Displaying publications 21 - 36 of 36 in total

Abstract:
Sort:
  1. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  2. Azarisma, S.M.S., Rosli, M.A.B.
    MyJurnal
    We report a-56-year old army pensioner who presented initially to a peripheral hospital with acute ST-elevation inferior myocardial infarction thrombolysed with streptokinase. He was subsequently referred to the National Heart Institute (Institut Jantung Negara, Malaysia) for coronary revascularization. Coronary angiogram revealed an ectatic right coronary artery with discrete lesions at the proximal and distal segments stented with bare metal stents (BMS). Post dilatation shots revealed a wire-induced, distal dissection at the posterior left ventricular artery remedied by balloon angioplasty but resulting in balloon-induced crumpling of the distal BMS. We discuss the importance of sequential, distal-to-proximal coronary intervention, stent crumpling and remedial strategies.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  3. Ngow H
    Kardiol Pol, 2009 Sep;67(9):1040-2 discussion 1043.
    PMID: 19838965
    Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the proximal left anterior descending (LAD) coronary artery prior to deployment. This patient however was successfully treated with re-wiring of the artery with two parallel wires and the stent's reposition prior to deployment with the help of a small balloon.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  4. Liew HB, Rosli MA, Wan Azman WA, Robaayah Z, Sim KH, NCVD PCI investigators
    Med J Malaysia, 2008 Sep;63 Suppl C:41-4.
    PMID: 19230246
    The National Cardiovascular Database for Percutaneous Coronary Intervention (NCVD PCI) Registry is the first multicentre interventional cardiology project, involving the main cardiac centres in the country. The ultimate goal of NCVD PCI is to provide a contemporary appraisal of PCI in Malaysia. This article introduces the foundation, the aims, methodology, database collection and preliminary results of the first six-month database.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/statistics & numerical data*
  5. Devasia T, Shetty PN, Kareem H, Karkala YR, Singh A
    Indian Heart J, 2018 Dec;70 Suppl 3(Suppl 3):S353-S358.
    PMID: 30595288 DOI: 10.1016/j.ihj.2018.10.411
    BACKGROUND: Lifestyle modification (LSM) such as prudent diet, physical activity, avoidance of smoking, and maintaining a healthy weight may considerably decrease the risk for coronary artery disease.

    OBJECTIVE: The primary objective of this study was to develop a new LSM scoring system and investigate the correlation between adherence to LSM and incidence of major adverse cardiac events (MACEs) at 12-month follow-up.

    METHOD: A total of 1000 consecutive patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were included in this prospective single-center study. Manipal lifestyle modification score (MLSMS) was developed by using five lifestyle-related factors. Adherence to LSM at the baseline and subsequent follow-ups was determined by using MLSMS. The MACE at 1-, 6-, and 12-month follow-up were analyzed.

    RESULTS: There was a significant reduction in overall adherence to LSM (p 

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  6. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*
  7. Thuraisingham S, Tan KH
    Int J Clin Pract, 1999 Dec;53(8):604-7.
    PMID: 10692754
    Direct coronary angioplasty with stent implantation is an effective treatment for acute myocardial infarction. The use of adjunctive abciximab, a platelet glycoprotein IIb/IIIa receptor antagonist is expensive. We report on three cases of direct coronary angioplasty complicated by extensive thrombus formation that were successfully treated with attenuated dosing of abciximab via the intracoronary route. All patients presented with acute myocardial infarction complicated by cardiogenic shock or eminent cardiogenic shock. Abciximab was administered after balloon dilatation when extensive thrombus formation was noted and persisted despite repeated inflations. In all three patients a single 10 mg vial of intracoronary abciximab was administered, resulting in complete dissolution of thrombus, allowing successful deployment of stents. Thus, a single 10 mg intracoronary bolus dose of abciximab may be sufficient to achieve high local concentrations of antiplatelet activity. This facilitates thrombus dissolution and allows the safe deployment of a stent to normalise intracoronary rheology.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  8. Loch A, Bewersdorf JP, Veeriah RS
    Indian Heart J, 2017 03 17;69(5):651-654.
    PMID: 29054192 DOI: 10.1016/j.ihj.2017.03.002
    The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106-238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  9. Zuhdi AS, Mariapun J, Mohd Hairi NN, Wan Ahmad WA, Abidin IZ, Undok AW, et al.
    Ann Saudi Med, 2014 1 15;33(6):572-8.
    PMID: 24413861 DOI: 10.5144/0256-4947.2013.572
    BACKGROUND AND OBJECTIVES: Understanding the nature and pattern of young coronary artery disease (CAD) is important due to the tremendous impact on these patients' socio-economic and physical aspect. Data on young CAD in the southeast Asian region is rather patchy and limited. Hence we utilized our National Cardiovascular Disease Database (NCVD)-Percutaneous Coronary Intervention (PCI) Registry to analyze young patients who underwent PCI in the year 2007 to 2009.

