Displaying publications 21 - 40 of 194 in total

Abstract:
Sort:
  1. Dahlan I, Lee KT, Kamaruddin AH, Mohamed AR
    Environ Sci Technol, 2006 Oct 01;40(19):6032-7.
    PMID: 17051796
    Siliceous materials such as rice husk ash (RHA) have potential to be utilized as high performance sorbents for the flue gas desulfurization process in small-scale industrial boilers. This study presents findings on identifying the key factorfor high desulfurization activity in sorbents prepared from RHA. Initially, a systematic approach using central composite rotatable design was used to develop a mathematical model that correlates the sorbent preparation variables to the desulfurization activity of the sorbent. The sorbent preparation variables studied are hydration period, x1 (6-16 h), amount of RHA, x2 (5-15 g), amount of CaO, x3 (2-6 g), amount of water, x4 (90-110 mL), and hydration temperature, x5 (150-250 degrees C). The mathematical model developed was subjected to statistical tests and the model is adequate for predicting the SO2 desulfurization activity of the sorbent within the range of the sorbent preparation variables studied. Based on the model, the amount of RHA, amount of CaO, and hydration period used in the preparation step significantly influenced the desulfurization activity of the sorbent. The ratio of RHA and CaO used in the preparation mixture was also a significant factor that influenced the desulfurization activity of the sorbent. A RHA to CaO ratio of 2.5 leads to the formation of specific reactive species in the sorbent that are believed to be the key factor responsible for high desulfurization activity in the sorbent. Other physical properties of the sorbent such as pore size distribution and surface morphology were found to have insignificant influence on the desulfurization activity of the sorbent.
    Matched MeSH terms: Air Pollutants/isolation & purification*; Air Pollutants/chemistry
  2. Omar NY, Mon TC, Rahman NA, Abas MR
    Sci Total Environ, 2006 Oct 1;369(1-3):76-81.
    PMID: 16766020
    The concentrations and distributions of particle bound polycyclic aromatic hydrocarbons (PAHs) collected over a 10 month period in ambient environment, at street levels as well as during a hazy episode are reported. Ambient and street level distributions of PAHs were similar and their occurrence was attributed to vehicular emissions. However, in haze particles, a different pattern of PAHs was observed, characterized by relatively low levels of benzo[a]pyrene (BaP) and high levels of benzofluoranthenes (BFs). The BaP equivalency results showed that the potential health risk associated with haze smoke particles was 4 times higher than that of street level particles whereas the lowest health risk was associated with ambient atmospheric particles.
    Matched MeSH terms: Air Pollutants/analysis*
  3. Raymond-Ooi EH, Lee KT, Mohamed AR, Chu KH
    PMID: 16423725
    The mechanistic modeling of the sulfation reaction between fly ash-based sorbent and SO2 is a challenging task due to a variety reasons including the complexity of the reaction itself and the inability to measure some of the key parameters of the reaction. In this work, the possibility of modeling the sulfation reaction kinetics using a purely data-driven neural network was investigated. Experiments on SO2 removal by a sorbent prepared from coal fly ash/CaO/CaSO4 were conducted using a fixed bed reactor to generate a database to train and validate the neural network model. Extensive SO2 removal data points were obtained by varying three process variables, namely, SO2 inlet concentration (500-2000 mg/L), reaction temperature (60-80 degreesC), and relative humidity (50-70%), as a function of reaction time (0-60 min). Modeling results show that the neural network can provide excellent fits to the SO2 removal data after considerable training and can be successfully used to predict the extent of SO2 removal as a function of time even when the process variables are outside the training domain. From a modeling standpoint, the suitably trained and validated neural network with excellent interpolation and extrapolation properties could have immediate practical benefits in the absence of a theoretical model.
    Matched MeSH terms: Air Pollutants/isolation & purification*
  4. Niza S, Jamal HH
    Int J Environ Health Res, 2007 Apr;17(2):95-103.
    PMID: 17616865
    A comparative cross-sectional study was conducted to determine tollbooth carbon monoxide (CO) levels and carboxyhaemoglobin (COHb) levels among the tollbooth operators and office workers in the Klang Valley, Kuala Lumpur. All tollbooths were equipped with well functioning air-conditioning. The total number of respondents was 180: 90 toll operators and 90 office workers aged between 19 and 52 years. The highest peak of CO level recorded was 61 ppm. The highest average peak CO level within a shift was 30 ppm. The CO level was higher during peak traffic at 6.00 - 8.00 a.m. There was no significant correlation between average peak CO level with vehicle load (r = -0.007, p = 0.474). The toll operators' median COHb level (1.0%, IQR = 0.8%) was significantly higher (p = 0.008) compared to office workers (0.7%, IQR = 0.8). There was a weak and significant correlation between COHb levels with average peak CO levels (r = 0.228, p = 0.031). In conclusion, tollbooth operators were chronically exposed to CO leading to higher COHb levels compared to office workers.
