Displaying publications 1 - 20 of 349 in total

Abstract:
Sort:
  1. Lim KB
    Ann Acad Med Singap, 1988 Oct;17(4):545-7.
    PMID: 3223741
    Forty-five Asian patients (Indians 35, Chinese 8, Malay 2) with histologically proven lichen planus were studied by immunofluorescence. The most characteristic feature, seen in 93% of the cases, was shaggy deposition of fibrinogen along the basement membrane. Immunoglobulin deposition along the basement membrane was notably, absent. Colloid bodies were observed in 87% of the cases. Fibrinogen was the most common immunoreactant, and its presence in colloid bodies was always associated with fibrinogen deposition along the basement membrane zone. Colloid bodies also contained a variety of other immunoreactants. However, staining for IgM was noted to be the most intense. The combination of shaggy deposition of fibrinogen along the basement membrane, in the absence of immunoglobulins, and the presence of colloid bodies around the basement membrane zone, is highly characteristic of lichen planus. The pattern of immunofluorescence among Asians with lichen planus, conforms to that observed in other races. There did not appear to be any difference in the immunofluorescence staining with pattern in the three racial groups studied.
    Matched MeSH terms: Microscopy, Fluorescence
  2. Peh SC, Looi LM, Wang F, Chua CT, Tan HW, Lam KL
    Malays J Pathol, 1990 Jun;12(1):21-6.
    PMID: 2090886
    In the 10-year period from October 1977 to July 1987, 149 cases of primary IgA nephropathy were histologically confirmed through renal biopsies in the Department of Pathology, University Hospital, Kuala Lumpur. The ages of these patients ranged from 5 to 72 years, with the majority in the 20-30 year age group. There was no sex preponderance. The ethnic distribution showed a significant predominance of Chinese with 107 (71.8%) Chinese, 24 (16.1%) Malays, 15 (10.1%) Indians and 3 others. A wide range of renal glomerular pathology was seen, the commonest being diffuse mesangioproliferative glomerulonephritis (59.1%). Focal proliferative glomerulonephritis (14.1%) followed by minimal change glomerulonephritis (10.7%) were next in order of frequency. Immunofluorescence studies consistently demonstrated heavy and predominant IgA deposition in the mesangium. Weak deposition of C3, IgG and IgM were also observed in various combinations.
    Matched MeSH terms: Microscopy, Fluorescence
  3. Cheong SK, Lim YC, Mok KL
    Malays J Pathol, 1991 Jun;13(1):51-2.
    PMID: 1795563
    Mixed reagents for the Glucose-6-phosphate dehydrogenase (G6PD) deficiency fluorescent screening test were freeze-dried in plastic tubes. The reagents were then reconstituted with distilled water and the test was performed in the usual way. Initial testing with the freeze-dried mixed reagents gave consistent positive reaction to 12 normal blood samples and negative reaction to 9 G6PD deficient blood samples. This will enable a laboratory with freeze-drying facilities to prepare reagent tubes in bulk. As these tubes can be kept at 4 degrees C and do not require to be stored at -20 degrees C, a major laboratory can prepare these tubes and supply small laboratories for screening purposes.
    Matched MeSH terms: Fluorescence
  4. Abdullah AR, Tahir NM, Wei LK
    Bull Environ Contam Toxicol, 1994 Oct;53(4):618-26.
    PMID: 8000192
    Matched MeSH terms: Spectrometry, Fluorescence
  5. Jayaraman SD, Ismail S, Nair NK, Navaratnam V
    J Chromatogr B Biomed Sci Appl, 1997 Mar 07;690(1-2):253-7.
    PMID: 9106050
    A method is described for the determination of pyronaridine in plasma using high-performance liquid chromatography with fluorescence detection. The method involves liquid-liquid extraction with phosphate buffer (pH 6.0, 0.05 M) and diethyl ether-hexane (70:30%, v/v) and chromatographic separation on a C18 column (Nucleosil, 250 x 4.6 mm I.D., 5 microns particle size) with acetonitrile-0.05 M phosphate buffer pH 6.0 (60:40%, v/v) as the mobile phase (1 ml/min) and detection by fluorescence (lambda ex = 267 nm, lambda em = 443 nm). The detector response is linear up to 1000 ng and the overall recoveries of pyronaridine and quinine were 90.0 and 60.3%, respectively. The assay procedure was adequately sensitive to measure 10 ng/ml pyronaridine in plasma samples with acceptable precision (< 15% C.V.). The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Spectrometry, Fluorescence
