Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Muzaffar TST, Imran Y, Iskandar MA, Zakaria A
    Med J Malaysia, 2005 Jul;60 Suppl C:26-9.
    PMID: 16381279
    Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
    Matched MeSH terms: Fluoroscopy*
  2. Lazarescu A, Chan WW, Gyawali CP, Lee YY, Xiao Y, Wu P
    Ann N Y Acad Sci, 2020 12;1481(1):108-116.
    PMID: 32875574 DOI: 10.1111/nyas.14453
    Esophageal dysphagia is a common symptom in adults. Fluoroscopic contrast studies, endoscopy, and esophageal manometry have been used in the diagnosis of esophageal dysphagia for many years. The diagnostic yield has been improved with new test protocols that highlight abnormal bolus transit in the esophagus and outflow obstruction, as well as new high-definition and high-resolution technical advances in equipment. Functional luminal impedance planimetry and the addition of impedance to high-resolution esophageal manometry have also allowed the assessment of new parameters to better understand esophageal structure and function. In this concise review, we describe the role and utility of various diagnostic modalities in the assessment of patients with esophageal dysphagia.
    Matched MeSH terms: Fluoroscopy
  3. Chilmi MZ, Desnantyo AT, Widhiyanto L, Wirashada BC
    Malays Orthop J, 2020 Jul;14(2):145-148.
    PMID: 32983392 DOI: 10.5704/MOJ.2007.025
    In Indonesia, arthrodesis becomes a choice of treatment in the absence of ankle arthroplasty implants for young adults. Arthrodesis on ankle osteoarthritis (OA) often leads to functional impairment. Low tibiofibular osteotomy is an alternative and it has been known to be the preferable option for those in the productive-ages. A 22-year-old male with a previous history of a motorbike accident, operated eight years ago, came with persistent pain on the left ankle that has worsened over the years. Plain radiography with a tibial-ankle surface angle (TAS) of 74o (normally 88o-93o) indicated varus deformity. Osteotomy was performed on distal tibia above the syndesmotic joint, as well as on the middle third of fibula. Open wedge osteotomy of the tibia was corrected until the normal TAS angle was reached by fluoroscopy. Cortical allograft was used to fill the osteotomy gap. Instrumentation was performed using a clover leaf® plate with 6 screws insertion for fixation stability. All results were satisfactory. Twelve weeks post-operatively, the patient was performing activities normally. Four-month post-operative radiological evaluation showed fusion of graft and the angle of TAS of 89°. Post-operative functional assessment using the American Academy of Orthopaedic Surgeon (AAOS) Foot and Ankle Measurement (FAM) questionnaires showed significant improvement (pre 89, post 38).
    Matched MeSH terms: Fluoroscopy
  4. Philip R, Prepageran N, Waran V
    J Laryngol Otol, 2007 Sep;121(9):e14.
    PMID: 17625037
    Sphenoid sinus mucoceles comprise 1-2 per cent of paranasal sinus mucoceles. Endoscopic marsupialisation is currently the treatment of choice.
    Matched MeSH terms: Fluoroscopy
  5. Fum WKS, Wong JHD, Tan LK
    Phys Med, 2021 Apr;84:228-240.
    PMID: 33849785 DOI: 10.1016/j.ejmp.2021.03.004
    PURPOSE: This systematic review aims to understand the dose estimation approaches and their major challenges. Specifically, we focused on state-of-the-art Monte Carlo (MC) methods in fluoroscopy-guided interventional procedures.

    METHODS: All relevant studies were identified through keyword searches in electronic databases from inception until September 2020. The searched publications were reviewed, categorised and analysed based on their respective methodology.

    RESULTS: Hundred and one publications were identified which utilised existing MC-based applications/programs or customised MC simulations. Two outstanding challenges were identified that contribute to uncertainties in the virtual simulation reconstruction. The first challenge involves the use of anatomical models to represent individuals. Currently, phantom libraries best balance the needs of clinical practicality with those of specificity. However, mismatches of anatomical variations including body size and organ shape can create significant discrepancies in dose estimations. The second challenge is that the exact positioning of the patient relative to the beam is generally unknown. Most dose prediction models assume the patient is located centrally on the examination couch, which can lead to significant errors.