    Matched MeSH terms: Air Pollutants, Occupational/analysis*
  5. Noorddin Y, Raha AR, Jaafar MZ, Rozaidi SH, Muraly S, Marlizan MY
    Med J Malaysia, 2007 Jun;62(2):127-9.
    PMID: 18705444 MyJurnal
    The use of laryngeal mask airway (LMA) as an alternative to the endotracheal tube (ETT) is becoming more popular in the practice of anesthesia. It is undeniable that this device has numerous advantages over endotracheal tube, however it does not provide an airtight seal between the airway and atmospheric gases. This may lead to pollution of the operating room environment with nitrous oxide. One hundreds adult patients undergoing general anaesthesia were divided into two groups. The airway in Group I was maintained with LMA with spontaneous ventilation and ETT with intermittent positive pressure ventilation (IPPV) was used for Group II. The result demonstrated that the ETT group recorded concentrations of nitrous oxide that were well above the NIOSH recommended eight hour time weighted average of 25ppm throughout the duration of surgery when compared to patients using LMA.
    Matched MeSH terms: Air Pollutants, Occupational/analysis*
  6. Ishii S, Bell JN, Marshall FM
    Environ Pollut, 2007 Nov;150(2):267-79.
    PMID: 17379364
    The phytotoxic risk of ambient air pollution to local vegetation was assessed in Selangor State, Malaysia. The AOT40 value was calculated by means of the continuously monitored daily maximum concentration and the local diurnal pattern of O3. Together with minor risks associated with the levels of NO2 and SO2, the study found that the monthly AOT40 values in these peri-urban sites were consistently over 1.0 ppm.h, which is well in exceedance of the given European critical level. Linking the O3 level to actual agricultural crop production in Selangor State also indicated that the extent of yield losses could have ranged from 1.6 to 5.0% (by weight) in 2000. Despite a number of uncertainties, the study showed a simple but useful methodological framework for phytotoxic risk assessment with a limited data set, which could contribute to appropriate policy discussion and countermeasures in countries under similar conditions.
    Matched MeSH terms: Air Pollutants/toxicity
  7. Omar M, Sulaiman I, Hassan A, Wood AK
    Radiat Prot Dosimetry, 2007;124(4):400-6.
    PMID: 17510205
    Measurements of external radiation level, radon/thoron daughters concentrations in air and uranium/thorium concentrations in airborne mineral dust at 16 amang plants in Malaysia were carried out for three consecutive months to assess radiation dose to workers. Estimated occupational dose was within the range of 1.7-10.9 mSv y(-1). The mean total dose at the amang plants was 4.1 mSv y(-1). Overall, it was found that the major dose contribution of 80% came from external radiation. Radon/thoron daughters and airborne mineral dust contributed to only 11 and 9% of the total dose, respectively.
    Matched MeSH terms: Air Pollutants, Occupational/analysis*; Air Pollutants, Radioactive/analysis
  8. Mohd Suhaimi Hamzah, Shamsiah Abdul Rahman, Abdul Khalik Wood
    MyJurnal
    Atmospheric Pollution due to airborne particle is a major concern to many cities in the Southeast Asian region, including Kuala Lumpur. Within the last six years air particulate samples have been collected from a site in Kuala Lumpur and measured for their PM10, PM2.5 and elemental concentrations. The results showed that the daily PM10 (
    Matched MeSH terms: Air Pollutants
  9. Edimansyah BA, Rusli BN, Naing L, Azwan BA, Aziah BD
    PMID: 19323052
    The purpose of this study was to determine the indoor air quality (IAQ) status of an automotive assembly plant in Rawang, Selangor, Malaysia using selected IAQ parameters, such as carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH) and respirable particulate matter (PM10). A cross-sectional study was conducted in the paint shop and body shop sections of the plant in March 2005. The Q-TRAK Plus IAQ Monitor was used to record the patterns of CO, CO2, RH and temperature; whilst PM10 was measured using DUSTTRAK Aerosol Monitor over an 8-hour time weight average (8-TWA). It was found that the average temperatures, RH and PM10 in the paint shop section and body shop sections exceeded the Department of Safety and Health (DOSH) standards. The average concentrations of RH and CO were slightly higher in the body shop section than in the paint shop section, while the average concentrations of temperature and CO2 were slightly higher in the paint shop section than in the body shop section. There was no difference in the average concentrations of PM10 between the two sections.