  6. Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1997 May 23;693(1):241-4.
    PMID: 9200543
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of acyclovir in human plasma. The method entailed direct injection of the plasma sample after deproteination. It is both specific and sensitive with a detection limit of 30 ng/ml at a signal-to-noise ratio of 3:1, and is thus suitable for use in pharmacokinetic studies of acyclovir. The method had a mean absolute recovery of 96%, while the within-day and between-day coefficients of variation and percentages error were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Spectrometry, Fluorescence
  7. Yuen KH, Peh KK
    J Chromatogr B Biomed Sci Appl, 1998 Sep 18;715(2):436-40.
    PMID: 9792531
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5-8000 ng/ml.
    Matched MeSH terms: Spectrometry, Fluorescence
  8. Norazizah S, AbuBakar S
    JUMMEC, 1999;4:41-46.
    Dengue 2 New Guinea C (NGC) virus NS3 protein, a potentially important virulence factor was cloned to the N-terminus of the Aeqirorea victoria enhanced green fluorescent protein (EGFP) using the pEGFP-N1 mammalian expression vector. During amplification of the recombinant plasmid in E. coli, transformants expressing the EGFP were detected in vivo when viewed using fluorescence microscopy. This inadvertent expression of the recombinant fusion protein was confirmed further by detection of the T7.Tag peptide cloned to the aluino terminal of the fusion protein using T 7.Tag specific monoclonal antibody. These findings represent perhaps the first reported expression of the T7.Tag-NS3-EGFP fusion protein using the pEGFP-N1 mammalian expression vector in E. coli. KEYWORDS: Dengue, NS3, pEGFP-N1, fusion protein.
    Matched MeSH terms: Fluorescence
  9. Xu ZQ, Norris KJ, Weinberg DS, Kardatzke J, Wertz P, Frank P, et al.
    J Chromatogr B Biomed Sci Appl, 2000 Jun 09;742(2):267-75.
    PMID: 10901131
    A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (+/-)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C(18) cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).
    Matched MeSH terms: Spectrometry, Fluorescence
  10. Faridah MN, Shahrom AW
    Malays J Pathol, 2001 Dec;23(2):111-4.
    PMID: 12166591
    This paper describes a modified method of quantitative determination of histamine in human skin wounds using fluorescence spectrophotometer. In this study, histamine was used as an indicator to differentiate antemortem from postmortem wounds. Skin samples were obtained from 20 corpses which were brought to Hospital Kuala Lumpur and Universiti Kebangsaan Malaysia for medicolegal autopsy. Sections of human skin were processed biochemically for histamine determination using fluorescence spectrophotometer. Results revealed no significant difference in the histamine content of the antemortem wounds in comparison to postmortem wounds. Based on these results, detection of histamine is not suitable to differentiate antemortem from postmortem wounds.
    Matched MeSH terms: Spectrometry, Fluorescence
  11. Moh MH, Tang TS, Tan GH
    J Chromatogr Sci, 2001 Dec;39(12):508-12.
    PMID: 11767238
    A simple and sensitive high-performance liquid chromatographic method for the determination of Therminol 66 thermal heating fluid in glycerin and fatty acids is developed. Sample solutions dissolved in methanol-tetrahydrofuran (50:50, v/v) are injected directly into a reversed-phase C18 column and eluted with a methanol and water mixture (88:12, v/v). The concentration of the thermal heating fluid is monitored by fluorescence detection at 257 nm (excitation) and 320 nm (emission). The calibration graph obtained from various concentrations of the thermal heating fluid in the methanol and tetrahydrofuran mixture is linear (correlation coefficient = 0.999), and the limit of detection is 0.01 microg/mL. Spiked glycerin containing 0.1 to 1.0 microg/g of the thermal heating fluid also gives good linearity with a mean recovery of 95.3%. The mean intra- and interassay precision are 1.80-6.51% and 5.71-9.03%, respectively, at the 0.1-microg/g level. The method is simple and does not require any pretreatment step, thus it is ideal for quality assurance purposes.
    Matched MeSH terms: Fluorescence
  12. Chowdhury SM, Omar AR, Aini I, Hair-Bejo M, Jamaluddin AA, Kono Y, et al.
    J. Biochem. Mol. Biol. Biophys., 2002 Aug;6(4):249-55.
    PMID: 12186740
    A study was conducted to isolate and identify chicken anaemia virus (CAV) from field samples of clinically infected broiler chickens in Malaysia. A total of 125 samples were collected from chickens aged 2-6 weeks with clinically depressed and retarded growth, of which five samples were found positive to CAV directly by polymerase chain reaction (PCR). Later, five isolates of CAV from the respective five PCR positive samples were isolated in MDCC-MSB1 cells at passage 4 based on cytopathic effects, PCR and indirect immunofluorescent antibody test. The isolates were identified as BL-1, BL-2, BL-3, BL-4 and BL-5. These CAV isolates were found to resist treatment with chloroform and heat at 37 degrees C for 2 h, 56 degrees C for 30 min and 70 degrees C for 5 min. One of the isolates, BL-5 produced significant reduction (p < 0.001) of hematocrit values (9-19%), pale bone marrow, thymus atrophy and haemorrhages in skin/muscle when inoculated into 1-day old SPF chickens. Restriction enzyme digestion of 926 bp genomic fragments of all the isolates including Cux-1 isolate with HindIII exhibited a similar pattern of bands in 2% agarose gel. The present findings confirmed the presence of CAV in Malaysia.
    Matched MeSH terms: Microscopy, Fluorescence
  13. Ahmad UK, Ulang Z, Yusop Z, Fong TL
    Water Sci Technol, 2002;46(9):117-25.
    PMID: 12448460
    The complex nature of natural organic matter (NOM), and the impact of this matter on drinking water quality have necessitated the characterization studies of NOM. A fluorescence technique for the characterization of NOM in Malaysian river water is reported. Water samples from several river sampling sites were collected and concentrated using a low-pressure reverse osmosis (LPROM). Solid phase extraction (SPE) using C18 extraction cartridges were used to fractionate the water samples into humic and non-humic fractions. To differentiate and classify various types of humic substances, fluorescence was applied in emission, excitation and in synchronous-scan modes. A synchronous spectral profile was found to be able to differentiate humic and fulvic acids better than the emission or excitation spectra. Synchronous excitation spectra showed different spectral patterns for the water samples due to different origin. All water samples showed the presence of both fulvic and humic acids.
    Matched MeSH terms: Fluorescence
  14. Koh YM, Saleh MI, Tan SC
    J Chromatogr A, 2003 Feb 14;987(1-2):257-67.
    PMID: 12613820
    An investigation was conducted on the usage of a single-step extraction procedure involving the retention of a phenylboronate-salbutamol complex on an end-capped C18 solid-phase sorbent to determine the level of salbutamol in human plasma samples. Propranolol, a beta-blocker, was chosen as the internal standard for this assay. In this solid-phase clean-up method, 50 mM sodium carbonate buffer, pH 9.60, was used for conditioning the column as well as washing the endogenous interference. Under the optimal conditions, the recovery of salbutamol from spiked plasma samples was found to be high and reproducible with mean recoveries (n = 3) of more than 90% after elution by using 50% 1 M trifluoroacetic acid in methanol. This sample clean-up step was effectively analyzed under reversed-phase high-performance liquid chromatography with fluorimetric detection. The method was successfully applied to the routine measurement of salbutamol in human plasma from the bioequivalence study on the different administration route of salbutamol. Quantification of salbutamol was convincingly reported with the correlation of coefficient of 0.9980 for the concentration range from 0 to 1000 ng ml(-1). An adequate precision was achieved with both between- and within-day precisions of less than 10% (n = 6) for 100 and 1000 ng ml(-1) and less than 15% (n = 6) for 10 ng ml(-1).
    Matched MeSH terms: Spectrometry, Fluorescence
  15. Tai YC, Kim LH, Peh SC
    Pathology, 2003 Oct;35(5):436-43.
    PMID: 14555389
    AIMS: The most common recurrent genetic aberration in anaplastic large cell lymphoma (ALCL) is translocation involving the ALK gene that results in ectopic expression of ALK protein in lymphoid tissue. This study aims to investigate the frequency of ALK gene rearrangement in a series of Asian ALCL.