    CONCLUSION: The continuing rise of computing power suggests a near future where MC methods become practical for routine clinical dosimetry. Dynamic, deformable phantoms help to improve patient specificity, but at present are only limited to adjustment of gross body volume. Dynamic internal organ displacement or reshaping is likely the next logical frontier. Image-based alignment is probably the most promising solution to enable this, but it must be automated to be clinically practical.

    Matched MeSH terms: Fluoroscopy
  6. Fum WKS, Md Shah MN, Raja Aman RRA, Abd Kadir KA, Wen DW, Leong S, et al.
    Phys Eng Sci Med, 2023 Dec;46(4):1535-1552.
    PMID: 37695509 DOI: 10.1007/s13246-023-01317-5
    In fluoroscopy-guided interventions (FGIs), obtaining large quantities of labelled data for deep learning (DL) can be difficult. Synthetic labelled data can serve as an alternative, generated via pseudo 2D projections of CT volumetric data. However, contrasted vessels have low visibility in simple 2D projections of contrasted CT data. To overcome this, we propose an alternative method to generate fluoroscopy-like radiographs from contrasted head CT Angiography (CTA) volumetric data. The technique involves segmentation of brain tissue, bone, and contrasted vessels from CTA volumetric data, followed by an algorithm to adjust HU values, and finally, a standard ray-based projection is applied to generate the 2D image. The resulting synthetic images were compared to clinical fluoroscopy images for perceptual similarity and subject contrast measurements. Good perceptual similarity was demonstrated on vessel-enhanced synthetic images as compared to the clinical fluoroscopic images. Statistical tests of equivalence show that enhanced synthetic and clinical images have statistically equivalent mean subject contrast within 25% bounds. Furthermore, validation experiments confirmed that the proposed method for generating synthetic images improved the performance of DL models in certain regression tasks, such as localizing anatomical landmarks in clinical fluoroscopy images. Through enhanced pseudo 2D projection of CTA volume data, synthetic images with similar features to real clinical fluoroscopic images can be generated. The use of synthetic images as an alternative source for DL datasets represents a potential solution to the application of DL in FGIs procedures.
    Matched MeSH terms: Fluoroscopy/methods
  7. Radhi AM, Masbah O, Shukur MH, Shahril Y, Taiman K
    Med J Malaysia, 2006 Feb;61 Suppl A:50-2.
    PMID: 17042230
    Orthopaedic procedures especially dynamic hip screw (DHS) fixation, interlocking nailing (ILN) of the tibia and femur require fluoroscopic assistance. Frequent exposure to radiation is a major concern to members of the orthopaedic surgical team. This study was undertaken to measure shallow (skin) dose to the operating team personnel and deep (whole body) dose to the surgeon during such procedures in view to provide guidelines to the operating team members regarding the number of procedures allowable for them to perform or assist annually. Skin dose for the operating personnel and whole body dose for the operating surgeon during 25 procedures; ten cases of DHS, seven and six cases of ILN of the tibia and femur respectively, was measured using Thermoluminescent Dosimeter (TLD) chips. The shallow radiation dose for theatre personnel ranged from 0.19 mSy to 0.61 per case while the deep dose for the surgeon was 0.28, 0.55 and 0.81 mSy for seven cases of tibial ILN, ten cases of DHS and six cases of femur ILN respectively. The surgeon has the highest radiation exposure than other theatre personnel and the whole body exposure for DHS was higher than that of for ILN. However, the estimated cumulative dose was still far below the permissible annual dose limit.
    Matched MeSH terms: Fluoroscopy/adverse effects*
  8. Lubis LE, Bayuadi I, Pawiro SA, Ng KH, Bosmans H, Soejoko DS
    Phys Med, 2015 Nov;31(7):659-68.
    PMID: 26050060 DOI: 10.1016/j.ejmp.2015.05.011
    The purpose of this study is to quantify the quality of the available imaging modes for various iodine-based contrast agent concentration in paediatric cardiology. The figure of merit (FOM) was defined as the squared signal to noise ratio divided by a patient dose related parameter. An in house constructed phantom simulated a series of vessel segments with iodine concentrations from 10% or 30 mg/cc to 16% or 48 mg/cc of iodine in a blood plasma solution, all within the dimensional constraints of a paediatric patient. The phantom also used test inserts of tin (Sn). Measurements of Entrance Surface Air Kerma (ESAK) and exit dose rate were performed along with calculations of the signal-to-noise ratio (SNR) of all the objects. A first result showed that it was favourable to employ low dose fluoroscopy mode and lower frame rate modes in cine acquisition if dynamic information is not critical. Normal fluoroscopy dose mode provided a considerably higher dose level (in comparison to low dose mode) with only a slight improvement in SNR. Higher frame rate cine modes should be used however when the clinical situation dictates so. This work also found that tin should not be intended as iodine replacement material for research purposes due to the mismatching SNR, particularly on small vessel sizes.
