Displaying all 16 publications

Abstract:
Sort:
  1. Banihashemian SM, Periasamy V, Boon Tong G, Abdul Rahman S
    PLoS One, 2016;11(3):e0149488.
    PMID: 26999445 DOI: 10.1371/journal.pone.0149488
    Studying the effect of a magnetic field on oligonucleotide DNA can provide a novel DNA manipulation technique for potential application in bioengineering and medicine. In this work, the optical and electrochemical response of a 100 bases oligonucleotides DNA, cytosine-guanine (CG100), is investigated via exposure to different magnetic fields (250, 500, 750, and 1000 mT). As a result of the optical response of CG100 to the magnetic field, the ultra-violet-visible spectrum indicated a slight variation in the band gap of CG100 of about 0.3 eV. Raman spectroscopy showed a significant deviation in hydrogen and phosphate bonds' vibration after exposure to the magnetic field. Oligonucleotide DNA mobility was investigated in the external electric field using the gel electrophoresis technique, which revealed a small decrease in the migration of CG100 after exposure to the magnetic field.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  2. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  3. Keyon AS, Guijt RM, Gaspar A, Kazarian AA, Nesterenko PN, Bolch CJ, et al.
    Electrophoresis, 2014 May;35(10):1496-503.
    PMID: 24591173 DOI: 10.1002/elps.201300353
    Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre- or postcolumn oxidation for fluorescence detection (HPLC-FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on-site monitoring. In this study, CE methods were developed for C(4) D, FLD, UV absorption detection, and MS-making this first report of C(4) D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE-UV and CZE-C(4) D methods provide better resolution, selectivity, and separation efficiency compared to CZE-MS and MEKC-FLD. The sensitivity of the CZE-C(4) D and MEKC-FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE-C(4) D and 60.9 to 104 ng/mL for MEKC-FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE-C(4) D and MEKC-FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE-C(4) D method suffered from significant interferences from the shellfish matrix, MEKC-FLD was successfully used for PST screening of a periodate-oxidized mussel sample, with results confirmed by HPLC-FLD. This confirms the potential of MEKC-FLD for screening of PSTs in shellfish samples.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  4. Al Azzam KM, Saad B, Aboul-Enein HY
    Biomed Chromatogr, 2010 Sep;24(9):977-81.
    PMID: 20066730 DOI: 10.1002/bmc.1395
    Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  5. Lee YZ, Ming-Tatt L, Lajis NH, Sulaiman MR, Israf DA, Tham CL
    Molecules, 2012 Dec 07;17(12):14555-64.
    PMID: 23222902 DOI: 10.3390/molecules171214555
    A sensitive and accurate high performance liquid chromatography with ultraviolet/visible light detection (HPLC-UV/VIS) method for the quantification of 2,6-bis-(4-hydroxy-3-methoxybenzylidene)-cyclohexanone (BHMC) in rat plasma was developed and validated. BHMC and the internal standard, harmaline, were extracted from plasma samples by a simple liquid-liquid extraction using 95% ethyl acetate and 5% methanol. Plasma concentration of BHMC and internal standard were analyzed by reversed phase chromatography using a C₁₈ column (150 × 4.6 mm I.D., particle size 5 µm) and elution with a gradient mobile phase of water and methanol at a flow rate of 1.0 mL/min. Detection of BHMC and internal standard was done at a wavelength of 380 nm. The limit of quantification was 0.02 µg/mL. The calibration curves was linear (R² > 0.999) over the concentration range of 0.02-2.5 µg/mL. Intra- and inter-day precision were less than 2% coefficient of variation. The validated method was then applied to a pharmacokinetic study in rats by intravenous administration of BHMC at a single dose of 10 mg/kg. Pharmacokinetic parameters such as half-life, maximum plasma concentration, volume of distribution, clearance and elimination rate constant for BHMC were calculated.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  6. Nessa F, Ismail Z, Karupiah S, Mohamed N
    J Chromatogr Sci, 2005 Sep;43(8):416-20.