    METHODS: ALK gene rearrangement was detected by immunostaining of ALK protein and fluorescence in situ hybridisation (FISH) targeting at the 2p23 region.

    RESULTS: The expression of ALK protein was detected in 24/34 (71%) of the cases, and it was significantly higher in childhood cases (100%) when compared to adult cases (47%). The analyses by FISH were consistent with the results from immunostaining of ALK protein, but the analyses were only successful in 15/34 (44%) cases. FISH analyses detected extra copies of ALK gene in three cases, including one case that expressed ALK protein and showed 2p23 rearrangement.

    CONCLUSIONS: The current series revealed a high frequency of ALK gene rearrangement, especially in the children. Immunostaining of ALK protein is a reliable indication of ALK gene rearrangement, and is superior to FISH. However, FISH analysis is useful in detecting other genetic aberrations that are not related to ALK gene rearrangement.

    Matched MeSH terms: In Situ Hybridization, Fluorescence*
  16. Shaminie J, Peh SC, Tan MJ
    Pathology, 2003 Oct;35(5):414-21.
    PMID: 14555386
    AIMS: PCR has been the primary method used for the detection of t(14;18) translocation in formalin-fixed, paraffin-embedded tissues. This technique mainly targets the well-characterised breakpoint regions in chromosomes 14 and 18. FISH is now applicable on paraffin tissue sections and has been suggested to be capable of detecting essentially 100% of t(14;18) translocated cases. In this study, we described the application of both PCR and FISH for the detection of t(14;18) translocation.

    METHODS: Fifty follicular lymphoma cases were retrieved from the files of the Department of Pathology, University of Malaya Medical Centre (UMMC). Nested PCR amplification of MBR/JH and mcr/JH was performed in these cases, and those cases that did not demonstrate the translocation were subjected to FISH analysis.

    RESULTS: Thirty cases (60%) had t(14;18) translocation detected by PCR, 25 (50%) had breakpoint with MBR and five (10%) involved mcr. Twenty cases without detectable t(14;18) translocation by PCR were analysed by FISH. Eleven cases were successfully probed, and four of them showed positive translocation signal.

    CONCLUSIONS: The combination of PCR and FISH analysis on paraffin tissue sections for the detection of t(14;18) translocation increases the sensitivity of detection from 60 to 68%. Problems encountered in our FISH analysis on tissue sections impose certain limitations in using this technique for retrospective screening of large number of samples. Therefore, we suggested the application of PCR as the first screening tool on retrospective archival materials, followed by FISH on those PCR-negative cases.