    Matched MeSH terms: Air Pollutants, Occupational/analysis*
  10. Bhatia S, Wong CT, Abdullah AZ
    J Hazard Mater, 2009 May 30;164(2-3):1110-7.
    PMID: 18976860 DOI: 10.1016/j.jhazmat.2008.09.040
    The low concentration and high flow rate of air-borne butyl acetate (BA) could be effectively removed using combined adsorption-catalytic oxidation system. Ag-Y (Si/Al=80) dual-function adsorbent was investigated for the adsorption step of 1000 ppm of butyl acetate at gas hourly space velocity of 13,000 h(-1) at ambient temperature under dry and humid feeds. A central composite design (CCD) coupled with response surface methodology (RSM) was employed to obtain the optimum process conditions and the interactions between process variables were demonstrated and elucidated. Humidity and increasing organic concentration shortened the adsorption service time. The effect of moisture was more pronounced at low BA concentration. The interactions between the BA concentration and humidity were statistically significant at 95% confidence level. The optimum conditions were found to be at 4500 ppm of BA with 37 min saturation time to give 58 mg BA/g as adsorption capacity. The simulated data fitted the experimental data satisfactorily. The simulated data also correctly demonstrated the overall behaviors of the adsorption process.
    Matched MeSH terms: Air Pollutants/isolation & purification*
  11. Dahlan I, Lee KT, Kamaruddin AH, Mohamed AR
    J Hazard Mater, 2009 Jul 30;166(2-3):1556-9.
    PMID: 19147280 DOI: 10.1016/j.jhazmat.2008.12.028
    In this work, the removal of SO(2) and NO from simulated flue gas from combustion process was investigated in a fixed-bed reactor using rice husk ash (RHA)/CaO-based sorbent. Various metal precursors were used in order to select the best metal impregnated over RHA/CaO sorbents. The results showed that RHA/CaO sorbents impregnated with CeO(2) had the highest sorption capacity among other impregnated metal oxides for the simultaneous removal of SO(2) and NO. Infrared spectroscopic results indicated the formation of both sulfate (SO(4)(2-)) and nitrate (NO(3)(-)) species due to the catalytic role played by CeO(2). Apart from that, the catalytic activity of the RHA/CaO/CeO(2) sorbent was found to be closely related to its physical properties (specific surface area, total pore volume and average pore diameter).
    Matched MeSH terms: Air Pollutants/isolation & purification
  12. Mohd Tahir N, Poh SC, Suratman S, Ariffin MM, Shazali NA, Yunus K
    Bull Environ Contam Toxicol, 2009 Aug;83(2):199-203.
    PMID: 19436928 DOI: 10.1007/s00128-009-9751-3
    Results from the present study in Kuala Terengganu, Malaysia indicated a significant spatial variation but generally the total suspended particulate concentrations (mean = 17.2-148 microg/m(3)) recorded were below the recommended Malaysia guideline for total suspended particulate (mean of 24-h measurement = 260 microg/m(3)). Some of the elemental composition of particulate aerosol is clearly affected by non crustal sources, e.g. vehicular emission sources. Based on correlation and enrichment analyses, the elements could be grouped into two i.e. Pb, Cd and Zn group with sources from vehicular emission (r > 0.6; enrichment factor > 10) and Al, Fe, Mn and Cr group that appears to be of crustal origin (r > 0.6; enrichment factor < 10). It can also be concluded that the mean levels of Pb (1 ng/m(3)), Cd (0.02 ng/m(3)) and Zn (2 ng/m(3)) in the study area are generally lower than other urban areas in Malaysia (Pb < 181 ng/m(3); Cd < 6 ng/m(3); Zn < 192 ng/m(3)).
    Matched MeSH terms: Air Pollutants/analysis; Air Pollutants/chemistry*
  13. Azmi SZ, Latif MT, Ismail AS, Juneng L, Jemain AA
    Air Qual Atmos Health, 2010 Mar;3(1):53-64.