    Matched MeSH terms: Fluoroscopy
  9. Poh KS, Hoh SY, Aziz R, Chong SS, Roslani AC
    Open Med (Wars), 2020;15:261-265.
    PMID: 32292822 DOI: 10.1515/med-2020-0037
    Ultra-low anterior resection for low rectal cancer is usually done with a covering ileostomy as a safety measure to reduce the consequences of distal anastomotic failure. In many centres, distal loopogram is performed routinely, prior to the closure of the loop ileostomy, to assess the integrity of anastomosis. Distal loopogram is generally considered a safe procedure with very low complication rates, especially when water-soluble contrast is used. We report two cases of delayed bowel perforation which led to severe sepsis and generalized peritonitis after distal loopogram prior to ileostomy closure. Our cases highlight the potential dangers of distal loopogram. Therefore, the routine usage of this procedure should be scrutinized and the patient needs to be properly counselled prior to the procedure.
    Matched MeSH terms: Fluoroscopy
  10. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Fluoroscopy/instrumentation; Fluoroscopy/methods
  11. Dass RM, Kim E, Kim HK, Lee JY, Lee HJ, Rhee SJ
    Korean J Pain, 2019 Jul 01;32(3):223-227.
    PMID: 31257831 DOI: 10.3344/kjp.2019.32.3.223
    Radiofrequency neurolysis (RFN) of the genicular nerves has recently become accepted as an effective technique to alleviate knee pain particularly in patients with knee osteoarthritis (OA) or postoperative pain. However, genicular nerve RFN can produce high procedure and equipment costs, longer procedural times, procedure-related pain, and failure rate of over 25%. We are presenting two cases of alcohol neurolysis of the genicular nerve using fluoroscopy and ultrasonography in patients with knee OA or persistent postsurgical pain of the knee. Alcohol neurolysis of the genicular nerve with dual imaging modality can be a cheap, safe and effective method in patients with chronic knee pain.
    Matched MeSH terms: Fluoroscopy
  12. Lim HH, Ong CH
    Med J Malaysia, 2001 Jun;56 Suppl C:41-5.
    PMID: 11814248
    The Pedriolle torsion meter is an established method of vertebral rotation assessment in scoliosis. However, the assessment of scoliosis by this method is static and indirect. The objective of this study is to compare the accuracy of a direct method of assessing scoliosis rotation by fluoroscopy compared to the Pedriolle torsion meter. Secondly, to determine that vertebral body rotation changes with supine posture compared to erect position. Eight volunteers with idiopathic scoliosis were assessed for the apical vertebral rotation with this method and the Pedriolle torsion meter. These patients were also assessed in the supine and erect position with the fluoroscopic method to determine if the apical vertebral rotation would change with posture. The mean Cobb angle of the curves was 62.8 degrees (range 45 degrees to 86 degrees). The mean apical vertebral rotation in a standing position was assessed to be 21.5 degrees by Pedriolle torsion meter and 29 degrees by the fluoroscopic method. This difference was not statistically significant by the student t-test. In most patient, the rotation of vertebrae improved by a varying degree ranging from none to 24 degrees in the supine position. In conclusion, the fluoroscopic method is an alternate mean of measuring vertebrae rotation in idiopathic scoliosis, with comparable accuracy to the Pedriolle torsion meter method. The amount of vertebral rotation changes with posture of the patient.
    Matched MeSH terms: Fluoroscopy
  13. Saidatul A, Azlan C, Megat Amin M, Abdullah B, Ng Kh
    Biomed Imaging Interv J, 2010 Jan-Mar;6(1):e1.
    PMID: 21611060 MyJurnal DOI: 10.2349/biij.6.1.e2
    Computed tomography (CT) fluoroscopy is able to give real time images to a physician undertaking minimally invasive procedures such as biopsies, percutaneous drainage, and radio frequency ablation (RFA). Both operators executing the procedure and patients too, are thus at risk of radiation exposure during a CT fluoroscopy.This study focuses on the radiation exposure present during a series of radio frequency ablation (RFA) procedures, and used Gafchromic film (Type XR-QA; International Specialty Products, USA) and thermoluminescent dosimeters (TLD-100H; Bicron, USA) to measure the radiation received by patients undergoing treatment, and also operators subject to scatter radiation.The voltage was held constant at 120 kVp and the current 70mA, with 5mm thickness. The duration of irradiation was between 150-638 seconds.Ultimately, from a sample of 30 liver that have undergone RFA, the study revealed that the operator received the highest dose at the hands, which was followed by the eyes and thyroid, while secondary staff dosage was moderately uniform across all parts of the body that were measured.
    Matched MeSH terms: Fluoroscopy
  14. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Fluoroscopy/methods
  15. Safari MJ, Wong JHD, Jong WL, Thorpe N, Cutajar D, Rosenfeld A, et al.
    Phys Med, 2017 Mar;35:66-72.
    PMID: 28256398 DOI: 10.1016/j.ejmp.2017.02.002
    PURPOSE: The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures.

    METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.

    RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.

    CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.

    Matched MeSH terms: Fluoroscopy/adverse effects; Fluoroscopy/instrumentation; Fluoroscopy/methods
  16. Wong JHD, Anem LEA, Tan S, Tan SK, Ng KH
    Phys Med, 2019 Dec;68:47-51.
    PMID: 31739145 DOI: 10.1016/j.ejmp.2019.11.007
    OBJECTIVE: This study measured the radiation exposure of the eye lens of medical personnel performing fluoroscopy and interventional procedures at the Sarawak General Hospital in Kuching, Sarawak, Malaysia. This study was the first in Malaysia to utilise in vivo radiation measurement relatively near the eye lens.

    METHODS: 41 medical personnel performing 79 procedures were monitored for their eye lens exposure using the NanoDot™ optically-stimulated luminescence dosimeters (OSLD) taped to the outer canthus of their eyes. The air-kerma area product (KAP), fluoroscopy time (FT) and number of procedure runs were also recorded.

    RESULTS: KAP, FT and number of runs were strongly correlated. However, only weak to moderate correlations were observed between these parameters with the measured eye lens doses. The average median equivalent eye lens dose was 0.052 mSv (ranging from 0.0155 to 0.672 mSv). The eye lens doses of primary operators were found to be significantly higher than their assistants due to the closer proximity to the patient and X-ray tube. The left eye lens of the operators received the highest amount of radiation due to their habitual positioning towards the radiation source.

    CONCLUSION: KAP and FT were not useful in predicting the equivalent eye lens dose exposure in interventional radiological procedures. Direct in vivo measurements were needed to provide a better estimate of the eye lens doses received by medical personnel during these procedures. This study highlights the importance of using direct measurement, such as OSLDs, instead of just indirect factors to monitor dose in the eye lens in radiological procedures.