    DESIGN AND SETTINGS: This is a retrospective study of all patients who had undergone coronary angioplasty from 2007 to 2009 in 11 hospitals across Malaysia.

    METHODS: Data were obtained from the NCVD-PCI Registry, 2007 to 2009. Patients were categorized into 2 groups-young and old, where young was defined as less than 45 years for men and less than 55 years for women and old was defined as more than or equals to 45 years for men and more than or equals to 55 years for women. Patients' baseline characteristics, risk factor profile, extent of coronary disease and outcome on dis.charge, and 30-day and 1-year follow-up were compared between the 2 groups.

    RESULTS: We analyzed 10268 patients, and the prevalence of young CAD was 16% (1595 patients). There was a significantly low prevalence of Chinese patients compared to other major ethnic groups. Active smoking (30.2% vs 17.7%) and obesity (20.9% vs 17.3%) were the 2 risk factors more associated with young CAD. There is a preponderance toward single vessel disease in the young CAD group, and they had a favorable clinical outcome in terms of all-cause mortality at discharge (RR 0.49 [CI 0.26-0.94]) and 1-year follow-up (RR 0.47 [CI 0.19-1.15]).

    CONCLUSION: We observed distinctive features of young CAD that would serve as a framework in the primary and secondary prevention of the early onset CAD.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  10. Ng SC, Sawatt C, Foo LK, Hitam O, Khor PG, Lee YK
    Med J Malaysia, 1996 Mar;51(1):75-9.
    PMID: 10967983
    This is a review of the first 100 coronary stents implanted for the indications of PTCA restenosis, acute or threatened closure and De Novo lesions. The success rates were high and complications rates were low. Subacute stent thrombosis rates were low and stenting for De Novo lesions in > 3.0 mm arteries provide the best short and long term results. Six months restenosis rate was low. Stent assisted high pressure balloon angioplasty is an important advance.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  11. Lee CY, Hairi NN, Wan Ahmad WA, Ismail O, Liew HB, Zambahari R, et al.
    PLoS One, 2013;8(8):e72382.
    PMID: 24015238 DOI: 10.1371/journal.pone.0072382
    To assess whether gender differences exist in the clinical presentation, angiographic severity, management and outcomes in patients with coronary artery disease (CAD).
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  12. Lee ZV, Arjan Singh RS
    Cureus, 2021 Jan 07;13(1):e12542.
    PMID: 33425567 DOI: 10.7759/cureus.12542
    Transient cortical blindness after coronary angiography has long been reported in the literature; however, this condition remains rare until today. We report a case of transient cortical blindness after coronary angiography, bypass graft angiography, and coronary angioplasty, which was deemed to be secondary to contrast agent. A 60-year-old man who underwent prior coronary artery bypass grafting (CABG) started to experience recurrence of exertional and resting chest pain one year after CABG. In addition to coronary artery disease, he has underlying type 2 diabetes mellitus, hypertension, and dyslipidemia. Due to technical reasons, he was unable to undergo a computed tomography (CT) angiography of the coronary arteries and bypass grafts. Invasive coronary and bypass graft angiography were done, followed by stenting of the left circumflex artery. Thirty minutes after completion of the procedure, the patient had bilateral blurring of vision, which worsened drastically to only being able to perceive light bilaterally. The patient otherwise did not have any other neurological deficits. Binocular indirect ophthalmoscopy revealed no significant abnormalities apart from mild non-proliferative diabetic retinopathy of the left eye. A non-contrasted CT scan of the brain revealed acute subarachnoid bleed in both occipital lobes, but a subsequent magnetic resonance imaging scan of the brain revealed no evidence of intracranial bleed. The patient's vision gradually improved eight hours after the index event, and his vision completely normalized 12 hours later. The patient was discharged well two days later, and at one-month, three-month, and six-month follow-up, the patient remained angina-free, and his vision had remained stable bilaterally.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  13. Boo YL, Liam CCK, Lim SY, Look ML
    Hong Kong Med J, 2019 Feb;25(1):74-5.
    PMID: 30713145 DOI: 10.12809/hkmj176972
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  14. Poh KK, Tan HC, Yip JW, Lim YT
    Singapore Med J, 2005 Aug;46(8):407-13.
    PMID: 16049611
    The pattern of use of abciximab in real-life clinical patients undergoing percutaneous coronary intervention (PCI) in 11 high-volume centres in Singapore, Malaysia, Thailand, Philippines, India, Pakistan and Korea was prospectively examined.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links