    Matched MeSH terms: In Situ Hybridization, Fluorescence/methods*
  17. Nik Mohd Polo Kinin NM, Wan Mohd Arif WI, Zainal Arifm A
    Med J Malaysia, 2004 May;59 Suppl B:23-4.
    PMID: 15468800
    The appearance of dental porcelains is comparable to natural teeth. This study discusses the effect of Y2O3 addition to the fluorescent property of dental porcelains. The composition of dental porcelains contained Y2O3 as the fluorescent agent and base frit. The combinations of Y2O3 added consist of a series with 0.5, 1.0, 1.5, 2.0 and 2.5 wt% respectively, based on the total composition. In the extreme condition, fluorescent agents are added from 5.0 up to 10.0 wt%. In order to enhance the fluorescent property of dental porcelains, an opacifiying agent, cerium oxide (CeO2) was also added to dental porcelains composition. The fluorescent property was determined using Spectroline EF-1400C/F that emits 240 nm wavelength ultraviolet light. The microstructure was examined by Scanning Electron Microscope (SEM). The result shows that, the fluorescent properties displayed are similar to natural teeth when subjected to ultraviolet light. SEM micrograph was able to show the fluorescent agent dispersed in glass phase. Increasing additions of Y2O3 gave the fluorescent properties near to natural teeth.
    Matched MeSH terms: Fluorescence
  18. Abdullah Z, Tahir NM, Abas MR, Aiyub Z, Low BK
    Molecules, 2004 Jun 30;9(7):520-6.
    PMID: 18007451
    The reactions of 2-chloropyrimidine with methylamine, ethylamine and piperidine gave the corresponding 2-N-methylamino-, 2-N-ethylamino- and 2N- piperidinopyrimidines, respectively. The fluorescence properties of these alkylamino derivatives in chloroform, ethyl acetate, carbon tetrachloride, acetone, ether, ethanol and methanol were studied. All the alkylamino derivatives showed the highest fluorescence intensity in polar protic solvents; thus 2-N-methylaminopyrimidine (highest fluorescence intensity at 377 nm when excited at 282 nm) and 2-N-ethylaminopyrimidine (highest fluorescence intensity at 375 nm, when excited at 286 nm) showed the highest fluorescence in methanol. In ethanol, 2-N-piperidinopyrimidine showed a fluorescence peak at 403 nm when excited at 360 nm and in chloroform it fluoresced at 392 nm when excited at 356 nm.
    Matched MeSH terms: Fluorescence
  19. Peh SC, Shaminie J, Tai YC, Tan J, Gan SS
    Histopathology, 2004 Nov;45(5):501-10.
    PMID: 15500654
    Follicular lymphoma is frequently associated with t(14;18)(q32;q21) translocation. This study was undertaken to determine the pattern of Bcl-2, CD10 and Bcl-6 expression in relation to t(14;18) translocation in follicular lymphoma from a cohort of a multi-ethnic Asian population.
    Matched MeSH terms: In Situ Hybridization, Fluorescence
  20. Tai YC, Tan JA, Peh SC
    Virchows Arch., 2004 Nov;445(5):506-14.
    PMID: 15365830
    t(11;18)(q21;q21) Translocation and trisomy 3 are the most common chromosomal aberrations reported in low-grade mucosa-associated lymphoid tissue (MALT) lymphoma. The current study aims to investigate the frequency of these chromosomal aberrations in a series of 52 extranodal B-cell lymphomas. The tumours were categorised into three histological grades: grade 1 (low-grade lymphoma of MALT type), grade 2 [diffuse large B-cell lymphoma (DLBCL) with MALT component] and grade 3 (DLBCL without MALT component). Fluorescence in situ hybridisation analyses on paraffin tissue sections were performed using a locus-specific probe for the 18q21 region and a centromeric probe for chromosome 3. The 18q21 rearrangement was detected in 9 of 40 (23%) cases, including 7 of 23 (30%) grade-1 and 2 of 11 (18%) grade-3 tumours. Amplification of the 18q21 region was detected in 10 of 40 (25%) cases, and trisomy 3 was detected in 9 of 34 (26%) cases. Amplification of the 18q21 region may be an important alternative pathogenetic pathway in MALT lymphoma and was found almost exclusively in tumours without 18q21 rearrangement. Our study showed that tumours with 18q21 rearrangement and 18q21 amplification develop along two distinct pathways, and the latter was more likely to transform into high-grade tumours upon acquisition of additional genetic alterations, such as trisomy 3. Trisomy 3 was more frequently found in coexistence with 18q21 abnormalities, suggesting that it was more likely to be a secondary aberration.
    Matched MeSH terms: In Situ Hybridization, Fluorescence
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links