SUBJECTS/METHODS: A total of 181 Thai children (90 boys and 91 girls) aged 6 to 12 years were recruited. Bone status was measured by two different techniques in terms of the speed of sound (SOS) using QUS and bone mineral density (BMD) using DXA. Calcium intake was assessed by 24 h diet recall. Pearson's correlation, κ-statistic and Bland and Altman analysis were used to assess the agreement between the methods.
RESULTS: There was no correlation between the two different techniques. Mean difference (s.d.) of the Z-scores of BMD and SOS was -0.61 (1.27) that was different from zero (P<0.05). Tertiles of Z-scores of BMD and QUS showed low agreement (κ 0.022, P=0.677) and the limits of agreement in Bland and Altman statistics were wide.
CONCLUSIONS: Although QUS is easy and convenient to use, the SOS measurements at the radius seem not appropriate for assessing bone quality status.
OBJECTIVE: Our aim was to create and describe a homemade, high-fidelity ultrasound phantom model for demonstrating pneumonia with pleural effusions for teaching purposes.
DISCUSSION: An ultrasound phantom was constructed using a water-filled latex glove with a sliver of meat in it, covered over by a palm-sized piece of meat (skin and ribs are optional to increase ultrasonographic details and realism). This would appear like parapneumonic effusions with organized pneumonia under ultrasound examination. Creamer (or talc) can be added to the water in the glove to simulate empyema. The model can also be used to teach simple effusions and for ultrasound-guided thoracentesis and in clinical decision making.
CONCLUSIONS: Easily prepared, homemade high-fidelity ultrasound phantom models for instructions on identification of pleural effusions and ultrasound-guided pleural tap of parapneumonic effusion were made.
DESIGN: Prospective study.
SETTING: University hospital.
PATIENT(S): Six hundred ten women undergoing SHG.
INTERVENTION(S): We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN).
MAIN OUTCOME MEASURE(S): We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters.
RESULT(S): In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive.
CONCLUSION(S): The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.