    Matched MeSH terms: Fluoroscopy/adverse effects
  17. Bohari A, Hashim S, Ghoshal SK, Mohd Mustafa SN
    Radiat Prot Dosimetry, 2019 Dec 31;186(4):462-468.
    PMID: 31329977 DOI: 10.1093/rpd/ncz051
    Long exposure to radiation from fluoroscopy-guided interventions (FGIs) can be detrimental to both patients and radiologists. The effective doses received by the interventional radiology staff after performing 230 FGIs in a year were assessed by using double dosimetry and five various algorithms. The Shapiro-Wilk test revealed normally-distributed data (p < 0.01), while the significant correlation coefficients between the effective doses ranged between 0.88 and 1.00. As for the Bland-Altman analysis, both Niklason and Boetticher algorithms strongly supported the absence of statistical significance between the estimated effective doses. This portrays that the occupational doses received by the interventional radiology staff during FGIs fall within the acceptable limit regardless of the varied algorithms applied. In short, the Niklason and Boetticher algorithms appeared to be the more interchangeable ones for effective evaluation of doses. This is in view of their strong mutual correlations and excellent agreement.
    Matched MeSH terms: Fluoroscopy/methods*
  18. Bohari A, Hashim S, Mohd Mustafa SN
    Radiat Prot Dosimetry, 2020 Jun 24;188(3):397-402.
    PMID: 31950168 DOI: 10.1093/rpd/ncz299
    Radiation scattered throughout the room during fluoroscopy-guided interventional (FGI) procedures was quantified at different locations using nanoDot optically stimulated luminescence dosemeters. All the tube angulation imaging shows that the radiation spectrum resembled a single peak distribution. The left anterior oblique 90° shows the highest single peak distribution (28.65 mSv/h). The single peak distribution for standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging was 13.32, 22.99 and 17.40 mSv/h, respectively. All tube angulation shows that the position of the interventional radiologist experienced a higher radiation level compared to other staffs. The doses of radiation varied widely around the perimeter of the patient's table and changed in accordance to imaging angles during procedures. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly among staff.
    Matched MeSH terms: Fluoroscopy
  19. Noh, K.B., Salim, R., Abdullah, M.S., Mohamad, I.
    Malaysian Family Physician, 2018;13(2):36-38.
    MyJurnal
    Foreign body aspiration is commonly described in infants and children. However, recently, a new
    high-risk group was identified among young women, especially those from the Muslim population
    who wear the traditional hair scarf. This is due to the habit of holding the scarf pin in between the
    lips to free hands to adjust the scarf more easily. Talking, laughing, or coughing while fixing the
    scarf may result in inadvertent inhalation of the pin into the tracheobronchial tree. We present a
    case of scarf pin inhalation and the challenges encountered in managing this patient during the
    successful removal of the pin via flexible bronchoscopy under fluoroscopy guidance. This particular
    case was technically challenging for us as the sharp tip of the needle was pointing upward and
    piercing the bronchial mucosa.
    Matched MeSH terms: Fluoroscopy
  20. Noh KB, Salim R, Abdullah MS, Mohamad I
    Malays Fam Physician, 2018;13(2):36-38.
    PMID: 30302183
    Foreign body aspiration is commonly described in infants and children. However, recently, a new high-risk group was identified among young women, especially those from the Muslim population who wear the traditional hair scarf. This is due to the habit of holding the scarf pin in between the lips to free hands to adjust the scarf more easily. Talking, laughing, or coughing while fixing the scarf may result in inadvertent inhalation of the pin into the tracheobronchial tree. We present a case of scarf pin inhalation and the challenges encountered in managing this patient during the successful removal of the pin via flexible bronchoscopy under fluoroscopy guidance. This particular case was technically challenging for us as the sharp tip of the needle was pointing upward and piercing the bronchial mucosa.
    Matched MeSH terms: Fluoroscopy