Displaying publications 21 - 34 of 34 in total

Abstract:
Sort:
  1. Kow, Ren Yi, Aziah Abdul Aziz, Muhammad Firdaus Abas, Low, Chooi Leng, Akmal Azim Ahmad Alwi
    MyJurnal
    The human foot serves as an important part to support
    the body weight and accounts for the majority of our
    movements. A mangled limb involves injury to at least
    three out of four systems, namely the soft tissues, nerves,
    blood supply and bone. While amputation is indicated in
    some cases of mangled limb, with proper planning, limb
    salvaging surgical management is also a viable option.
    Special consideration to the skeletal stabilization, control
    of infection, vascular status and soft tissue coverage is
    paramount to the success of limb salvaging surgery. We
    present a case of mangled limb which was successfully
    treated with limb salvaging surgical management. Initial
    debridement, Kirschner wires insertion and cross ankle
    external fixation were used for skeletal stabilization. An
    antibiotic spacer was inserted for local antibiotic and to
    maintain the length left due to the loss of medial and
    intermediate cuneiform bones. The anterior tibialis
    artery and its venae comitantes were utilized for free
    vascularized fibular graft to provide bony reconstruction
    as well as soft tissue coverage for the mangled foot.
    Matched MeSH terms: Bone Wires
  2. Kow RY, Mustapha Zakaria Z, Khan ESKM, Low C
    J Orthop Case Rep, 2019 3 28;8(6):65-67.
    PMID: 30915298 DOI: 10.13107/jocr.2250-0685.1262
    Introduction: Fracture of the ulnar coronoid process is uncommon. It is commonly associated with posterior dislocation of the elbow, but it may also present as an isolated fracture. In general, all ulnar coronoid process fractures with elbow joint instability and large fracture fragments are fixed surgically. We report two cases of the rare isolated Regan-Morrey type III ulnar coronoid process fractures and their outcomes.

    Case Report: Case Report 1: Mrs P, a 27-year-old right-hand dominant female, was involved in a motor vehicle accident (MVA) and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. In view of the large coronoid process fragment causing elbow joint instability, she underwent an open reduction and internal fixation when the elbow swelling had subsided. An anterior approach was used to identify the fracture fragment and it was fixed with two half-threaded cancellous lag screws with washers to achieve an anatomical reduction. Postoperatively, she recovered with excellent outcome based on the Mayo elbow performance score (MEPS).Case Report 2: Mr M, a 23-year-old right-hand dominant gentleman, was involved in a MVA and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. During examination under general anesthesia, passive range of the movement of his right elbow was noted to be <90°due to the impaction of the fracture fragment. An open reduction through an anterior approach was performed and Kirschner wires were inserted to fix the coronoid process fracture. Kirschner wires were opted for the ease of post-operative removal as the patient was not keen to have a retained implant after recovery. He recovered with good outcome based on the MEPS.

    Conclusion: Isolated fracture of the ulnar coronoid process is rare. Open reduction and internal fixation is mandatory for patients with coronoid process fracture and unstable elbow joint to achieve good functional outcomes.

