METHODS: Using the Short Form of Depression, Anxiety and Stress Scale (DASS21) questionnaire, we aimed (1) to measure the psychological states of hemodialysis (HD) or peritoneal dialysis (PD) subjects from 15 sites, (2) to compare DASS21 scores between HD and PD, and (3) to identify the associated demographic and medical factors of better psychological states.
RESULTS: A total of 1,332 were eligible for analysis. Stress (48%) recorded the highest negative emotional states, followed by depression (37%) and anxiety (20%). By multivariate analysis, normal body mass index weight status, religion and absence of coronary artery disease were associated with lower score for depression, anxiety and stress, respectively. Tertiary education was associated with the lowest score in depression and anxiety, whereas HD had a lower score in stress than PD. A younger age was associated with worse DASS21 score of anxiety and stress.
CONCLUSIONS: Obesity, religion and coronary artery disease were significantly associated with all 3 symptoms of depression, anxiety and stress. Older age has a protective effect on anxiety and stress. Further study is needed to evaluate the relationship between these significant factors and each psychological state.
METHOD: Between November 2009 and July 2010, outpatients from 45 countries who met the criteria for stable CAD were recruited into the registry. Baseline characteristics were documented at enrolment, and patients were reassessed during their annual visits over a five-year follow-up period. Key outcomes measured were sudden death and cardiovascular (CV) death, non-CV death and CV morbidity.
RESULTS: At baseline, 33,283 patients were available for analysis within the registry; 380 and 27 were Malaysians and Bruneians, respectively. The mean ages of Malaysian/Bruneian patients and the rest of the world (RoW) were 57.83 ±9.98 years and 64.23 ± 10.46 years, respectively (p<0.001). The median body mass index values were 26.6 (24.4-29.6) kg/m2 and 27.3 (24.8-30.3) kg/m2, respectively (p=0.014). Malaysian/Bruneian patients had lower rates of myocardial infarction (54.55% versus 59.76%, p=0.033) and higher rates of diabetes (43.24% versus 28.99%, p<0.001) and dyslipidaemia (90.42% versus 74.66%, p<0.001) compared with the RoW. Measured clinical outcomes in Malaysian and Bruneian patients at 2-years follow-up were low and generally comparable to the RoW.
CONCLUSION: Malaysian/Bruneian patients with stable CAD tend to be younger with poorer diabetic control compared with the RoW. However, they had similar outcomes as the main registry following two years of treatment.
Methods: Twenty-seven patients with history of anterior myocardial infarction (MI) and baseline left ventricular ejection fraction (LVEF) of less than 35% were recruited into this study. Patients who are eligible for revascularization were grouped into group A (MSCs infusion with concurrent revascularization) or group B (revascularization only) while patients who were not eligible for revascularization were allocated in group C to receive intracoronary MSCs infusion. LV function was measured using echocardiography.
Results: Patients who received MSCs infusion (either with or without revascularization) demonstrated significant LVEF improvements at 3, 6 and 12 months post-infusion when compared to baseline LVEF within its own group. When comparing the groups, the magnitude of change in LVEF from baseline for third visits i.e., 12 months post-infusion was significant for patients who received MSCs infusion plus concurrent revascularization in comparison to patients who only had the revascularization procedure.
Conclusions: MSCs infusion significantly improves LV function in ICM patients. MSCs infusion plus concurrent revascularization procedure worked synergistically to improve cardiac function in patients with severe ICM.
METHODOLOGY: The "Preferred Reporting Items for Systematic Reviews and Meta-Analyses" (PRISMA) guidelines were followed. Six databases were systematically searched using Medical Subject Headings/Index and Entree terms. After a thorough screening, fourteen publications spanning over ten years (2007-2017) were eligible for this systematic review and meta-analysis.
RESULTS: Out of 14 included studies, 12 reported presence of periodontal bacterial DNA in coronary atherosclerotic plaque specimens. Overall, Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were the most frequently detected periodontal bacterial species. Meta-analysis revealed that the prevalence of P. gingivalis was significantly higher than A. actinomycetemcomitans in coronary atheromatous plaque samples. Apart from periodontal microbes, DNA from a variety of other microbes e.g. Pseudomonas fluorescens, Streptococcus species, Chlamydia pneumoniae were also recovered from the collected samples.
CONCLUSION: Consistent detection of periodontal bacterial DNA in coronary atheroma suggests their systemic dissemination from periodontal sites. It should further be investigated whether they are merely bystanders or induce any structural changes within coronary arterial walls.
METHODS: We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292).
RESULTS: A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 ± 10.4 mm in the de novo group, and 20.1 ± 8.9 mm (BMS-ISR) and 16.2 ± 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 ± 0.41 mm (de novo), 2.71 ± 0.31 mm (BMS-ISR), and 2.92 ± 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 ± 0.39 mm (de novo), 3.00 ± 0.35 mm (BMS-ISR), and 3.10 ± 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901).
CONCLUSIONS: The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.
BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.
METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.
RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.
CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.
BACKGROUND: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available.
METHODS: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones.
RESULTS: After 13 months (interquartile range 5-32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71).
CONCLUSION: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation.