Displaying publications 21 - 40 of 171 in total

Abstract:
Sort:
  1. Abu Amr SS, Aziz HA, Adlan MN
    Waste Manag, 2013 Jun;33(6):1434-41.
    PMID: 23498721 DOI: 10.1016/j.wasman.2013.01.039
    The objective of this study was to investigate the performance of employing persulfate reagent in the advanced oxidation of ozone to treat stabilized landfill leachate in an ozone reactor. A central composite design (CCD) with response surface methodology (RSM) was applied to evaluate the relationships between operating variables, such as ozone and persulfate dosages, pH, and reaction time, to identify the optimum operating conditions. Quadratic models for the following four responses proved to be significant with very low probabilities (<0.0001): COD, color, NH3-N, and ozone consumption (OC). The obtained optimum conditions included a reaction time of 210 min, 30 g/m(3) ozone, 1g/1g COD0/S2O8(2-) ratio, and pH 10. The experimental results were corresponded well with predicted models (COD, color, and NH3-N removal rates of 72%, 96%, and 76%, respectively, and 0.60 (kg O3/kg COD OC). The results obtained in the stabilized leachate treatment were compared with those from other treatment processes, such as ozone only and persulfate S2O8(2-) only, to evaluate its effectiveness. The combined method (i.e., O3/S2O8(2-)) achieved higher removal efficiencies for COD, color, and NH3-N compared with other studied applications. Furthermore, the new method is more efficient than ozone/Fenton in advanced oxidation process in the treatment of the same studied leachate.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  2. Abu Amr SS, Aziz HA
    Waste Manag, 2012 Sep;32(9):1693-8.
    PMID: 22633680 DOI: 10.1016/j.wasman.2012.04.009
    Ozonation, combined with the Fenton process (O(3)/H(2)O(2)/Fe(2+)), was used to treat matured landfill leachate. The effectiveness of the Fenton molar ratio, Fenton concentration, pH variance, and reaction time were evaluated under optimum operational conditions. The optimum removal values of chemical oxygen demand (COD), color, and NH(3)-N were found to be 65%, 98%, and 12%, respectively, for 90 min of ozonation using a Fenton molar ratio of 1 at a Fenton concentration of 0.05 mol L(-1) (1700 mg/L) H(2)O(2) and 0.05 mol L(-1) (2800 mg/L) Fe(2+) at pH 7. The maximum removal of NH(3)-N was 19% at 150 min. The ozone consumption for COD removal was 0.63 kg O(3)/kg COD. To evaluate the effectiveness, the results obtained in the treatment of stabilized leachate were compared with those obtained from other treatment processes, such as ozone alone, Fenton reaction alone, as well as combined Fenton and ozone. The combined method (i.e., O(3)/H(2)O(2)/Fe(2+)) achieved higher removal efficiencies for COD, color, and NH(3)-N compared with other studied applications.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  3. Akinbile CO, Yusoff MS, Ahmad Zuki AZ
    Waste Manag, 2012 Jul;32(7):1387-93.
    PMID: 22456086 DOI: 10.1016/j.wasman.2012.03.002
    Performance evaluation of pilot scale sub-surface constructed wetlands was carried out in treating leachate from Pulau Burung Sanitary Landfill (PBSL). The constructed wetland was planted with Cyperus haspan with sand and gravel used as substrate media. The experiment was operated for three weeks retention time and during the experimentation, the influent and effluent samples were tested for its pH, turbidity, color, total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), ammonia nitrogen (NH(3)-N), Total phosphorus (TP), total nitrogen (TN) and also for heavy metals such as iron (Fe), magnesium (Mg), manganese (Mn) and zinc (Zn) concentrations. The results showed that the constructed wetlands with C. haspan were capable of removing 7.2-12.4% of pH, 39.3-86.6% of turbidity, 63.5-86.6% of color, 59.7-98.8% of TSS, 39.2-91.8% of COD, 60.8-78.7% of BOD(5), 29.8-53.8% of NH(3)-N, 59.8-99.7% of TP, 33.8-67.0% of TN, 34.9-59.0% of Fe, 29.0-75.0% of Mg, 51.2-70.5% of Mn, and 75.9-89.4% of Zn. The significance of removal was manifested in the quality of the effluent obtained at the end of the study. High removal efficiencies in the study proved that leachate could be treated effectively using subsurface constructed wetlands with C. haspan plant.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  4. Ghani ZA, Yusoff MS, Zaman NQ, Zamri MFMA, Andas J
    Waste Manag, 2017 Apr;62:177-187.