    Matched MeSH terms: Bone Wires
  3. Miswan MF, Singh VA, Yasin NF
    Ulus Travma Acil Cerrahi Derg, 2011 Nov;17(6):504-8.
    PMID: 22290002 DOI: 10.5505/tjtes.2011.04809
    We reviewed cases with Lisfranc injuries who presented to our center in order to study the adequacy of the treatment method and their final functional outcome.
    Matched MeSH terms: Bone Wires*
  4. Ramzisham AR, Raflis AR, Khairulasri MG, Ooi Su Min J, Fikri AM, Zamrin MD
    Asian Cardiovasc Thorac Ann, 2009 Dec;17(6):587-91.
    PMID: 20026533 DOI: 10.1177/0218492309348948
    Sternal dehiscence is a rare but devastating complication following median sternotomy for cardiac surgery. The optimal technique for sternal closure is unclear. We conducted this prospective randomized trial to compare the incidence of sternal dehiscence after figure-of-8 and simple interrupted suturing in patients undergoing coronary artery bypass grafting. Between January 2007 and June 2008, 98 patients had figure-of-8 suturing and 97 had interrupted sutures. The mean age of the patients was 60.9 +/- 7.6 years. The overall sternal dehiscence rate was 8%; 7 cases in the in figure-of-8 group and 9 in the interrupted group. Thirteen patients had no wound infection and healed with conservative treatment. Only 3 patients had sternal dehiscence with infection: 2 with simple interrupted closure and 1 with figure-of-8 sternal closure. There was no significant difference in rates of sternal dehiscence between the 2 groups. It was concluded that figure-of-8 sternal suturing is equally effective as simple interrupted suturing in preventing sternal dehiscence.
    Matched MeSH terms: Bone Wires*
  5. Saw A, Chan CK, Penafort R, Sengupta S
    Med J Malaysia, 2006 Feb;61 Suppl A:62-5.
    PMID: 17042233
    Patients treated with external fixation for limb reconsturciton or fracture stabilization equire regular and prolongedperiod of pin-tract care involving frequent visits to clinic and dressing traditionally carried out by trained nurses or medical assistants. A simple method of do-it-yourself dressing was introduced in our institution and this study was undertaken to evaluate the effectiveness of the protocol. Sixty patients (40 trauma-related problems and 20 congenital or developmental disorders) were enrolled into the study. Following application of external fixation, the patients and/or their caretakers were taught on how to do pin-site dressing using normal saline or drinking water as cleansing solution on daily basis. Patients were discharged on the second or third post-operative day and were followed-up every two weeks for an average 182 days (range 66 to 379 days) with special attention on identifying pin-tract infection. A simple grading system for pin-tract infections was proposed. Of 40 patients with trauma-related problems. 65% were post-traumatic infections. There were 788 metal-skin interfaces (239 half-pin fixations and 549 tensioned wire fixations. A total 143 metal-skin interface infections (18.1%) involving half-pin sites (41.3%) and tensioned wire sites (58.7%) was noted. Majority were grade I infections (79.7%), 18.8% grade II and only 1.4% grade III. Most infections (81%)were caused by Staphylococcus aureus. Grade I infections were successfully treated with frequent dressing, grade II by adjunctive oral antibiotic but grade III infections required removal of fixator. All eventually healed. Do yourself non-sterile dressing of metal-skin interfaces is a cost-effective method of pin-site care with a low infection rate. The infections were sucessfully treated using guidelines according to the proposed classification of pin-tract infections.
    Matched MeSH terms: Bone Wires/microbiology
  6. Alhalawani AM, Towler MR
    J Biomater Appl, 2013 Nov;28(4):483-97.
    PMID: 23812580 DOI: 10.1177/0885328213495426
    Sternotomy and sternal closure occur prior to and post cardiac surgery, respectively. Although post-operative complications associated with poor sternal fixation can result in morbidity, mortality, and considerable resource utilization, sternotomy is preferred over other methods such as lateral thoracotomy. Rigid sternal fixation is associated with stability and reduced incidence of post-operative complications. This is a comprehensive review of the literature evaluating in vivo, in vitro, and clinical responses to applying commercial and experimental surgical tools for sternal fixation after median sternotomy. Wiring, interlocking, plate-screw, and cementation techniques have been examined for closure, but none have experienced widespread adoption. Although all techniques have their advantages, serious post-operative complications were associated with the use of wiring and/or plating techniques in high-risk patients. A fraction of studies have analyzed the use of sternal interlocking systems and only a single study analyzed the effect of using kryptonite cement with wires. Plating and interlocking techniques are superior to wiring in terms of stability and reduced rate of post-operative complications; however, further clinical studies and long-term follow-up are required. The ideal sternal closure should ensure stability, reduced rate of post-operative complications, and a short hospitalization period, alongside cost-effectiveness.
    Matched MeSH terms: Bone Wires
  7. Marwan M, Ibrahim M
    Injury, 1999 Jun;30(5):333-5.
    PMID: 10505126
    A simple technique for removal of the distal fragment of the broken intramedullary interlocking nail is described. It was successfully used in three patients with a broken nail due to nonunion. The technique requires only cerclage wire, which is available in any operating room, avoiding the difficulties obtaining the custom made hook and of excessive exposure to radiation.
    Matched MeSH terms: Bone Wires
  8. Syurahbil AH, Munajat I, Mohd EF, Hadizie D, Salim AA
    Malays Orthop J, 2020 Jul;14(2):28-38.
    PMID: 32983375 DOI: 10.5704/MOJ.2007.008
    Introduction: Redisplacement following fracture reduction is a known sequela during the casting period in children treated for distal radius fracture. Kirschner wire pinning can be alternatively used to maintain the reduction during fracture healing. This study was conducted to compare the outcomes at skeletal maturity of distal radius fractures in children treated with a cast alone or together with a Kirschner wire transfixation.

