Displaying publications 21 - 30 of 30 in total

Abstract:
Sort:
  1. Hui MT, Subash S, Wang CY
    Anaesthesia, 2011 Apr;66(4):274-7.
    PMID: 21401540 DOI: 10.1111/j.1365-2044.2011.06620.x
    The 50% and 95% effective doses of desflurane for removal of the classic laryngeal mask airway after suction of the upper airway, in anaesthetised spontaneously breathing adult patients, are not known. To determine these, we studied 38 healthy patients, aged between 18 and 44 years. The target desflurane concentration in each individual patient was determined by the Dixon up-and-down method. When the predetermined target end-tidal desflurane concentration reached steady state, we kept a constant end-expiratory partial pressure between the alveolus and the brain for 10 min before attempting to remove the classic laryngeal mask airway after suctioning the upper airway. The initial desflurane target concentration was set at 6% and up-down desflurane increments were 0.1%. This continued until there were at least six crossover pairs. From the probit analysis, the 50% effective dose of desflurane was 5.29% (95% CI 5.132-5.379%) and the 95% effective dose was 5.55% (95% CI 5.429-6.394%).
    Matched MeSH terms: Device Removal/methods
  2. Ho YL, Jamaluddin MF, Krishinan S, Salleh A, Khamis AY, Abdul Kareem BA
    Asian Cardiovasc Thorac Ann, 2020 Mar;28(3):152-157.
    PMID: 32122151 DOI: 10.1177/0218492320910932
    Matched MeSH terms: Device Removal
  3. Constance LSL, Lansing MG, Khor FK, Muniandy RK
    BMJ Case Rep, 2017 Nov 23;2017.
    PMID: 29170175 DOI: 10.1136/bcr-2017-221659
    Administering anaesthesia for elderly patients with chronic schizophrenia has always been a great challenge to anaesthetists. These patients will usually be on multiple antipsychotic drugs for many years and may lead to delayed awakening, cardiovascular instability, arrhythmias and sudden cardiac death during general anaesthesia. This case report is about the perioperative anaesthetic management of an elderly schizophrenic patient undergoing removal of femur implant. This article will explore important drug interactions and available options for a successful anaesthesia.
    Matched MeSH terms: Device Removal/adverse effects; Device Removal/methods
  4. Chendran P, Seng Fai T, Wan Abdul Halim WH, Md Din N
    J Glaucoma, 2019 10;28(10):e162-e164.
    PMID: 31368915 DOI: 10.1097/IJG.0000000000001334
    Ocular pyogenic granuloma is a benign tumor seen after ocular insult secondary to ocular surgeries, trauma or infection. Although benign, intervention is sometimes necessary. Previous authors have reported pyogenic granuloma formation following oculoplastic surgeries. We report a pyogenic granuloma after an Ahmed glaucoma valve implantation. A 65-year-old gentleman presented with right eye redness associated with pain and swelling ~2 months after Ahmed glaucoma valve implantation. Examination found a sessile growth on the tube extruding puss with signs of endophthalmitis. The glaucoma drainage device was explanted and culture results grew Staphylococcus aureus. This article discusses the formation of pyogenic granuloma on a glaucoma drainage device and its management.
    Matched MeSH terms: Device Removal
  5. Batra YK, Ivanova M, Ali SS, Shamsah M, Al Qattan AR, Belani KG
    Paediatr Anaesth, 2005 Dec;15(12):1094-7.
    PMID: 16324030 DOI: 10.1111/j.1460-9592.2005.01633.x
    BACKGROUND: Laryngospasm is a well-known problem typically occurring immediately following tracheal extubation. Propofol is known to inhibit airway reflexes. In this study, we sought to assess whether the empiric use of a subhypnotic dose of propofol prior to emergence will decrease the occurrence of laryngospasm following extubation in children.
    METHODS: After approval from the Institutional Ethics Committee and informed parental consent, we enrolled 120 children ASA physical status I and II, aged 3-14 years who were scheduled to undergo elective tonsillectomy with or without adenoidectomy under standard general anesthesia. Before extubation, the patients were randomized and received in a blinded fashion either propofol 0.5 mg.kg(-1) or saline (control) intravenously. Tracheal extubation was performed 60 s after administration of study drug, when the child was breathing regularly and reacting to the tracheal tube.
    RESULTS: Laryngospasm was seen in 20% (n = 12) of the 60 children in the control group and in only 6.6% (n = 4) of 60 children in the propofol group (P < 0.05).
    CONCLUSIONS: During emergence from inhalational anesthesia, propofol in a subhypnotic dose (0.5 mg.kg(-1)) decreases the likelihood of laryngospasm upon tracheal extubation in children undergoing tonsillectomy with or without adenoidectomy.
    Matched MeSH terms: Device Removal
  6. Badrul B, Ruslan G
    Med J Malaysia, 2000 Sep;55 Suppl C:93-6.
    PMID: 11200051
    We report a 64 year old man who developed Candida albicans infection following total knee arthroplasty. A two-stage exchange arthroplasty was performed after an initial swab culture grew Acinobacter sp. A scanty growth of yeast was also found from the tissue culture. Intravenous cefuroxime was instituted for six weeks followed by reimplantation four months after the removal. Three weeks after that revision, the prosthesis became infected and a culture of knee aspirate established the diagnosis of Candida albicans infection. Treatment consisted of thorough debridement of the involved joint and oral fluconazole for a year. Infection was never totally resolved and a secondary infection with methicillin resistant staphylococcus aureus then developed. Excision arthroplasty was done at two and a half years after the initial infection. At five years follow-up the infection was quiescent and he had a range of movement of 30 degrees to 70 degrees. Knee brace was used to control the valgus-varus stability.
    Matched MeSH terms: Device Removal
  7. Aryasit O, Ng DS, Goh ASC, Woo KI, Kim YD
    BMC Ophthalmol, 2016 Jul 07;16:94.
    PMID: 27387333 DOI: 10.1186/s12886-016-0287-0
    BACKGROUND: Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported.

    CASE PRESENTATION: This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.

    CONCLUSIONS: Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.

    Matched MeSH terms: Device Removal
  8. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Device Removal
  9. Ahmed T, Rahman NA, Alam MK
    Biomed Res Int, 2021;2021:6663683.
    PMID: 33959664 DOI: 10.1155/2021/6663683
    Objective: To compare the orthodontic bracket debonding force and assess the bracket failure pattern clinically between different teeth by a validated prototype debonding device. Materials and Method. Thirteen (13) patients at the end of comprehensive fixed orthodontic treatment, awaiting for bracket removal, were selected from the list. A total of 260 brackets from the central incisor to the second premolar in both jaws were debonded by a single clinician using a validated prototype debonding device equipped with a force sensitive resistor (FSR). Mean bracket debonding forces were specified to ten (10) groups of teeth. Following debonding, Intraoral microphotographs of the teeth were taken by the same clinician to assess the bracket failure pattern using a 4-point scale of adhesive remnant index (ARI). Statistical analysis included one-way ANOVA with post hoc Tukey HSD and independent sample t-test to compare in vivo bracket debonding force, Cohen's kappa (κ), and a nonparametric Kruskal-Wallis test for the reliability and the assessment of ARI scoring.

    Results: A significant difference (p < 0.001) of mean debonding force was found between different types of teeth in vivo. Clinically, ARI scores were not significantly different (p = 0.921) between different groups, but overall higher scores were predominant.

    Conclusion: Bracket debonding force should be measured on the same tooth from the same arch as the significant difference of mean debonding force exists between similar teeth of the upper and lower arches. The insignificant bracket failure pattern with higher ARI scores confirms less enamel damage irrespective of tooth types.

    Matched MeSH terms: Device Removal*
  10. Afzal MR, Daoud EG, Cunnane R, Mulpuru SK, Koay A, Hussain A, et al.
    Heart Rhythm, 2018 06;15(6):841-846.
    PMID: 29427820 DOI: 10.1016/j.hrthm.2018.02.008
    BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.

    OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.

    METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.

    RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.

    CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.

    Matched MeSH terms: Device Removal/methods*