    PMID: 28274782 DOI: 10.1016/j.wasman.2017.02.026
    This study determined the optimum conditions for preparation and adsorptive treatment of landfill leachate from banana pseudo-stem based activated carbon. Response surface methodology (RSM) based on Box-Behnken was applied to optimize the combination effect of three important reaction variables, i.e. activation temperature (°C), activation time and impregnation ratio (IR). The reaction was performed via a single step activation with ZnCl2 in a closed activation system. A series of 17 individual experiments were conducted and the results showed that the RSM based on BBD is very applicable for adsorptive removal of pollutants from landfill leachate treatment. The optimum conditions obtained by Design of Experiments (DOE) was at 761°C activation temperature, 87min activation time and 4.5g/g impregnation ratio with product yield (27%), iodine number (1101mg/g), color removal (91.2%) and COD removal (83.0%).
    Matched MeSH terms: Biological Oxygen Demand Analysis
  5. Ishak AR, Hamid FS, Mohamad S, Tay KS
    Waste Manag, 2018 Jun;76:575-581.
    PMID: 29503052 DOI: 10.1016/j.wasman.2018.02.047
    In this work, the feasibility of coagulation-flocculation coupled with UV-based sulfate radical oxidation process (UV/SRAOP) in the removal of chemical oxygen demand (COD) of stabilized landfill leachate (SLL) was evaluated. For coagulation-flocculation, ferric chloride (FeCl3) was used as the coagulant. The effect of initial pH of SLL and COD:FeCl3 ratio on the COD removal was evaluated. The result revealed that COD:FeCl3 ratio of 1:1.3 effectively removed 76.9% of COD at pH 6. The pre-treated SLL was then subjected to UV/SRAOP treatment. For UV/SRAOP, the sulfate radical (SR) was generated using UV-activated persulfate (UV/PS) and peroxymonosulfate (UV/PMS). The dosage of oxidant and reaction time were found to be the main parameters that influence the efficiency of COD removal. On the other hand, the effect of initial pH (3-7) and the type of oxidant (PS and PMS) was found to have no significant influence on COD removal efficiency. At optimum conditions, approximately 90.9 and 91.5% of COD was successfully removed by coagulation-flocculation coupled with UV/PS and UV/PMS system, respectively. Ecotoxicity study using zebrafish showed a reduction in toxicity of SLL from 10.1 to 1.74 toxicity unit (TU) after coagulation-flocculation. The TU remained unchanged after UV/PS treatment but slightly increased to 1.80 after UV/PMS treatment due to the presence of residual sulfate ion in the treated effluent. In general, it can be concluded that coagulation-flocculation coupled with UV/SRAOP could be a potential water treatment method for SLL treatment.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  6. Alslaibi TM, Abustan I, Mogheir YK, Afifi S
    Waste Manag Res, 2013 Jan;31(1):50-9.
    PMID: 23148014 DOI: 10.1177/0734242X12465462
    Landfills are a source of groundwater pollution in Gaza Strip. This study focused on Deir Al Balah landfill, which is a unique sanitary landfill site in Gaza Strip (i.e., it has a lining system and a leachate recirculation system). The objective of this article is to assess the generated leachate quantity and percolation to the groundwater aquifer at a specific site, using the approaches of (i) the hydrologic evaluation of landfill performance model (HELP) and (ii) the water balance method (WBM). The results show that when using the HELP model, the average volume of leachate discharged from Deir Al Balah landfill during the period 1997 to 2007 was around, 6800 m3/year. Meanwhile, the average volume of leachate percolated through the clay layer was 550 m3/year, which represents around 8% of the generated leachate. Meanwhile, the WBM indicated that the average volume of leachate discharged from Deir Al Balah landfill during the same period was around 7660 m3/year--about half of which comes from the moisture content of the waste, while the remainder comes from the infiltration of precipitation and re-circulated leachate. Therefore, the estimated quantity of leachate to groundwater by these two methods was very close. However, compared with the measured leachate quantity, these results were overestimated and indicated a dangerous threat to the groundwater aquifer, as there was no separation between municipal, hazardous and industrial wastes, in the area.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  7. Ahmed Z, Yusoff MS, Kamal NHM, Aziz HA
    Waste Manag Res, 2021 Nov;39(11):1396-1405.
    PMID: 33928820 DOI: 10.1177/0734242X211012775
    The removal of concentrated colour (around 5039 Pt-Co) and chemical oxygen demand (COD; around 4142 mg L-1) from matured landfill leachate through a novel combination of humic acid extraction and coagulation with natural oil palm trunk starch (OPTS) was investigated in this study. Central composite design from response surface methodology of Design Expert-10 software executed the experimental design to correlate experimental factors with desired responses. Analysis of variance developed the quadratic model for four factors (e.g. coagulant dosage, slow mixing speed and time and centrifugation duration) and two responses (% removal of colour, COD). The model confirmed the highest colour (84.96%) and COD (48.84%) removal with a desirability function of 0.836 at the optimum condition of 1.68 g L-1 coagulant dose, 19.11 rpm slow mixing speed, 16.43 minutes for mixing time and 35.75 minutes for centrifugation duration. Better results of correlation coefficient (R2 = 0.98 and 0.96) and predicted R2 (0.94 and 0.84) indicates the model significance. Electron microscopic images display the amalgamation of flocs through bridging. Fourier transforms infrared spectra confirmed the existence of selected organic groups in OPTS, which eventually signifies the applied method.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  8. Ahmed Z, Yusoff MS, Kamal NHM, Aziz HA
    Waste Manag Res, 2023 Oct;41(10):1584-1593.
    PMID: 37154233 DOI: 10.1177/0734242X231160687
    Heterogeneous combinations of organic compounds (humic acid (HA) and fulvic acid) are the prime factor for the high concentration of colour and chemical oxygen demand (COD) in semi-aerobic stabilized landfill leachate. These organics are less biodegradable and cause a severe threat to environmental elements. Microfiltration and centrifugation processes were applied in this study to investigate the HA removal from stabilized leachate samples and its corresponding interference with COD and colour. The three-stage extraction process recovered a maximum of 1412 ± 2.5 mg/L (Pulau Burung landfill site (PBLS) leachate), 1510 ± 1.5 mg/L (Alor Pongsu landfill site (APLS leachate) at pH 1.5 and 1371 ± 2.5 mg/L (PBLS) and 1451 ± 1.5 mg/L (APLS) of HA (about 42% of the total COD concentration) at pH 2.5, which eventually indicates the process efficiency. Comparative characteristics analysis of recovered HA by scanning electron microscopy, energy-dispersive X-ray, X-ray photoelectron spectroscopy, and Fourier transform infrared significantly indicate the existence of identical elements in the recovered HA compared with the previous studies. The higher reduction (around 37%) in ultraviolet (UV) absorbance values (UV254 and UV280) in the final effluent indicates the elimination of aromaticity and conjugated double-bond compounds from leachate. Moreover, 36 and 39% COD and 39 and 44% colour removal exhibit substantial interference.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  9. Manickam S, Abidin Nb, Parthasarathy S, Alzorqi I, Ng EH, Tiong TJ, et al.
    Ultrason Sonochem, 2014 Jul;21(4):1519-26.
