Displaying publications 21 - 40 of 681 in total

Abstract:
Sort:
  1. Selvamuniandy TS, Mohamed N, Mansor SM, Nair NK, Navaratnam V
    J Chromatogr B Biomed Sci Appl, 1997 Oct 24;700(1-2):209-13.
    PMID: 9390731
    A selective and sensitive HPLC assay for the quantitative determination of a new antifilarial drug, 6,4'-bis-(2-imidazolinylhydrazone)-2-phenylimidazo[1,2-a]pyr idine (CDR 101) is described. After extraction from plasma and blood, CDR 101 was analysed using a C18 Nucleosil ODS column (250x4.6 mm, 5 microm particle size) and mobile phase of acetonitrile-0.05 M ammonium acetate adjusted to pH 3.0, with UV detection at 318 nm. The mean recoveries of CDR 101 in plasma and blood over a concentration range of 25-500 ng/ml were 95.5+/-2.01% and 83.3+/-1.87%, respectively. The within-day and day-to-day coefficient of variations for plasma were 3.23-6.21% and 2.59-9.90%, respectively, those for blood were 2.59-5.92% and 2.89-6.82%, respectively. The minimum detectable concentration for CDR 101 was 1 ng/ml in plasma and 2.5 ng/ml in whole blood. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  2. Malays J Nutr, 1997;3(2):-.
    MyJurnal
    This article examines the fat and fibre intakes of Malaysian adults and highlights discrepancies and practical limitations if these intakes are to match the levels for these nutrients advocated in the World Health Organisation (WHO) and American Heart Association (AHA) ‘diet models’. Local data on food consumption showed that the total fat intakes amongst Malaysian adults, contrary to common perception, were not high and the mean values obtained fell within the range of 40-66g or 22-26% kcal. As such, the dietary target of 30% kcal total fat or its intermediate target of 30-35% kcal, advocated by WHO and AHA mainly to address the problem of a high consumption of dietary fats in western populations, should not be adopted indiscriminately by Malaysians. Dietary fatty acid (FA) analysis by high performance liquid chromatography (HPLC) coupled with the use of food composition tables, showed that the typical Malaysian diet prepared with palm olein or palm olein-groundnut oil blends as cooking oil contained 3.2-4.0% kcal polyunsaturated fatty acids (PUFA), mainly as the w-6 linoleic acid, which is also the predominant essential fatty acid (EFA) in humans. This level of linoleic acid, with an ω-6/ ω--3 FA ratio approximating 10, is adequate for basal PUPA and EFA needs but fell short of the 4-10% kcal linoleic acid recommended by WHO (1993) to counter the effects of the cholesterol-raising saturated fatty acids (SFA). This raised upper limit of 10% kcal linoleic acid (previously 7% kcal), which equals the level of PUFA implied in the AHA diet model, appears unnecessarily high considering that the cholesterol-lowering potential of linoleic acid is maximum at about 6% kcal, while the health hazards associated with long-term high intakes of PUPA have never been completely dismissed. The new WHO lower limit for dietary linoleic acid (4% kcal) would have a controversial impact of raising the previous minimal 3% kcal EFA to above 4% kcal (linoleic + alpha-linolenic acids). Similarly, the WHO recommendation for total dietary fibre of 27-40g (equivalent to a daily combined intake of 400g of vegetables and fruits, 30g of which should come from pulses) appears at present, too high a dietary target for the average Malaysian adult whose habitual daily diet was estimated to contain about 180g of vegetables plus fruits, providing only about 13-16g total dietary fibre. Appropriately, an expert panel on Malaysian Dietary Guidelines has recommended instead, 20-30% kcal total fat containing 3-7% kcal PUFA, and 20-30g total dietary fibre for the local population.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  3. Yuen KH, Peh KK, Billa N, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Feb;24(2):193-6.