    PMID: 20376168
    Over the last decades, the development of the Klang Valley (Malaysia), as an urban commercial and industrial area, has elevated the risk of atmospheric pollutions. There are several significant sources of air pollutants which vary depending on the background of the location they originate from. The aim of this study is to determine the trend and status of air quality and their correlation with the meteorological factors at different air quality monitoring stations in the Klang Valley. The data of five major air pollutants (PM(10), CO, SO(2), O(3), NO(2)) were recorded at the Alam Sekitar Sdn Bhd (ASMA) monitoring stations in the Klang Valley, namely Petaling Jaya (S1), Shah Alam (S2) and Gombak (S3). The data from these three stations were compared with the data recorded at Jerantut, Pahang (B), a background station established by the Malaysian Department of Environment. Results show that the concentrations of CO, NO(2) and SO(2) are higher at Petaling Jaya (S1) which is due to influence of heavy traffic. The concentrations of PM(10) and O(3,) however, are predominantly related to regional tropical factors, such as the influence of biomass burning and of ultra violet radiation from sunlight. They can, though, also be influenced by local sources. There are relatively stronger inter-pollutant correlations at the stations of Gombak and Shah Alam, and the results also suggest that heavy traffic flow induces high concentrations of PM(10), CO, NO(2) and SO(2) at the three sampling stations. Additionally, meteorological factors, particularly the ambient temperature and wind speed, may influence the concentration of PM(10) in the atmosphere.
    Matched MeSH terms: Air Pollutants
  14. Md Yusof NF, Ramli NA, Yahaya AS, Sansuddin N, Ghazali NA, Al Madhoun W
    Environ Monit Assess, 2010 Apr;163(1-4):655-67.
    PMID: 19365611 DOI: 10.1007/s10661-009-0866-0
    There are many factors that influence PM(10) concentration in the atmosphere. This paper will look at the PM(10) concentration in relation with the wet season (north east monsoon) and dry season (south west monsoon) in Seberang Perai, Malaysia from the year 2000 to 2004. It is expected that PM(10) will reach the peak during south west monsoon as the weather during this season becomes dry and this study has proved that the highest PM(10) concentrations in 2000 to 2004 were recorded in this monsoon. Two probability distributions using Weibull and lognormal were used to model the PM(10) concentration. The best model used for prediction was selected based on performance indicators. Lognormal distribution represents the data better than Weibull distribution model for 2000, 2001, and 2002. However, for 2003 and 2004, Weibull distribution represents better than the lognormal distribution. The proposed distributions were successfully used for estimation of exceedences and predicting the return periods of the sequence year.
    Matched MeSH terms: Air Pollutants/analysis
  15. Mirmohammadi M, Hakimi Ibrahim M, Ahmad A, Kadir MO, Mohammadyan M, Mirashrafi SB
    Environ Monit Assess, 2010 Jun;165(1-4):341-7.
    PMID: 19444630 DOI: 10.1007/s10661-009-0950-5
    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.
    Matched MeSH terms: Air Pollutants, Occupational/analysis*; Air Pollutants, Occupational/urine
  16. Latif IK, Karim AJ, Zuki AB, Zamri-Saad M, Niu JP, Noordin MM
    Poult Sci, 2010 Jul;89(7):1379-88.
    PMID: 20548065 DOI: 10.3382/ps.2009-00622
    Aftermath in several air pollution episodes with high concentrations of polycyclic aromatic hydrocarbons did not significantly affect health and performance of broilers despite its renowned sensitivity to polycyclic aromatic hydrocarbons. The aim of the study was to elucidate the previous lack of response in birds exposed to such severe episodes of air pollution. Benzo[a]pyrene (BaP) was used to simulate the influence of air pollution on hematology, selected organ function, and oxidative stress in broilers. One-day-old chicks were assigned to 5 equal groups composed of a control group, tricaprylin group, and 3 groups treated with BaP (at 1.5 microg, 150 microg, or 15 mg/kg of BW). The BaP was intratracheally administered to 1-d-old chicks for 5 consecutive days. The hematology, liver and kidney function, P450 activity, and malondialdehyde level especially in the group receiving 15 mg of BaP/kg of BW demonstrated evidence of hemato- and hepatoxicity via BaP-induced oxidative stress. The deleterious effect of exposure to high concentration of BaP in broiler chickens was probably due to the anatomy of this species and the half-life of BaP. Although the effect of BaP may be transient or irreversible, pathogen challenges faced during the period of suppression may prove fatal.
    Matched MeSH terms: Air Pollutants/toxicity*
  17. Lau LC, Lee KT, Mohamed AR
    J Hazard Mater, 2010 Nov 15;183(1-3):738-45.