    PMID: 24485395 DOI: 10.1016/j.ultsonch.2014.01.002
    Palm oil mill effluent (POME) is a highly contaminating wastewater due to its high chemical oxygen demand (COD) and biochemical oxygen demand (BOD). Conventional treatment methods require longer residence time (10-15 days) and higher operating cost. Owing to this, finding a suitable and efficient method for the treatment of POME is crucial. In this investigation, ultrasound cavitation technology has been used as an alternative technique to treat POME. Cavitation is the phenomenon of formation, growth and collapse of bubbles in a liquid. The end process of collapse leads to intense conditions of temperature and pressure and shock waves which assist various physical and chemical transformations. Two different ultrasound systems i.e. ultrasonic bath (37 kHz) and a hexagonal triple frequency ultrasonic reactor (28, 40 and 70 kHz) of 15 L have been used. The results showed a fluctuating COD pattern (in between 45,000 and 60,000 mg/L) while using ultrasound bath alone, whereas a non-fluctuating COD pattern with a final COD of 27,000 mg/L was achieved when hydrogen peroxide was introduced. Similarly for the triple frequency ultrasound reactor, coupling all the three frequencies resulted into a final COD of 41,300 mg/L compared to any other individual or combination of two frequencies. With the possibility of larger and continuous ultrasonic cavitational reactors, it is believed that this could be a promising and a fruitful green process engineering technique for the treatment of POME.
    Matched MeSH terms: Biological Oxygen Demand Analysis*
  10. Ishadi NA, Rawi CS, Ahmad AH, Abdul NH
    Trop Life Sci Res, 2014 Dec;25(2):61-79.
    PMID: 27073600 MyJurnal
    The hemipteran (Insecta) diversity in the upper part of the Kerian River Basin was low with only 8 families and 16 genera recorded at 4 study sites from 3 rivers. Water bug composition varied among sampling sites (Kruskal-Wallis χ (2) = 0.00, p<0.05) but was not affected by wet-dry seasons (Z = 0.00, p>0.05). All recorded water parameters were weakly associated with generic abundance but the biochemical oxygen demand (BOD), chemical oxygen demand (COD), Water Quality Index (WQI) and heavy metals (zinc and manganese) showed relatively strong positive or negative relations with hemipteran diversity and richness (H' and R2). Within the ranges of measured water parameters, the WQI was negatively associated with hemipteran diversity and richness, implying the tolerance of the water bugs to the level of pollution encountered in the river basin. Based on its highest abundance and occurrence (ISI), Rhagovelia was the most important genus and along with Rheumatogonus and Paraplea, these genera were common at all study sites. In conclusion, habitat availability and suitability together with some environmental parameters influenced the abundance and composition of hemipterans in this river basin.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  11. Rosli NRM, Yahya K
    Trop Life Sci Res, 2017 Jul;28(2):189-199.
    PMID: 28890770 MyJurnal DOI: 10.21315/tlsr2017.28.2.14
    The study of river water quality plays an important role in assessing the pollution status and health of the water bodies. Human-induced activities such as domestic activities, aquaculture, agriculture and industries have detrimentally affected the river water quality. Pinang River is one of the important rivers in Balik Pulau District that supplies freshwater for human consumption. A total of 442 physical and chemical parameters data of the Pinang River, Balik Pulau catchment were analysed to determine the sources of pollutants entering the river. Non-supervised artificial neural network (ANN) was employed to classify and cluster the river into upstream, middle-stream and downstream zones. The monitored data and non-supervised ANN analysis demonstrated that the source of nitrate was derived from the upper part of the Pinang River, Balik Pulau while the sources of nitrite, ammonia and ortho-phosphate are predominant at the middle-stream of the river system. Meanwhile, the sources of high total suspended solid and biological oxygen demand were concentrated at the downstream of the river.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  12. Keng TS, Samsudin MFR, Sufian S
    Sci Total Environ, 2021 Mar 10;759:143489.
    PMID: 33248782 DOI: 10.1016/j.scitotenv.2020.143489
    Assessment of the treatment performance in the field-scale hybrid constructed wetland (CW) for ammonia manufacturing plant remains limited. After being in operations running on and off since 2014, the hybrid CW which treats effluent from the ammonia manufacturing plant in Peninsular, Malaysia has recently demonstrated the full clogging to the CW. It takes only 8 months to demonstrate a big deterioration of performance in 2019. Though the mechanism of clogging is not clear, which can be partially from inherent design problems or operational issues, nonetheless, it is important to evaluate how this clogging has impacted the effluent treatment performance and the continuous utilization of the CW. The purpose of this study is to evaluate the impact of the treatment performance on the ammoniacal nitrogen and COD removal when the CW is clogged. The result revealed that there is no impact on COD removal, but it has a substantial impact on the ammoniacal nitrogen removal. The ammoniacal nitrogen removal dropped to negative (outlet concentration is higher than inlet concentration) during the clogged period. Another observation is, the low removal rate also coincides with a high COD/N ratio, when the COD/N ratio increased to >2, the ammoniacal nitrogen removal rate dropped substantially, with the coefficient of determination, R2 of 40.5%. The root cause for the clogging to develop in a short period of time is unidentified. However, it is still worth noting that COD and ammoniacal nitrogen efficiency did not behave the same at the clogged CW.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  13. How SW, Chua ASM, Ngoh GC, Nittami T, Curtis TP
    Sci Total Environ, 2019 Nov 25;693:133526.
    PMID: 31376760 DOI: 10.1016/j.scitotenv.2019.07.332
    Many wastewater treatment plants (WWTPs) operating in biological nitrogen removal activated sludge process in the tropics are facing the pressure of increasingly stringent effluent standards while seeking solutions to reduce the plants' energy consumption and operating cost. This study investigated the feasibility of applying low-dissolved oxygen (low-DO) nitrification and utilizing slowly-biodegradable chemical oxygen demand (sbCOD) for denitrification, which helps to reduce energy usage and operating cost in treating low soluble COD-to-nitrogen tropical wastewater. The tropical wastewater was first characterized using wastewater fractionation and respirometry batch tests. Then, a lab-scale sequencing batch reactor (SBR) was operated to evaluate the long-term stability of low-DO nitrification and utilizing sbCOD for denitrification in an anoxic-oxic (AO) process treating tropical wastewater. The wastewater fractionation experiment revealed that particulate settleable solids (PSS) in the wastewater provided slowly-biodegradable COD (sbCOD), which made up the major part (51 ± 10%) of the total COD. The PSS hydrolysis rate constant at tropical temperature (30 °C) was 2.5 times higher than that at 20 °C, suggesting that sbCOD may be utilized for denitrification. During the SBR operation, high nitrification efficiency (93 ± 6%) was attained at low-DO condition (0.9 ± 0.1 mg O2/L). Utilizing sbCOD for post-anoxic denitrification in the SBR reduced the effluent nitrate concentration. Quantitative polymerase chain reaction, 16S rRNA amplicon sequencing and fluorescence in-situ hybridization revealed that the genus Nitrospira was a dominant nitrifier. 16S rRNA amplicon sequencing result suggested that 50% of the Nitrospira-related operational taxonomic units were affiliated with comammox, which may imply that the low-DO condition and the warm wastewater promoted their growth. The nitrogen removal in a tropical AO process was enhanced by incorporating low-DO nitrification and utilizing sbCOD for post-anoxic denitrification, which contributes to an improved energy sustainability of WWTPs.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  14. Pak HY, Chuah CJ, Yong EL, Snyder SA
    Sci Total Environ, 2021 Aug 01;780:146661.
    PMID: 34030308 DOI: 10.1016/j.scitotenv.2021.146661
    Land use plays a significant role in determining the spatial patterns of water quality in the Johor River Basin (JRB), Malaysia. In the recent years, there have been several occurrences of pollution in these rivers, which has generated concerns over the long-term sustainability of the water resources in the JRB. Specifically, this water resource is a shared commodity between two states, namely, Johor state of Malaysia and Singapore, a neighbouring country adjacent to Malaysia. Prior to this study, few research on the influence of land use configuration on water quality have been conducted in Johor. In addition, it is also unclear how water quality varies under different seasonality in the presence of point sources. In this study, we investigated the influence of land use and point sources from wastewater treatment plants (WWTPs) on the water quality in the JRB. Two statistical techniques - Multivariate Linear Regression (MLR) and Redundancy Analysis (RA) were undertaken to analyse the relationships between river water quality and land use configuration, as well as point sources from WWTPs under different seasonality. Water samples were collected from 49 sites within the JRB from March to December in 2019. Results showed that influence from WWTPs on water quality was greater during the dry season and less significant during the wet season. In particular, point source was highly positively correlated with ammoniacal‑nitrogen (NH3-N). On the other hand, land use influence was greater than point source influence during the wet season. Residential and urban land use were important predictors for nutrients and organic matter (chemical oxygen demand); and forest land use were important sinks for heavy metals but a significant source of manganese.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  15. Ansari M, Othman F, El-Shafie A
    Sci Total Environ, 2020 Jun 20;722:137878.
    PMID: 32199382 DOI: 10.1016/j.scitotenv.2020.137878
    Sewage treatment plants (STPs) keep sewage contamination within safe levels and minimize the risk of environmental disasters. To achieve optimum operation of an STP, it is necessary for influent parameters to be measured or estimated precisely. In this research, six well-known influent chemical and biological characteristics, i.e., biochemical oxygen demand (BOD), chemical oxygen demand (COD), Ammoniacal Nitrogen (NH3-N), pH, oil and grease (OG) and suspended solids (SS), were modeled and predicted using the Sugeno fuzzy logic model. The membership function range of the fuzzy model was optimized by ANFIS, the integrated Genetic algorithms (GA), and the integrated particle swarm optimization (PSO) algorithms. The results were evaluated by different indices to find the accuracy of each algorithm. To ensure prediction accuracy, outliers in the predicted data were found and replaced with reasonable values. The results showed that both integrated GA-FIS and PSO-FIS algorithms performed at almost the same level and both had fewer errors than ANFIS. As the GA-FIS algorithm predicts BOD with fewer errors than PSO-FIS and the aim of this study is to provide an accurate prediction of missing data, GA-FIS was only used to predict the BOD parameter; the other parameters were predicted by PSO-FIS algorithm. As a result, the model successfully could provide outstanding performance for predicting the BOD, COD, NH3-N, OG, pH and SS with MAE equal to 3.79, 5.14, 0.4, 0.27, 0.02, and 3.16, respectively.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  16. Oon YL, Ong SA, Ho LN, Wong YS, Dahalan FA, Oon YS, et al.
    Sci Total Environ, 2020 Jun 10;720:137370.
    PMID: 32325554 DOI: 10.1016/j.scitotenv.2020.137370
    Complete degradation of azo dye has always been a challenge due to the refractory nature of azo dye. An innovative hybrid system, constructed wetland-microbial fuel cell (CW-MFC) was developed for simultaneous azo dye remediation and energy recovery. This study investigated the effect of circuit connection and the influence of azo dye molecular structures on the degradation rate of azo dye and bioelectricity generation. The closed circuit system exhibited higher chemical oxygen demand (COD) removal and decolourisation efficiencies compared to the open circuit system. The wastewater treatment performances of different operating systems were ranked in the decreasing order of CW-MFC (R1 planted-closed circuit) > MFC (R2 plant-free-closed circuit) > CW (R1 planted-open circuit) > bioreactor (R2 plant-free-open circuit). The highest decolourisation rate was achieved by Acid Red 18 (AR18), 96%, followed by Acid Orange 7 (AO7), 67% and Congo Red (CR), 60%. The voltage outputs of the three azo dyes were ranked in the decreasing order of AR18 > AO7 > CR. The results disclosed that the decolourisation performance was significantly influenced by the azo dye structure and the moieties at the proximity of azo bond; the naphthol type azo dye with a lower number of azo bond and more electron-withdrawing groups could cause azo bond to be more electrophilic and more reductive for decolourisation. Moreover, the degradation pathway of AR18, AO7 and CR were elucidated based on the respective dye intermediate products identified through UV-Vis spectrophotometry, high-performance liquid chromatography (HPLC), and gas chromatograph-mass spectrometer (GC-MS) analyses. The CW-MFC system demonstrated high capability of decolouring azo dyes at the anaerobic anodic region and further mineralising dye intermediates at the aerobic cathodic region to less harmful or non-toxic products.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  17. Chong SS, Aziz AR, Harun SW
    Sensors (Basel), 2013 Jul 05;13(7):8640-68.