    PMID: 15605452
    The bioavailability of a generic preparation of acyclovir (Avorax) was compared with the innovator product, Zovirax. Twelve healthy volunteers participated in the study, conducted according to a randomized, two-way crossover design. The preparations were compared using the parameters area under the plasma concentration time curve (AUC(0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the Tmax or the logarithmic transformed AUC(0-infinity) and C(max) values of the two preparations. In addition, the 90% confidence interval for the ratio of the logarithmic transformed AUC(0-infinity) values of Avorax over those of Zovirax was found to lie between 0.85 and 1.06, while that of the logarithmic transformed Cmax values was between 0.95 and 1.25, being within the bioequivalence limit of 0.80-1.25. Moreover, the elimination rate constant (k(e)), elimination half-life (t(1/2)), and apparent volume of distribution (Vd) values obtained with the two preparations were comparable and not significantly different statistically.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  4. Jeyaseelan K, Armugam A, Lachumanan R, Tan CH, Tan NH
    Biochim. Biophys. Acta, 1998 Apr 10;1380(2):209-22.
    PMID: 9565688
    Cardiotoxins are the most abundant toxin components of cobra venom. Although many cardiotoxins have been purified and characterized by amino acid sequencing and other pharmacological and biochemical studies, to date only five cardiotoxin cDNAs from Taiwan cobra (Naja naja atra), three cDNAs from Chinese cobra (Naja atra) and two more of uncertain origin (either Chinese or Taiwan cobra) have been reported. In this paper we show the existence of four isoforms of cardiotoxin by protein analysis and nine cDNA sequences encoding six isoforms of cardiotoxins (CTX 1-3, 4a, 4b and 5) from N. n. sputatrix by cDNA cloning. This forms the first report on the cloning and characterization of several cardiotoxin genes from a single species of a spitting cobra. The cDNAs encoding these isoforms, obtained by reverse transcription-polymerase chain reaction (RT-PCR), were subsequently expressed in Escherichia coli. The native and recombinant cardiotoxins were first characterized by Western blotting and N-terminal protein sequencing. These proteins were also found to have different levels of cytolytic activity on cultured baby hamster kidney cells. Four of the isoforms (CTX 1, 2, 4 and 5) are unique to N. n. sputatrix, with CTX 2 being the most abundant species constituting about 50% of the total cardiotoxins. The isoform CTX 3 (20% constitution) is highly homologous to the cardiotoxins of N. n. atra and N. n. naja, indicating that it may be universally present in all Naja naja subspecies. Our studies suggest that the most hydrophilic isoform (CTX 5) could have evolved first followed by the hydrophobic isoforms (CTX 1, 2, 3 and 4). We also speculate that Asiatic cobras could be the modern descendants of the African and Egyptian counterparts.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  5. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Yuen KH, Peh KK
    J Chromatogr B Biomed Sci Appl, 1998 Sep 18;715(2):436-40.
    PMID: 9792531
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5-8000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  7. Jia Woei Wong, Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Sep 25;716(1-2):387-91.
    PMID: 9824257
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of pentoxifylline in human plasma. Prior to analysis, pentoxifylline and the internal standard (chloramphenicol) were extracted from plasma sample using dichloromethane. The mobile phase comprised 0.02 M phosphoric acid adjusted to pH 4, methanol and tetrahydrofuran (55:45:1, v/v). Analysis was run at a flow-rate of 1.4 ml/min with the detector operated at a wavelength of 273 nm. The method was specific and sensitive with a detection limit of approximately 3.0 ng/ml at a signal to noise ratio of 3:1, while the limit of quantification was 12.5 ng/ml. Mean recovery value of the extraction procedure was about 99.9%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 10.0%. The calibration curve was linear over a concentration range of 12.5-400.0 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  8. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  9. Saad B, Ariffin M, Saleh MI
    Talanta, 1998 Dec;47(5):1231-6.
    PMID: 18967428
    A flow injection potentiometric method for the rapid determination of paraquat in herbicide formulations and biological samples is described. It is based on the utilization of a flow-through potentiometric detector containing polyvinyl chloride-immobilised octamethylcyclotetrasiloxane, a lipophilic plasticizer (tetra-n-undecyl 3,3',4,4'-benzophenone tetracarboxylate) and membrane additive potassium tetrakis(4-chlorophenyl)borate. The detector was minimally interfered by the presence of constituents such as Na(+), K(+), Ca(2+), Mg(2+), glucose, urea, lactic and citric acids at physiological levels, respectively. Good correlation between results of the proposed method and HPLC for the formulation samples was found, while results for the determination of paraquat in biological samples such as urine, vomitus and stomach washout was less satisfactory.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  10. Chan KL, Choo CY, Morita H, Itokawa H
    Planta Med, 1998 Dec;64(8):741-5.
    PMID: 17253320 DOI: 10.1055/s-2006-957570
    An analytical method using HPLC with UV detection was developed to investigate the quassinoid content of Eurycoma longifolia Jack (Simaroubaceae) collected from various sources. Eurycomanone (1), longilactone (2), 14,15beta-dihydroxyklaineanone (3), 15beta-acetyl-14-hydroxyklaineanone (4), 6alpha-hydroxyeurycomalactone (5), and eurycomalactone (7) were isolated as reference standards and together with the synthesized 1beta,12alpha,15beta-triacetyleurycomanone (6, internal standard), were identified by NMR, MS, UV and IR spectroscopies. Their coefficient of variation values for 0.50-35 microg ml(-1) concentrations of quassinoids and their retention times measured within- and between-day were small. The recoveries of the spiked quassinoids in E. longifolia samples and their detection limits at 8.5 times signal to noise ratio were 99.75-109.13% and 0.01 microg ml(-1), respectively. From the root samples analysed, 1 had the highest concentration, being about 16.8-39.6 fold higher than the other quassinoids 2, 3, 5, 7 but 145.3 fold higher than 4 which showed the lowest concentration.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  11. Abdullah N, Nawawi A, Othman I
    Mycopathologia, 1998;143(1):53-8.
    PMID: 10205885
    In a survey of starch-based foods sampled from retail outlets in Malaysia, fungal colonies were mostly detected in wheat flour (100%), followed by rice flour (74%), glutinous rice grains (72%), ordinary rice grains (60%), glutinous rice flour (48%) and corn flour (26%). All positive samples of ordinary rice and glutinous rice grains had total fungal counts below 10(3) cfu/g sample, while among the positive rice flour, glutinous rice flour and corn flour samples, the highest total fungal count was more than 10(3) but less than 10(4) cfu/g sample respectively. However, in wheat flour samples total fungal count ranged from 10(2) cfu/g sample to slightly more than 10(4) cfu/g sample. Aflatoxigenic colonies were mostly detected in wheat flour (20%), followed by ordinary rice grains (4%), glutinous rice grains (4%) and glutinous rice flour (2%). No aflatoxigenic colonies were isolated from rice flour and corn flour samples. Screening of aflatoxin B1, aflatoxin B2, aflatoxin G1 and aflatoxin G2 using reversed-phase HPLC were carried out on 84 samples of ordinary rice grains and 83 samples of wheat flour. Two point four percent (2.4%) of ordinary rice grains were positive for aflatoxin G1 and 3.6% were positive for aflatoxin G2. All the positive samples were collected from private homes at concentrations ranging from 3.69-77.50 micrograms/kg. One point two percent (1.2%) of wheat flour samples were positive for aflatoxin B1 at a concentration of 25.62 micrograms/kg, 4.8% were positive for aflatoxin B2 at concentrations ranging from 11.25-252.50 micrograms/kg, 3.6% were positive for aflatoxin G1 at concentrations ranging from 25.00-289.38 micrograms/kg and 13.25% were positive for aflatoxin G2 at concentrations ranging from 16.25-436.25 micrograms/kg. Similarly, positive wheat flour samples were mostly collected from private homes.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  12. Ali N, Hashim NH, Yoshizawa T
    Food Addit Contam, 1999 Jul;16(7):273-80.
    PMID: 10656052
    For application to the analysis of aflatoxins (AF) in commercial peanut and corn products, the ISOLUTE multimode column (IMC, solid phase multifunctional column) method was validated by comparing with the modified Florisil column (MFC) method. Twenty-two peanut and eight corn products from Malaysia and the Philippines were analysed for AFB1, AFB2, AFG1 and AFG2 firstly by the MFC method and then by the IMC method. For peanut products, 14 out of 22 samples were positive by the two methods in the range of 1-378 micrograms/kg of AF, and correlation coefficients (r) for AFB1 and AFB2 were 0.987 and 0.997, respectively. For corn and corn products, all the samples were positive in the range of 1-130 micrograms/kg, and r values were 0.992 and 0.805 for AFB1 and AFB2 respectively. Thus, the results were significantly (p < 0.01) in close agreement, particularly for lower range of 1-50 micrograms/kg of AF concentrations in all the samples. For the occurrence of AF, 11 (65%) of peanut products from Malaysia were contaminated with AF at a mean level of 50 micrograms/kg (maximum 180 micrograms/kg) and two (40% products from the Philippines were contaminated with as high as 375 micrograms/kg and 177 micrograms/kg of AF, respectively. All the corn products from the Philippines were contaminated with AF at a mean level of 44 micrograms/kg (maximum 130 micrograms/kg). Contamination of commercial foods with high levels of AF is a very important issue to both the countries since these foods are very popular among children.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  13. Yuen KH, Wong JW, Billa N, Julianto T, Toh WT
    Int J Clin Pharmacol Ther, 1999 Jul;37(7):319-22.
    PMID: 10442505
    The bioavailability of a generic preparation of metformin (Diabetmin from Hovid Sdn Bhd) was evaluated in comparison with a proprietary product (Glucophage from Lipha Pharma Ltd., UK).
    Matched MeSH terms: Chromatography, High Pressure Liquid
  14. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Ramli N, Abdul Rahman S, Hassan O, Mohd Yatim A, Said M, Lim LS, et al.
    Malays J Nutr, 2000 Mar;6(1):55-63.
    PMID: 22692392
    Thirty-two samples of chocolate products were analysed by HPLC for caffeine and theobromine contents. Defatted residues of samples were extracted with 80% aqueous acetone. After extraction into boiling water, the methylxanthines were identified and quantified with the use of μ-Bondapak column and mobile phase of methanol:water:acetic acid (20:79:1). Levels of caffein and theobromine in 32 samples of chocolate products averaged 0.62-1.14 mg/g and 0.026-0.153 mg/g respectively. Mean values for theobromine and caffeine content for chocolate coating were 0.82 and 0.07 mg/g respectively. The chocolate coating made from fat substitute had theobromine and caffeine levels ranging from 0.36-0.70 mg/g and 0.027-0.061 mg/g respectively, with mean values of 0.49 mg theobromine/g and 0.039 mg caffeine/g. In local chocolate, the mean theobromine and caffeine levels respectively were 0.72 mg/g and 0.04 mg/g in milk chocolate, and 0.85 mg/g and 0.06 mg/g in dark chocolate. Meanwhile, for imported chocolate, the mean theobromine and caffeine levels respectively were 1.05 mg/g and 0.12 mg/g in dark chocolate; 0.76 mg/g and 0.04 mg/g in milk chocolate; and 0.74 mg/g and 0.03 mg/g in white chocolate. Compared with the local chocolates, imported chocolates had higher levels of theobromine and caffeine at 1.141 mg/g and 0.1533mg/g. The average theobromine and caffeine concentrations in local chocolate were 0.082mg/g and 0.066mg/g. Theobromine concentration in chocolate samples is within the range of 0.62mg/g-1.141mg/g and the range of caffeine concentration is 0.026mg/g-0.153mg/g respectively. Bittersweet chocolates were found to have higher theobromine and caffeine concentrations than normal sweet chocolates and milk chocolates.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  17. Peh KK, Wong CF, Yuen KH
    Drug Dev Ind Pharm, 2000 Apr;26(4):447-50.