    PMID: 20724075 DOI: 10.1016/j.jhazmat.2010.07.088
    In order to reduce the negative impact of coal utilization for energy generation, the pollutants present in the flue gas of coal combustion such as sulfur dioxide (SO(2)) and nitrogen oxide (NO) must be effectively removed before releasing to the atmosphere. Thus in this study, sorbent prepared from rice husk ash that is impregnated with copper is tested for simultaneous removal of SO(2) and NO from simulated flue gas. The effect of various sorbent preparation parameters; copper loading, RHA/CaO ratio, hydration period and NaOH concentration on the sorbent desulfurization/denitrification capacity was studied using Design-Expert Version 6.0.6 software. Specifically, Central Composite Design (CCD) coupled with Response Surface Method (RSM) was used. Significant individual parameters that affect the sorbent capacity are copper loading and NaOH concentration. Apart from that, interaction between the following parameters was also found to have significant effect; copper loading, RHA/CaO ratio and NaOH concentration. The optimum sorbent preparation condition for this study was found to be 3.06% CuO loading, RHA/CaO ratio of 1.41, 8.05 h of hydration period and NaOH concentration of 0.80 M. Sorbent characterization using SEM, XRD and surface area analysis were used to describe the effect of sorbent preparation parameters on the desulfurization/denitrification activity.
    Matched MeSH terms: Air Pollutants/isolation & purification*
  18. Sulaiman, I., Omar, M.
    MyJurnal
    The indoor and outdoor radon/thoron progenies concentrations and natural background radiation levels throughout Sarawak and Sabah were measured. The measurements were carried out at 234 locations in 40 towns in Sarawak and Sabah. The mean indoor and outdoor radon equilibrium equivalent concentrations (EEC) in Sarawak were found to be 1.2 Bqm-3 and 1.5 Bqm-3 respectively. In Sabah, the mean indoor and outdoor radon equilibrium equivalent concentrations were 1.7 Bqm-3. The mean indoor and outdoor thoron equilibrium equivalent concentrations of 0.4 Bqm-3 and 0.3Bqm-3 respectively, were the same for Sarawak and Sabah. The mean indoor and outdoor radiation levels of 46 nGyh-1 and 42 nGyh-1 in Sarawak were slightly lower than the respective values in Sabah, i.e. 53 nGyh-1 and 46 nGy h-1.
    Matched MeSH terms: Air Pollutants, Radioactive
  19. Rosli H. Mahat
    MyJurnal
    A month hourly measurement of radon concentration was taken in the bedroom of a two story link house in Kuala Lumpur. The house is a typical urban house in Malaysia, constructed with bricks, concrete and cement plaster. These materials are natural sources of radon in the house. The hourly radon concentration was found to vary from 0 pCiL-1 to 3 pCiL-1. It was found to peak during early morning and to minimize in the evening. The daily average radon concentration varied from 0.2 pCiL-1 to 1.0 pCiL-1.
    Matched MeSH terms: Air Pollutants, Radioactive
  20. Anwar A, Liew J, Othman M, Latif M
    Sains Malaysiana, 2010;39:169-174.
    Biomass burning is one of the main sources of air pollution in South East Asia, predominantly during the dry period between June and October each year. Sumatra and Kalimantan, Indonesia, have been identified as the regions connected to biomass burning due to their involvement in agricultural activities. In Sumatra, the Province of Riau has always been found to have had the highest number of hotspots during haze episodes. This study aims to determine the concentration of five major pollutants (PM10, SO2, NO2, CO and O3) in Riau, Indonesia, for 2006 and 2007. It will also correlate the level of air pollutants to the number of hotspots recorded, using the hotspot information system introduced by the Malaysian Centre for Remote Sensing (MACRES). Overall, the concentration of air pollutants recorded was found to increase with the number of hotspots. Nevertheless, only the concentration of PM10 during a haze episode is significantly different when compared to its concentration in non-haze conditions. In fact, in August 2006, when the highest number of hotspots was recorded the concentration of PM10 was found to increase by more than 20% from its normal concentration. The dispersion pattern, as simulated by the Hybrid Single Particle Lagrangian Integrated Trajectory Model (HYSPLIT), showed that the distribution of PM10 was greatly influenced by the wind direction. Furthermore, the particles had the capacity to reach the Peninsular Malaysia within 42 hours of emission from the point sources as a consequence of the South West monsoon.
    Matched MeSH terms: Air Pollutants
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links