    PMID: 16212782
    A selective and sensitive reversed-phase (RP) high-performance liquid chromatographic method is developed for the quantitative analysis of five naturally occurring flavonoids of Blumea balsamifera DC, namely dihydroquercetin-7,4'-dimethyl ether (DQDE), blumeatin (BL), quercetin (QN), 5,7,3',5'-tetrahydroxyflavanone (THFE), and dihydroquercetin-4'-methyl ether (DQME). These compounds have been isolated using various chromatographic methods. The five compounds are completely separated within 35 min using an RP C18, Nucleosil column and with an isocratic methanol-0.5% phosphoric acid (50:50, v/v) mobile phase at the flow rate of 0.9 mL/min. The separation of the compounds is monitored at 285 nm using UV detection. Identifications of specific flavonoids are made by comparing their retention times with those of the standards. Reproducibility of the method is good, with coefficients of variation of 1.48% for DQME, 2.25% for THFE, 2.31% for QN, 2.23% for DQDE, and 1.51% for BL. The average recoveries of pure flavonoids upon addition to lyophilized powder and subsequent extraction are 99.8% for DQME, 99.9% for THFE, 100.0% for BL, 100.6% for DQDE, and 97.4% for QN.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  7. Ramanathan S, Parthasarathy S, Murugaiyah V, Magosso E, Tan SC, Mansor SM
    Molecules, 2015 Mar 18;20(3):4915-27.
    PMID: 25793541 DOI: 10.3390/molecules20034915
    Varied pharmacological responses have been reported for mitragynine in the literature, but no supportive scientific explanations have been given for this. These studies have been undertaken without a sufficient understanding of the physicochemical properties of mitragynine. In this work a UV spectrophotometer approach and HPLC-UV method were employed to ascertain the physicochemical properties of mitragynine. The pKa of mitragynine measured by conventional UV (8.11 ± 0.11) was in agreement with the microplate reader determination (8.08 ± 0.04). Mitragynine is a lipophilic alkaloid, as indicated by a logP value of 1.73. Mitragynine had poor solubility in water and basic media, and conversely in acidic environments, but it is acid labile. In an in vitro dissolution the total drug release was higher for the simulated gastric fluid but was prolonged and incomplete for the simulated intestinal fluid. The hydrophobicity, poor water solubility, high variability of drug release in simulated biological fluids and acid degradable characteristics of mitragynine probably explain the large variability of its pharmacological responses reported in the literature. The determined physicochemical properties of mitragynine will provide a basis for developing a suitable formulation to further improve its solubility, stability and oral absorption for better assessment of this compound in preclinical studies.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  8. Khan TA, Peh KK, Ch'ng HS
    J Pharm Pharm Sci, 2002 Sep-Dec;5(3):205-12.
    PMID: 12553887
    To investigate and compare the effect of three analytical methods, hydrogen bromide titrimetry (HBr titrimetry), infrared spectroscopy (IR spectroscopy), and first derivative UV-spectrophotometry (FDUV-spectrophotometry) in the determination of degree of deacetylation (DD) of chitosan.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  9. Soliman K, Jirjees F, Sonawane R, Sheshala R, Wang Y, Jones D, et al.
    J Chromatogr Sci, 2021 Jan 01;59(1):64-70.
    PMID: 33047781 DOI: 10.1093/chromsci/bmaa078
    Anti-glaucoma latanoprost-loaded ocular implants provide prolonged delivery and enhanced bioavailability relative to the conventional eye drops. This study aims at the development and validation of a reversed-phase high-performance liquid chromatography method for quantitative analysis of nanogram levels of latanoprost in the eye, and for the first time, compares the use of fluorescence vs ultraviolet (UV) detectors in latanoprost quantification. The mobile phase was composed of acetonitrile:0.1% v/v formic acid (60:40, v/v) with a flow rate of 1 mL/min and separation was done using a C18 column at temperature 40°C. The fluorescence excitation and emission wavelengths were set at 265 and 285 nm, respectively, while the UV absorption was measured at 200 nm. The latanoprost concentration-peak area relationship maintained its linearity (R2 = 0.9999) over concentration ranges of 0.063-10 μg/mL and 0.212-10 μg/mL for the fluorescence and UV detectors, respectively. The UV detector showed better precision, while the fluorescence detector exhibited higher robustness and greater sensitivity, with a detection limit of 0.021 μg/mL. The fluorescence detector was selected for quantification of latanoprost released from ocular implants in vitro and in porcine ocular tissues. The developed method is a robust, rapid and cost-effective alternative to liquid chromatography-mass spectrometry for routine analysis of latanoprost released from ocular implants.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  10. Long CM, Tang K, Chokshi H, Fotaki N
    AAPS PharmSciTech, 2019 Feb 13;20(3):113.
    PMID: 30761437 DOI: 10.1208/s12249-019-1317-z
    The aim of this study is to investigate the dissolution properties of poorly soluble drugs from their pure form and their amorphous formulation under physiological relevant conditions for oral administration based on surface dissolution ultraviolet (UV) imaging. Dissolution of two poorly soluble drugs (cefuroxime axetil and itraconazole) and their amorphous formulations (Zinnat® and Sporanox®) was studied with the Sirius Surface Dissolution Imager (SDI). Media simulating the fasted state conditions (compendial and biorelevant) with sequential media/flow rate change were used. The dissolution mechanism of cefuroxime axetil in simulated gastric fluid (SGF), fasted state simulated gastric fluid (FaSSGF) and simulated intestinal fluid (SIF) is predominantly swelling as opposed to the convective flow in fasted state simulated intestinal fluid (FaSSIF-V1), attributed to the effect of mixed micelles. For the itraconazole compact in biorelevant media, a clear upward diffusion of the dissolved itraconazole into the bulk buffer solution is observed. Dissolution of itraconazole from the Sporanox® compact is affected by the polyethylene glycol (PEG) gelling layer and hydroxypropyl methylcellulose (HPMC) matrix, and a steady diffusional dissolution pattern is revealed. A visual representation and a quantitative assessment of dissolution properties of poorly soluble compounds and their amorphous formulation can be obtained with the use of surface dissolution imaging under in vivo relevant conditions.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  11. Parthasarathy S, Ramanathan S, Ismail S, Adenan MI, Mansor SM, Murugaiyah V
    Anal Bioanal Chem, 2010 Jul;397(5):2023-30.
    PMID: 20454783 DOI: 10.1007/s00216-010-3707-7
    A new solid phase extraction method for rapid high performance liquid chromatography-UV determination of mitragynine in plasma has been developed. Optimal separation was achieved with an isocratic mobile phase consisting of acetonitrile-ammonium acetate buffer, 50 mM at pH 5.0 (50:50, v/v). The method had limits of detection and quantification of 0.025 and 0.050 microg/mL, respectively. The method was accurate and precise for the quantitative analysis of mitragynine in human and rat plasma with within-day and between-day accuracies between 84.0 and 109.6%, and their precision values were between 1.7 and 16.8%. Additional advantages over known methods are related to the solid phase extraction technique for sample preparation which yields a clean chromatogram, a short total analysis time, requires a smaller amount of plasma samples and has good assay sensitivity for bioanalytical application. The method was successfully applied in pharmacokinetic and stability studies of mitragynine. In the present study, mitragynine was found to be fairly stable during storage and sample preparation. The present study showed for the first time the detailed pharmacokinetic profiles of mitragynine. Following intravenous administration, mitragynine demonstrated a biphasic elimination from plasma. Oral absorption of the drug was slow, prolonged and was incomplete, with a calculated absolute oral bioavailability value of 3.03%. The variations observed in previous pharmacokinetic studies after oral administration of mitragynine could be attributed to its poor bioavailability rather than to the differences in assay method, metabolic saturation or mitragynine dose.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  12. Venkatesh G, Ramanathan S, Nair NK, Mansor SM, Sattar MA, Khan MA, et al.
    Biomed Chromatogr, 2007 May;21(5):484-90.
    PMID: 17294505
    A simple and sensitive RP-HPLC-UV method was developed and validated for simultaneous determination of atenolol and propranolol and subsequently applied to investigate the effect of dimethyl sulfoxide in rat in situ intestinal permeability studies. Atenolol (400 microm) and propranolol (100 microm) were perfused in the small intestine of anaesthetized (pentobarbitone sodium 60 mg/kg, i.p.) male Sprague-Dawley rats either in the presence (1, 3 and 5%) or in the absence of dimethyl sulfoxide. There was no significant alteration (p > 0.05) in the permeability of atenolol and propranolol, which indicated there was no effect of various concentrations of dimethyl sulfoxide (1-5%) on the membrane integrity of the rat intestinal tissues. The analytical method was validated on a C(4) column with a mobile phase comprising ammonium acetate buffer (pH 3.5, 0.02 m) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 mL/min. The validated method was found to be accurate and precise and stability studies were carried out at different storage conditions and both analytes were found to be stable. These findings are applicable for determining the absorbability of water-insoluble drugs and new chemical entities for the purpose of classifying them in the biopharmaceutical classification system.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  13. Venkatesh G, Majid MI, Ramanathan S, Mansor SM, Nair NK, Croft SL, et al.
    Biomed Chromatogr, 2008 May;22(5):535-41.
    PMID: 18205140 DOI: 10.1002/bmc.965
    A simple, sensitive and specific reversed-phase high-performance liquid chromatographic method with UV detection at 251 nm was developed for quantitation of buparvaquone (BPQ) in human and rabbit plasma. The method utilizes 250 microL of plasma and sample preparation involves protein precipitation followed by solid-phase extraction. The method was validated on a C18 column with mobile phase consisting of ammonium acetate buffer (0.02 m, pH 3.0) and acetonitrile in the ratio of 18:82 (v/v) at a flow rate of 1.1 mL/min. The calibration curves were linear (correlation coefficient>or=0.998) in the selected range. The method is specific and sensitive with limit of quantitation of 50 ng/mL for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and BPQ was found to be stable. Partial validation studies were carried out using rabbit plasma and intra- and inter-day precision and accuracy were within 7%. This method is simple, reliable and can be routinely used for preclinical pharmacokinetic studies for BPQ.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  14. Tan DC, Quek A, Kassim NK, Ismail IS, Lee JJ
    Molecules, 2020 Nov 06;25(21).
    PMID: 33171900 DOI: 10.3390/molecules25215162
    Scopoletin has previously been reported as a biomarker for the standardization of Paederia foetida twigs. This study is the first report on the determination and quantification of scopoletin using quantitative nuclear magnetic resonance (qNMR) in the different extracts of Paederia foetida twigs. The validated qNMR method showed a good linearity (r2 = 0.9999), limit of detection (LOD) (0.009 mg/mL), and quantification (LOQ) (0.029 mg/mL), together with high stability (relative standard deviation (RSD) = 0.022%), high precision (RSD < 1%), and good recovery (94.08-108.45%). The quantification results of scopoletin concentration in chloroform extract using qNMR and microplate ultraviolet-visible (UV-vis) spectrophotometer was almost comparable. Therefore, the qNMR method is deemed accurate and reliable for quality control of Paederia foetida and other medicinal plants without extensive sample preparation.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
  15. Irfan M, Usman M, Mansha A, Rasool N, Ibrahim M, Rana UA, et al.
    ScientificWorldJournal, 2014;2014:540975.
    PMID: 25243216 DOI: 10.1155/2014/540975
    The present study describes the conductometric and spectroscopic study of the interaction of reactive anionic dyes, namely, reactive red 223 and reactive orange 122 with the cationic surfactant cetyltrimethyl ammonium bromide (CTAB). In a systematic investigation, the electrical conductivity data was used to calculate various thermodynamic parameters such as free energy (ΔG), enthalpy (ΔH), and the entropy (ΔS) of solubilization. The trend of change in these thermodynamic quantities indicates toward the entropy driven solubilization process. Moreover, the results from spectroscopic data reveal high degree of solubilization, with strong interactions observed in the cases of both dyes and the CTAB. The spontaneous nature of solubilization and binding was evident from the observed negative values of free energies (ΔG p and ΔG b).
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods
  16. Venkatesh G, Ramanathan S, Mansor SM, Nair NK, Sattar MA, Croft SL, et al.
    J Pharm Biomed Anal, 2007 Mar 12;43(4):1546-51.
    PMID: 17157469
    A simple, sensitive and specific reversed phase high performance liquid chromatographic (RP-HPLC) method with UV detection at 251 nm was developed for simultaneous quantitation of buparvaquone (BPQ), atenolol, propranolol, quinidine and verapamil. The method was applicable in rat in situ intestinal permeability study to assess intestinal permeability of BPQ, a promising lead compound for Leishmania donovani infections. The method was validated on a C-4 column with mobile phase comprising ammonium acetate buffer (0.02 M, pH 3.5) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 ml/min. The retention times for atenolol, quinidine, propranolol, verapamil and BPQ were 4.30, 5.96, 6.55, 7.98 and 8.54 min, respectively. The calibration curves were linear (correlation coefficient > or =0.996) in the selected range of each analyte. The method is specific and sensitive with limit of quantitation of 15 microg/ml for atenolol, 0.8 microg/ml for quinidine, 5 microg/ml for propranolol, 10 microg/ml for verapamil and 200 ng/ml for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and all the analytes were found to be stable. This method is simple, reliable and can be routinely used for accurate permeability characterization.
    Matched MeSH terms: Spectrophotometry, Ultraviolet/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links