    PMID: 23881131 DOI: 10.3390/s130708640
    Demand for online and real-time measurements techniques to meet environmental regulation and treatment compliance are increasing. However the conventional techniques, which involve scheduled sampling and chemical analysis can be expensive and time consuming. Therefore cheaper and faster alternatives to monitor wastewater characteristics are required as alternatives to conventional methods. This paper reviews existing conventional techniques and optical and fibre optic sensors to determine selected wastewater characteristics which are colour, Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). The review confirms that with appropriate configuration, calibration and fibre features the parameters can be determined with accuracy comparable to conventional method. With more research in this area, the potential for using FOS for online and real-time measurement of more wastewater parameters for various types of industrial effluent are promising.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  18. Siti Roshayu Hassan, Nastaein Qamaruz Zaman, Irvan Dahlan
    MyJurnal
    The performance and operational characteristics of a laboratory scale modified anaerobic hybrid baffled (MAHB) reactor were studied using recycled paper mill effluent (RPME) wastewater. MAHB reactor was continuously operated at 35°C for 90 days with organic loading rate (OLR) increased from 0.14 to 0.57 g/L/dy. This present study demonstrated that the system was proficient in treating low strength RPME wastewater. Highest carbon oxygen demand (COD) removal were recorded up to 97% for an organic loading of 0.57 g /L/dy while effluent alkalinity assured that the system pH in the MAHB compartments were of great advantages to acidogens and methanogens respectively. Methane and biogas production rate shows increment as the load increases, which evidently indicated that the most significant approach to enhance gas production rates involves the increment of incoming substrate moderately. Variations of biogas and volatile fatty acid (VFA) in different compartments of MAHB reactor indicated the chronological degradation of substrate. The compartmental structure of MAHB reactor provided its strong ability to resist shock loads. From this present study, it shows the potential usage of MAHB reactor broadens the usage of multi-phase anaerobic technology for industrial wastewater treatment.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  19. Nor Habibah Mohd Rosli, Wan Azlina Ahmad
    Science Letters, 2018;12(1):30-43.
    MyJurnal
    Wastewater from industrial plants such as textile, electroplating and petroleum refineries contains various substances that tend to increase the chemical oxygen demand (COD) of the wastewater. Therefore, it is desired to develop a process suitable for treating the wastewater to meet the regulatory limits. This work was conducted to investigate the potential of adapted single culture of A. baumannii, A.calcoaceticus and C.cellulans in reducing COD in real textile wastewater. The study was carried out by adapting each single culture (10% inoculums) to increasing concentration (1%, 2.5 %, 5%, 7.5 % and 10%) of textile wastewater. Then it was introduced to the textile effluent without pH adjustment for five days and the COD values were measured. The textile wastewater was supplemented with pineapple waste for bacterial growth and metabolism. Results obtained showed that pineapple waste was a good nutrient supply for the growth of the bacteria and the best concentration of textile wastewater for adaptation was at 2.5%. The results also showed that A.calcoaceticus shows highest COD reduction with 67% removal whereas A. baumannii and C.cellulans with 60% and 58% removal respectively. The outcome supported that the single culture used in this study showed considerably high reduction of COD from real textile wastewater.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  20. Sangyoka S, Poomipuk N, Reungsang A
    Sains Malaysiana, 2012;41:1211-1216.
    The Cassava starch manufacturing wastewater (CSW) was used as a substrate to produce polyhydroxybutyrate (PHB) by Cupriavidus sp. KKU38. The acidogenic fermentation process of CSW was first conducted to obtain volatile fatty acids (VFAs), which are more efficient in PHB production than raw CSW. The effect on substrate concentration and nutrients, i.e. nitrogen and phosphorus concentrations, by means of chemical oxygen demand: nitrogen: phosphorus ratio (COD:N:P ratio) variation was investigated. The results indicated that PHB production from fermented CSW by Cupriavidus sp. KKU38 was optimized at the soluble COD:N:P ratio of 100:0.5:11. This ratio gave the maximum PHB content and yield of 85.53% and 0.31 g PHB/g COD consumed, respectively. By using the proposed PHB production process, the potential to produce 0.19 kg of PHB from 1.0 kg of soluble chemical oxygen demand (sCOD) contained in CSW was exhibited. The relatively high COD removal efficiency of 73.82% at the optimal condition could be achieved, which demonstrated the concept of water quality improvements alongside the production of the value-added by-product, PHB.
    Matched MeSH terms: Biological Oxygen Demand Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links