator of hypoglycemia in type 1 diabetes (AUC 0.88). In type 2 diabetes, a combination of HbA1c and %CVSMBG or LBGISMBG could help discriminate hypoglycemia.

    CONCLUSION: Assessment of glycemia should go beyond HbA1c and incorporate measures of GV and glycemic indices. %CVSMBG in type 1 diabetes and LBGISMBG or a combination of HbA1c and %CVSMBG in type 2 diabetes discriminated hypoglycemia well. In defining hypoglycemia risk using GV and glycemic indices, diabetes subtypes and data source (CGM vs. SMBG) must be considered.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  18. Scott EM, Bilous RW, Kautzky-Willer A
    Diabetes Technol Ther, 2018 03;20(3):180-188.
    PMID: 29470094 DOI: 10.1089/dia.2017.0386
    BACKGROUND: Accuracy of the FreeStyle Libre™ Flash Glucose Monitoring System has not been evaluated in pregnant women with diabetes. The aim of this study was to determine accuracy (compared to self-monitoring of blood glucose [SMBG]), clinical safety, and acceptability of the FreeStyle Libre System when used at home by this population.

    MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).

    RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.

    CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.

    Matched MeSH terms: Blood Glucose Self-Monitoring/adverse effects*
  19. Tamrin, K.F., Adilah, A.N., Hamdi, M.M., Jong, R.P.
    MyJurnal
    A glucose meter (or glucometer) is a medical device for determining the approximate concentration of glucose in the
    blood by pricking a finger to draw blood sample using a sharp needle. However, diabetic patient has quite slow level in
    wound healing process which causes their fingers constantly in a state of wounded and exposed to bacteria. More
    importantly, two main factors for the weakness of invasive technique is a painful process and cost often because constant
    monitoring of glucose level is very expensive. The main objective of this research is to design and develop a non-invasive
    optical measuring technique to measure body glucose level automatically and painlessly using a laser pointer and a
    smartphone. Images captured by the smartphone is analysed using a Matlab software to determine the refractive index of
    the urine sample. Calibration of the system is performed by correlating the results with that of the glucometer. Both
    results compare well with R-squared value of 92.9%. The system can be potentially used for remote health and patient
    monitoring.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  20. Bukhsh A, Lee SWH, Pusparajah P, Schmitt A, Khan TM
    Health Qual Life Outcomes, 2017 Oct 12;15(1):200.
    PMID: 29025432 DOI: 10.1186/s12955-017-0776-8
    BACKGROUND: Numerous study tools on diabetes self-care have been introduced; however, most existing tools do not show expectable and meaningful correlations with patients' glycaemic control. The Diabetes Self-Management Questionnaire (DSMQ) was designed to appraise self-care activities which can predict glycaemic control outcomes. However, this tool has not been validated in Pakistan. Therefore, the aim of this study was to translate and examine the psychometric properties of the Urdu version of DSMQ among type 2 diabetes patients.

    METHOD: Standard forward-backward translation was used to translate the DSMQ into Urdu language. A convenience sample of 130 patients with type 2 diabetes was collected to assess the Urdu version's psychometric properties. Reliability was assessed by Cronbach's coefficient α and validity was assessed using confirmatory factor analysis and criterion-related correlations.

    RESULTS: High internal consistency was found for all DSMQ scales (Sum scale: α = 0.96, Glucose Management: 0.91; Dietary Control: 0.88; Physical Activity: 0.89; Health-Care Use: 0.73). The DSMQ subscales showed significant correlations with HbA1c (Glucose Management: -0.75; Dietary Control: -0.76; Physical Activity: -0.71; Health-Care Use: -0.64; Sum Scale: -0.78; all p  0.05). Adequate fit to the data was achieved for single factor model after successively modelling all significant correlations between the items' error terms, with Chi2 = 106.6, df = 84, p = 0.049; TLI = 0.98, CFI = 0.99 and RMSEA = 0.05 (90% CI 0.01-0.07). Whereas a comparatively lower fit indices to data were observed in case of four factor model.

    CONCLUSION: The findings support the Urdu version of the DSMQ as a reliable and valid instrument for assessing self-care activities associated with glycaemic control in type 2 diabetes patients.
    Matched MeSH terms: Blood Glucose Self-Monitoring/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links