    PMID: 10769787
    Lipophilicity was evaluated as a possible mechanism for drug retardation from a glyceryl monostearate matrix system. Lipophilicity of the glyceryl monostearate matrix system was studied using contact angle measurement of water droplets on the surface of compressed disks, extrudate ascension of water, and movement of water through a powder mixture packed in a high-performance liquid chromatographic (HPLC) column. Increase in glyceryl monostearate content resulted in an increase in water droplet contact angle, decrease in the rate of water ascending the extrudate, and increase in the pressure values as a function of flow rate of water moving through the powder mixture. These could be due to the increase in lipophilicity of the matrix, rendering the matrix less wettable. As a result, the rate of water penetration into the matrix decreased, and the drug release could be sustained.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  18. Yusof RM, Haque F, Ismail M, Hassan Z
    Asia Pac J Clin Nutr, 2000 Jun;9(2):130-5.
    PMID: 24394399
    Probiotic organism Bifidobacteria was isolated from the faeces of breast-fed infants at Universiti Putra Malaysia. Trypticase phytone peptone yeast extract agar (TPY) was used as a selective media for the isolation. Morphological examination of the isolates indicated that Bifidobacteria was Gram-positive rods in nature, curved with characteristics of V and Y shapes. The organisms were non-catalase producing, non-nitrate reducing, non-motile, had an absence of indole and were unable to liquify gelatin. The ratios of acetic and lactic acids were determined using high performance liquid chromatography (HPLC). Using carbohydrate fermentation profile test API-CH-50 kits, 20 Bifidobacteria strains had been identified: they were the species of Bifidobacteria infantis and two different sub-species, mainly infantis and lacentis. Based on a wide zone of inhibition, three suitable strains of B. infantis, Bifi-11, Bifi-19 and Bifi-20, were tested in weaning foods for antimicrobial activity towards two human pathogens: E. coli-0157 (World Health Organization) and Salmonella typhimurium S-285. The pH, titratable acidity of weaning foods and total colony count for Bifidobacteria, enteropathogenic Escherichia coli and S. typhimurium were recorded at 3-h intervals for 30 h. It was found that after 9 h of incubation of weaning foods, the pH declined to < 3.6 from pH 6.0, whereas titratable acidity increased from 0.026 to 0.08%. It was indicated that Bifidobacteria inhibited E. coli better than did S typhimurium due to low pH. After 24 h of incubation, approximately 98% of E. coli was inhibited by Bifidobacteria. It is suggested that the inhibitory effect of Bifidobacteria strains in weaning foods towards the growth of enteropathogenic E. coli and S. typhimurium was solely due to low pH and the production of volatile acid components by the organism.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  19. Xu ZQ, Norris KJ, Weinberg DS, Kardatzke J, Wertz P, Frank P, et al.
    J Chromatogr B Biomed Sci Appl, 2000 Jun 09;742(2):267-75.
    PMID: 10901131
    A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (+/-)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C(18) cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  20. Yuen KH, Wong JW, Peh KK, Julianto T, Choy WP
    Drug Dev Ind Pharm, 2000 Jul;26(7):803-7.
    PMID: 10872103
    The bioavailability of a generic preparation of pentoxifylline sustained-release (SR) tablet was evaluated in comparison with a proprietary product (Trental 400). For the study, 12 healthy male volunteers participated; the study was conducted according to a randomized, two-way crossover design. The bioavailability was compared using the parameters total area under the plasma level-time curve AUC0-infinity, peak plasma concentration Cmax, and time to reach peak plasma concentration Tmax. No statistically significant difference was observed between the values of the two products in all three parameters. The 90% confidence interval for the ratio of the logarithmic transformed AUC0-infinity values of the generic pentoxifylline over those of Trental 400 was found to lie between 0.83 and 1.00, while that of the parameter Cmax was between 0.91 and 1.29. In addition, elimination half-life t1/2 and apparent volume of distribution Vd were calculated. There was no statistically significant difference between the t1/2 Vd values obtained from the data of the two preparations.
    Matched MeSH terms: Chromatography, High Pressure Liquid
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links