    Material and Methods: This was a retrospective study involving 57 children with metaphyseal and physeal fractures of the distal radius. There were 30 patients with metaphyseal fractures, 19 were casted, and 11 were wire transfixed. There were 27 patients with physeal fractures, 19 were treated with a cast alone, and the remaining eight underwent pinning with Kirschner wires. All were evaluated clinically, and radiologically, and their overall outcome assessed according to the scoring system, at or after skeletal maturity, at the mean follow-up of 6.5 years (3.0 to 9.0 years).

    Results: In the metaphysis group, patients treated with wire fixation had a restriction in wrist palmar flexion (p=0.04) compared with patients treated with a cast. There was no radiological difference between cast and wire fixation in the metaphysis group. In the physis group, restriction of motion was found in both dorsiflexion (p=0.04) and palmar flexion (p=0.01) in patients treated with wire fixation. There was a statistically significant difference in radial inclination (p=0.01) and dorsal tilt (p=0.03) between cast and wire fixation in physis group with a more increased radial inclination in wire fixation and a more dorsal tilt in patients treated with a cast. All patients were pain-free except one (5.3%) in the physis group who had only mild pain. Overall outcomes at skeletal maturity were excellent and good in all patients. Grip strength showed no statistical difference in all groups. Complications of wire fixation included radial physeal arrests, pin site infection and numbness.

    Conclusion: Cast and wire fixation showed excellent and good outcomes at skeletal maturity in children with previous distal radius fracture involving both metaphysis and physis. We would recommend that children who are still having at least two years of growth remaining be treated with a cast alone following a reduction unless there is a persistent unacceptable reduction warranting a wire fixation. The site of the fracture and the type of treatment have no influence on the grip strength at skeletal maturity.

    Matched MeSH terms: Bone Wires
  9. Syed J, Zamri AR, Jamaluddin S, Ruben JK, Gopindran M
    Malays Orthop J, 2017 Mar;11(1):82-84.
    PMID: 28435584 MyJurnal DOI: 10.5704/MOJ.1703.016
    Traumatic elbow dislocations in children are rare but most of them are complex dislocations, and in such dislocations, medial humerus epicondyle fractureis the most common associated injury. Fracture incarceration in the elbow joint occurs in 5-18% of medial humerus epicondyle fractures but ulnar neuropraxia is very rare. Open reduction internal fixation is indicated in medial humerus epicondyle fracture with fracture incarceration, ulnar neuropraxia, marked instability or open fracture. Operative treatment options include fragment excision and sutures, closed or open reduction and Kirschner wire fixation, open reduction and suture fixation, open reduction and smooth pin fixation, and open reduction and screw fixation. However, ulnar nerve transposition is debatable as good outcome had been reported with and without nerve transposition. We report a case of a 13-year old boy, who presented with right elbow dislocation and intra-articular entrapment of medial humerus epicondyle fracture fragment, complicated with sensory ulnar neuropraxia, following a fall onto his right outstretched hand in a motor vehicle accident. The elbow joint was reduced using close manipulative reduction but the fracture fragment remained entrapped post-reduction. The patient then underwent open reduction and screw fixation of the medial humerus epicondyle fracture without ulnar nerve transposition. He had good functional outcome six weeks after surgical intervention, with complete recovery of ulnar neuropraxia six months later. Currently, he is doing well at school and is active with his sporting activity.
    Matched MeSH terms: Bone Wires
  10. Yeak RD, Daud H, Nizlan NM
    Chin J Traumatol, 2019 Jun;22(3):182-185.
    PMID: 31060897 DOI: 10.1016/j.cjtee.2019.03.004
    Acromioclavicular joint (ACJ) injury is a common shoulder injury. There are various techniques of ACJ reconstruction. Superficial infection after ACJ reconstruction is not an uncommon complication. However, osteomyelitis post ACJ reconstruction has never been highlighted as a possible complication. Our patient is a 31-year-old male who sustained a Rockwood 5 ACJ dislocation and had anatomical ACJ reconstruction with autogenous gracilis and semitendinosus graft. Our technique involved the anatomical reconstruction of the ACJ and the coracoclavicular ligament with the usage of two bioscrews and the temporary stabilisation of the ACJ with two k-wires. As in any orthopaedic surgery, infection is often disastrous especially when the surgery involves implants. It can be disastrous with high morbidity to the patient as well as a costly complication to treat. Therefore, we wish to highlight this case as despite its rarity, osteomyelitis can be devastating to the patient and should be prevented if possible.
    Matched MeSH terms: Bone Wires/adverse effects
  11. Ong AH, Siar CH
    Aust Dent J, 1998 Aug;43(4):229-33.
    PMID: 9775467
    The cemento-ossifying fibroma is classified as an osteogenic neoplasm of the jaws. It commonly presents as a progressively growing lesion that can attain an enormous size with resultant deformity if left untreated. A case of a large cemento-ossifying fibroma involving the left mandible is described in a 15 year old male patient. The clinical, radiographic and histological features as well as surgical findings are presented. The treatment of choice of this lesion is also emphasized. Two years after surgery, there was no evidence of recurrence and the transosseous wire used to immobilize the fracture was found to be completely buried in the jaw bone.
    Matched MeSH terms: Bone Wires
  12. Hashim S, Chin LY, Krishnasamy S, Sthaneswar P, Raja Mokhtar RA
    J Cardiothorac Surg, 2015;10:32.
    PMID: 25890367 DOI: 10.1186/s13019-015-0230-0
    Recently a biocompatible bone adhesive was introduced in addition to the sternal wires to expedite sternal union and improve patient recovery. In this study we aim to objectively assess the biomarker of pain in patient who received the biocompatible bone adhesive.
    Matched MeSH terms: Bone Wires
  13. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Bone Wires
  14. Khademolhosseini M, Abd Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 Mar;22(2):123-6.
    PMID: 23222035 DOI: 10.1097/BPB.0b013e32835b2e14
    A retrospective study of nerve injuries with displaced supracondylar fractures of the humerus in children younger than 12 years of age, treated in Hospital Universiti Kebangsaan Malaysia. Our objectives were to determine the incidence of primary and iatrogenic nerve injuries in supracondylar humerus fractures Gartland types II and III and to determine the outcome of nerve recovery. A total of 272 patients with displaced supracondylar humerus fractures who required admission to Hospital Universiti Kebangsaan Malaysia from January 2000 to December 2007 were reviewed. There were 182 boys (67%) and 90 girls (33%). The mean age was 6.0 years, ranging from 1 to 12 years. Of 272 supracondylar fractures, 79 were type II and 193 were type III. Fifty-one (19%) patients had closed reduction, 160 (59%) had closed reduction and percutaneous crossed Kirschner (K) wires, and 61 (22%) had open reduction and crossed K-wires. Associated nerve injuries involving the median, radial, and ulnar nerves were observed in 48 (18%) patients. Nerve injuries were observed in nine (3%) patients upon admission. Thirty-nine (14%) patients developed nerve injuries following treatment. Of these 39 patients, 34 had ulnar, three had radial, and two had median nerve injuries. Nerve exploration was performed in five patients (in four patients following debridement of open fracture and in one because of unacceptable postoperative radiographs, and they subsequently underwent open reduction and exploration). Except for these five patients, the K-wires were not removed earlier nor were the nerves surgically explored in others. The nerve injuries resolved clinically on an average time of 3.5 months (range from 3 weeks to 8 months). Our study found complete resolution of all patients with nerve injuries confirmed by clinical assessment. On the basis of our study, we believe that there is no indication to remove the K-wires immediately or to explore the nerve surgically following a mini-open technique, which reduces the risk of penetrating a nerve during pinning.
    Matched MeSH terms: Bone Wires